GENERAL NOTES
<br />60. FOR PROJECTS INCLUDING THE INSTALLATION OF ARCHITECTURAL DIMMING SYSTEMS,
<br />THE CONTRACTOR SHALL INCLUDE A CUSTOM USER GRAPHICS INTERFACE PACKAGE
<br />INCLUDING WEB/PC BASED SOFTWARE SHOWING FLOOR PLANS WITH DEVICE
<br />LOCATIONS AND ASSOCIATED CONTROL PARAMETERS FOR THE USER TO ADJUST.
<br />61. FOR PROJECTS INCLUDING THE INSTALLATION OF ARCHITECTURAL DIMMING SYSTEMS,
<br />THE CONTRACTOR SHALL SUBCONTRACT A FACTORY AUTHORIZED TECHNICIAN TO
<br />PERFORM THE FOLLOWING:
<br />- TEST AND INSPECT COMPONENTS, ASSEMBLIES, AND EQUIPMENT INSTALLATIONS,
<br />INCLUDING CONNECTIONS.
<br />- STARTUP SERVICE INCLUDING BUT NOT LIMITED TO A COMPLETE INSTALLATION AND
<br />STARTUP CHECKS ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS,
<br />CONFIRM CORRECT COMMUNICATION WIRING, AND PROGRAM THE LIGHTING
<br />CONTROL SYSTEM ACCORDING TO THE APPROVED ZONE CONFIGURATIONS,
<br />DIMMING SCHEDULES, TIME-OF-DAY SCHEDULES, AND INPUT OVERRIDE
<br />ASSIGNMENTS.
<br />- TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN
<br />THE CONTROLS.
<br />- WHEN REQUESTED WITHIN 1 YEAR FROM DATE OF SUBSTANTIAL COMPLETION,
<br />PROVIDE ON-SITE ASSISTANCE IN ADJUSTING SYSTEM TO SUIT ACTUAL OCCUPIED
<br />CONDITIONS. PROVIDE UP TO 2 VISITS TO PROJECT DURING OTHER-THAN-NORMAL
<br />OCCUPANCY HOURS FOR THIS PURPOSE.
<br />62. FOR PROJECTS INCLUDING THE INSTALLATION OF LIGHTING CONTROL SYSTEMS USING
<br />OPERATING SYSTEM SOFTWARE, THE FOLLOWING SOFTWARE SERVICE AGREEMENT
<br />SHALL BE INCLUDED:
<br />- BEGINNING AT SUBSTANTIAL COMPLETION, SERVICE AGREEMENT SHALL INCLUDE
<br />SOFTWARE SUPPORT FOR 2 YEARS.
<br />- AT SUBSTANTIAL COMPLETION, SOFTWARE SHALL BE UPDATED TO THE LATEST
<br />VERSION. SOFTWARE UPGRADES THAT BECOME AVAILABLE WITHIN 2 YEARS FROM
<br />DATE OF SUBSTANTIAL COMPLETION SHALL BE INSTALLED AND PROGRAMMED.
<br />UPGRADING SOFTWARE SHALL INCLUDE OPERATING SYSTEM AND NEW OR REVISED
<br />LICENSES FOR USING SOFTWARE.
<br />63. CONTRACTOR TO BE RESPONSIBLE FOR ALL PENETRATIONS, CORE DRILLING,
<br />SEALING, WATERPROOFING, CUTTING, PATCHING, PAINTING AND RESTORATION FOR
<br />THE COMPLETE CONTRACT WORK INDICATED. ALL RESTORATION WORK PERFORMED
<br />BY THIS CONTRACTOR SHALL RESTORE EXISTING DISTURBED SURFACES TO
<br />ACCURATELY MATCH ALL SURROUNDING CONSTRUCTION USING THE SAME MATERIAL,
<br />WORKMANSHIP AND FINISH AS EXISTING SURFACES.
<br />64. ALL PENETRATIONS THROUGH OR CHOPPING OF EXISTING FLOOR SLAB FOR
<br />ELECTRICAL INSTALLATION SHALL BE COORDINATED WITH BUILDING MANAGER. ALL
<br />WORK SHALL BE PERFORMED AFTER NORMAL BUSINESS HOURS. LOCATIONS SHALL BE
<br />LAID OUT AND CONFIRMED BY ARCHITECT PRIOR TO START OF PHYSICAL WORK.
