STRUCTURAL PLAN NOTES <br />FOUNDATION PLAN3 <br />FOUNDATION PLAN NOTES <br />CEILING PLAN1 <br />HEADER SCHEDULE UNO ON PLAN <br />MARK HEADER SIZE JACK STUD SIZE KING STUD SIZE HANGER <br />HDR-1 4x12 DF. NO.1 -4x6 HUC412 <br />HDR-2 4x6 2x4 2x4 - <br />HDR-3 4x8 2-2x4 2x4 - <br />POST SCHEDULE UNO ON PLAN <br />MARK POST SIZE <br />C44 4x4 <br />C46 4x6 <br />JOIST & HANGER SCHEDULE UNO ON PLAN <br />MARK JOIST SIZE HANGER <br />RR-1 2x8 @16" O.C.- <br />CJ-1 2x8 @16" O.C. <br />W/BLK'G@8'-0"- <br />STUD WALL SCHEDULE UNO ON PLAN <br />MAX. HEIGHT INT. WALL EXT. WALL <br />8'-00"2x4 @16" O.C.2x4 @16" O.C. <br />STRUCTURAL & FOUNDATION PLAN SCHEDULE <br />ROOF PLAN2 SCALE: 1/4"=1'-0"SCALE: 1/4"=1'-0" <br />SCALE: 1/4"=1'-0" <br />RR-1 RR-1 <br />C44 <br />C44 <br />C44 <br />W/B <br />C <br />4 <br />0 <br />SW1 <br />(18'-2") <br />SW <br />1 <br />(2 <br />1 <br />' <br />- <br />1 <br />" <br />) <br />4x <br />1 <br />0 <br />4x <br />1 <br />0 <br />6x12 No.1 <br />SW4 <br />(3'-1") <br />1 2 <br />A <br />B <br />HD <br />R <br />- <br />2 <br />1 2 <br />A <br />B <br />1 2 <br />A <br />B <br />HDU <br />5C46 <br />12" <br />12 <br />" <br />12 <br />" <br />C44 <br />W/B <br />C <br />4 <br />MST37 <br />MSTC40 <br />MST37 <br />C44 <br />W/B <br />C <br />4 <br />SW1 <br />(18'-2") <br />SW <br />1 <br />(2 <br />1 <br />' <br />- <br />1 <br />" <br />) <br />SW <br />1 <br />(1 <br />7 <br />' <br />- <br />8 <br />" <br />) <br />HDU <br />5 <br />HDU <br />5 <br />C46 <br />C44 <br />CJ-1 <br />HDR-1 <br />C46 <br />W/B <br />C <br />4 <br />60 <br />12" <br />HUC412 <br />SEE HANGER <br />SCHED. <br />SW4 <br />(3'-1") <br />C.A <br />. <br />W/B <br />C <br />4 <br />0 <br />C46 <br />W/B <br />C <br />4 <br />6HD <br />R <br />- <br />3 <br />(2)SIMPSON <br />MSTA49 <br />AT TOP PLATE <br />HDU <br />5 <br />C46 <br />HDU <br />5C46 <br />1 <br />S1.01 <br />C46 <br />8 <br />S1.23 <br />7 <br />S1.23 <br />SW1 <br />(18'-2") <br />SW <br />1 <br />(2 <br />1 <br />' <br />- <br />1 <br />" <br />) <br />SW <br />1 <br />(1 <br />7 <br />' <br />- <br />8 <br />" <br />) <br />8 <br />S1.23 <br />7 <br />S1.23 <br />6 <br />S1.23 <br />MSTC52 <br />SEE 3/S1.21 <br />TYP. <br />MSTC52 <br />5" SOG ON ENGINEERED FIELD <br />MATERIAL BASED ON ARCH. DWGS. W/ <br />#4@18" EA. WAY. SEE SOG REQUIREMENT <br />NOTES FOR CAPILLARY BREAK <br />REQUIREMENTS. <br />TYP. <br />4 <br />S1.01 <br />TYP. <br />TYP. <br />TYP. <br />9 <br />S1.23 <br />TYP. <br />TYP. <br />C46 C46 C46 <br />S1.23 <br />5 <br />SW <br />1 <br />(1 <br />7 <br />' <br />- <br />8 <br />" <br />) <br />TYP. <br />MST48 <br />HDU <br />5 MST48 <br />INDICATES TENSION STRAP <br />INDICATES SHEARWALL TYPE <br />FOR SHEARWALL SCHEDULE <br />SEE 1/S1.21 <br />INDICATES MINIMUM <br />LENGTH OF SHEARWALL <br />SWXX <br />(#'-#") <br />INDICATES WOOD BEAM <br />INDICATES WOOD HEADER <br />SEE 2/S1.22 FOR MORE <br />INFORMATION <br />RB <br />INDICATES HOLDOWN TYPE X <br />HDR <br />INDICATES WOOD POST MARK, <br />SEE POST SCHEDULE <br />C# <br />HDU <br />X <br />SYMBOL DESCRIPTIONS <br />INDICATES JOIST <br />INDICATES HANGER <br />J# <br /># <br />S#.