Laserfiche WebLink
(1)Tilting axis <br />(2)Longitudinal axis <br />(3)Cable inlet area (889x406 mm) <br />(3B)Alternative cable inlets area <br />(with rear cable cover in option) <br />(4)8 Main anchoring points <br />(5)8 Alternative anchoring points <br />Center of gravity <br />Minimum anchor embedment: 63 mm [2.5 in] <br />(P5487992-2) or 76 mm [3 in] (2106573) <br />ANCHORING/LOADING DISTRIBUTION TO THE FLOOR <br />SCALE 1:20 <br />1 <br />3 <br />3B <br />4 <br />5 <br />Gantry <br />1810 kg <br />[3990 lbs] <br />2 <br />GT1700V Table 445 kg [981 lbs] <br />with 227 kg [500 lbs] patient <br />37 <br />8 <br />[1 <br />4 <br />. <br />9 <br /> <br />i <br />n <br />] <br />63 <br />0 <br /> [ <br />2 <br />4 <br />. <br />8 <br /> <br />i <br />n <br />] <br />878 <br />[34.6 in] <br />1756 <br />[69.1 in] <br />878 <br />[34.6 in] <br />49 <br />8 <br /> [ <br />1 <br />9 <br />. <br />6 <br /> <br />i <br />n <br />] <br />13 <br />2 <br /> [ <br />5 <br />. <br />2 <br /> <br />i <br />n <br />] <br />678 <br /> [26.7 in] <br />678 <br /> [26.7 in] <br />420 <br />[16.5 in] <br />10 <br />[0.4 in] <br />889 <br />[35 in] <br />40 <br />6 <br />[1 <br />6 <br /> <br />i <br />n <br />] <br />88 <br />5 <br />[3 <br />4 <br />. <br />8 <br /> <br />i <br />n <br />] <br />85 <br />4 <br />[3 <br />3 <br />. <br />6 <br /> <br />i <br />n <br />] <br />80 <br />[3 <br />. <br />1 <br /> <br />i <br />n <br />] <br />90 <br />[3 <br />. <br />5 <br /> <br />i <br />n <br />] <br />29 <br />7 <br />. <br />2 <br />[1 <br />1 <br />. <br />7 <br /> <br />i <br />n <br />] <br />232 <br />[9.1 in] <br />NOT TO SCALE <br />FLOOR REQUIREMENTS <br />FINISHED FLOOR REQUIREMENTS <br />·Installation requires a finish floor in the scan and control rooms <br />·The floor surface in the scan room directly under the gantry and table must be level. <br />·The floor levelness tolerance of the floor surface that the gantry and table will rest on is 6 mm [1/4 in] over a 3048 mm [10 ft] distance. <br />·Shims should not be used to compensate for a floor that does not meet this requirement. <br />·Eight or more floor covering openings that are 102 mm [4 in] in diameter are made to ensure the table and gantry rest on a solid surface. <br />These floor penetrations can be sealed if required. <br />·These requirements apply to all installation types. <br />Mi <br />n <br /> <br />1 <br />0 <br />2 <br /> <br />m <br />m <br />[4 <br /> <br />i <br />n <br />] <br />th <br />i <br />c <br />k <br /> <br />c <br />o <br />n <br />c <br />r <br />e <br />t <br />e <br />Leveling pad <br />Adjuster lock ring <br />Gantry/Table <br />stationary base <br />Leveling screw <br />Anchor washer <br />13 mm [0.5 in] min - <br />25 mm [1 in] max <br />after proper torque <br />Anchor bolt <br />GE SUPPLIED TABLE/GANTRY ANCHORS <br />NOTES: <br />·The distance from central line of anchor to the edge of concrete <br />basement of Gantry/Table should not be less than 178 mm [7 in] <br />·Torque anchor to 54 Nm (40 ft-lb) <br />25 mm [1 in] for Table <br />13 mm [0.5 in] for Gantry <br />DateRev /17CT-M233096-FIN-01-A.DWG A 15/FEB/2024OPTIMA CT660 GOLDSEALSimonmed Imaging Inc S3 - Structural Details (1)11 <br />A5 <br />33.6 + 34.8 +19.6 = 88 in = 7.33 ft <br />REFERENCE <br />1401 N Tustin Ave Unit# <br />170 - TI1/27/2025