<br />65. WHENEVER EXCAVATION, CORE DRILLING OR CUTTING OF EXISTING SLABS,
<br />CONCRETE OR PAVEMENT ARE PERFORMED, THE CONTRACTOR SHALL HIRE A
<br />SPECIALIST TO PERFORM SUBSURFACE SCANS TO IDENTIFY AND FLAG UTILITIES,
<br />REBAR, ETC. SO THEY ARE NOT DAMAGED. ANY DEVIATIONS FROM THE PENETRATIONS
<br />INDICATED ON THE CONTRACT DOCUMENTS MUST BE APPROVED BY THE ENGINEER OF
<br />RECORD AND/OR OWNER.
<br />66. DISCONNECT, REMOVE, RELOCATE AND RECONNECT ANY ELECTRICAL EQUIPMENT
<br />NOT SHOWN ON THESE DRAWINGS AS PART OF THIS CONTRACT BUT INTERFERING
<br />WITH THE WORK UNDER THIS CONTRACT. THIS WORK SHALL NOT BE CONSIDERED
<br />EXTRA AND SHALL BE DONE AT NO ADDITIONAL COST TO THE OWNER.
<br />67. MAINTAIN CONTINUOUS SERVICE ON EXISTING FEEDERS SERVING THE AREAS
<br />AFFECTED DURING ALL THE PERIOD THE AREA IS UNDER CONSTRUCTION. NO
<br />OUTAGES WILL BE PERMITTED IN THESE AREAS DUE TO THE CONSTRUCTION PHASE.
<br />ALL WORK REQUIRING TEMPORARY SHUTDOWN SHALL BE PERFORMED AT NO
<br />ADDITIONAL COST TO THE OWNER. ANY REQUEST FOR SHUTDOWNS SHOULD BE
<br />BROUGHT TO THE ATTENTION OF OWNER'S REPRESENTATIVE AND BUILDING
<br />OPERATING PERSONNEL AND IT MUST BE NOTIFIED 72 (SEVENTY-TWO) HOURS IN
<br />ADVANCE. WORK SHALL NOT BE PERFORMED WITHOUT WRITTEN APPROVAL.
<br />68. ALL WORK REQUIRING ELECTRICAL SHUTDOWN WHICH WILL AFFECT OTHER FLOORS
<br />OF THE BUILDING OR EVEN AFFECT THE NORMAL CONTINUATION OF CONSTRUCTION
<br />WORK ON THESE & OTHER FLOORS, SHALL BE DONE ON OVERTIME HOURS, AND SHALL
<br />NOT DISTURB CONTINUITY OF ELECTRICAL SERVICE TO EXISTING TENANTS ON THE
<br />AFFECTED FLOORS AND SHALL BE COORDINATED WITH THE BUILDING ENGINEER.
<br />69. ALL ELECTRICAL WORK IN ADJOINING AREAS WHICH IS REQUIRED TO FUNCTION BUT IS
<br />AFFECTED BY THIS WORK SHALL BE RECONNECTED AND RESTORED TO ITS PRESENT
<br />FUNCTION AS PART OF THE ELECTRICAL SYSTEM OF THE BUILDING.
<br />70. EXISTING RISER AND/OR FEEDER CABLES BEING REUSED SHALL BE TESTED TO
<br />CONFIRM PHASE-TO-PHASE AND PHASE-TO-NEUTRAL VOLTAGES AND SHALL HAVE
<br />INSULATION TESTED USING A 1000V MEGOHMMETER. ANY CABLES FAILING SUCH TEST
<br />SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER FOR FURTHER DIRECTION.
<br />39. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING
<br />HEIGHT OF WIRING DEVICES SUCH AS RECEPTACLES, LIGHTING SWITCHES, DIMMERS,
<br />DATA/TELEPHONE OUTLETS, ETC. IN FINISHED SPACES AND/OR SURFACES. MOUNTING
<br />HEIGHTS AND SPACING SHALL BE IN COMPLIANT WITH THE APPLICABLE CODES AT ALL
<br />TIMES.
