My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1011 W Second St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Second St
>
1011 W Second St
>
1011 W Second St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:15:26 PM
Creation date
6/5/2025 7:35:36 AM
Metadata
Fields
Template:
Plan
Permit Number
101120893
Full Address
1011 W Second St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project <br />1011 <br />Job Ref. <br />Section Sheet no./rev. <br /> 4 <br />Calc. by <br />N.K <br />Date <br />12/12/2023 <br />Chk'd by Date App'd by Date <br />Roof load case 4 - Wind 90, GC pi -0.18, +cpe <br />Zone <br />Ref. <br />height <br />(ft) <br />Ext pressure <br />coefficient cpe <br />Peak velocity <br />pressure qp <br />(psf) <br />Net pressure <br />p <br />(psf) <br />Area <br />Aref <br />(ft2) <br />Net force <br />Fw <br />(kips) <br />A (+ve)9.98 -0.18 11.19 0.30 112.75 0.03 <br />B (+ve)9.98 -0.18 11.19 0.30 112.75 0.03 <br />C (+ve)9.98 -0.18 11.19 0.30 225.49 0.07 <br />D (+ve)9.98 -0.18 11.19 0.30 115.84 0.04 <br />Total vertical net force ;Fw,v = 0.16 kips <br />Total horizontal net force ;Fw,h = 0.00 kips <br />Walls load case 4 - Wind 90, GC pi -0.18, +cpe <br />Zone <br />Ref. <br />height <br />(ft) <br />Ext pressure <br />coefficient cpe <br />Peak velocity <br />pressure qp <br />(psf) <br />Net pressure <br />p <br />(psf) <br />Area <br />Aref <br />(ft2) <br />Net force <br />Fw <br />(kips) <br />A 11.96 0.80 11.19 9.63 211.24 2.03 <br />B 9.98 -0.46 11.19 -2.39 211.21 -0.50 <br />C 9.98 -0.70 11.19 -4.65 200.67 -0.93 <br />D 9.98 -0.70 11.19 -4.65 200.67 -0.93 <br />Overall loading <br />Projected vertical plan area of wall;Avert_w_90 = d H + d2 tan(0) / 4 = 211.21 ft2 <br />Projected vertical area of roof ;Avert_r_90 = 0.00 ft2 <br />Minimum overall horizontal loading;Fw,total_min = pmin_w Avert_w_90 + pmin_r Avert_r_90 = 3.38 kips <br />Leeward net force;Fl = Fw,wB = -0.5 kips <br />Windward net force ;Fw = Fw,wA = 2.0 kips <br />Overall horizontal loading;Fw,total = max(Fw - Fl + Fw,h, Fw,total_min) = 3.4 kips <br /> <br />Page 29 of 108 <br />1011 W Second St <br />5/1/2025
The URL can be used to link to this page
Your browser does not support the video tag.