##INDICATES SECTION <br />INDICATES SHEET NUMBER <br />INDICATES DETAIL <br />NUMBER ON THE SHEET <br />S#.## <br /># <br />INDICATES CALLOUT <br />#INDICATES REVISION ON <br />DRAWINGS <br />INDICATES VIEW# <br />S#.##INDICATES LOAD BEARING WALL <br />BW <br />INDICATES WOOD HEADER <br />SEE HEADER SCHEDULE TABLE <br />ON PLAN <br />HDR-# <br />1. SOIL SUBGRADE REQUIREMENTS, ELEVATION AND SLOPING OF FOUNDATIONS AND SOG, AND <br />CONSTRUCTION REQUIREMENTS ARE NOT PART OF THIS SCOPE OF WORK OR THE LIABILITY OF THE <br />STRUCTURAL ENGINEER. <br />2. IF GEOTECHNICAL REPORT OR CIVIL DWGS. ARE AVAILABLE, CONTRACTOR SHALL REVIEW AND FOLLOW <br />THE GEOTECHNICAL REPORT AND CIVIL DWG. FOR THE CONSTRUCTION OF SOIL SUBGRADE AND SOG. <br />3. IN THE ABSENCE OF GEOTECHNICAL REPORT, OR CIVIL REPORT AND DWGS. THE DETAILS SHOWN ON <br />THESE DWGS. MAY BE CONSIDERED BY THE OWNER/GC ON THEIR OWN RISK. STRUCTURAL ENGINEER <br />SHALL NOT BE RESPONSIBLE FOR ANY DAMAGES THAT MAY OCCUR DUE TO USING THESE <br />RECOMMENDATIONS.THESE ARE GENERAL RECOMMENDATIONS FOR THE CONSTRUCTION OF SOIL <br />SUBGRADE. THESE DETAILS DO NOT CONSIDER THE ACTUAL FIELD CONDITIONS. <br />3.1. SOG AND FOUNDATIONS SHALL BE CONTINUOUSLY SUPPORTED ON UNDISTURBED OR ENGINEERED <br />FILL SOIL. <br />3.2. THE AREA WITHIN THE SOG AND FOUNDATION WALLS SHALL HAVE ALL VEGETATION, TOP SOIL AND <br />FOREIGN MATERIAL REMOVED. <br />3.3. FILL MATERIAL SHALL BE FREE OF VEGETATION AND FOREIGN MATERIAL. THE FILL SHALL BE <br />COMPACTED TO ENSURE UNIFORM SUPPORT OF THE SOG, FOUNDATION, AND THE FILL DEPTHS SHALL NOT <br />EXCEED 24 IN FOR CLEAN SAND OR GRAVEL AND 8 IN FOR EARTH. <br />3.4. AT SOG AREA, REINFORCING STEEL SHALL BE SUPPORTED TO REMAIN IN PLACE FROM THE CENTER TO <br />MIDDLE FOURTH OF THE SLAB FOR THE DURATION OF THE CONC. PLACEMENT. <br />3.5. SCARIFY TOP 12" OR RECOMPAC 4' OVEREXCAVATION PRIOR TO TRENCHING FOR THE UTILITY AND/OR <br />FOUNDATION. 90% COMPACTION REPOR IS REQD. AT THE TIME OF FOUNDATION INSPCTION. DAMP <br />PROOFING, BASE COURSE AND PRE-SATURATION ARE REQUIRED THE SPECIAL INSPECTOR SHALL VERIFY <br />THAT THE IN-PLACE DRY DENSITY OF THE COMPACTED FILL IS NOT LESS THAN 90 PERCENT OF THE <br />MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT DETERMINED IN ACCORDANCE W/ ASTM D1557. <br />3.6. AT SOG AREA, A 4 IN THICK SUB-BASE COURSE CONSISTING OF ½” OR LARGER CLEAN AGGR EGATE. <br />3.7. A 10-MIL VAPOR RETARDER/MOISTURE BARRIER CONFORMING TO THE REQUIREMENTS OF ASTM E1745 <br />GLASS A W/ JOINTS LAPPED NOT LESS