<br />40. VERIFY SWITCHES, DIMMERS, RECEPTACLES AND COVER PLATES FINISHES WITH THE
<br />ARCHITECT AND/OR OWNER REPRESENTATIVE BEFORE PURCHASING AND
<br />INSTALLATION OF SUCH DEVICES.
<br />41. WHERE MULTIPLE SWITCHES, DIMMERS AND RECEPTACLES ARE INDICATED AT THE
<br />SAME LOCATION, THEY SHALL BE GANGED TOGETHER AND MOUNTED BEHIND A
<br />COMMON FACE PLATE UNLESS POWERED FROM AN EMERGENCY POWER SOURCE.
<br />PROVIDE SEPARATE OUTLET BOXES FOR NORMAL AND EMERGENCY CIRCUITS. DERATE
<br />DIMMERS PER MANUFACTURER RECOMMENDATIONS WHEN GANGED TOGETHER.
<br />42. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER OR CIRCUIT BREAKER FOR EACH
<br />RECEPTACLE LOCATED WITHIN 6'-0" OF WATER OR LIQUIDS, HEATING CABLE, HEAT
<br />TRACING AND FOR OUTDOOR RECEPTACLES WHETHER INDICATED ON DRAWINGS OR
<br />NOT.
<br />43. MOUNTING HEIGHTS OF EQUIPMENT AND DEVICES SHALL BE COORDINATED WITH
<br />ARCHITECT. MOUNT DEVICES AS SPECIFIED ON DRAWING E.0.3. UTILIZE THE FOLLOWING
<br />EQUIPMENT MOUNTING HEIGHTS UNLESS OTHERWISE NOTED.
<br />A. PANELBOARDS AND CABINETS - 79" AFF TO TOP OF HIGHEST CIRCUIT BREAKER OR
<br />SWITCH.
<br />B. DISCONNECT SWITCHES - 79" AFF TO TOP OF HIGHEST CIRCUIT BREAKER OR
<br />SWITCH.
<br />44. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES INSTALLED OUTSIDE OR EXPOSED TO
<br />WEATHER SHALL HAVE NEMA 3R ENCLOSURES AND SHALL BE TIGHTLY GASKETED FOR
<br />A COMPLETE RAIN TIGHT INSTALLATION. ALL BUILDING EXTERIOR MOUNTED
<br />RECEPTACLES SHALL BE GFI RATED AND MOUNTED IN WEATHERPROOF ENCLOSURE.
<br />PROVIDE NEMA 4X RATED ENCLOSURES IN CORROSIVE ENVIRONMENTS OR KITCHEN
<br />AREAS.
<br />45. NO PIPING, DUCTS OR OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION
<br />SHALL BE INSTALLED WITHIN THE DEDICATED SPACE ABOVE SWITCHBOARDS,
<br />PANELBOARDS, DISTRIBUTION BOARDS, AND MOTOR CONTROL CENTERS TO A HEIGHT
<br />OF 6-FEET ABOVE THE EQUIPMENT OR THE STRUCTURAL CEILING WHICHEVER IS
<br />LOWER. THE AREA ABOVE THE DEDICATED SPACE SHALL NOT BE PERMITTED TO
<br />CONTAIN FOREIGN SYSTEMS UNLESS ACCEPTABLE PER CODE, REVIEWED BY THE
<br />ENGINEER, AND PROVIDED WITH SUITABLE PANS AND LEAK DETECTION.
<br />46. FOR ALL RECESSED PANELS A TROUGH SHALL BE PROVIDED IN THE NEAREST
<br />ACCESSIBLE CEILING WITH TWO (2) SPARE 2" CONDUITS AND TWO (2) SPARE 1"
<br />CONDUITS UNLESS OTHERWISE NOTED TO BE INTERCONNECTED BETWEEN THE
<br />TROUGH AND THE RECESSED PANEL FOR FUTURE USE.
<br />47. PROVIDE AND/OR REVISE THE PANEL DIRECTORY OF EACH AND EVERY NEW AND/OR
<br />EXISTING PANELBOARD AFFECTED BY THIS ELECTRICAL WORK.
<br />48. PROVIDE BLANK COVERS PLATE OVER ALL UNUSED OPENINGS IN NEW AND/OR
<br />EXISTING PANELBOARDS.
