My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1011 W Second St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Second St
>
1011 W Second St
>
1011 W Second St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:15:26 PM
Creation date
6/5/2025 7:35:36 AM
Metadata
Fields
Template:
Plan
Permit Number
101120893
Full Address
1011 W Second St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
127
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)191 @ 10' 5 1/4"1406 (1.50")Passed (14%)--1.0 D + 1.0 Lr (Alt Spans) <br />Shear (lbs)169 @ 2' 2 5/8"1631 Passed (10%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)418 @ 6' 11/16"1700 Passed (25%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.054 @ 5' 11 7/8"0.314 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) <br />Total Load Defl. (in)0.087 @ 6'0.471 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) <br />System : Roof <br />Member Type : Joist <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 4/12 <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Overhang deflection criteria: LL (2L/360) and TL (2L/240). <br />•A 15% increase in the moment capacity has been added to account for repetitive member usage. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />• At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger <br />• ¹ See Connector grid below for additional information and/or requirements. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Wind Factored Accessories <br />1 - Beveled Plate - DF 3.50"3.50"1.50"103 163 -130 265/-16 Blocking <br />2 - Hanger on 7 1/4" DF beam 3.50"Hanger¹1.50"78 125 -102 203/-14 See note ¹ <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)Continuous <br />Bottom Edge (Lu)End Bearing Points <br />Connector: Simpson Strong-Tie <br />Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories <br />2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d <br />•Refer to manufacturer notes and instructions for proper installation and use of all connectors. <br />Dead Roof Live Wind <br />Vertical Load Location (Side)Spacing (0.90)(non-snow: 1.25)(1.60)Comments <br />1 - Uniform (PSF)0 to 10' 8 3/4"16"12.0 20.0 -16.0 Default Load <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal.Member Length : 11' 2 7/16" <br />MEMBER REPORT PASSED <br />ROOF, RR-1 <br />1 piece(s) 2 x 8 DF No.2 @ 16" OC <br />ForteWEB Software Operator Job Notes 12/19/2023 12:30:03 PM UTC <br />negar kordbache <br />sazan <br />(443) 942-2153 <br />negarkordbache@gmail.com <br />ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 <br />File Name: 1011 W 2nd St Santa Ana, Ca 92703 <br />Page 2 / 23Page 80 of 108 <br />1011 W Second St <br />5/1/2025
The URL can be used to link to this page
Your browser does not support the video tag.