Laserfiche WebLink
Job. No. <br />Date <br />Drawn/Checked by <br />Scale <br />FOR PLAN <br />REVIEW ONLY <br />This and all other project documents and all ideas, aesthetics and <br />designs incorporated therein are instruments of service. <br />All project documents are the registered property of ITZEN. (ITZEN) <br />and cannot be lawfully used in whole or in part for any project or <br />purpose except as described in the contractual agreement between <br />ITZEN and Client. ITZEN hereby gives formal notice that any such <br />project document use, reproduction or modification (misuse) is not only <br />unlawful but automatically binds all parties involved with misuse to fully <br />indemnify and defend ITZEN and ITZEN's Consultants to the maximum <br />legal extent against all losses, demands, claims or liabilities arising <br />directly or indirectly from project document misuse. <br />Project documents describe design intent of work and are not a <br />representation of as-built or existing conditions. ITZEN and ITZEN's <br />Consultants make no representations concerning the accuracy of <br />documents and are not responsible for any discrepancies between <br />project documents and the existing conditions. <br />Copyright 2020C <br />mailing: <br />1800 N. Bristol Street #C-418 <br />Santa Ana CA 92706 <br />714-716-5042 <br />sayhello@ITZEN.com <br />www.ITZEN.com <br />. <br />PR <br />I <br />N <br />T <br /> <br />D <br />A <br />T <br />E <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />S <br />t <br />a <br />t <br />u <br />s <br />: <br />CONSULTING STRUCTURAL ENGINEERS <br />3198-G AIRPORT LOOP DRIVE <br />COSTA MESA, CA 92626 <br />PHONE: (714) 556-5475 <br />. <br />CROSS ENGINEERING <br />No. 3886 <br />STRUC T URAL <br />K <br />IRK D .CROSS <br />R <br />EGISTEREDPROFESSIONALENGINEER <br />STATEOF CALIFORNIA <br />. <br />4/ <br />4 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />1 <br />: <br />4 <br />5 <br />: <br />1 <br />3 <br /> <br />A <br />M <br />CE 24-101 <br />02-02-2024 <br />CE <br />AS <br />S <br />I <br />S <br />T <br />A <br />N <br />C <br />E <br /> <br />L <br />E <br />A <br />G <br />U <br />E <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />10 <br />3 <br />7 <br /> <br />W <br />E <br />S <br />T <br /> <br />F <br />I <br />R <br />S <br />T <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />ME <br />C <br />H <br />A <br />N <br />I <br />C <br />A <br />L <br /> <br />E <br />Q <br />U <br />I <br />P <br />M <br />E <br />N <br />T <br /> <br />S <br />C <br />R <br />E <br />E <br />N <br />STRUCTURAL <br />GENERAL NOTES <br />S0.1 <br />AG <br />E <br />N <br />C <br />Y <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />STRUCTURAL SHEET INDEX <br />SHEET <br />NO SHEET TITLE <br />CURRENT <br />REVISON <br />S0.1 STRUCTURAL GENERAL NOTES <br />S1.1 TYPICAL STRUCTURAL DETAILS <br />S2.2 ROOF FRAMING PLAN <br />S3.1 STRUCTURAL DETAILS <br />ABBREVIATIONS <br />A.B. ANCHOR BOLT <br />ABV. ABOVE <br />ATR ALL THREADED ROD <br />BAR REINFORCING BAR <br />BD BOARD <br />BLKG. BLOCKING <br />BLW. BELOW <br />BM BEAM <br />B.N. BOUNDARY NAIL <br />B.W. BOTH WAYS <br />CF CONTINUOUS FOOTING <br />CIDH CAST-IN-DRILLED HOLE <br />CJ CEILING JOIST <br />CL CENTERLINE <br />COL. COLUMN <br />CONC. CONCRETE <br />CONT. CONTINUOUS <br />C.P.E. CONT. PANEL EDGES <br />D DEPTH <br />DBL DOUBLE <br />DF DOUGLAS FIR <br />DIA. DIAMETER <br />DO DITTO <br />(E) EXISTING <br />E.J. EXPANSION JOINT <br />E.N. EDGE NAIL <br />EQ. EQUAL <br />E.W. EACH WAY <br />FB FLOOR BEAM <br />F.G. FINISH GRADE <br />F.J. FLOOR JOIST <br />FL FLOOR <br />FMG. FRAMING <br />F.N. FIELD NAIL <br />F.O.C. FACE OF CONCRETE <br />F.O.M. FACE OF MASONRY <br />F.O.S. FACE OF STUDS <br />F.P. FULL PENETRATION <br />FTG. FOOTING <br />GA. GAUGE <br />GALV. GALVANIZED <br />GLB GLUE-LAMINATED BEAM <br />GR. BM. GRADE BEAM <br />GWB GYPSUM WALLBOARD <br />GT GIRDER TRUSS <br />H HIGH <br />HDR HEADER <br />HGT. HEIGHT <br />HGR. HANGER <br />HORIZ. HORIZONTAL <br />HT HIP TRUSS <br />K.P. KING POST <br />L LOW <br />LT. WT. LIGHT WEIGHT <br />LVL LAMINATED VENEER <br />LUMBER <br />MAS. MASONRY <br />MAX. MAXIMUM <br />M.B. MACHINE BOLT <br />M.I. MALLEABLE IRON <br />MIN. MINIMUM <br />MLB MICRO LAM BEAM <br />(N) NEW <br />N.G. NATURAL GRADE <br />O/ OVER <br />O/C ON CENTER <br />PJ POUR JOINT <br />PLB PARALLAM BEAM <br />PLWD PLYWOOD <br />P.T. PRESSURE TREATED <br />RB ROOF BEAM <br />REINF. REINFORCING <br />REQ'D REQUIRED <br />RF ROOF <br />RJ ROOF JOIST <br />RR ROOF RAFTER <br />RT ROOF TRUSS(ES) <br />SIM. SIMILAR <br />SIMP. SIMPSON PRODUCT <br />S.M.S. SHEET METAL SCREW <br />SQ SQUARE <br />SS SELECT STRUCTURAL <br />STD. STANDARD <br />STL STEEL <br />SW SHEAR WALL <br />THK. THICK <br />T.N. TOE NAIL <br />T.O.C. TOP OF CONCRETE <br />T.O.L. TOP OF LEDGER <br />T.O.M. TOP OF MASONRY <br />T.O.P. TOP OF PLYWOOD <br />T.O.S. TOP OF SHEATHING <br />T.O.W. TOP OF WALL <br />TS TUBE STEEL <br />TSG TAPPERED STEEL GIRDER <br />TYP. TYPICAL <br />U.O.O. UNLESS NOTED OTHERWISE <br />VERT. VERTICAL <br />W WIDTH OF FOOTING <br />W/ WITH <br />W.P. WEAKENED PLANE JOINT <br />W.W.F. WELDED WIRE FABRIC <br />ø DIAMETER <br />@ AT <br />GENERAL NOTES <br />1. PERFORM CONSTRUCTION AND WORKMANSHIP IN COMPLIANCE WITH THE DRAWINGS, <br />SPECIFICATIONS, AND THE 2022 CALIFORNIA BUILDING CODE (CBC). <br />2. GOVERNING CODE AUTHORITY: CITY OF SANTA ANA, CALIFORNIA. <br />3. THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES AND VERIFY ALL DIMENSIONS <br />PRIOR TO THE START OF CONSTRUCTION. NOTIFY THE STRUCTURAL ENGINEER OF ANY <br />DISCREPANCIES OR INCONSISTENCIES. DO NOT SCALE DRAWINGS. <br />4. ALL DETAILS, SECTIONS, AND NOTEZES SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND <br />SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE, UNLESS NOTED OTHERWISE. SPECIFIC NOTES AND <br />DETAILS ON THE DRAWINGS TAKE PRECEDENCE OVER THESE GENERAL NOTES AND TYPICAL DETAILS. <br />5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND SHALL REPORT ANY <br />DISCREPANCIES TO THE STRUCTURAL ENGINEER. <br />6. ARCHITECTURAL, MECHANICAL ELECTRICAL, AND PLUMBING DRAWINGS ARE TO BE CONSIDERED PART <br />OF THE DOCUMENT PACKAGE, AND ARE TO BE USED TO DEFINE LOCATION AND CONFIGURATIONS <br />INCLUDING BUT NOT LIMITED TO: CONCRETE CURB HEIGHT AND LOCATION, FLOOR DRAINS, SLAB <br />DEPRESSIONS, ROOF OPENINGS, DUCT PENETRATIONS, ELECTRICAL CONDUIT RUNS, CONNECTIONS <br />FOR PIPES, DUCTS AND EQUIPMENT, DOORS, WINDOWS, NON-BEARING INTERIOR AND EXTERIOR <br />WALLS, SLOPES, STAIRS, RAILINGS, AND WATERPROOFING. <br />7. REFER TO THE ARCHITECTURAL SPECIFICATIONS (WHERE APPLICABLE) FOR INFORMATION NOzeT <br />COVERED BY THESE GENERAL NOTES OR THE STRUCTURAL DRAWINGS. <br />8. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS <br />(AND/OR ARCHITECTURAL SPECIFICATIONS, WHERE APPLICABLE) SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT AND STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY OF THE <br />WORK INVOLVED. APPROVAL BY GOVERNING AGENCY DOES NOT CONSTITUTE AUTHORITY TO DEVIATE <br />FROM THE PLANS OR SPECIFICATIONS. <br />9. THE CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS <br />OTHERWISE SHOWN THEY DO NOT INDICATE MEANS AND METHODS OF CONSTRUCTION. <br />CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES ARE THE SOLE <br />RESPONSIBILITY OF THE CONTRACTOR. PROVIDE ADEQUATE ERECTION SHORING, BRACING AND GUYS <br />THAT COMPLY WITH LOCAL STATE, OSHA AND NATIONAL SAFETY STANDARDS. <br />10. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL EXCAVATION PROCEDURES INCLUDING LAGGING, <br />SHORING AND PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES <br />COMPLYING WITH ALL LOCAL STATE, OSHA, AND NATIONAL SAFETY STANDARDS. CONTRACTOR SHALL <br />VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND SHALL REPORT ANY DISCREPANCIES TO <br />THE STRUCTURAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL <br />WORK AND MATERIALS INCLUDING THOSE FURNISHED BY SUB-CONTRACTORS. <br />11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR BRACING AND SHORING ALL EXCAVATIONS, <br />TEMPORARY AND EXISTING STRUCTURES, AND PARTIALLY COMPLETED PORTIONS OF THE WORK TO <br />ASSURE THE SAFETY OF ANY OF ALL WORK AND MATERIALS INCLUDING THOSE PERSONS COMING IN <br />CONTACT WITH THE WORK. <br />12. THE CONTRACTOR SHALL INVESTIGATE THE SITE FOR FILLED EXCAVATIONS OR BURIED STRUCTURES <br />SUCH AS FOUNDATIONS, CESSPOOLS, ETC. IF ANY SUCH STRUCTURES ARE FOUND, THE STRUCTURAL <br />ENGINEER SHALL BE IMMEDIATELY NOTIFIED. <br />13. OBSERVATION VISITS TO THE SITE BY FIELD REPRESENTATIVES OF THE STRUCTURAL ENGINEER DO <br />NOT INCLUDE INSPECTIONS OF THE PROTECTIVE MEASURES, OR METHODS OF CONSTRUCTION. <br />CONSTRUCTION SUPPORT SERVICES PERFORMED BY REPRESENTATIVES OF THE STRUCTURAL <br />ENGINEER SHALL BE DISTINGUISHED FROM CONTINUOUS AND DETAILED INSPECTION SERVICES <br />PERFORMED BY OTHERS. OBSERVATION VISITS TO THE SITE BY THE ENGINEER'S FIELD <br />REPRESENTATIVE SHALL NEITHER BE CONSTRUED AS INSPECTION NOR APPROVAL OF CONSTRUCTION. <br />14. FOR PROPER FILED OBSERVATION BY THE STRUCTURAL ENGINEER, THE STRUCTURAL ENGINEER <br />SHALL BE NOTIFIED OF THE VARIOUS CONSTRUCTION PHASES. <br />15. DURING AND AFTER CONSTRUCTION, BUILDER AND /OR OWNER SHALL KEEP LOADS ON STRUCTURE <br />WITHIN THE LIMITS OF DESIGN LOADS. <br />16. ALL CODES AND SPECIFICATIONS NOTED ON THESE DRAWINGS SHALL BE THE LATEST APPROVED <br />EDITIONS AND REVISIONS BY THE GOVERNING CODE AUTHORITY HAVING JURISDICTION OVER THIS <br />PROJECT. <br />17. THE CONTRACTOR SHALL REVIEW AND STAMP ALL SHOP DRAWINGS PRIOR TO SUBMISSION TO THE <br />STRUCTURAL ENGINEER. REVIEW THE SHOP DRAWINGS FOR COMPLETENESS AND COMPLIANCE WITH <br />THE CONTRACT DOCUMENTS AND SPECIFICATIONS. SUBMIT A WRITTEN REQUEST TO THE <br />STRUCTURAL ENGINEER FOR APPROVAL OF ANY MODIFICATION OR SUBSTITUTION. SUBSTITUTIONS <br />AND MODIFICATIONS MUST BE APPROVED PRIOR TO SUBMISSION OF THE SHOP DRAWINGS TO THE <br />STRUCTURAL ENGINEER. CLOUD THE SHOP DRAWINGS AT LOCATIONS OF ALL zeMODIFICATIONS OR <br />SUBSTITUTIONS. MAINTAIN A COPY OF ALL APPROVED SHOP DRAWINGS AT SITE DURING <br />CONSTRUCTION. <br />18. SHOP DRAWINGS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT, ARCHITECT AND STRUCTURAL <br />ENGINEER PRIOR TO FABRICATION WITH SUFFICIENT TIME FOR REVIEW OF DESIGN INTENT (MINIMUM <br />OF 10 WORKING DAYS). <br />19. ALL ASTM DESIGNATIONS SHALL BE AS AMENDED TO DATE UNLESS NOTED OTHERWISE. <br />20. IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS OR DETAILS ON THE <br />STRUCTURAL DRAWINGS. <br />21. VIBRATIONAL EFFECTS OF MECHANICAL EQUIPMENT HAVE NOT BEEN CONSIDERED BY THE <br />STRUCTURAL ENGINEER. <br />22. NO FRAMING OF ANY TYPE SHALL BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES. <br />23. GRADING AND DRAINAGE: ALL PAVING, FLAT WORK AND PLANTERS NEXT TO BUILDING SHALL BE <br />PROPERLY GRADED TO CARRY WATER AWAY FROM BUILDINGS. <br />24. NO CHANGES ARE TO BE MADE TO THESE PLANS WITHOUT THE KNOWLEDGE AND CONSENT OF THE <br />STRUCTURAL ENGINEER WHOSE SIGNATURE APPEARS HEREON. <br />25. THE RESPONSIBLE DESIGN ENGINEER SHALL PROVIDE (A SHOP STAMP) AND REVIEW THE DESIGN, <br />PLANS, CONSTRUCTION DETAILS AND SPECIFICATIONS FOR ALL PREFABRICATED. <br />FOUNDATION <br />1. REFER TO SOIL INVESTIGATION BY: 2022 CBC MINIMUM VALUES DATED: 2022 <br />2. ALLOWABLE SOIL PRESSURE 1,500 PSF WITH INCRESASES PER GEOTECH REPORT <br />3. CARRY ALL FOOTINGS A MINIMUM OF 24”INTO NATURAL GRADE OR APPROVED <br />COMPACTED FILL. <br /> <br />4. ALL FOOTINGS SHALL BE INSPECTED BY THE BUILDING DEPARTMENT PRIOR TO <br />POURING CONCRETE. <br />5. ALL WATER SHALL BE REMOVED FROM FOUNDATION EXCAVATIONS PRIOR TO <br />POURING CONCRETE. <br />6. THE FOLLOWING NOTES FROM THE SOILS REPORT SHALL APPLY TO ALL FOUNDATION <br />WORK <br />BUILDING DESIGN INFORMATION <br />1. GENERAL DATA: <br />ROOF LIVE LOAD = 20 psf (At ≤ 400sf) <br />ROOF LIVE LOAD = 16 psf (400sf < At ≤ 600sf) <br />ROOF LIVE LOAD = 12 psf (At > 600sf) <br />2. WIND DESIGN DATA: <br /> BASIC WIND SPEED = 95 mph (3-sec. peak gust) <br />WIND IMPORTANCE FACTOR I = 1.00 <br />OCCUPANCY CATEGORY = II <br />WIND EXPOSURE = B <br />3. EARTHQUAKE DESIGN DATA : <br />SEISMIC IMPORTANCE FACTOR I = 1.00 <br />OCCUPANCY CATEGORY = II <br />SEISMIC DESIGN CATEGORY = D <br />BASIC SEISMIC-DESIGN PARAMETERS: <br />Ss = 1.295 S1 =0.462 <br />SDS = 1.036 SD1 = 0.462 <br />TESTS AND INSPECTIONS <br />1. DEPUTY INSPECTORS ARE REQUIRED TO BE LISTED BY THE BUILDING DEPARTMENT. <br />2. PROVIDE ALL STRUCTURAL MATERIAL FROM TESTED STOCK FURNISH COPIES OF TEST REPORTS TO <br />ARCHITECT AND GOVERNING CODE AUTHORITY UPON REQUEST. <br />3. SEE SPECIFICATIONS FOR ADDITIONAL TEST AND INSPECTION REQUIREMENTS. <br />4. THE USE OF ROLLED STEEL SECTIONS, BOLTS, AND OR REBAR MANUFACTURED OUTSIDE THE UNITED <br />STATES WILL REQUIRE VERIFICATION THAT THE PRODUCTS COMPLY WITH APPLICABLE ASTM <br />STANDARD. FOREIGN STEEL WILL REQUIRE MILL CERTIFICATES, AND REPRESENTATIVE TESTING BY <br />AGENCIES APPROVED BY THE GOVERNING CODE AUTHORITY TO DEMONSTRATE COMPLIANCE. ALL <br />FOREIGN BOLTS AND CONNECTORS SHALL BE APPROVED BY THE GOVERNING CODE AUTHORITY. <br />5. A TESTING LABORATORY SHALL PROVIDE CONTINUOUS INSPECTION, COMPLYING WITH CHAPTER 17 <br />OF THE 2022 CALIFORNIA BUILDING CODE FOR THE FOLLOWING: <br />A. FIELD WELDING <br />B. STEEL MOMENT FRAMES <br />C. STRUCTURAL OBSERVATION FOR SHEAR WALLS AND SHEAR WALL POST ANCHORS <br />D. CONCRETE AND REINFORCING STEEL WHEN SPECIFIED COMPRESSIVE STRENGTH EXCEEDS <br />2500 PSI <br />E. EXPANSION AND EPOXY ANCHORS. <br />F. ALL CONCRETE MASONRY (CMU) CONSTRUCTION <br />ADDITIONAL NOTES: <br />1. The special inspections identified on plans are, in addition to, and not a substitute for, <br />those inspections required to be performed by a City's building inspector. <br />STRUCTURAL OBSERVATION NOTES: <br />1. STRUCTURAL OBSERVATION PROGRAM IS REQUIRED FOR THIS PROJECT <br />PER 2022 CBC SEC. 1704.5. STRUCTURAL OBSERVATION CORRECTION <br />REPORTS SHALL BE GENERATED BY THE SER. THE FOLLOWING STAGES OF <br />CONSTRUCTION SHALL BE OBSERVED: <br />CONCRETE:ALL FOOTINGS AND SLABS -PRE-POUR <br />SHEAR WALLS:ALL SHEAR WALLS & THE SEISMIC FORCE <br />RESISTING SYSTEM <br />STRUCTURAL STEEL FRAMES:ALL MOMENT FRAMES AND STEEL COLUMNS <br />FINAL FRAMING CONDITIONS:THE FINAL FRAMING CONDITIONS SHALL BE <br />OBSERVED FOR COMPLIANCE WITH THE <br />RECORD DOCUMENTS. <br />WOOD <br />1. ALL WOOD CONSTRUCTION PER 2022 CALIFORNIA BUILDING CODE, CHAPTER 23. <br />2. ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR-LARCH, UNLESS NOTED OTHERWISE, AND <br />CONFORM TO THE GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION. <br />A. 2x LUMBER GRADE #2 <br />B. 4x LUMBER GRADE #2 <br />C. 6x BEAMS, LEDGERS AND POSTS GRADE #1 <br />D. STUDS (U.N.O. ON PLANS) <br />E. FROM 0 FT. TO 8 FT 2x4 STUD GR. <br />F. FROM 8 FT. TO 14 FT 2x4 GRADE #2 <br />G. FROM 14 FT. TO 20 FT 2x6 GRADE #2 <br />H. SILL PLATES (P.T.D.F.) CONST OR BETTER <br />I. TOP & BOTTOM PLATES CONST OR BETTER <br />J. BLOCKING STD OR BETTER <br />REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL APPEARANCE REQUIREMENTS. <br />3. INTERIOR NON-BEARING WALL HEADER SCHEDULE: (U.N.O. ON PLANS) <br />A. TO 4'-0" 4x4 #2 <br />B. TO 7'-0" 4x6 #2 <br />C. TO 10'-0" 4x8 #2 <br />D. TO 13'-0" 4x10 #2 <br />E. TO 16'-0" 4x12 #2 <br />4. ALL SHEATHING SHALL BE STAMPED BY THE AMERICAN PLYWOOD ASSOCIATION (APA) AND SHALL <br />CONFORM TO THE U.S. PRODUCT STANDARD (PS 1 - 95) WITH EXTERIOR GLUE. COMPOSITE OR NON <br />VENEERED PANELS: COMPLY WITH NATIONAL RESEARCH BOARD REPORT NER-108. SUBFLOOR <br />ADHESIVE: APA SPECIFICATION AFG-01. INSTALL PLYWOOD AND NON-VENEERED PANELS PER APA <br />CONSTRUCTION GUIDE, LATEST EDITION. SEE STRUCTURAL FRAMING PLANS FOR THICKNESS AND <br />TYPE OF FLOOR AND ROOF SHEATHING. SEE SHEAR WALL NOTES FOR SIZE AND TYPE OF WALL <br />SHEATHING (PS 1 - 95). <br />5. NAILING OF HORIZONTAL AND VERTICAL DIAPHRAGMS SHALL BE INSPECTED AND APPROVED BY THE <br />BUILDING DEPARTMENT PRIOR TO COVERING. <br />6. ALL NAILS USED IN TIMBER-TO-TIMBER CONNECTIONS SHALL BE COMMON OR COATED SINKER NAILS <br />AND NAILING SHALL CONFORM TO THE APPLICABLE BUILDING CODE. ALL NAILS CONNECTING PRE- <br />MANUFACTURED METAL ITEMS (CONNECTORS, HANGERS, STRAPS, ETC.) TO TIMBER SHALL CONFORM <br />TO THE MANUFACTURER'S CATALOGUE AND APPLICABLE ICC REPORTS. <br />7. ALL STUD WALLS SHALL HAVE FIRE BLOCKING AT 10'-0" O/C MAXIMUM. <br />8. WHERE WOOD IS IN CONTACT WITH CONCRETE OR MASONRY, USE PRESSURE TREATED DOUGLAS FIR <br />OR SHEET METAL CONNECTORS. <br />9. UNLESS OTHERWISE SPECIFIED, ALL SILL PLATES IN CONTACT WITH CONCRETE OR MASONRY <br />SHALL BE BOLTED TO THE CONCRETE OR MASONRY WITH 1/2" DIA. BOLTS AT 4'-0" O/C. <br />NOTE: <br />A. ALL BOLTS SHALL EXTEND A MINIMUM OF 7" INTO FOOTING, WITH 5" MIN. INTO THE FIRST <br />POUR OF CONCRETE. <br />B. PROVIDE A MINIMUM OF 2 ANCHOR BOLTS PER PIECE OF SILL PLATE WITH ONE BOLT <br />LOCATED WITHIN 12" OF THE END. <br />C. AT INTERIOR WALLS, BOLTS MAY BE SUBSTITUTED WITH 0.15" DIA. POWDER DRIVEN PINS <br />AT 32" O/C UNLESS NOTED OTHERWISE. (RAMSET “1500 SERIES” INSTALLED PER ICC ESR-1799, <br />HILTI "X-DNI" INSTALLED PER ICC ESR-1663, OR EQ.). SHOT PINS SHALL NOT BE <br />INSTALLED UNTIL CONCRETE HAS CURED FOR 7 DAYS MINIMUM. AT TWO-POUR <br />FOUNDATIONS, 2nd POUR SHALL HAVE 4-3/4" MIN. THICKNESS AT SHOT PIN LOCATIONS. <br />10. ALL BOLT HEADS AND NUTS WHICH BEAR AGAINST THE FACE OF WOOD MEMBERS SHALL BE PROVIDED <br />WITH WASHERS. <br />11. PROVIDE MULTIPLE STUDS FOR SOLID BEARING AT ENDS OF MISCELLANEOUS