My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1621 W Tenth St Unit #2 - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tenth St
>
1621 W Tenth St Unit# 2
>
1621 W Tenth St Unit #2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:34:35 AM
Creation date
6/5/2025 7:34:27 AM
Metadata
Fields
Template:
Plan
Permit Number
101119850
Full Address
1621 W Tenth St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
49
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1. FRAMING <br />2. BOTTOM FLASHING <br />3. SILL FLASHING <br />4. SIDE FLASHING <br />5. WINDOW INSTALLATION <br />6. TOP FLASHING <br />7. BLDG. PAPER <br />ALL BUILDING PAPER TO BE "SUPER JUMBO-TEX" BY <br />FORTIFIBER OR APPROVED EQUAL. <br />ALL WINDOW FLASHING TO BE "MOISTOP" BY FORTIFIBER <br />OR APPROVED EQUAL. SELF ADHERING . <br />SHEET FLASHING TO BE "ICE AND WATER SHIELD" OR <br />APPROVED EQUAL. <br />1. FRAMING -WHERE THE OPENING OCCURS IN A WALL <br />ITHOUT EXTERIOR SHEATHING, THE BLOCKING MEMBER <br />(A) SHOULD BE INSTALLED AS NECESSARY TO SUPPORT <br />THE OUTSIDE EDGES OF SIDE FLASHING. INSTALL <br />APPROXIMATELY 16" O.C. BLOCKING MAY B E OMITTED <br />WHEN A STUD IS INSTALLED TO SUPPORT THE OUTSIDE <br />EDGE OF THE SIDE FLASHING. <br />2. BOTTOM (SILL) FLASHING -APPLY THE FIRST STRIP OF <br />FLASHING (B) HORIZONTAL, TIGHT TO THE BOTTOM OF <br />THE WINDOW OPENING. EXTEND FLASHING GREATER <br />THAN 12" PAST THE SIDES OF THE OPENING AND ATTACH <br />TO THE NEXT AVAILABLE STUD. FASTEN ONLY THE TOP <br />EDGE SO THAT SUBSEQUENT LAYERS OF BUILDING <br />PAPER MAY BE LAPPED UNDER (SHINGLED). <br />3. INSTALL SELF ADHERING SHEET FLASHING (C) <br />CONTINUOUS INTO THE FULL DEPTH OF THE FRAMED <br />OPENING ALONG THE SILL AND UP THE JAMBS 6" <br />MINIMUM. <br />4. INSTALL THE TWO SIDE (JAM) FLASHING STRIPS (D) <br />VERTICAL, TIGHT TO THE SIDES OF THE WINDOW <br />OPENING. EXTEND FLASHING ABOVE THE TOP AND <br />BELOW THE BOTTOM OF THE OPENING FOR A DISTANCE <br />EQUAL TO AT LEAST THE WIDTH OF THE FLASHING STRIP. <br />THE BOTTOMS OF THE VERTICAL SIDE STRIPS SHOULD <br />LAP OVER THE BOTTOM HORIZONTAL STRIP AND SHOULD <br />NOT BE NAILED SO THAT SUBSEUENT LAYERS OF <br />BUILDING PAPER MAY BE LAPPED UNDER (SHINGLED). <br />5. INSTALL THE WINDOW BY FIRMLY PRESSING THE NAIL <br />FLANGE ONTO A CONTINUOUS, FULL CONTACT BED OF <br />SEALANT (E) EXTENDING AROUND ALL FOUR SIDES OF <br />THE WINDOW FLANGE. THE SEALANT BEAD (APPROX. 