THAN 6 IN SHALL BE PLACED BTWN. THE CONC. FLOOR SLAB AND <br />THE BASE COURSE OR THE PREPARED SUBGRADE WHERE NO BASE COURSE EXISTS. UNLESS REQUIRED BY <br />BUILDING OFFICIALS THE MOISTURE BARRIER IS NOT MANDATORY FOR DRIVEWAYS, WALKS, PATIOS AND <br />OTHER FLAT WORK NOT LIKELY TO BE ENCLOSED AND HEATED AT A LATER DATE. <br />4. PROVIDE CONTROL JOINTS AT CL. OF CONC. OR STEEL COLUMNS IF NO CONSTRUCTION JOINTS OCCUR. <br />5. CONTRACTOR TO SUBMIT A JOINTING PLAN TO ARCHITECT FOR REVIEW. <br />6. THE TOP SURFACE OF FOUNDATIONS SHALL BE LEVEL ,UNO ON ARCH. DWG. <br />7. THE BOTTOM SURFACE OF FOUNDATION AND SOG SHALL NOT HAVE A SLOPE EXCEEDING ONE UNIT VER. <br />IN 12 UNITS HOR. <br />8. UNO ON PLANS OR TYPICAL DETAILS, NO HOR. CONSTRUCTION SHALL BE PERMITTED IN THE <br />FOUNDATIONS. ALL OTHER CONSTRUCTION JOINTS SHALL BE SUBMITTED TO SEOR AND ARCH FOR <br />REVIEW. <br />SOG REQUIREMENT NOTES <br />C46HDU <br />5 <br />C46HDU <br />5 <br />CJ-1 <br />S1.21 <br />5 TYP. <br />1 <br />S1.01 <br />2 TYP. <br />1 <br />1. T HESE D R AWING AR E BAS ED ON THE B E S T AV A ILA B L E S OU R CES AND DO NO T A DD RE S S T HE F I ELD <br />CONDITIONS. THE CONTRACTOR SHALL VERIFY ALL FIELD CONDITIONS AND ALL EXISTING STRUCTURAL <br />E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y <br />DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR <br />AND SEOR . NO WOR K S HALL BE P E RF ORMED IN T HE A FFECTED AR EAS UN TIL THE DI SCREP AN CIES A RE <br />RESOLVED. <br />2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS <br />SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR <br />WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY <br />IDENTIFIED. <br />3 . CO N TR AC T O R IS S OLE L Y R ESPO N SI B L E FO R P R O T E C T IO N O F A L L S T R U C T U R AL, N ONS T R UCTUR A L, <br />ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED <br />FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR <br />SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR <br />OWNER. <br />4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN <br />CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER <br />DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS <br />INTO THE SHOP DRAWINGS AND FIELD WORK. <br />5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND <br />LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, <br />WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND SHALL <br />NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM OTHER <br />PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. <br />6. FOR CONSTRUCTION NOTES AND TYPICAL SYMBOLS DESCRIPTIONS, SEE S0 SERIES SHEETS. <br />7. FOR TYPICAL DETAILS, SEE S1 SERIES SHEETS. DETAILS AND SCHEDULES INDICATED AS 'TYPICAL' MAY <br />NOT BE SPECIFICALLY REFERENCED ON DRAWINGS. DETERMINE WHERE EACH TYPICAL DETAIL OR <br />SCHEDULE