<br />49. PROVIDE UNFUSED DISCONNECT SWITCHES FOR ALL MECHANICAL EQUIPMENT UNLESS
<br />OTHERWISE NOTED ON CONSTRUCTION DOCUMENTS.
<br />50. THE MINIMUM RATING OF DISCONNECT SWITCHES SHALL BE EQUAL TO OR GREATER
<br />THAN THE RATING OF THE PROTECTIVE DEVICES ON THE SUPPLY SIDE OF THE
<br />DISCONNECT SWITCH. MINIMUM DISCONNECT SWITCH SIZE IS 30 AMPERES.
<br />51. ALL EQUIPMENT SHALL HAVE COPPER CURRENT CARRYING PARTS. ALUMINUM SHALL
<br />NOT BE PERMITTED.
<br />52. ARCHITECTURAL FEATURES AS WELL AS OTHER TRADES EQUIPMENT SHOWN ON
<br />ELECTRICAL DRAWINGS ARE FOR BACKGROUND INFORMATION ONLY. COORDINATE
<br />WITH OTHER TRADES TO DETERMINE THE EXACT LOCATION OF FANS, A/C UNITS,
<br />MOTORS, PUMPS, EQUIPMENT TERMINAL BOXES, AND OTHER EQUIPMENT TO BE
<br />INSTALLED BY OTHER TRADES BEFORE CONDUIT WORK IS STARTED.
<br />53. FOR EXACT LOCATION OF LIGHT FIXTURES, LIGHTING FIXTURE SCHEDULE (UNLESS
<br />SHOWN ON THESE DRAWINGS) AND LIGHTING SYMBOLS REFER TO ARCHITECTURAL
<br />AND/OR LIGHTING CONSULTANT DRAWINGS. INFORMATION SHOWN IN ELECTRICAL
<br />DRAWINGS IS FOR REFERENCE ONLY. FINAL LIGHTING APPROVAL BY ARCHITECT.
<br />54. MOUNTING ACCESSORIES FOR RECESSED LIGHTING FIXTURES SHALL BE
<br />APPROPRIATE TO MEET THE REQUIREMENTS OF THE CEILING CONSTRUCTION. REFER
<br />TO ARCHITECTURAL DRAWINGS FOR CEILING TYPE SCHEDULE.
<br />55. PENDANT MOUNTED FIXTURES IN AREAS WITH NO HUNG CEILING SHOULD BE
<br />INSTALLED AFTER DUCTWORK AND PIPING HAVE BEEN INSTALLED. COORDINATE
<br />MOUNTING HEIGHT AND LOCATION OF LIGHTING FIXTURES TO CLEAR MECHANICAL,
<br />ELECTRICAL, FIRE PROTECTION AND PLUMBING EQUIPMENT AND PIPING.
<br />56. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ELECTRICAL WORK NECESSARY TO
<br />INSTALL ELECTRIFIED LANDSCAPE FURNITURE WORKSTATIONS, INCLUDING, BUT NOT
<br />LIMITED TO, INSTALLATION OF THE FOLLOWING COMPONENTS FURNISHED BY OTHERS:
<br />POWER ENTRY IN-FEEDS, BASE RACEWAYS, HARNESSES, INTERPANEL CONNECTORS,
<br />RECEPTACLES, TELECOM DEVICES, TASK LIGHTING, ETC.
<br />57. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NECESSARY LABOR AND MATERIALS
<br />AS REQUIRED TO MAINTAIN THE FIRE RATINGS OF WALLS WHERE ELECTRICAL
<br />DEVICES/EQUIPMENT ARE TO BE INSTALLED.
<br />58. INVESTIGATE EACH SPACE THROUGH WHICH EQUIPMENT MUST BE MOVED. WHERE
<br />NECESSARY, EQUIPMENT SHALL BE SHIPPED FROM MANUFACTURER IN SECTIONS OF
<br />SIZE SUITABLE FOR MOVING THROUGH AVAILABLE RESTRICTIVE SPACES. ASCERTAIN
<br />FROM BUILDING OWNER AND TENANT AT WHAT TIMES OF DAY EQUIPMENT MAY BE
<br />MOVED THROUGH THE AREAS.