BEAMS OR GIRDER <br />TRUSSES WHERE POSTS ARE NOT SHOWN. <br />12. HOLES IN STRUCTURAL MEMBERS FOR PIPES AND CONDUITS SHALL COMPLY WITH THE BUILDING CODE <br />AND THE TYPICAL DETAILS ON S1.1 SHEET. <br />13. PROVIDE DOUBLE FLOOR JOISTS UNDER PARALLEL PARTITIONS. <br />14. SOLID BLOCK AT BEARING WALLS, UNDER PERPENDICULAR PARTITIONS AND ELSEWHERE AS <br />REQUIRED PER 2022 CBC 2308.8.4. <br />15. MINIMUM SPLICE NAILING OF DOUBLE PLATES SHALL BE AS FOLLOWS UNLESS OTHERWISE SPECIFIED: <br />(12)16d EACH SIDE OF SPLICE WITH NO ADJACENT SPLICE WITHIN 4'-0". (SEE TYPICAL DETAIL ON SD1 <br />SHEET) <br />16. FACE NAIL TWO PIECE BUILT-UP BEAMS WITH 16d AT 12" O/C AT TOP AND BOTTOM. FACE NAIL <br />MEMBERS OF THREE PIECE BUILT-UP BEAMS WITH 16d AT 12" 0/C AT TOP AND BOTTOM TO ALTERNATE <br />SIDES OF BEAM. PROVIDE ADDITIONAL ROW OF NAILING AT ALL BEAMS GREATER THAN 12" DEEP. <br />BOLT BUILT-UP BEAMS OF FOUR OR MORE MEMBERS. (SEE TYPICAL DETAIL ON S1.1 SHEET) <br />17. BALLOON FRAME ALL STUD WALLS AT SLOPING CEILINGS. <br />18. PREDRILL ALL HOLES FOR 20d AND LARGER NAILS, SPIKES AND LAG BOLTS. LEAD HOLES FOR LAGS <br />SHALL BE AS FOLLOWS: <br />A. SHANK PORTION - SAME DIAMETER AND LENGTH AS SHANK. <br />B. THREADED PORTION - 60 TO 75% OF THE DIAMETER OF THREAD AND SAME LENGTH AS <br />THREAD. <br />19. PARALLAM BEAMS SHALL BE CONSTRUCTED, INSTALLED AND MANUFACTURED PER SPECIFICATIONS OF <br />WEYERHAEUSER AND ICC ESR-1387. <br />20. THE PROPERTIES OF MICRO=LAM MEMBERS SHALL BE: <br />E = 2,000,000 PSI, Fb = 2,900 PSI, Fv = 290 PSI. <br />21. PROVIDE 2X3 CROSS BRIDGING OR 2X SOLID BLOCKING AT A MINIMUM OF 8'-0" O/C FOR JOISTS <br />(CONTACT METAL BRIDGING OR EQUAL MAY BE USED) WHERE SHEATHING OR GYP. BD. IS NOT <br />APPLIED TO TOP & BOTTOM OF JOISTS FOR ENTIRE LENGTH OF JOIST. <br />22. ALL PREMANUFACTURED METAL ITEMS (CONNECTORS, HANGERS, STRAPS, ETC.) SHALL BE BY <br />SIMPSON STRONG TIE COMPANY, INC. U.N.O. (SEE NOTE 6 ABOVE CONCERNING NAILING.) <br />23. A MAXIMUM OF 10 % OF LUMBER USED FOR CONSTRUCTION MAY CONTAIN "WANE". THOSE MEMBERS <br />WITH "WANE" SHALL NOT BE USED AT PLYWOOD OR DRY WALL EDGES, SOLID BLOCKING OR AT DOUBLE <br />PLATES. <br />24. BOLT HOLES AT HOLDOWNS SHALL NOT BE MORE THAN 1/16 INCH OVERSIZED AT THE HOLDDOWN TO <br />POST CONNECTION INSPECTOR TO VERIFY. (PER BUILDING DEPARTMENT). <br />25. ALL HOLDOWN CONNECTIONS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL <br />FRAMING. <br />26. PRE-DRILL FOR NAILING WHEN NAIL SPACING RESULTS IN THE WOOD SPLITTING. <br />27. PROVIDE MINIMUM 2x6 WCDF #2 STUDS AT ALL PLUMBING WALLS. <br />28. MOISTURE CONTENT OF ALL STRUCTURAL LUMBER SHALL NOT EXCEED 19% AT TIME OF FABRICATION <br />OR CONSTRUCTION. <br />29. ALL METAL FASTENERS AND CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD SHALL BE <br />HOT-DIPPED ZINC COATED, GALVANIZED, OR STAINLESS STEEL. <br />30. ALL FASTENERS IN FIRE-RETARDANT-TREATED WOOD SHALL BE GALVANIZED OR STAINLESS STEEL. <br />NAILING SCHEDULE <br />CONNECTION NAILING <br />JOIST TO SILL OR GIRDER, TOENAIL (3)-8d <br />BRIDGING TO JOIST, TOENAIL EACH END (2)-8d <br />1”x6” SUBFLOOR OR LESS TO EACH JOIST, FACE NAIL (2)-8d <br />WIDER THAN 1”x6” SUB-FLOOR TO EACH JOIST, FACE NAIL (3)-8d <br />2” SUBFLOOR TO JOIST OR GIRDER, BLIND AND FACE NAIL (2)-16d COMMON <br />SOLE PLATE TO JOIST OR BLK'G, FACE NAIL 16d COMMON AT 16” O/C <br />TOP PLATE TO STUD, END NAIL (2)-16d COMMON <br />STUD TO SOLE PLATE (4)-8d TOENAIL OR <br />(2)-16d COMMON END NAIL <br />STUD TO 3x SOLE PLATE (2)-20d COMMON END NAIL <br />DOUBLE