11. CARBON MONOXIDE DETECTORS SHALL BE INTERCONNECTED SUCH <br /> THAT THE ACTIVIATION OF ONE ALARM WILL ACTIVIATE ALL ALARMS. <br /> CARBON MONOXIDE DETECTORS SHALL BE "HARD WIRED" AND SHALL BE <br /> EQUIPPED WITH BATTERY BACK UP. <br />10. AT BEDROOMS PROVIDE ONE OPENABLE ESCAPE WINDOW OR DOOR <br />MEETING ALL OF THE FOLLOWING: AN OPENABLE AREA OF NO LESS THAN 5.7 SQ. FT., <br />OVER 44 INCHES ABOVE THE FLOOR (CRC 310.4) <br />A MINIMUM CLEAR 24 INCH HEIGHT AND 20 INCH WIDTH, AND A SILL HEIGHT NOT <br />1. COMPLY WITH MANDATORY MEASURES ATTACHED. SEE SHEET MF-1R <br />2. LIGHTING IN KITCHEN. ALL LUMINARIES SHALL BE HIGH EFFICACY. <br />3. LIGHTING IN BATHROOMS, GARAGES, LAUNDRY ROOMS AND UTILITY <br /> ROOMS. ALL LUMINARIES SHALL BE HIGH EFFICACY. <br />4. OTHER ROOMS. ALL LUMINARIES SHALL BE HIGH EFFICACY. <br />5. OUTDOOR LIGHTING. ALL LUMINARIES MOUNTED TO THE BUILDING OR TO <br /> OTHER BUILDINGS ON THE SAME LOT SHALL BE HIGH EFFICACY LUMINARIES <br /> AND SHALL BE CONTROLLED BY A PHOTOCONTROL/MOTION SENSOR COMBINATION. <br />6. HIGH EFFICACY LUMINARIES MUST BE PIN BASED. <br /> HIGH EFFICACY LAMP REQUIREMENTS: <br /> LAMP POWER RATING MIN. LAMP EFFICACY <br /> 15 WATTS OR LESS 40 LUMENS PER WATT <br /> 15 TO 40 WATTS 50 LUMENS PER WATT <br /> OVER 40 WATTS 60 LUMNES PER WATT <br />7. OCCUPANCY SENSORS MUST HAVE NO MANUAL OVERIDE, 30 MINUTE MAXIMUM <br /> TIMER AND BE MICROWAVE/ULTRASONIC OR PASSIVE INFRA-RED TYPE. <br />1. ELECTRICAL WORK SHALL COMPLY WITH 2022 CALIFORNIA ELECTRICAL CODE. <br />2. FOR A NEW OR REMODELED KITCHEN PROVIDE SMALL APPLIANCE AND DEDICATED CIRCUITS. <br /> THERE SHALL BE A MINIMUM OF TWO 20-AMPERE DEDICATED COUNTER TOP SMALL APPLIANCE <br /> CIRCUITS WITH OUTLETS LOCATED NO MORE THAN 20" OVER COUNTER TOP (2019 CEC 210.11 AND 210.52) <br />3. NEW OR REMODELED BATHROOMS REQUIRE A 20-AMPERE DEDICATED CIRCUIT. THIS CIRCUIT MAY <br /> SUPPLY RECEPTACLES ONLY. (2019 CEC 210.11 (C), 210.52(D) AND 210.23(A)) <br />4. THE CENTER OF 15-20-30 AMPERE RECERTACLES SHALL BE INSTALLED NOT LESS THAN 12" ABOVE THE <br /> FLOOR. 3-210-25 (g) <br />5. CENTER OF SWITCHES TO BE BETWEEN 3 & 4 FEET ABOVE THE FLOOR. <br />6. RECEPTACLES OULETS SHALL BE SPACED AT 12 FT. O. C. MAX, AND SHALL BE LOCATED WITHIN 6 FT. OF <br /> DOORS OPENING. <br />7. PROVIDE OUTDOOR RECEPTACLES WITH WEATHERPROOF COVER AND GROUND FAULT CIRCUIT <br /> INTERRUPTOR (G F C I ). ONE IN FRONT AND ONE IN BACK OF THE DWELLING IS THE MINIMUM <br /> REQUIREMENT. (2019 CEC 210.52) <br />8. ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE PHASE, 15 & 20 AMPERE RECEPTACLE OUTLETS <br /> INSTALLED IN BEDROOM, LIVING ROOM, FAMILY ROOM, DINING ROOM, KITCHEN, AND LAUNDRY ROOM <br /> SHALL BE PROTECTED BY A COMBINATION ARC-FAULT CIRCUIT INTERRUPTER'S) - 2019 CEC 210-12(b). <br />9. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED AND LABELED IN ACCORDANCE <br /> WITH UL325. (R309.4 CRC) <br />LC <br />EQ <br />. <br />EQ <br />. <br />TEMPERED, LAMINATED SAFETY GLASS OR APPROVED PLASTIC. IF GLASS IS USED IT SHALL <br />6. ALL SHOWERS AND TUB-SHOWERS SHALL HAVE EITHER A PRESSURE BALANCE OR A <br />HAVE A MINIMUM THICKNESS OF NOT LESS THAN 1/8" WHEN FULLY TEMPERED OR 1/4" WHEN <br />4. WATERCLOSETS AND SHOWER HEADS SHALL BE LOW CONSUMPTION (1.28 GAL/FLUSH W.C). <br />LAMINATED AND SHALL PASS THE TEST REQUIREMENTS OF UBC STANDARD No 54-2. <br />5. WATERCLOSETS SHALL COMPLY WITH THE MINIMUM CLEARANCES SPECIFIED BELOW. <br />THERMOSTATIC MIXING VALVE. (P.C.420.0) <br />SMOOTH, HARD NON ABSORBENT SURFACES SUCH AS PORTLAND CEMENT, CONCRETE, CERAMIC <br />TILE OR OTHER APPROVED MATERIAL TO A HEIGHT OF NOT LESS THAN 72 INCHES ABOVE THE <br />MATERIALS OTHER THAN STRUCTURAL ELEMENTS USED IN SUCH WALLS SHALL BE MOISTURE <br />2. GLASS ENCLOSURE DOORS AND PANELS SHALL BE LABELED CATEGORY II. DOORS SHALL <br />SWING OUTWARD. THE NET AREA OF THE SHOWER RECEPTOR SHALL BE NOT LESS THAN 1,024 <br />1. SHOWERS AND TUBS WITH SHOWERS SHALL HAVE FLOORS AND WALLS FINISHED WITH <br />3. GLAZING USED IN DOORS AND PANELS OF SHOWER AND TUB ENCLOSURES SHALL BE FULLY <br />SI OF FLOOR AREA, AND ENCOMPASS 30" DIAMETER CIRCLE. <br />RESISTANT. <br />DRAIN INLET. <br />6. WATER HEATER TO BE STRAPPED FOR LATERAL SUPPORT. <br />PROVIDE UPPER & LOWER COMBUSTION AIR PIPE. <br />5. ALL EXTERIOR SWINGING DOORS SHALL BE WEATHER-STRIPPED. <br />1. PROVIDE A SMOKE DETECTOR AT ALL SLEEPING ROOMS <br /> MINIMUM OF 4 INCHES ABOVE THE CONTROLS (P.C. 701.1.2.2) <br /> ONE IN THE LOWER 1/3 OF THE TANK. THE LOWER POINT SHALL BE A <br /> WALL IN TWO PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND <br />9. NEW OR REPLACEMENT WATER HEATERS SHALL BE STRAPPED TO THE <br />7. USE 2"X 6" WOOD STUDS @ 16"O.C. AT PLUMBING WALLS. <br />8. DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE <br />4. ALL EXTERIOR RECEPTACLES AND THOSE INSTALLED IN <br />BATHROOMS, GARAGES AND WITHIN 6 FEET FROM <br />SINK ABOVE COUNTER SHALL BE PROTECTED BY GROUND <br />RELIEF VALVE ON WATER HEATERS AND PIPE DRAINS <br />TO EXTERIOR. ( AS PER CPC 505.4 AND 505.5) <br />3. PROVIDE A COMBINATION TEMPERATURE AMD PRESSURE <br />WITH BATTERY BACK-UP AY NEW ROOMS ONLY. AT <br />EXISTING BEDROOMS USE BATTERY OPPERATED SMOKE <br />2. ALL WATER PIPING WITHIN THE BUILDING STRUCTURE <br />SHALL BE BONDED TOGETHER, MADE ELECTRICALLY <br />CONTINUOUS AND BONDED IN TURN TO THE GROUNDING <br />ELECTRODE CONDUCTOR AT THE SERVICE. <br />AND HALLWAYS; SMOKE DETECTORS SHALL BE HARDWIRE <br />DETECTORS. <br />FAULT PROTECTION ( G.F.I. ) <br />3. GLAZING IN THE FOLLOWING LOCATIONS SHALL BE SAFETY GLAZING <br /> CONFORMING TO THE HUMAN IMPACT LOADS OF SECTION R308.3 (SEE EXCEPTIONS) (R308.4): <br />A. FIXED AND OPERABLE PANELS OF SWINGING, SLIDING AND BI-FOLD DOOR ASSEMBLIES. <br />B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL ADJACENT TO A DOOR WHERE THE <br /> NEAREST VERTICAL EDGE IS WITHIN A 24-INCH ARC OF EITHER VERTICAL EDGE OF THE DOOR IN <br /> A CLOSED POSITION AND WHOSE BOTTOM EDGE IS LESS THAN 60 INCHES ABOVE THE FLOOR OR <br /> WALKING SURFACE. <br />C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL THAT MEETS ALL OF THE FOLLOWING <br /> CONDITIONS: <br />1) EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 SQUARE FEET. <br />2) BOTTOM EDGE LESS THAN 18 INCHES ABOVE THE FLOOR. <br />3) TOP EDGE GREATER THAN 36 INCHES ABOVE THE FLOOR. <br />4) ONE OR MORE WALKING SURFACES WITHIN 36 INCHES HORIZONTALLY OF THE GLAZING. <br />E. GLAZING IN ENCLOSURES FOR OR WALLS FACING HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM <br /> ROOMS, BATHTUBS AND SHOWERS WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS THAN <br /> 60 INCHES MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. <br />G. GLAZING WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 36 INCHES <br /> ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE OF STAIRWAYS, LANDINGS BETWEEN <br /> FLIGHTS OF STAIRS AND RAMPS. <br />H. GLAZING ADJACENT TO THE LANDING AT THE BOTTOM OF A STAIRWAY WHERE THE GLAZING IS <br /> LESS THAN 36 INCHES ABOVE THE LANDING AND WITHIN 60 INCHES HORIZONTALLY OF THE <br /> BOTTOM TREAD. <br />12. PROVIDE EMERGENCY EXIT DOOR OR WINDOW FROM BASEMENT AND/OR <br /> SLEEPING ROOM(S) AND HABITABLE ATTICS. NET CLEAR WINDOW OPENING <br /> AREA SHALL BE NO LESS THAN 5.7 SQ. FT. (EXCEPT AT GRADE FLOOR <br /> OPENING SHALL BE MINIMUM 5.0 SQ. FT.) MIN. NEW WINDOW OPENING HEIGHT <br /> DIMENSION, 24" CLEAR, MIN. NET OPENING WIDTH DIMENSION, 20" CLEAR. <br /> FINISHED SILL HEIGHT MAX 44" ABOVE FLOOR. THE EMERGENCY ESCAPE AND <br /> RESCUE OPENING SHALL BE OPERATIONAL FROM INSIDE OF THE ROOM <br /> WITHOUT THE USE OF KEYS, TOOLS, OR SPECIAL KNOWLEDGE. WINDOW <br /> OPENING CONTROL DEVICES COMPLYING WITH ASTM F2090 SHALL BE <br /> PERMITTED." CRC R310.1 <br />13. WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED THEY SHALL BE <br /> INTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARM <br /> WILL ACTIVATE ALL ALARMS IN THE DWELLING. CRC R314.4 <br />14. COMBINATION SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL BE <br /> LISTED AND APPROVED IN ACCORDANCE WITH UL 217 AND UL 2034. CRC R314.1.1 <br />15. SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL RECEIVE THEIR <br /> PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPED WIT A <br /> BATTERY BACKUP. CRC 314.6,R315.5 <br />16. DRAFTSTOPPING SHALL BE