<br />59. CONTRACTOR TO BE RESPONSIBLE FOR THE PROPER INSTALLATION, PRE-SETTING,
<br />WIRING, PLACEMENT AND ADJUSTMENT OF ALL SENSORS INCLUDING BUT NOT LIMITED
<br />TO OCCUPANCY SENSORS, VACANCY SENSORS, DAYLIGHT SENSORS, ETC. AS PER THE
<br />MANUFACTURER'S SPECIFICATIONS, MANUFACTURER WRITTEN INSTRUCTIONS AND
<br />APPROVED SUBMITTALS. CONTRACTOR WILL ALSO BE RESPONSIBLE TO ASSIST THE
<br />MANUFACTURER'S REPRESENTATIVE DURING THE SYSTEM COMMISSIONING PROCESS
<br />AND WILL BE REQUIRED TO RELOCATE AND RE-ADJUST SENSORS, AT NO ADDITIONAL
<br />COST TO THE CLIENT, UNTIL THE LIGHTING CONTROLS SYSTEM IS FUNCTIONING AS
<br />PER THE SPECIFIED CONTROL INTENT AND CLIENT SATISFACTION.
<br />19. ALL CONDUIT RUNS SHALL BE CONCEALED WITHIN WALLS OR CEILING. EXPOSED
<br />CONDUITS AND BOXES, WHEN REQUIRED, SHALL BE PAINTED. PAINTING SHALL
<br />CONSIST OF A PRIME COAT AND A FINISHED COAT, COLOR AS SELECTED BY
<br />ARCHITECT OR TO MATCH SURROUNDING SURFACES. FACTORY PAINTING WILL BE
<br />ACCEPTED AS A PRIME COAT.
<br />20. MINIMUM SIZE OF CONDUITS SHALL BE 3/4", UNLESS OTHERWISE NOTED.
<br />21. INSTALL PULL WIRES IN EMPTY RACEWAYS. USE POLYPROPYLENE OR MONOFILAMENT
<br />PLASTIC LINE WITH NOT LESS THAN 200-LB (90-KG) TENSILE STRENGTH. LEAVE AT
<br />LEAST 12 INCHES (300 MM) OF SLACK AT EACH END OF PULL WIRE
<br />22. PROVIDE PIPE SLEEVES WHERE CONDUITS ARE ROUTED THROUGH FOUNDATION
<br />WALLS, SLABS AND FIRE RATED PARTITIONS. PIPE SLEEVES SHALL BE GROUTED.
<br />SEALANT SHALL BE APPLIED AROUND THE CONDUIT IN THE SLEEVE IN ORDER TO
<br />PREVENT INGRESS OF MOISTURE. WALL AND SLAB PENETRATIONS SHALL BE
<br />COMPLETELY WATERPROOFED AND FIREPROOFED WITH UL APPROVED MATERIALS.
<br />23. ALL OPENINGS BETWEEN FLOORS, THROUGH RATED FIRE AND SMOKE WALLS, OR
<br />CREATED BY THE CONTRACTOR FOR CABLE OR CONDUIT PASS-THROUGH SHALL BE
<br />SEALED WITH A UL LISTED FIRE-STOPPING MATERIAL. FIRE-STOPPING MATERIAL AND
<br />ITS APPLICATION SHALL BE ACCOMPLISHED IN SUCH A MANNER THAT IS ACCEPTABLE
<br />TO THE LOCAL FIRE AND BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS
<br />WORK. ANY OPENINGS CREATED BY OR FOR THE CONTRACTOR AND LEFT UNUSED
<br />SHALL ALSO BE SEALED AS PART OF THIS WORK. REFER TO ARCHITECTURAL
<br />DRAWINGS FOR FIRE RATING OF WALLS AND SLABS.
<br />24. IN UNFINISHED SPACES OF THE BUILDING SUCH AS FAN ROOMS, PIPE SPACES, ETC.,
<br />LOCATIONS OF CONDUIT AND OUTLETS ARE APPROXIMATE AND SHALL CLEAR PIPING
<br />AND ALL OTHER CONSTRUCTION. ALL OUTLETS MUST BE UNOBSTRUCTED AND
<br />EXTENDED AS DIRECTED TO CLEAR ANY INTERFERENCE WITH FIXTURES, PIPING
<br />EQUIPMENT, ETC.