APPLIES BEFORE PROCEEDING WITH WORK. <br />8. SEE ARCH./CIVIL DWGS. FOR CONCRETE SLAB ELEVATIONS, DEPRESSIONS, SLOPES, OPENINGS, CURBS, <br />DRAINS, TRENCHES, SLAB EDGE LOCATIONS, ETC., AND FOR WALL OVERALL DIMENSIONS, LOCATIONS OF <br />OPENINGS, ETC., NOT INDICATED ON STRUCTURAL DRWGS. <br />9. HOLD-DOWNS& ANCHORS HARDWARE MUST BE SECURED IN PLACE PRIOR TO CALLING FOR FOUNDATION <br />INSPECTION. WET SETTING ANCHORS IS PROHIBITED. <br />10. APPROVED PLATE WASHERS SHALL BE USED FOR HOLD-DOWN CONNECTOR BOLTS INTO WOOD <br />FRAMING. HOLD-DOWNS SHALL BE FINGER TIGHT AND 1/2 WRENCH TURN JUST PRIOR TO COVERING WALL <br />FRAMING. <br />11. STANDING WATER SHALL BE REMOVED FROM THE FOUNDATION EXCAVATIONS PRIOR TO THE <br />CONCRETE PLACING. <br />12. UNO IN ARCH./CIVIL DWGS. SURFACE OUTSIDE THE HOUSE NEEDS TO HAVE 5% SLOPE (UNPAVED <br />SURFACE) & 2% SLOPE (PAVED SURFACE) AWAY FROM THE STRUCTURE. <br />13. FOUNDATION EXCAVATIONS SHALL BE INSPECTED AND APPROVED BY THE GEOTECHNICAL ENGINEER <br />PRIOR TO PLACEMENT OF STEEL, IF HIRED. A MEMO SHALL BE AVAILABLE TO THE CITY INSPECTOR AT TIME <br />OF FOUNDATION INSPECTION. <br />14. ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL PLATE SHALL BE OF HOT-DIPPED <br />ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. <br />15. MINIMUM EDGE DISTANCE FOR ANCHOR BOLTS SHALL BE 1-3/4". ALL ANCHOR BOLTS SHALL INCLUDE A <br />MINIMUM 0.229"X3"X3" STEEL PLATE WASHER. THE HOLE IN THE PLATE WASHER SHALL BE PERMITTED TO <br />BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16" LARGER THAN THE BOLT DIAMETER AND A SLOT <br />LENGTH NOT TO EXCEED 1-3/4", PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE <br />WASHER AND THE NUT. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM <br />PLATE ON THE SIDE(S) FOR SHEATHING WITH SHEAR DESIGN VALUES EXCEEDING 400PLF. <br />16. THE FOUNDATION PLAN SHOWS THE GENERAL LAYOUT OF THE FOUNDATION. FOR LOCALIZED SIZE <br />CHANGES AT THE HOLD-DOWNS, REFER TO TYPICAL DETAILS. AT ALL HOLD-DOWN LOCATIONS, <br />FOUNDATION SHALL BE CONSTRUCTED WITH THE DIMENSIONS SPECIFIED IN TABLE FOR HOLD-DOWN <br />ANCHOR SCHEDULE SEE SHEET S1.01. <br />17. ALL WOOD MEMBERS IN CONTACT WITH MASONRY AND CONCRETE SHALL BE PRESSURE-TREATED AND <br />CONFORM TO THE REQUIREMENT OF "AWPA U1" FOR CATEGORY UC4A OR BETTER. <br />18. WOOD AND WOOD BASED MATERIALS USED RAISED FLOOR SYSTEMS INCLUDING JOISTS AND BEAMS <br />SHALL CONFORM TO THE REQUIREMENTS OF "AWPA U1" FOR CATEGORY UC3B OR HIGHER. <br />19. NO HORIZONTAL COLD JOINTS OTHER THAN THE LOCATIONS SHOWN ON THESE DRAWINGSSHALL BE <br />PERMITTED IN FOUNDATION CONSTRUCTION. ALL CONSTRUCTION JOINTS SHALL BESUBMITTED TO SEOR <br />FOR REVIEW. <br />20. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED <br />NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLKG <br />SHALL BE PROVIDED AT PLYWD JOINTS FOR ALL WALLS. <br />21. SPECIAL SOIL CONDITIONS AND PROPERTIES SUCH AS LIQUEFACTION ZONES; ADJACENT TO OR WITHIN <br />AREAS PRONE TO LANDSLIDE, SLOPED LOTS GREATER THAN 1 UNIT VERTICAL UNITS HORIZONTAL ARE NOT <br />INCLUDED IN THIS SCOPE OF WORKS AND NOT CONSIDERED FOR FOUNDATION DESIGN. OWNER SHALL <br />HIRE A SOIL ENGINEER TO VERIFY THESE CONDITIONS AND THEIR EFFECTS ON STRUCTURAL ELEMENTS. <br />22. CONSTRUCTION BELOW THE RAISED FLOOR AND AT CRAWL SPACE INCLUDING LUMBERS AND TIMBERS <br />SHALL BE GRADE 1 OR BETTER , JOISTS & BEAM THAT ARE AT LEAST 18" ABOVE GROUND SHALL BE <br />CATEGORY 3B OR HIGHER AND POSTS, SILL PLATES AND BEAMS AND JOISTS LESS THAN 18" ABOVE THE <br />GROUND SHALL BE CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. <br />23. ALL CRIPPLE WALLS SHALL BE BRACED. <br />24. ALL TOP AND BOTTOM CONTINUEL/ LONGITUDINAL BARS IN STRIP FOUNDATIONS SHALL HAVE <br />STANDARD HOOKS AT THE ENDS. <br />25. ALL TOP AND BOTTOM DISCONTINUED/ LOCAL BARS ( IN BOTH DIRECTIONS ) AT THE PAD/ <br />ISOLATED FOUNDATIONS SHALL HAVE STANDARD HOOKS AT THE ENDS. <br />26. ALL SOG BARS SHALL HAVE STANDARD HOOKS AT THE ENDS. <br />27. FOR DRAINAGE LAYOUT AND REQUIREMENTS, SEE ARCHITECTURAL/CIVIL DRAWINGS. DRAINAGE IS NOT <br />INCLUDED IN STRUCTURAL ENGINEER'S SCOPE OF WORK. <br />28. WHERE THE STEEL COLUMNS ARE EXPOSED TO WEATHER, BASE PLATES AND COLUMNS UP TO 12" <br />ABOVE THE CONCRETE SLAB SHALL BE COATED WITH MIN. 2 COATS OF MACROPOXY 646. <br />29. ALL PERMANENT STEELS IN CONTACT WITH WEATHER SHALL BE PROTECTED FOR CORROSION. <br />30.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL <br />OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO <br />SEOR. <br />31. FOR ALL BASEPLATES AND STEELS THAT ARE OUTSIDE OR UNDER GROUND, APPLY MIN. 2 COATS OF <br />MACROPOXY 646 WITH MINIMUM 8 MILS THICKNESS. <br />HDU <br />2C44 HDU <br />2 <br />C44 <br />C.A <br />. <br />W/B <br />C <br />4 <br />0 <br />HUC412 <br />SEE HANGER <br />SCHED. <br />S1.23 <br />4 <br />C44 <br />W/B <br />C <br />4 <br />HDU <br />2C44 HDU <br />2 <br />C44 <br />HDU <br />2 <br />C44 <br />HDU <br />2 <br />C44 <br />C44 <br />HANGER SCHEDULE UNO ON PLAN <br />MODEL FACE FASTENERS MEMBER FASTENERS <br />HUC412 (12) 0.162 x 3 1 <br />2"(10) 0.148 x 3 <br />C46 <br />SW4 <br />(3'-1") <br />SW4 <br />(3'-1") <br />C46 <br />SW4 <br />(3'-1") <br />SW4 <br />(3'-1") <br />USE (4)SDS25800 SCREW FOR HDR TO <br />C46 POST AT EACH ENDS. SEE 1/S1.22. <br />1 . THE S E DR A WING AR E BA S E D O N TH E BES T A VA IL AB LE SO UR C E S AND DO N OT A DDR ESS THE FIELD <br />CONDITIONS. THE CONTRACTOR SHALL VER IFY ALL FIELD CONDITIONS AND ALL EXISTING STRUCTURAL <br />E L E M E N T S S P E C I F I E D A S V E R I F I E D I N F I E L D (V .I .F .) P R I O R T O C O M M E N C I N G T H E W O R K . A N Y <br />DISCREPANCIES