STUDS, FACE NAIL 16d COMMON AT 24” O/C <br />DOUBLED TOP PLATES, FACE NAIL 16d COMMON AT 16” O/C <br />CONTINUOUS HEADER, TWO PIECES 16d COMMON AT 16” O/C <br />ALONG EACH EDGE <br />CEILING JOISTS TO PLATE, TOENAIL (3)-8d <br />CONTINUOUS HEADER TO STUD, TOENAIL (4)-8d <br />CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL (3)-16d COMMON <br />CEILING JOIST TO PARALLEL RAFTERS, FACE NAIL (3)-16d COMMON <br />RAFTER TO PLATE, TOENAIL (3)-8d <br />1” BRACE TO EACH STUD AND PLATE, FACE NAIL (2)-8d <br />1”x8” SHEATHING OR LESS TO EACH BEARING, FACE NAIL (3)-8d <br />WIDER THAN 1”x8” SHEATHING TO EACH BEARING, FACE NAIL (3)-8d <br />BUILT-UP CORNER STUDS 16d COMMON AT 24” O/C <br />2” PLANKS (2)-16d COMMON AT EACH <br />BEARING POINT <br />STRUCTURAL STEEL <br />1. STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN ACCORDANCE <br />WITH THE AISC SPECIFICATION FOR THE DESIGN FABRICATION AND ERECTION OF <br />STRUCTURAL STEEL BUILDINGS (LATEST EDITION), ALL COLUMN AND DOUBLER PLATES <br />SHALL CONFORM TO ASTM A992, FY-50 KSI, AND THE FOLLOWING ASTM STANDARD <br />SPECIFICATIONS, UNLESS NOTED OTHERWISE: <br />ALL STRUCTURAL STEEL UNLESS NOTED BELOW ASTM A36 <br />PIPES ASTM A53, GRADE B (35 KSI) <br />TUBES ASTM A500, GRADE B (46 KSI) <br />ANCHOR BOLTS AND UNFINISHED BOLTS ASTM A307 U.N.O. <br />THREADED ROUND STOCK ASTM A36 <br />HIGH STRENGTH BOLTS SEE NOTE BELOW. <br />2. THE USE OF ROLLED STEEL SECTIONS, AND BOLTS MANUFACTURED OUTSIDE THE <br />UNITED STATES WILL REQUIRE VERIFICATION THAT THE PRODUCTS COMPLY WITH <br />APPLICABLE ASTM STANDARD. FOREIGN STEEL WILL REQUIRE MILL CERTIFICATES, <br />AND REPRESENTATIVE TESTING BY AGENCIES APPROVED BY THE GOVERNING CODE <br />AUTHORITY TO DEMONSTRATE COMPLIANCE. ALL FOREIGN BOLTS AND CONNECTORS <br />SHALL BE APPROVED BY THE GOVERNING CODE AUTHORITY. <br />3. MILL CERTIFICATES SHALL ACCOMPANY ALL STRUCTURAL STEEL. ALL STRUCTURAL <br />STEEL SHALL BE IDENTIFIABLE IN THE FIELD WITH THE CORRESPONDING MILL <br />CERTIFICATES. <br />4. ALL BOLTS SHALL BE UNFINISHED, CONFORMING TO ASTM A307 OF SIZES SHOWN ON <br />DRAWINGS, UNLESS NOTED OTHERWISE. <br />5. HIGH STRENGTH BOLTS: <br />A. PROVIDE HIGH STRENGTH BOLTS, NUTS AND WASHERS COMPLYING WITH <br />ASTM A325. ALL HIGH STRENGTH BOLTS SHALL BE SLIP-CRITICAL HIGH STRENGTH <br />BOLTS (A325-SC) UNLESS NOTED OTHERWISE. <br />B. ASSEMBLE HIGH STRENGTH BOLTS IN COMPLIANCE WITH THE 'SPECIFICATION <br />OF STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS.' 2006 EDITION. <br />C. TIGHTEN A325-N BOLTS TO A SMUG TIGHT CONDITION. TIGHTEN A325-SC BOLTS <br />TO AT LEAST THE MINIMUM PROPER TENSION USING ONE OF THE <br />FOLLOWING INDICATOR TIGHTENING. <br />6. HEADED STUD ANCHORS SHALL BE MANUFACTURED FROM C1015, C1017, OR C1020 <br />COLD DRAWN STEEL CONFORMING TO ASTM A108. STUD SIZE SHALL BE AS NOTED ON <br />PLANS. <br />7. SUBMIT SHOP DRAWINGS TO THE STRUCTURAL ENGINEER FOR REVIEW PRIOR TO <br />FABRICATION. INDICATE A WELDING PROCEDURE FOR DUCTILE MOMENT FRAMES <br />INCLUDING THE SEQUENCE OF WELDING AT GIRDER TO COLUMN AND COLUMN TO <br />BASE PLATE CONNECTIONS AND COLUMN SPLICES AS WELL AS THE SEQUENCE OF <br />WELDING WITHIN EACH FRAME. SHOP DRAWINGS SHALL BE SUBMITTED TO THE <br />BUILDING DEPARTMENT, ARCHITECT AND STRUCTURAL ENGINEER PRIOR TO <br />FABRICATION WITH SUFFICIENT TIME FOR REVIEW OF DESIGN INTENT (MINIMUM OF 14 <br />WORKING DAYS) ALSO SEE NOTE #8, 9 & 10 BELOW. <br />8. A WELDING PROCEDURE SPECIFICATION (W.P.S.) PER A.W.S. D1.1 SHALL BE <br />DEVELOPED BY THE FABRICATOR/ERECTOR AND APPROVED