Laserfiche WebLink
Digitally Signed: 2024-03-29 <br />DRAWN BY: <br />DATE DRAWN: <br />SHEET NUMBER:REVISION: <br />302377 <br />EDINGER AVENUE <br />1234 S. MAIN STREET <br />SANTA ANA, CA 92707 <br />EB <br />03/29/24 <br />14845889_D4 <br />C-101 <br />SEAL: <br />DESCRIPTIONREV. DATEBY <br />ATC SITE NUMBER: <br />ATC SITE NAME: <br />SITE ADDRESS: <br />ATC JOB NO: <br />ATC TOWER SERVICES, LLC <br />1 FENTON MAIN STREET <br />SUITE 300 <br />CARY, NC 27511 <br />PHONE: (919) 468-0112 <br />THESE DRAWINGS AND/OR THE ACCOMPANYING <br />SPECIFICATION AS INSTRUMENTS OR SERVICE ARE THE <br />EXCLUSIVE PROPERTY OF AMERICAN TOWER. THEIR USE AND <br />PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE <br />FOR WHICH THEY ARE PREPARED. ANY USE OR DISCLOSURE <br />OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR <br />THE SPECIFIED CARRIER IS STRICTLY PROHIBITED. TITLE TO <br />THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF <br />AMERICAN TOWER WHETHER OR NOT THE PROJECT IS <br />EXECUTED. NEITHER THE ARCHITECT NOR THE ENGINEER WILL <br />BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS <br />PROJECT. CONTRACTOR(S) MUST VERIFY ALL DIMENSIONS AND <br />ADVISE AMERICAN TOWER OF ANY DISCREPANCIES. ANY PRIOR <br />ISSUANCE OF THIS DRAWING IS SUPERSEDED BY THE LATEST <br />VERSION ON FILE WITH AMERICAN TOWER. <br />COMPOUND PLAN <br />0 FOR CONSTRUCTION EB 03/29/24 <br />0 <br />0 10'20' <br />SCALE: 1"=10' (11X17) <br /> 1"=5' (22X34) <br />1 COMPOUND PLAN <br />CONSTRUCTION NOTES: <br />1. ENSURE ALL EXISTING UTILITIES ARE INACTIVE/DISCONNECTED PRIOR TO <br />COMMENCING CONSTRUCTION. <br />2. REMOVE EXISTING 35' MONOPOLE. <br />3. REMOVE ALL FOUNDATIONS TO A DEPTH THAT ALLOWS RESTORATION OF <br />THE TOP SURFACE WITH THE SAME MATERIALS. IF EXISTING PARKING LOT <br />IS ASPHALT, FOUNDATION REMOVAL SHALL NOT EXCEED 3". <br />4. REMOVE METAL FENCE (±25 LF) <br />5. REMOVE ICE-BRIDGE AND POST FOOTINGS. <br />6. REMOVE H-FRAMES AND ASSOCIATED EQUIPMENT. <br />7. REMOVE TELCO AND POWER HAND HOLES, VAULTS. <br />8. REMOVE ALL ELECTRIC AND LOW VOLTAGE CONDUCTORS. <br />9. CUT AND CAP ALL CONDUITS AND GROUNDING SYSTEMS TO A DEPTH <br />THAT ALLOWS RESTORATION OF THE TOP SURFACE. <br />10. RESTORE COMPOUND TO NATURAL GRADE AND CONDITION. <br />11. ALL WORK TO BE COMPLETED IN ACCORDANCE WITH AMERICAN TOWER <br />CONSTRUCTION SPECIFICATIONS SECTION 024110 FOR DEMOLITION AND <br />SECTION 017400 FOR CONSTRUCTION WASTE MANAGEMENT. <br />(TO BE REMOVED) <br />(TO BE REMOVED) (TYP. 3) <br />(TO BE REMOVED) <br />(TO BE REMOVED) <br />(TO BE REMOVED) <br />6RLOPXVWEHFRPSDFWHGWRPLQLPXP <br />6RLO&RPSDFWLRQUHSRUWPXVWEHVXEPLWWHGWR%XLOGLQJGHSWIRUDSSURYDOSULRUILQDO <br />1234 S Main St <br />10/22/2024