Laserfiche WebLink
S CM <br />S CM <br />WH <br />DryerWasher <br />Re <br />f <br />r <br />i <br />g <br />e <br />r <br />a <br />t <br />o <br />r <br />SITE DRAINAGE <br />ROOF DRAINAGE <br />SCOPE OF WORK <br />PROPERTY LINE <br />SETBACK <br />FOOTPRINT OR AS <br />PER NOTATION <br />2% <br />AS PER ANNOTATION <br />NOTES : <br />1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR <br />AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER <br />DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES, <br />TRANSFORMER, VAULTS, PUMPS, VALVES, METERS, <br />APPURTENANCES, ETC.) OR TO THE LOCATION OF HOOK-UP. THE <br />CONSTRCUTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER <br />LINES-WHETHER OR NOT THE LINES ARE LOCATED ON THE <br />PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION <br />DELAYS AND/OR ADDITIONAL EXPENSES. <br />2. AN APPROVED SEISMIC GAS SHUT OFF VALVE OR EXCESS FLOW <br />SHUT OFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE ON <br />THE DOWN-STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY <br />CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE <br />CONTAINING THE FUEL GAS PIPING. (PER ORDINANCE 170, 158 AND <br />180,670) SEPARATE PLUMBING PERMIT IS REQUIRED. <br />3. PROVIDE ULTRA-FLUSH WATER CLOSETS FOR ALL NEW <br />CONSTRCUTION. EXISTING SHOWER HEADS AND TOILETS MUST BE <br />ADAPTED FOR LOW WATER CONSUMPTION. <br />4. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A <br />SANITARY SEWER OR TO AN APPROVED SEWAGE DISPOSAL <br />SYSTEM <br />5. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, <br />LAUNDRY TUBS AND WASHING MACHINE OUTLETS SHALL BE <br />PROVIDED WITH HOT AND COLD WATER AND CONNECTED TO <br />APPROVED WATER SUPPLY. <br />6. BATHROOM AND SHOWERS, WALLS ABOVE BATHTUBS WITH A <br />SHOWERHEAD, AND SHOWER COMPARTMENTS SHALL BE FINISHED <br />WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL <br />EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE <br />FLOOR. <br />7. UNIT SKYLIGHTS SHALL BE LABELED BY A LA CITY APPROVED <br />LABEL AGENCY. SUCH LABEL SHAL STATE THE APPROVED LABEL <br />AGENCY NAME, PRODUCT DESIGNATION AND PERFORMANCE <br />GRADE RATING. <br />8. WATER HEATER MUST BE STRAPPED TO WALL. <br />9. FOR EXISTING POOL ON SITE, PROVIDE AN ALARM FOR DOORS TO <br />DWELLING THAT FORM A PART OF THE POOL ENCLOSURE. THE <br />ALARM SHALL SOUND CONTINUOUSLY FOR A MIN. OF 30 SECONDS <br />WHEN THE DOOR IS OPENEND. IT SHALL AUTOMATICALLY RESET <br />AND BE EQUIPPED WITH AMANUAL MEANS TO DEACTIVATE (FOR 15 <br />SECS. MAX.) FOR A SINGLE OPENING. <br />10. FOR EXISTING POOL ON SITE, PROVIDE ANTI-ENTRAPMENT COVER <br />MEETING THE CURRENT ASTM OR ASME FOR THE SUCTION <br />OUTLETS OF THE SWIMMING POOL, TODDLER POOL AND SPA FOR <br />A SINGLE FAMILY DWELLINGS PER ASSEMBLY BILL <br />11. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE <br />LISTED IN ACCORDANCE WITH UL325. <br />12. SMOKE DETECTORS SHALL BE PROVIDED FOR ALL DWELLING <br />UNITS INTENDED FOR HUMAN OCCUPANCY, WHERE A PERMIT IS <br />REQUIRED FOR ALTERATIONS, REPAIS, OR ADDITIONS. <br />13. WHERE A PERMIT IS REQUIRED FOR ALERATIONS, REPAIRS OR <br />ADDITIONS,EXISTING DWELLINGS OT SLEEPING UNITS THAT HAVE <br />ATTACHED GARAGES OR FUEL-BURNING APPLIANCES SHALL BE <br />PROVIDED WITH A CARBON MONOXIDE ALARM. CARBON MONOXIDE <br />ALARMS SHALL ONLY BE REQUIRED IN THE SPECFIC DWELLING <br />UNITS OR SLEEPING UNIT FOR WHICHTHE PERMIT WAS OBTAINED. <br />14. EVERY SPACE INTEDNED FOR HUMAN OCCUPANCY SHALL BE <br />PROVIDED WITH NATURAL LIGHT BY MEANS OF THE EXTERIOR <br />GLAZED OPENINGS IN ACCORDANCE WITH SECTION R303.1 OR <br />SHALL BE PROVIDED WITH ARTIFICIAL LIGHT THT IS ADEQUTE TO <br />PROVIDE AN AVERAGE ILLUMINATION OF 6 FOOT-CANDLES OVER <br />THE AREA