BY THE ENGINEER OF <br />RECORD OR HIS DESIGNEE. THE W.P.S. SHALL INCLUDE THE WELDING PARAMETERS <br />RECOMMENDED BY THE ELECTRODE MANUFACTURER. <br />9. COMPLETE JOINT PENETRATION GROOVE WELDS SHALL HAVE A FILLER METAL WITH A <br />NOTCH TOUGHNESS OF 20 FOOT-POUNDS AVERAGE AT 0 DEGREES FAHRENHEIT. <br />10. WELD STRUCTURAL STEEL IN COMPLIANCE WITH ANSI/AW S D1.1-04 WELDERS SHALL <br />BE CERTIFIED AS REQUIRED BY THE GOVERNING CODE AUTHORITY. WELDING SHALL <br />BE DONE BY THE ELECTRIC ARC PROCESS USING APPROVED COATED RODS. WELDING <br />MAY BE PERFORMED USING THE SUBMERGED ARC PROCESS WITH AUTOMATIC <br />WELDING (SAW-1). USE E-90xx LOW HYDROGEN ELECTRODES FOR WELDING OF <br />REINFORCING STEEL. PERFORM SHOP WELDING BY AN APPROVED FABRICATOR. <br />11. BUILDING STRUCTURAL STEEL IS DESIGNED FOR UNSHORED CONSTRUCTION UNLESS <br />NOTED OTHERWISE. <br />12. CAMBER STRUCTURAL STEEL BEAMS AND GIRDERS SUPPORTING FLOOR LOADS WITH <br />SPANS GREATER THAN 15'-0” L/360 UNLESS NOTED OTHERWISE. DO NOT CAMBER <br />MEMBERS BELOW ELEVATOR ENTRANCE DOORS. <br />13. UNLESS A LARGER SIZE FILLET WIELD IS INDICATED, PROVIDE MINIMUM SIZE OF WELD <br />PER AISC. WELD LENGTHS INDICATED ARE THE NET EFFECTIVE LENGTH REQUIRED. <br />14. FIELD CUTTING OR BURNING OF STRUCTURAL STEEL IS NOT PERMITTED WITHOUT <br />WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER. <br />15. SPLICING OF STRUCTURAL STEEL MEMBERS WHERE NOT DETAILED IS PROHIBITED <br />WITHOUT PROIR APPROVAL. IF APPROVED, THE CONTRACTOR SHALL HAVE THE <br />CONNECTION TESTED BY ULTRASONIC TESTING METHOD BY AN INDEPENDENT <br />TESTING LAB. <br />16. AS REQUIRED APPLY SPRAYED FIREPROOFING OVER STRUCTURAL STEEL WITH <br />MONOKOTE MK6/CBF OR MK/ED AS MANUFACTURED BY W.R. GRACE AND COMPANY AS <br />APPROVED BY ICC ESR-1186. OBTAIN APPROVAL FOR SUBSTITUTE PRODUCTS AS <br />INDICATED IN GENERAL SECTION. HOURLY FIRE RESISTIVE REQUIREMENTS SHALL BE <br />DETERMINED USING TABLE 720.1(1) OF THE CBC AND BUILDING TYPES OF <br />CONSTRUCTION AS INDICATED ON ARCHITECTURAL DRAWINGS. <br />17. WHERE EXPOSED STEEL SURFACES ARE EXPOSED TO VIEW IN THE FINISHED WORK, <br />USE ONLY MATERIALS THAT ARE SMOOTH AND FREE FROM SURFACE BLEMISHES. <br />REMOVE SUCH BLEMISHES BY GRINDING OR WELDING AND GRINDING PRIOR TO <br />CLEANING AND APPLICATION OF FINISHES. <br />18. SHOP PRIME ALL STRUCTURAL STEEL, EXCEPT AT CONNECTION LOCATIONS, AND <br />STEEL WHICH REQUIRES FIREPROOFING. FOR THE PROTECTION OF EXPOSED <br />STRUCTURAL STEEL SEE ARCHITECTURAL DRAWINGS. <br />19. BOLT HOLES IN STEEL SHALL BE 1/16 INCH LARGER IN DIAMETER THAN THE NORMAL <br />SIZE OF THE BOLT USED EXCEPT AS NOTED. <br />20. FABRICATOR SHALL REVIEW THE WELDING PROCESS AND MATERIALS TO ENSURE <br />CONFORMANCE WITH THE LATEST SAC/FEMA GUIDELINES AND RECOMMENDATIONS. <br />21. MINIMUM NOMINAL TENSILE STENGTH OF WELD METAL SHALL BE 70 KSI. <br />22. STRUCTURAL STEEL CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND <br />COORDINATING ALL DIMENSIONS AND ELEVATIONS SHOWN ON STRUCTURAL <br />DRAWINGS WITH ARCHITECTURAL DRAWINGS. IN CASE OF CONFLICTS THE ARCHITECT <br />ENGINEER IS TO BE NOTIFIED. <br />23. ALL GROUT UNDER STEEL BEARING PLATES SHALL BE SOLD DRYPACK OR NON-SHRINK <br />GROUT PLACED AS DIRECTED BY THE MANUFACTURER. (F'c = 4,000 PSI MIN.) <br />24. WELDING, OTHER THAN FIELD WELDING, SHALL BE DONE IN AN APPROVED <br />FABRICATOR'S SHOP AND ACCOMPANIED BY A CERTIFICATE OF COMPLIANCE WITH <br />THE APPROVED PLANS. <br />REV DESCRIPTION DATE <br />1031 W 1st St - <br />101119950 & 4013927010/18/2024