<br />25. SUPPORT ALL ELECTRICAL EQUIPMENT AND CONDUIT FROM BUILDING STRUCTURE
<br />AND/OR FRAMING IN AN APPROVED MANNER. WHERE OVERHEAD CONSTRUCTION DOES
<br />NOT PERMIT FASTENING OF SUPPORTS FOR EQUIPMENT, FURNISH ADDITIONAL
<br />FRAMING. ALL ELECTRICAL EQUIPMENT AND RACEWAY SHALL BE SUSPENDED FROM
<br />SUPPLEMENTAL SLOTTED CHANNEL FRAME. ALL SUCH MOUNTS, DEVICES, FASTENERS
<br />SHALL BE OF SUFFICIENT THICKNESS TO CARRY THE LOAD SUSPENDED. CONTRACTOR
<br />SHALL BE RESPONSIBLE FOR PROVIDING ANY ADDITIONAL SUPPLEMENTAL STEEL
<br />REQUIRED TO SUPPORT THE EQUIPMENT OR DEVICES.
<br />26. PROVIDE OUTLET BOXES AND ENCLOSURES APPROPRIATE FOR THE PURPOSE AND
<br />ENVIRONMENT AT ALL LOCATIONS WHERE THE DRAWINGS REQUIRE THE INSTALLATION
<br />OF ELECTRICAL DEVICES OR ELECTRICAL EQUIPMENT.
<br />27. ALL EXPOSED NONCURRENT-CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT
<br />AND RACEWAYS SHALL BE GROUNDED. FOR FEEDERS AND/OR BRANCH CIRCUITS
<br />WHERE GROUNDING CONDUCTOR IS NOT PROVIDED, METAL RACEWAYS AND METAL
<br />ENCLOSURES FOR CONDUCTORS SHALL BE TIGHTLY JOINED TO CREATE A
<br />CONTINUOUS ELECTRIC CIRCUIT AND SO ASSURE A PROPERLY GROUNDED SYSTEM.
<br />FITTINGS FOR JOINTS AND TERMINATIONS SHALL BE LISTED FOR GROUNDING
<br />INSTALLATION. PROVIDE BONDING JUMPERS WITH APPROVED FITTINGS OF SIZE
<br />REQUIRED FOR EQUIPMENT GROUNDING. THE CONTRACTOR SHALL ENSURE
<br />CONTINUITY OF THE GROUNDING CIRCUIT FROM THE SUPPLYING PANELBOARD
<br />GROUNDING BUS TO THE LOAD GROUND TERMINAL.
<br />28. UNLESS OTHERWISE NOTED, CONDUCTORS FOR POWER AND LIGHTING CIRCUITS
<br />SHALL BE OF TYPE THHN/THWN AND MINIMUM SIZE SHALL BE #12 AWG. CONDUCTORS
<br />#10 AWG AND SMALLER SHALL BE SOLID COPPER; #8 AWG AND LARGER SHALL BE
<br />COPPER, STRANDED.
<br />29. BRANCH CIRCUIT CONDUCTORS SHALL BE INCREASED IN SIZE TO COMPENSATE FOR
<br />VOLTAGE DROP AS FOLLOWS:
<br />A. FOR CIRCUITS RATED AT 120V, 20A THAT RUN OVER 100'-0", USE #10 AWG WIRE SIZE.
<br />B. FOR CIRCUITS RATED AT 277V, 20A THAT RUN OVER 200'-0", USE #10 AWG WIRE SIZE.
<br />30. LOW VOLTAGE WIRING SHALL NOT BE PERMITTED IN THE SAME RACEWAY AS POWER
<br />WIRING.
<br />31. ALL GROUND WIRES SHALL BE INSTALLED IN CONDUIT. FERROUS METAL RACEWAYS
<br />MUST BE BONDED TO THE CONTAINED GROUNDING ELECTRODE CONDUCTOR.