PROVIDED WHERE THERE IS USABLE SPACE ABOVE <br /> AND BELOW THE CONCEALED SPACE OF A FLOOR CEILING ASSEMBLY. THE <br /> DRAFT STOP SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED <br /> SPACE DOES NOT EXCEED <br />1. ALL DUCTS WORK INSTALLED WITH A COMBINED LENGTH OF 40 FEET OR <br /> GREATER SHALL BE REQUIRED TO MEET PACKAGE D, REQUIRE A HERS <br /> RATER, AND SUBMIT. <br />2. CONDENSATE LINES FROM MECHANICAL EQUIPMENT SHALL DISCHARGE <br /> TO A PLUMBING FIXTURE OR STORM DRAIN BY MEANS OF AN INDIRECT <br /> WASTE PIPE. CONDENSATE LINES SHALL NOT DRAIN OVER A PUBLIC WAY. <br /> (310.1 CMC) <br />3. EACH BATHROOM CONTAINING A BATHTUB, SHOWER OR TUB/SHOWER <br /> COMBINATION SHALL BE MECHANICALLY VENTILATED FOR PURPOSES OF <br /> HUMIDITY CONTROL IN ACCORDANCE WITH CMC, CHAPTER 4 AND CGBSC, <br /> CHAPTER 4, DIVISION 4.5 HUMIDITY CONTROL SHALL BE CAPABLE OF <br /> ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF LESS THAN OR <br /> EQUAL TO 50% TO A MAXIMUM OF 80% (R303.3.1 CRC) <br />4.EVERY DWELLING UNIT SHALL BE PROVIDED WITH HEATING FACILITIES <br /> CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF NOT LESS THAN 68°F <br /> AT A POINT 3 FEET ABOVE THE FLOOR AND 2 FEET FROM EXTERIOR WALLS. <br /> THE INSTALLATION OF PORTABLE SPACE HEATERS SHALL NOT BE USED TO <br /> ACHIEVE COMPLIANCE WITH THIS SECTION. SHOW SOURCE OF HEAT ON <br /> PLANS. (R303.9 CRC) <br />5. PROVIDE A SEDIMENT TRAP AT THE LOCATION OF THE WATER HEATER <br /> AND THE FAU OR WHERE A SEDIMENT TRAP IS NOT INCORPORATED AS <br /> PART OF THE APPLIANCE. A SEDIMENT TRAP MUST BE INSTALLED <br /> DOWNSTREAM OF THE APPLIANCE SHUTOFF VALVE AS CLOSE TO THE <br /> INLET OF THE APPLIANCE AS PRACTICAL, BUT BEFORE THE FLEX <br /> CONNECTOR, WHERE USED AT THE TIME OF APPLIANCE INSTALLATION. <br /> SEDIMENT TRAPS ARE NOT REQUIRED AT RANGES, CLOTHES DRYERS, <br /> DECORATIVE VENTED APPLIANCES, OR GAS FIREPLACES. (1313.7 CMC) <br />1. PIPING MATERIAL: <br />WATER: COPPER TYPE "M" OR "L" <br />SEWER/VENTS: ABS SCHED 40 <br />2. WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH <br /> SEC. 604.1 OF THE CA PLUMBING CODE. PEX, CPVC AND OTHER PLASTIC WATER <br /> PIPING SYSTEMS SHALL BE INSTALLED IN ACCO WITH THE REQUIREMENTS OF <br /> SEC. 604 OF THE CPC, INSTALLATION STANDARDS OF APPENDIX I OF THE C <br /> MANUFACTURERS RECOMMENDED INSTALLATION STANDARDS. CPVC WATER <br /> PIPING REQUIRES A CERTIFICA COMPLIANCE AS SPECIFIED IN SEC 604.1.1(D) OF <br /> THE CPC PRIOR TO PERMIT ISSUANCE. <br />3. ALL HOSE BIBS MUST HAVE AN APPROVED ANTI-SIPHON DEVICE. (CPC 603.5.7) <br />4. SHOWER AND TUB-SHOWER COMBINATIONS SHALL BE PROVIDED WITH <br /> INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, OR <br /> COMBINATION PRESSURE BALANCE/THERMOSTATIC MIXING VALVE TYPE THAT <br /> PROVIDED