3/8" <br />DIA.) SHOULD BE APPLIED TO THE BACK SIDE OF THE <br />NAILING FLANGE PRIOR TO MOUNTING THE WINDOW UNIT. <br />PLACE THE SEAANT IN THE LINE WITH PRE-PUNCHED <br />HOLES AND SLOTS. THE WINDOW SHOULD THEN BE <br />TRUED AND LEVELED. NAIL INTO PLACE PER MFR. <br />INSTRUCTIONS. <br />6. INSTALL THE TOP (HEAD) FLASHING TO LAP OVER THE <br />TOP NAILING FLANGE. PRESS THE BOTTOM EDGE OF THE <br />FLASHING STRIP INTO A CONTINUOUS, FULL CONTACT <br />BED OF SEALANT (F) ON THE OUTSIDE FACE OF THE <br />NAILING FLANGE. PLACE THE SEALANT IN LINE WITH PRE- <br />PUNCHED HOLES AND SLOTS. EXTEND THE ENDS OF THE <br />TOP FLASHING STRIP SO THAT IT AT LEAST OVERLAPS <br />THE OUTER EDGES OF THE SIDE FLASHING STRIPS. <br />7. STARTING AT THE BOTTOM OF THE WALL, INSTALL THE <br />WATERPROFF BUILDING PAPER IN "SHINGLE" FASHION UP <br />THE WALL. THE LAYER WHICH FALLS AT THE BOTTOM OF <br />THE WINDOW OPENING SHOULD BE LAPPED UNDER THE <br />BOTTOM OF THE WINDOW OPENING SHOULD BE LAPPED <br />UNDER THE BOTTOM FLASHING, SUCCESSIVE LAYERS OF <br />BUILDING PAPER SHOULD LAP OVER THE SIDE NAILING <br />FLANGES. <br />A A <br />B <br />C <br />D D <br />E <br />E <br />E E <br />F <br />EXTERIOR PORTLAND CEMENT PLASTER: <br />3 COAT ASSEMBLY PER UBC/CBC CHAPTER 25A. <br />WEATHER-RESISTIVE BARRIER: APPROVED <br />60 MINUTE BUILDING PAPER; <br />-ONE LAYER OVER STUD FRAMING <br />-2 LAYERS OVER SHEATHING <br />GALVANIZED METAL LATH APPROVED <br />FOR USE ON VERTICAL SURFACES <br />SCRATCH COAT <br />BROWN COAT <br />FINISH COAT <br />GALVANIZED EXPANDED METAL LATH <br />APPROVED <br />FOR USE ON HORIZONTAL SURFACES <br />BUILDING PAPER MAY BE OMITTED AT <br />APPLICATION <br />TO THE UNDERSIDE OF ROOF AND EAVE <br />PROJECTS (IF ALLOWED) <br />THIS DETAIL DESCRIBES TYPICAL GENERAL ASSEMBLY <br />COMPONENTS AND INSTALLATION PROCEDURE. REFER TO ACTUAL <br />CONDITIONS AND KEYED DETAILS FOR DIMESIONS, CONFIGURATIONS <br />AND OTHER SPECIFICS OF THE WORK <br />(2) -#4 BAR, TOP <br />(2) -#3 BAR , BOTTOM <br />2x P.T. SILL w 1/2" x 10" A.B. #6' O.C., <br />.229" x 3" x 3" PLATE WASHERS <br />#3 DOWELS @24" O.C., <br />EXTEND 36" INTO SLAB <br />(FOR TWO POUR) <br />2x STUD WALL @16" O.C. <br />(DF STUD GRADE -MIN.) <br />2x DOUBLE TOP PLATE <br />2x SOLID BLOCKING <br />w/APPROVED FRAMING <br />ANCHOR CLIPS EA. BLOCK <br />GYP. BOARD. <br />1/2" WOOD STR. PANEL <br />w/ 8d @ 6"/6"/12" oc <br />(COMMON NAILS) <br />2x ROOF RAFTERS <br />2x CEILING JOISTS <br />w/ R-30 BATT. INSUL. <br />WHERE STUCCO IS APPLIED OVER SHEATHING <br />PROVIDE 2-LAYERS GRADE 'D' PAPER UNDER LATH <br />15/32" WOOD