3500 S Bristol St Unit# 100 - 101119098, 20182666 & 40139043 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
3500 S Bristol St Unit# 100
>
3500 S Bristol St Unit# 100 - 101119098, 20182666 & 40139043 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 6:26:27 AM
Creation date
6/5/2025 7:36:36 AM
Metadata
Fields
Template:
Plan
Permit Number
20182666
40139043
101119098
Full Address
3500 S Bristol St Unit# 100
Street Number
3500
Street Direction
S
Street Name
Bristol
Street Suffix
St
Unit Number
100
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
3" MIN. EMBEDMENT <br />#4 REBAR DOWELS @ 24" O.C. MAX. <br />(ALTERNATING) <br />2500psi MIN. CONCRETE INFILL <br />EXISTING SLAB <br />GRAVEL 1" MIN. <br />CONDUIT, REFER TO <br />ELECTRICAL PLAN <br />(TYP.) <br />TRENCH INFILL 3" <br />9" <br />EXISTING WALL TO BE REMOVED <br />DEMOLITION KEY: <br />EXISTING TO REMAIN <br />EXISTING TO BE REMOVED <br />DEMOLITION NOTES: <br />1. ELECTRIC IN WALLS TO BE REMOVED SHALL BE <br />DISCONNECTED AT MAIN PANEL BOARD OR JUNCTION <br />BOX. <br />2. REMOVE ANY EXISTING ELECTRIC AND LIGHTING NOT <br />BEING USED, UNLESS OTHERWISE NOTED (TYP.). <br />3. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE <br />TO CUT AND PATCH SLAB AS REQUIRED FOR NEW <br />ELECTRICAL CONDUITS AND FLOOR BOX(S). VERIFY <br />ALL OR ANY STRUCTURAL MEMBERS WHICH MAY <br />INTERFERE WITH TRENCH. ELECTRICAL CONTRACTOR <br />SHALL IDENTIFY PRECISE LOCATIONS AND DEPTH IN <br />FIELD AS REQUIRED. <br />4. REMOVE ALL EXISTING MECHANICAL EQUIPMENT, <br />DUCTWORK, PLUMBING FIXTURES, PIPING SYSTEMS, <br />ETC., NOT BEING RE-USED. DO NOT JUST ABANDON. <br />(COORDINATE WITH MECHANICAL PLANS) <br />5. REMOVE EXISTING FLOOR FINISHES DOWN TO <br />EXISTING SLAB, UNLESS OTHERWISE NOTED (TYP.). <br />CLEAN, PATCH AND LEVEL EXISTING CONCRETE SLAB <br />AS REQUIRED FOR NEW FINISHES. SEE FINISH PLAN. <br />6. REMOVE ANY EXISTING SUSPENDED CEILING GRIDS, <br />TILES AND HVAC GRILLES, UNLESS OTHERWISE NOTED <br />(TYP.). <br />7. REMOVE ANY EXISTING WALL COVERING FINISH, <br />UNLESS OTHERWISE NOTED (TYP.). <br />8. REMOVE ANY EXISTING INTERIOR SOFFITS, UNLESS <br />OTHERWISE NOTED (TYP.). <br />9. REMOVE ALL DEBRIS FROM ALL ROOMS (TYP.) <br />10. CONTRACTOR SHALL PROVIDE GLASS "PAINT" ON <br />INTERIOR OF ALL STOREFRONT WINDOWS AND <br />DOORS DURING DEMOLITION AND CONSTRUCTION <br />WORK, AND REMOVE AFTER CONSTRUCTION IS <br />COMPLETE. COLOR SHALL BE WHITE BY: <br />GLASSMASK, INC. <br />10818 HAWN FREEWAY <br />DALLAS, TX 75217 <br />PHONE: (403) 735-0775 <br />FAX: (403) 735-0669 <br />E-MAIL: GLASSM@TELUSPLANET.NET <br />11. CONTRACTOR SHALL NOTIFY ARCHITECT <br />IMMEDIATELY IF EXISTING COLUMN LOCATIONS AND <br />SIZES ARE DIFFERENT FROM WHAT OCCURS IN THESE <br />DRAWINGS, AND OF ANY UNDOCUMENTED <br />STRUCTURAL COLUMNS OR CONDITIONS, PIPES, ETC., <br />WHICH ARE LOCATED IN THE TENANT SPACE BUT DO <br />NOT APPEAR IN THESE DRAWINGS, SO DRAWINGS <br />CAN BE REVISED AS MAY BE REQUIRED TO <br />ACCOMMODATE THE AS-BUILT CONDITIONS. <br />12. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE TO <br />SAW CUT AND REMOVE EXISTING CONCRETE SLAB <br />FOR TRENCHING AS REQUIRED FOR NEW PLUMBING <br />FIXTURES; COORDINATE WITH PLUMBING <br />CONTRACTORS TO IDENTIFY PRECISE LOCATIONS <br />AND DEPTH IN FIELD AS REQUIRED. VERIFY ALL OR <br />ANY STRUCTURAL MEMBERS WHICH MAY INTERFERE <br />WITH TRENCH. EXCAVATE ADDITIONAL TRENCH AS <br />REQUIRED TO CONNECT NEW SOIL LINES TO EXISTING <br />MAIN, V.I.F., VERIFY WITH LANDLORD AND EXISTING <br />BUILDING SYSTEM FOR PRECISE LOCATION AND <br />DIRECTION. SEE PLUMBING PLANS. <br />APPROXIMATE TRENCH LOCATION <br />REMOVE EXISTING ELECTRICAL PANELS, SEE DEMOLITION NOTES <br />REMOVE PORTION OF WALL TO PROVIDE <br />OPENING FOR NEW EXTERIOR DOOR, SEE <br />ARCHITECTURAL PLAN <br />EXISTING <br />STOREFRONT TO <br />REMAIN. <br />CUT/TRENCH EXISTING SLAB AS REQUIRED FOR <br />NEW CONDUITS. SEE ELECTRICAL DRAWINGS FOR <br />LOCATION. VERIFY WITH VERIZON PROJECT <br />MANAGER & LANDLORD'S TENANT COORDINATOR <br />PRIOR TO ANY CUTTING. <br />A.3.1 <br />4 <br />REMOVE EXISTING DOOR AND TRANSOM <br />ABOVE ,PREPARE AREA FOR NEW <br />GLAZING, SEE ARCHITECTURAL PLAN. <br />EXISTING STOREFRONT <br />TO REMAIN. <br />EXISTING STOREFRONT TO REMAIN.3'-4" <br />EXSITING EXTERIOR <br />WALL TO REMAIN, TYP. <br />EXISTING COLUMN TO REMAIN, <br />PATCH ANY HOLES <br />EXISTING COLUMN TO REMAIN <br />TO REMAIN <br />EXISTING STOREFRONT <br />TO BE REMOVED <br />EXISTING STOREFRONT <br />EXISTING SILL TO REMAIN <br />BE REMOVED <br />EXIST SILL TO <br />APPROXIMATE LOCATION OF <br />NEW LEASE LINE <br />EXISTING STAIR <br />(N.I.C.) <br />REMOVE EXISTING SAFE RECESSED IN FLOOR, PATCH SLAB. <br />EXISTING STOREFRONT <br />AND ENTRY DOORS TO <br />REMAIN (N.I.C.) <br />FUTURE TENANT <br />(N.I.C.) <br />EXISTING PLANTER TO BE CUT <br />BACK SEE ARCHITECTURAL <br />PLAN FOR NEW LAYOUT <br />EXISTING LANSCAPING IRRIGATION PIPE TO BE <br />RELOCATED, SEE PLUMBING DRAWINGS <br />EXISTING AWNING TO BE <br />REMOVED <br />EXISTING AWNING TO <br />REMAIN, TYP. <br />EXISTING SIGN TO BE <br />REMOVED. COORDINATE WITH <br />VZPM AND LANDLORD <br />EXSITING <br />PERIMETER COLUMN <br />TO REMAIN, TYP. <br />EXISTING AWNINGTO REMAIN <br />APPROXIMATE LOCATION OF EXISTING RTU TO BE REMOVED. <br />EXISTING RTU WEIGHT: 1,796 LB <br />PROPOSED RTU WEIGHT: 760 LB <br />(NEW UNIT WEIGHS LESS THAN EXISTING UNIT, STRUCTURAL <br />MODIFICATION NOT REQUIRED) <br />EXISTING OVERHANG TO <br />REMAIN, TYP. <br />AD.2.0 <br />1 <br />AD.2.02 <br />AD.2.0 <br />3 <br />Kenneth A. Gruskin AIA <br />No. Date Description <br />Consultant: <br />Checked By: <br />Drawn By: <br />Job Address: <br />Drawing Title: <br />Revision Issue: <br />Professional Seal: <br />Drawing Number: <br />2024 Gruskin Architecture + Design, P.C.c <br />This document and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of GRUSKIN ARCHITECTURE + DESIGN, P.C., <br />and is not to be used in whole or in part for any other <br />project without the written authorization of GRUSKIN <br />ARCHITECTURE + DESIGN, P.C. <br />North <br />Arrow: <br />Job Name and Number: <br />Date Issued For <br />All Rights Reserved <br />Client: <br />Landlord: <br />Permit: <br />Bid: <br />Construction: <br />0006261 <br />AR91629 <br />5421 <br />9613 <br />39209 <br />10635 <br />2537 <br />11016 <br />5734 <br />ARC 2596 <br />4674 <br />2666 <br />AI 09999 <br />2796 <br />0401 011223 <br />2572 <br />17680 <br />RA-015432-B <br />025528-1 NY <br />TX <br />VA <br />VT <br />MA <br />MT <br />RI <br />PA <br />NY <br />NJ <br />NH <br />MD <br />LA <br />ME <br />KS <br />FL <br />DE <br />CT <br />AZ <br />AL <br />C-1967WY <br />RA011075GA <br />AR10400066IN <br />C 29898CA <br />NM 004168 <br />ARC-400347CO <br />HI AR 11489 <br />PR 19965 <br />OR 4899 <br />SC 6834 <br />NC 9961 <br />13761OH <br />05713IA <br />WV 3727 <br />IL 001-019152 <br />UT 5881358-0301 <br />ID AR-984459 <br />1301052379MI <br />ARC100723DC <br />WI 9900-005MN 44326 <br />A-3547NE <br />3811AR <br />5967KY 101374TN <br />MS 3860 <br />1666ND <br />A-2005029740MO <br />a4895OK <br />NV 5521 <br />WA 10344 <br />13167AK <br />SD 11532 <br />J: <br />\ <br />V <br />e <br />r <br />i <br />z <br />o <br />n <br />\ <br />0 <br />0 <br /> <br />S <br />t <br />o <br />r <br />e <br />s <br /> <br />b <br />y <br /> <br />S <br />t <br />a <br />t <br />e <br />\ <br />C <br />a <br />l <br />i <br />f <br />o <br />r <br />n <br />i <br />a <br />\ <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />0 <br />6 <br />9 <br /> <br />M <br />e <br />t <br />r <br />o <br /> <br />P <br />o <br />i <br />n <br />t <br />e <br />- <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br />\ <br />2 <br />. <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />2 <br />. <br />4 <br /> <br />C <br />D <br />\ <br />0 <br />0 <br />- <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />0 <br />6 <br />9 <br />- <br />C <br />u <br />r <br />r <br />e <br />n <br />t <br />\ <br />2 <br />0 <br />2 <br />3 <br />- <br />0 <br />0 <br />6 <br />9 <br />- <br />B <br />I <br />M <br />2 <br />3 <br />. <br />r <br />v <br />t <br />2023-0069 <br />Proposed <br />Store Design <br />for: VERIZON <br />Metro Pointe <br />3500 South Bristol Street <br />Suite 100 <br />Santa Ana, CA 92704 <br />3/15/24 <br />3/15/24 <br />DEMOLITION FLOOR <br />PLAN <br />AD.1.0 <br />MB <br />KG <br />8 OF 81 <br />1" = 1'-0"2 TRENCH INFILL DETAIL <br />Version: 050818 <br />1/4" = 1'-0" <br />Version: 070720 <br />1 DEMOLITION FLOOR PLAN <br />3500 S Bristol St Unit# 100 - <br />101119098, 20182666 & <br />401390437/11/2024