OF THE ROOM AT A HEIGHT OF 30 INCHES ABOVE THE <br />FLOOR LEVEL. <br />15. A COPY OF THE EVALUATION REPORT AND/OR CONDITIONS OF <br />LISTING SHALL BE MADE AVAILABLE AT THE JOBE SITE. <br />SIDE SETBACKS <br />(E) 14' - 8 1/2" <br />REAR SETBACK <br />(E <br />) <br /> <br />2 <br />6 <br />' <br /> <br />- <br /> <br />2 <br /> <br />1 <br />/ <br />2 <br />" <br />17 <br />' <br /> <br />- <br /> <br />9 <br /> <br />1 <br />/ <br />2 <br />" <br />28' - 4" <br />FR <br />O <br />N <br />T <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />(E <br />) <br /> <br />2 <br />0 <br />' <br /> <br />- <br /> <br />0 <br />" <br />26 <br />' <br /> <br />- <br /> <br />3 <br />" <br />16' - 11" <br />PROPERTY LINE <br />95.40 ' <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />90 <br />. <br />2 <br />5 <br /> <br />' <br />PROPERTY LINE <br />89.26 ' <br />PROPERTLY LINE <br />94.92 ' <br />23' - 4"12' - 0"6' - 6"7' - 6"14' - 0" <br />18 <br />' <br /> <br />- <br /> <br />3 <br />" <br />21' - 0" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />2' <br /> <br />- <br /> <br />6 <br />" <br />1' <br /> <br />- <br /> <br />6 <br />" <br />1601 SF <br />EXISTING RESIDENCE <br />TO REMAIN <br />252 SF <br />EXISTING <br />COVERED PATIO <br />TO BE DEMOLISHED <br />EXISTING LANDSCAPE TO REMAIN <br />EXISTING LANDSCAPE TO REMAIN <br />278 SF <br />EXISTING <br />GUEST HOUSE TO <br />REMAIN <br />215 SF <br />CONVERT / ADD <br />EXISTING GARAGE <br />TO GUEST HOUSE <br />EXISTING DRIVEWAY TO REMAIN <br />EXISTING LANDSCAPE TO REMAIN <br />W 10TH ST <br />EXISTING LANDSCAPE TO REMAIN <br />EXISTING LANDSCAPE TO REMAIN <br />EXISTING <br />DRIVEWAY TO <br />REMAIN <br />EXISTING DRIVEWAY TO REMAIN <br />EXISTING LANDSCAPE TO REMAIN <br />EXISTING CMU <br />WALL TO REMAIN <br />EXISTING GATE <br />FENCE TO REMAIN <br />EXCESS CONCRETE <br />TO BE ADDRESSED <br />AT A LATER TIME <br />10' - 0" <br />EXISTING <br />LANDSCAPE <br />TO REMAIN <br />EXISTING LANDSCAPE TO REMAIN <br />EXISTING <br />DRIVEWAY <br />APPROACH <br />SEPARATION <br />(E) 15' - 0 1/2" <br />SETBACK <br />(E) 1' - 0" <br />RE <br />A <br />R <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />(E <br />) <br /> <br />9 <br />' <br /> <br />- <br /> <br />0 <br />" <br />EXISTING <br />PERIMETER WALL: <br />6' HIGH MASONRY <br />EXISTING <br />PERIMETER WALL: <br />6' HIGH MASONRY <br />3' - 0" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />0 <br />" <br />4' - 8" <br />JOB NO.SCALE <br />AS NOTED <br />SHEET NO. <br />SHEET TITLE. <br />APPROVALS: <br />THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF <br />THE DRAFTER AND MAY NOT BE REPRODUCED WITHOUT THE <br />DESIGNERS PERMISSION AND UNLESS THE REPRODUCTION CARRIES <br />THE DRAFTERS NAME. ALL DESIGN AND OTHER INFORMATION SHOWN <br />ON THE DRAWINGS ARE FOR USE ON THE SPECIFIC PROJECT ONLY <br />AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION <br />FROM THE DRAFTER. <br />[DESIGN GROUP NAME][DESIGN GROUP NAME][DESIGN GROUP NAME][DESIGN GROUP NAME] <br />1610 W. 7TH ST. LOS ANGELES, CA. 90017 <br />benny@designgroupname.com <br />marino@designgroupname.com <br />LEGEND <br />PLAN NOTES <br />KEYNOTES <br />8/ <br />2 <br />7 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />7 <br />: <br />4 <br />3 <br />: <br />4 <br />9 <br /> <br />A <br />M <br />A-0.0 <br />SITE PLAN <br />[DGN-2200] <br />1621 w 10th ST. & #2 <br />SANTA ANA, CA. <br />10th ADU <br />No. Description Date <br />1 PLANNING - REV 1 05 06 24 <br />SCALE <br />3/16" = 1'-0"1SITE PLAN <br />NOTE: THE APPLICANT/PROPERTY OWNER SHALL BE <br />RESPONSIBLE FOR CONFIRMING ALL EXISTING <br />UTILITY EASEMENTS AND /OR CLEARANCE ON-SITE <br />THAT MAY AFFECT THE PROJECT <br />1621 W Tenth St & <br />#29/30/2024