STR. PANEL OR <br />STUCCO SHEAR PANEL <br />3-1/2" CONC. SLAB, #4 DEFORMED <br />REINF. @16" O.C. EA. WAY 2" SAND BED, <br />6 MIL VAPOR RETARDER <br />INTERIOR <br />PLYWOOD ROOF SHEATHING <br />2x ROOF RAFTERS <br />SEE STRUCTURAL <br />2x CEILING JOISTS <br />w/ R-30 BATT. INSUL. <br />SEE T-24 <br />SHINGLE ROOFING <br />w/ 2-LAYER #30 ROOF <br />UNDERLAYMENT <br />PLYWOOD ROOF SHEATHING <br />2x ROOF RAFTERS <br />SEE STRUCTURAL <br />RIDGE SHINGLE <br />SHINGLE ROOFING <br />w/ 2-LAYER #30 ROOF <br />UNDERLAYMENT <br />CONT. RIDGE. ,RIDGE <br />BLOCKING, OR HIP <br />BEAM (SEE STRUCT.) <br />NOTE: THIS DETAIL SHOWS GENERAL CONSTRUCTION. <br />REFER TO MANUFACTURER'S WATERPROOFING <br />INSTRUCTION & RECOMMENDATIONS <br />STUCCO SYSTEM ASSEMBLY <br />GALV. WEEP SCREED w/ 3-1/2" <br />VERTICAL FLANGE OVER S.A.S.F. <br />OVER WOOD TO CONCRETE JOINT <br />PAVING WHERE OCCURS <br />GRADE WHERE OCCURS <br />2% SLOPE <br />2% SLOPE WHERE ACCESSIBLE <br />EDGE OF FOUNDATION <br />15 <br />" <br /> <br />M <br />I <br />N <br />DUPLEX ELECTRICAL OUTLET PER <br />PLAN <br />DATA OUTLET PER PLAN <br />HARDWARE SET AS SCHEDULED <br />LIGHT SWITCH PER PLAN <br />THERMOSTAT PER PLAN <br />SCHEDULED DOOR <br />48 <br />" <br /> <br />M <br />A <br />X <br />38 <br />" <br /> <br />T <br />Y <br />P <br />18 <br />" <br /> <br />T <br />Y <br />P <br />5/8" GYP. BOARD <br />BATT INSUL. <br />STRUCTURAL SHEATING AS REQUIRED <br />7/8" CEMENT PLASTER WALL <br />ASSEMBLY OVER SIDING AS PER 2/AD-1.0 <br />INTERIOREXTERIOR <br />5/8" GYP. BOARD <br />BATT INSUL. <br />INTERIORINTERIOR <br />5/8" TYPE X GYP. BD. <br />STRUCTURAL SHEATING AS REQUIRED <br />7/8" CEMENT PLASTER WALL <br />ASSEMBLY OVER SIDING AS PER 2/AD-1.0 <br />INTERIOREXTERIOR <br />WATER RESITIVE BARRIER <br />CEMENT BACKER BOARD <br />STRUCTURAL SHEATING AS REQUIRED <br />7/8" CEMENT PLASTER WALL <br />ASSEMBLY OVER SIDING AS PER 2/AD-1.0 <br />INTERIOREXTERIOR <br />TILE o/THIN MORTAR <br />INTERIOR <br />PLYWOOD ROOF SHEATHING <br />2x ROOF RAFTERS <br />SEE STRUCTURAL <br />2x CEILING JOISTS <br />w/ R-30 BATT. INSUL. <br />SEE T-24 <br />SHINGLE ROOFING <br />w/ 2-LAYER #30 ROOF <br />UNDERLAYMENT <br />2 -5/8" TYPE X GYPSUM SHEATHING o/FRAMING w/VENT <br />REQ. TO PROTECT ROOF OVERHANG AS REQ. WITHIN <br />5'-0" OF P.L., EVERYWHERE ELSE TO BE NON FIRE RATED <br />(EXPOSED) WITH VENT -SEE A-0.0 FOR INFORMATION <br />5/8" TYPE X GYPSUM BOARD <br />STUCCO SYSTEM o/WOOD SIDING <br />FOR 1-HR FIRE RATING <br />4" MAX WHERE SIDE