BETWEEN THESE DRAWINGS AND FIELD CONDITIONS SHALL BE REPORTED TO THE AEOR <br />A ND SE OR. NO WOR K S HALL BE PER FOR MED I N T HE AFFECTED AREAS UNTIL THE DI SCR EPA NCIES AR E <br />RESOLVED. <br />2. NO CUTTING, DRILLING, DEMOLITION OR DESTRUCTIVE WORK ON CONCRETE OR WOOD ELEMENTS <br />SHALL BE PERMITTED UNLESS ALL REINFORCING STEEL INCLUDING PT TENDONS, BEARING WALLS, SHEAR <br />WALLS, BEAMS,AND DIRECTIONS OF JOISTS AND RAFTERS THAT WILL BE AFFECTED ARE POSITIVELY <br />IDENTIFIED. <br />3. C ONT R ACTO R IS S OLELY R E S P ONS I BLE FO R P R OT E C T I O N OF ALL STR UC T U R AL, NO N STR UC T U R AL, <br />ARCHITECTURAL, FINISHING, ELECTRICAL AND MECHANICAL COMPONENTS WHICH ARE NOT DESIGNATED <br />FOR DEMOLITION OR NEW CONSTRUCTION. ANY DAMAGES CAUSED BY THE CONTRACTOR OR <br />SUBCONTRACTORS SHALL BE REPAIRED BY THE CONTRACTOR AT NO COSTS TO THE ENGINEERS OR <br />OWNER. <br />4. STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN <br />CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER <br />DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS <br />INTO THE SHOP DRAWINGS AND FIELD WORK. <br />5. ALL ELEVATIONS, SLOPES, DRAINAGE, DIMENSIONS OF OPENINGS, PENETRATIONS, DEPRESSIONS, AND <br />LAYOUT AND GEOMETRY OF NONSTRUCTURAL ELEMENT SUCH AS BUT NOT LIMITED TO PARTITION, <br />WINDOWS, PLUMBING, ARE NOT INCLUDED IN THE STRUCTURAL ENGINEERING SCOPE OF WORK AND <br />SHALL NOT BE THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER. REFER TO THE DRAWINGS FROM <br />OTHER PROFESSIONS FOR THE INFORMATION MENTIONED ABOVE. <br />6. REVIEW ALL NOTES PROVIDED IN FRAMING LUMBER AND ENGINEERED WOOD PRODUCT SECTION FOR <br />GENERAL REQUIREMENTS AND CONFORMANCE OF STRUCTURAL WOOD. <br />7. FOR TYPICAL DETAILS SEE S1 SERIES SHEETS. <br />8. ROOF SHEATHING OVER ROOF RAFTER/JOISTS NOT SPACED MORE THAN 16" OC. SHALL BE 15/32" OR <br />1/2" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 32/16 WITH EXTERIOR GLUE, (EXPOSURE1 OR <br />EXTERIOR), SQURE EDGE (OR TONGUE-AND-GROOVE). NAILS SHALL BE 8d WITH MINIMUM FASTENER <br />PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT INTERMEDIATE FRAMING (FIELD <br />NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES AND AT SUPPORTED PANEL <br />EDGES SHALL NOT BE MORE THAN 6 IN. <br />9. ROOF SHEATHING OVER RAFTERS/JOISTS OR TRUSSES SPACED AT 24" OC. SHALL BE 19/32" OR 5/8" PS1 <br />OR PS2 CATEGORY, APA RATED SHEATHING, 40/20 WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), <br />SQURE EDGE (OR TONGUE-AND-GROOVE). <br />10. FLOOR SHEATHING SHALL BE 23/32" OR 3/4" PS1 OR PS2 CATEGORY, APA RATED SHEATHING, 48/24 <br />WITH EXTERIOR GLUE, (EXPOSURE 1 OR EXTERIOR), SQURE EDGE (OR TONGUE-AND-GROOVE ).NAILS <br />SHALL BE 10d WITH MINIMUM FASTENER PENETRATION IN FRAMING WOOD FOR 1-3/8 IN. NAIL SPACING AT <br />INTERMEDIATE FRAMING (FIELD NAILING) SHALL NOT BE MORE THAN 12 IN. NAIL SPACING AT BOUNDARIES <br />AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN, U.N.O. ON PLANS. <br />11. BALCONY FRAMES AND SHEATHING SHALL BE EXTRIOR GRADE. BALCONY SHEATHING SHALL BE 3/4" PS1 <br />OR PS2 CATEGORY, APA RATED SHEATHING, 48/24, EXTERIOR, SQURE EDGE (OR TONGUE-AND-GROOVE ). <br />12. ROOF, FLOOR AND BALCONY PANEL EDGES SHALL HAVE APPROVED TONGUE-AND-GROOVE JOINTS OR <br />SHALL BE SUPPORTED WITH BLOCKING. 1-1/2" THICK PANELS WITH 1/4" MINIMUM THICKNESS <br />UNDERLAYMENT OR 1-1/2" OF APPROVED LIGHTWEIGHT CONCRETE PLACED OVER THE SUB-FLOOR, DO <br />NOT REQUIRE BLOCKING AT THE EDGES. <br />13. ALL EXTERIOR WALLS SHALL BE SHEATHED ON THE OUTSIDE OF THE WALL, INCLUDING GABLES, AND <br />THE CONNECTION OF THE SHEATHING TO FRAMING. SHEATHING SHALL BE 15/32" PS1 OR PS2 CATEGORY, <br />APA RATED SHEATHING, STRUCTURAL-I, WITH EXTERIOR GLUE, (EXPOSURE1 OR EXTERIOR), SQURE EDGE. <br />14. ALL SHEATHING SHALL BE LAID CONTINUOUS OVER TWO OR MORE SUPPORTS WITH FACE GRAIN <br />PERPENDICULAR TO SUPPORTS (UNLESS SHOWN OTHERWISE). STAGGER ALL SHEATHING PANELS A <br />MINIMUM OF ONE JOIST BAY. <br />15. UNO PER SHEAR WALL SCHEDULE, OR SHOWN ON THE THESE DRAWINGS ALL SHEATHING SHALL BE <br />NAILED TO THE FARMING AS FOLLOWS: <br />15.1. FASTENERS SHALL BE 10d COMMON NAILS <br />15.2. SPACING AT BOUNDARIES AND AT SUPPORTED PANEL EDGES SHALL NOT BE MORE THAN 6 IN. <br />15.3. SPACING AT INTERMEDIATE FRAMING (FIELD NAILING, F.N.) SHALL NOT BE MORE THAN 12 IN. <br />15.4. FASTENER PENETRATION IN FRAMING WOOD SHALL NOT BE LESS THAN 1-1/2 IN. <br />15.5. BLOCK ALL EDGES <br />15.6. USE 3X LUMBER AT THE CONNECTION OF TWO PANEL EDGES, UNO ON PLANS OR DETAILS. <br />16. ROOF PLYWOOD SHEATHING SHALL BE CONTINUED BENEATH THE CALIFORNIA FRAMING, IF <br />APPLICABLE. <br />17. ALL WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED AT ALL PANEL <br />EDGES. <br />18. BEARING WALLS SHALL BE SHEATHED ON NOT LESS THAN ONE SIDE OR BRIDGING SHALL BE INSTALLED <br />NOT GREATER THAN 4 FEET APART MEASURED VERTICALLY FROM EITHER END OF THE STUD. 2x BLK'G <br />SHALL BE PROVIDED AT PLYWOOD JOINTS FOR ALL WALLS. <br />19. ROOF AND FLOOR DIAPHRAGM NAILING SHALL BE INSPECTED BEFORE COVERING. <br />20. NO PENETRATIONS ARE ALLOWED THROUGH SHEARWALL UNLESS SPECIFICALLY DETAILED ON THESE <br />NOTES. <br />21. ALL POST TO BEAM AND BEAM TO POST SHALL BE CONNECT W/ CCQ/ECCQ UNO ON PLAN. <br />22. ALL BEAMS ARE FLUSH (NOT DROPPED) UNO ON PLAN. <br />23. EXTERIOR CONSTRUCTION INCLUDING BALCONY, PATIO LUMBERS AND TIMBERS SHALL BE <br />PRESSURE-TREATED AND GRADE 1 OR BETTER AND CLASSIFIED FOR EXTERIOR CONSTRUCTION, DECK <br />BOARDS, JOISTS & BEAM ABOVE GROUND SHALL BE CATEGORY 3B OR HIGHER AND POSTS SHALL BE <br />CATEGORY 4A OR HIGHER AS SPECIFIED BY AWPA STANDARD U1. <br />24. PATIO