My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1401 N Tustin Ave Unit# 170 - TI - Plan
PBA
>
Building
>
ProjectDox
>
T
>
Tustin Ave
>
1401 N Tustin Ave Unit# 170
>
1401 N Tustin Ave Unit# 170 - TI - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:35:40 AM
Creation date
6/5/2025 7:35:32 AM
Metadata
Fields
Template:
Plan
Permit Number
101120140
Full Address
1401 N Tustin Ave Unit# 170
Text box
ID:
1
Creator:
Import Agent
Created:
6/5/2025 7:35 AM
Modified:
6/4/2025 1:35 PM
Text:
www.hilti.com
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.0.95 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />SimonMed Santa Ana - Gantry Anchorage <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />6/24/2024 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: Kwik Bolt TZ2 - CS 5/8 (4) hnom3 <br /> Item number: 2210273 KB-TZ2 5/8x6 <br /> Effective embedment depth: hef,act = 4.000 in., hnom = 4.500 in. <br /> Material: Carbon Steel <br /> Evaluation Service Report: ESR-4266 <br /> Issued I Valid: 12/1/2023 | 12/1/2025 <br /> Proof: Design Method ACI 318-19 / Mech <br /> Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. <br /> Anchor plateR : lx x ly x t = 2.100 in. x 2.100 in. x 0.500 in.; (Recommended plate thickness: not calculated) <br /> Profile: no profile <br /> Base material: cracked concrete, Custom, fc' = 3,500 psi; h = 6.000 in. <br /> Installation: hammer drilled hole, Installation condition: Dry <br /> Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present <br /> edge reinforcement: none or < No. 4 bar <br /> Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) <br /> Shear load: yes (17.10.6.3 (c)) <br />R - The anchor calculation is based on a rigid anchor plate assumption. <br />Geometry [in.] & Loading [lb, in.lb] <br />7 1401 N Tustin Ave Unit# <br />170 - TI1/27/2025
The URL can be used to link to this page
Your browser does not support the video tag.