YARD DISTANCE TO PROPERTY LINE IS LESS THAN 30" <br />EAVE LENGTH = 16" MAX OR <br />5/8" GYP. BOARD <br />BATT INSUL. <br />7/8" CEMENT PLASTER WALL <br />ASSEMBLY AS PER 8/AD-1.0 <br />INTERIOREXTERIOR <br />4" DIA. DRYER EXHAUST VENT <br />w/HOOD TO OUTSIDE <br />EXHAUST SHALL NOT BE LESS THAN 3 FEET <br />FROM OPERABLE WINDOW/DOOR OPENINGS <br />1" <br />1/2"FASTENER FIXED TO EACH <br />STUD AT 90 DEGREES TO <br />FACE, FINISH FLUSH <br />WEATHER BARRIER <br />o/WOOD SHEATING <br />HORIZONTAL SIDING <br />1-HR RATED (AS REQ.) <br />INTERIOREXTERIOR <br />5/8" GYP. BOARD <br />BATT INSUL. <br />STRUCTURAL SHEATING <br />AS REQUIRED <br />JOB NO.SCALE <br />AS NOTED <br />SHEET NO. <br />SHEET TITLE. <br />APPROVALS: <br />THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF <br />THE DRAFTER AND MAY NOT BE REPRODUCED WITHOUT THE <br />DESIGNERS PERMISSION AND UNLESS THE REPRODUCTION CARRIES <br />THE DRAFTERS NAME. ALL DESIGN AND OTHER INFORMATION SHOWN <br />ON THE DRAWINGS ARE FOR USE ON THE SPECIFIC PROJECT ONLY <br />AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION <br />FROM THE DRAFTER. <br />[DESIGN GROUP NAME][DESIGN GROUP NAME][DESIGN GROUP NAME][DESIGN GROUP NAME] <br />1610 W. 7TH ST. LOS ANGELES, CA. 90017 <br />benny@designgroupname.com <br />marino@designgroupname.com <br />8/ <br />2 <br />7 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />7 <br />: <br />4 <br />3 <br />: <br />5 <br />7 <br /> <br />A <br />M <br />AD-1.0 <br />DETAILS <br />[DGN-2200] <br />1621 w 10th ST. & #2 <br />SANTA ANA, CA. <br />10th ADU <br />No. Description Date <br />1 PLANNING - REV 1 05 06 24 <br />SCALE <br />1 1/2" = 1'-0"1FLASHING DETAILS <br />SCALE <br />1 1/2" = 1'-0"2STUCCO SYSTEM <br />SCALE <br />1/2" = 1'-0"3WALL SECTION - SLOPED ROOF w/ SLAB FOUNDATION <br />SCALE <br />1 1/2" = 1'-0"4ROOF - SLOPED <br />SCALE <br />1 1/2" = 1'-0"5ROOF - RIDGE <br />SCALE <br />1 1/2" = 1'-0"6FOUNDATION - WEEP SCREEDSCALE <br />3" = 1'-0"11MOUNTING HEIGHTS TYP. <br />SCALE <br />1 1/2" = 1'-0"7WALL DETAIL - EXTERIOR <br />SCALE <br />1 1/2" = 1'-0"9WALL DETAIL - INTERIOR <br />SCALE <br />1 1/2" = 1'-0"8WALL DETAIL - EXTERIOR 1 HR. <br />SCALE <br />1 1/2" = 1'-0"10WALL DETAIL - TILE INTERIOR <br />SCALE <br />1 1/2" = 1'-0"121HR FIRE RATED EAVE <br />SCALE <br />1 1/2" = 1'-0"13DRYER VENT DETAIL <br />SCALE <br />1 1/2" = 1'-0"14SIDING - CONCEALED FIXING <br />1621 W Tenth St & <br />#29/30/2024
The URL can be used to link to this page
Your browser does not support the video tag.