COVER SHEATHING OVER JOISTS NOT SPACED MORE THAN 24" OC. SHALL BE 19/32" APA RATED <br />WITH SPAN RATING 32/16 EXTERIOR EXPOSURE. NAILS SHALL BE 8D WITH MINIMUM FASTENER <br />PENETRATION IN FRAMING WOOD OF 1-3/8 INCHES. NAIL SPACING AT INTERMEDIATE FRAMING FIELD <br />NAILING) SHALL BE MORE THAN 12 IN. NAIL SPACINGAT BOUNDARIES AND AT SUPPORTED PANEL EDGES <br />SHALL NOT BE MORE THAN 6 IN. <br />25. IF EXISTING CONSTRUCTION IS INCLUDED IN THIS SCOPE OF WORK, ABOVE MENTIONED SHEATHING <br />REQUIREMENT SHALL BE VERIFIED FOR EXISTING ROOF, FLOOR, AND WALLS THAT ARE INCLUDED WITH <br />THIS SCOPE OF WORK.SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND <br />CEMENT PLASTER (STUCCO) FOR THE INSTALLATION OF STUCCO AND DRYWALLS. <br />26. SEE TYPICAL WALL DETAILS FOR THE ADDITIONAL INFORMATION ON HEADERS, KING STUDS AND JACK <br />STUDS. <br />27. SEE GYPSUM BOARD AND EXPANDED METAL OR WOVEN WIRE LATH AND PORTLAND CEMENT PLASTER <br />(STUCCO) NOTES FOR THE INSTALLATION OF STUCCO AND DRYWALLS. <br />28. SOLAR PANEL DESIGN AND CONNECTIONS TO THE SUPPORTING ELEMENTS ARE NOT INCLUDED IN THE <br />STRUCTURAL SCOPE OF WORK. A MAXIMUM DEAD-LOAD OF 3 PSF WAS CONSIDERED IN THE STRUCTURAL <br />DESIGN. THE GC SHALL INFORM STRUCTURAL ENGINEER IN WRITING, IF A HEAVIER SOLAR SYSTEM IS USED <br />IN CONSTRUCTION. <br />29.ALL HANGERS ,COLUMN CAPS ,AND COLUMN BASES ARE MINIMUM REQUIREMENTS ,PRIOR TO ORDER ALL <br />OF THEM SHALL BE CHECKED BY THE CONTRACTOR / FRAMER ANY DISCREPANCY SHALL BE REPORTED TO <br />SEOR. <br />30. ALL STEEL CONNECTORS INCLUDING BOLTS, SCREWS AND NAILS USED IN EXTERIOR STRUCTURE OR <br />EXPOSED TO WEATHER SHALL BE STAINLESS STEEL OR HOT-DIP GALVANIZED. FASTENERS IN <br />PRESERVATIVE TREATED WOOD OR FIRE RETARDANT TREATED WOOD SHALL BE OF HOT DIPPED ZINC <br />COATED GALVANIZED STEEL OR STAINLESS STEEL. <br />31. PROVIDE ONE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS <br />AND RAFTERS WITH SPANS GREATER THAN 8 FT BUT LESS THAN 16 FT. THE INTERMEDIATE BLOCKING <br />SHALL BE SPACED MID-SPAN OF THE JOIST. <br />32. PROVIDE TWO INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS <br />AND RAFTERS WITH SPANS GREATER THAN 16 FT BUT LESS THAN 24 FT. THE INTERMEDIATE BLOCKING <br />SHALL BE SPACED 1/3 OF THE SPAN FROM EACH END. <br />33. PROVIDE THREE INTERMEDIATE AND END FULL HEIGHT SOLID BLOCKING ALONG ALL THE JOISTS BEAMS <br />AND RAFTERS WITH SPANS GREATER THAN 24 FT. THE INTERMEDIATE BLOCKING SHALL BE SPACED NOT <br />MORE THAN 8 FT ALONG THE SPAN FROM EACH OTHER. <br />1011 W 2ND ST, SANTA ANA, <br />CA 92703 <br />PROJECT <br />CLIENT <br />0'2'4'8'16' <br />SHEET TITLE <br />SAZAN INC. <br />2610 Vista Del Oro, Newport Beach, CA 92660 <br />JUAN GARSIA <br />S2.01 <br />CLG, ROOF & <br />FOUNDATION PLAN <br />11/19/2024 <br />EXP. 06-30-2026 <br />1011 W Second St <br />5/1/2025