My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1401 N Tustin Ave Unit# 170 - TI - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tustin Ave
>
1401 N Tustin Ave Unit# 170
>
1401 N Tustin Ave Unit# 170 - TI - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:35:40 AM
Creation date
6/5/2025 7:35:32 AM
Metadata
Fields
Template:
Plan
Permit Number
101120140
Full Address
1401 N Tustin Ave Unit# 170
Text box
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:35 AM
Modified:
6/4/2025 1:35 PM
Text:
www.hilti.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.0.95 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />7 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />SimonMed Santa Ana - Gantry Anchorage <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />7 <br />6/24/2024 <br />6 Warnings <br />• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, <br /> EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the <br /> anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates <br /> the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The <br /> proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for <br /> agreement with the existing conditions and for plausibility! <br />• Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential <br /> concrete failure prism into the structural member. Condition B applies where such supplementary reinforcement is not provided, or where pullout <br /> or pryout strength governs. <br />• Refer to the manufacturer's product literature for cleaning and installation instructions. <br />• For additional information about ACI 318 strength design provisions, please go to https://submittals.us.hilti.com/PROFISAnchorDesignGuide/ <br />• "An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-19, Chapter 17, Section <br /> 17.10.5.3 (a) that requires the governing design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the <br /> case, the connection design (tension) shall satisfy the provisions of Section 17.10.5.3 (b), Section 17.10.5.3 (c), or Section 17.10.5.3 (d). The <br /> connection design (shear) shall satisfy the provisions of Section 17.10.6.3 (a), Section 17.10.6.3 (b), or Section 17.10.6.3 (c)." <br />• Section 17.10.5.3 (b) / Section 17.10.6.3 (a) require the attachment the anchors are connecting to the structure be designed to undergo ductile <br /> yielding at a load level corresponding to anchor forces no greater than the controlling design strength. Section 17.10.5.3 (c) / Section 17.10.6.3 <br /> (b) waive the ductility requirements and require the anchors to be designed for the maximum tension / shear that can be transmitted to the <br /> anchors by a non-yielding attachment. Section 17.10.5.3 (d) / Section 17.10.6.3 (c) waive the ductility requirements and require the design <br /> strength of the anchors to equal or exceed the maximum tension / shear obtained from design load combinations that include E, with E increased <br /> by w0. <br />• Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions (MPII). Reference ACI <br /> 318-19, Section 26.7. <br />Fastening meets the design criteria! <br />13 1401 N Tustin Ave Unit# <br />170 - TI1/27/2025
The URL can be used to link to this page
Your browser does not support the video tag.