SCALD AND THERMAL SHOCK PROTECTION. THESE VALVES SHALL <br /> CONFORM TO ASSE 1016 OR ASME 112.18.1/CSA B125.1. HANDLE POSITION STOPS <br /> SHALL BE PROVIDED ON SUCH VALVES AND SHALL BE ADJUSTED PER THE <br /> MANUFACTURER'S INSTRUCTIONS TO DELIVER A MAXIMUM MIXED WATER <br /> SETTING OF 120°F. WATER HEATING THERMOSTATS SHALL NOT BE CONSIDERED <br /> A SUITABLE CONTROL FOR MEETING THIS PROVISION. (CPC 408.3). <br />5. ALL NON-COMPLIANT PLUMBING FIXTURES SHALL BE REPLACED WITH <br /> WATER-CONSERVING PLUMBING FIXTURES. (CIVIL CODE SECTION 1101.4(B)) <br /> NONCOMPLIANT PLUMBING FIXTURE MEANS ANY OF THE FOLLOWING: <br />A. ANY TOILET MANUFACTURED TO USE MORE THAN 1.6 GALLONS OF WATER PER FLUSH. <br />B. ANY URINAL MANUFACTURED TO USE MORE THAN ONE GALLON OF WATER PER FLUSH. <br />C. ANY SHOWERHEAD MANUFACTURED TO HAVE A FLOW CAPACITY OF MORE THAN 2.5 <br /> GALLONS OF WATER PER MINUTE. <br />D. ANY INTERIOR FAUCET THAT EMITS MORE THAN 2.2 GALLONS OF WATER PER MINUTE. <br />6. WATER CLOSETS SHALL HAVE AN AVERAGE WATER CONSUMPTION OF NOT MORE THAN 1.28 <br />GALLONS PER FLUSH (411.2 CPC) <br />7. SHOWER HEADS SHALL HAVE A WATER FLOW NOT TO EXCEED 1.8 GALLONS PER MINUTE AT <br /> 80 PSI. (408.2 CPC) <br />8. THE MAXIMUM FLOW RATE OF LAVATORY FAUCETS SHALL NOT EXCEED 1.2 GALLONS PER <br /> MINUTE AT 60 PSI. (403.7 CPC) <br />9. FAUCETS IN KITCHENS SHALL HAVE A WATER FLOW NOT TO EXCEED 1.8 GALLONS PER <br /> MINUTE AT 60 PSI AND MAY TEMPORARILY INCREASE THE FLOW ABOVE THE MAXIMUM RATE, <br /> BUT NOT TO EXCEED 2.2 GALLONS PER MINUTE, AND MUST DEFAULT TO A MAXIMUM FLOW <br />RATE OF 1.8 GALLONS PER MINUTE. (407.2.1.1 CPC) <br />1/2" DRYWALL FINISH <br />SHEARWALL SHEATHING (PER PLAN) <br />7/8" STUCCO EXTERIOR FINISH <br />(PLASTER MIX 1:4 FOR SCRATCH COAT AND 1:5 FOR <br />BROWN COAT, BY VOLUME, CEMENT TO SAND) <br />OVER MOISTURE BARRIER <br />2X4 STUDS @ 16" O.C. <br />INTERIOR <br />R-15 INSULATION <br />EXTERIOR1/2" DRYWALL FINISH <br />R-15+R-5 INSULATION <br />WALL <br />R.R. <br />SHEET <br />CELL: 949-401-3370 <br />INFO@YARDDES.COM <br />Scale <br />SHANI KRISPIN <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />10 <br />2 <br />2 <br /> <br />S <br />. <br /> <br />H <br />I <br />C <br />K <br />O <br />R <br />Y <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />CA <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />DATE <br />SH <br />E <br />E <br />T <br /> <br />T <br />I <br />T <br />L <br />E <br />IRVINE, CA 92618 <br />6 FOXCHASE <br />YARD DESIGN <br />PREPARED BY: <br />AV <br />I <br />V <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />00-G-001 <br />1/16" = 1'-0" <br />GE <br />N <br />E <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br />08/07/2024 <br />APPROVAL STAMP <br />1022 S Hickory St <br />1/9/2025