Laserfiche WebLink
C- <br />A <br />- <br />2 <br />0 <br />2 <br />3 <br /> <br />© <br />2 <br />0 <br />2 <br />3 <br /> <br />S <br />I <br />M <br />P <br />S <br />O <br />N <br /> <br />S <br />T <br />R <br />O <br />N <br />G <br />- <br />T <br />I <br />E <br /> <br />C <br />O <br />M <br />P <br />A <br />N <br />Y <br /> <br />I <br />N <br />C <br />. <br />133 <br />Me <br />c <br />h <br />a <br />n <br />i <br />c <br />a <br />l <br /> <br />An <br />c <br />h <br />o <br />r <br />s <br />Simpson Strong-Tie® Anchoring, Fastening, Restoration and Strengthening Systems for Concrete and Masonry <br />*See p. 14 for an explanation of the load table icons. <br />Titen Turbo™ Concrete and Masonry Screw Anchor <br />1,2,3 <br />Anchor Diameter <br />(in.) <br />Embedment Depth <br />(in.) <br />Minimum Dimensions <br />(in.)Allowable Load <br />(lb.)4SpacingEdgeEnd <br />3/16 1 1/4 3 3 7/8 3 7/8 117 <br />1/4 1 1/4 4 3 7/8 3 7/8 117 <br />1. The tabulates values are for screw anchors installed in minimum 8"-wide hollow masonry walls having reached a minimum <br />f'm of 1,500 psi at time of installation. <br />Embedment is the thickness of the face shell. <br />Screw anchors may be installed at any location in the wall face provided the minimum edge and end distances are maintained. <br />Allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. <br />*IBC <br />Allowable Shear Load for Titen Turbo Screw Anchor <br />Installed in Hollow CMU Wall Faces1,2,3 <br />Anchor <br />Diameter <br />(in.) <br />Embedment <br />Depth <br />(in.) <br />Minimum Dimensions (in.)Direction of Loading Allowable Load (lb.)4 <br />Spacing Edge End <br />3/16 1 1/4 3 3 7/8 3 7/8 Toward edge, parallel to wall end 164 <br />1/4 1 1/4 4 3 7/8 3 7/8 Toward edge, parallel to wall end 190 <br />1. The tabulates values are for screw anchors installed in minimum 8"-wide hollow masonry walls having reached a minimum <br />f'm of 1,500 psi at time of installation. <br />Embedment is the thickness of the face shell. <br />Screw anchors may be installed at any location in the wall face provided the minimum edge and end distances are maintained. <br />Allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. <br />*IBC <br />Allowable Tension Load for Titen Turbo Screw Anchor <br />Installed in Face of Grouted CMU1,2,3 <br />Anchor <br />Diameter (in.) <br />Embedment <br />Depth (in.) <br />Minimum Dimensions <br />(in.)Allowable Load <br />(lb.)4 <br />Spacing Edge End <br />3/16 2 3 3 7/8 3 7/8 267 <br />3/16 2 3 1 1⁄2 3 7/8 267 <br />1/4 2 4 3 7/8 3 7/8 393 <br />1/4 2 4 1 1⁄2 3 7/8 343 <br />1. The tabulates values are for screw anchors installed in minimum 8"-wide grouted concrete masonry walls having <br />reached a minimum f'm of 1,500 psi at time of installation. <br />Embedment is measured from the masonry surface to the embedded end of the screw anchor. <br />Screw anchors must be installed in grouted cell. The minimum edge and end distances must be maintained. <br />Allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. <br />*IBC <br />Allowable Shear Load for Titen Turbo Screw Anchor <br />Installed in Face of Grouted CMU1,2,3 <br />Anchor <br />Diameter <br />(in.) <br />Embedment <br />Depth <br />(in.) <br />Minimum Dimensions(in.)Direction of Loading Allowable Load (lb.)4 <br />Spacing Edge End <br />3/16 2 3 3 7/8 3 7/8 Toward edge, parallel to wall end 218 <br />3/16 2 3 1 1⁄2 3 7/8 Toward wall end, parallel to wall edge 218 <br />1/4 2 4 3 7/8 3 7/8 Toward edge, parallel to wall end 342 <br />1/4 2 4 1 1⁄2 3 7/8 Toward wall end, parallel to wall edge 283 <br />1. The tabulates values are for screw anchors installed in minimum 8"-wide grouted concrete masonry walls <br />having reached a minimum f'm of 1,500 psi at time of installation. <br />Embedment is measured from the masonry surface to the embedded end of the screw anchor. <br />Screw anchors must be installed in grouted cell. The minimum edge and end distances must be maintained. <br />Allowable loads are based on a safety factor of 5.0 for installations under the IBC and IRC. <br />*IBC <br />1 <br />1821 E Newport Cir <br />12/23/2024