<br />32. FOR CONCRETE BUILDINGS THAT DO NOT HAVE A GROUNDING RISER OR A
<br />TELECOMMUNICATION BONDING BACKBONE, CONTRACTOR SHALL EXTEND THE
<br />GROUNDING CONDUCTOR FOR SEPARATELY DERIVED SYSTEMS AND BONDING
<br />CONDUCTOR FOR TELECOMMUNICATION EQUIPMENT TO THE MAIN BUILDING
<br />GROUNDING BUS BAR.
<br />33. ALL BRANCH CIRCUITS SHALL BE PROVIDED WITH DEDICATED NEUTRALS. IF
<br />CONTRACTOR ELECTS TO SHARE NEUTRALS, IT IS HIS RESPONSIBILITY TO PROVIDE A
<br />MEANS TO DISCONNECT ALL BRANCH CIRCUITS SIMULTANEOUSLY (MULTIPLE
<br />BREAKERS). FOR EXISTING PANELBOARDS THE CONTRACTOR SHALL UPGRADE,
<br />PROVIDE NEUTRAL BAR TERMINATION EXTENSION KITS OR REPLACE NEUTRAL
<br />TERMINATION BARS AS REQUIRED FOR THE DEDICATED NEUTRALS.
<br />34. PROVIDE DEDICATED NEUTRALS FOR CIRCUITS FED FROM SINGLE-POLE
<br />OVERCURRENT PROTECTIVE DEVICES, GROUND FAULT PROTECTED CIRCUITS WHERE
<br />A GFCI OR GFPE BREAKER IS USED IN A PANELBOARD, CIRCUITS FEEDING DIMMER
<br />CONTROLLED LOADS, AND CIRCUITS FEEDING ELECTRONIC EQUIPMENT WHICH
<br />PRODUCES A HIGH LEVEL OF HARMONIC DISTORTION INCLUDING, BUT NOT LIMITED TO,
<br />COMPUTERS, PRINTERS, PLOTTERS, COPY MACHINES, AND FAX MACHINES.
<br />35. ELECTRICAL DRAWINGS INDICATE CIRCUIT NUMBERS (#) FOR RECEPTACLES, LIGHTING
<br />FIXTURES AND OTHER EQUIPMENT FEEDS. UNLESS OTHERWISE NOTED PROVIDE 2#12,
<br />1#12G IN 3/4" CONDUIT TO 15A OR 20A CIRCUIT BREAKERS IN PANELS INDICATED.
<br />CIRCUIT NUMBERS (#) NOTED ON PLANS ARE INTENDED AS A GUIDE. FINAL NUMBERING
<br />SYSTEM TO BE NOTED ON AS-BUILT DRAWINGS AND ON TYPED PANELBOARD
<br />DIRECTORY CARDS.
<br />36. FURNISH AND INSTALL WIRING FOR EQUIPMENT FURNISHED BY OTHERS, AS SHOWN
<br />ON ARCHITECTURAL, HVAC, PLUMBING, IT AND/OR ELECTRICAL DRAWINGS.
<br />COORDINATE WITH OTHER TRADES FOR DETAILS OF INSTALLATION AND WIRING
<br />REQUIREMENTS. THE TERM "WIRING" AS USED HEREIN SHALL INCLUDE FURNISHING
<br />AND INSTALLING CONDUIT, WIRES, JUNCTION/OUTLET BOXES, DISCONNECTS,
<br />OVERCURRENT PROTECTION DEVICES AND FINAL CONNECTIONS. COORDINATE FINAL
<br />CONDUCTOR SIZES, QUANTITIES, VOLTAGE REQUIREMENTS, AND OVERCURRENT
<br />DEVICE AND OUTLET RATINGS WITH ACTUAL EQUIPMENT TO BE FURNISHED TO THE
<br />SITE PRIOR TO FINALIZING WIRING INSTALLATION. MINOR ADJUSTMENTS TO WIRING
<br />REQUIREMENTS NECESSARY TO ACCOMMODATE ACTUAL FURNISHED EQUIPMENT
<br />SHALL BE PROVIDED AT NO ADDITIONAL COST TO OWNER.
<br />37. PROVIDE ALL REQUIRED ELECTRICAL FINAL CONNECTIONS. FURNISH AND INSTALL ALL
<br />COPPER MATERIALS INCLUDING BUT NOT LIMITED TO LUGS, COPPER BUS
<br />DETAILS/LUGS KITS, BUS BAR EXTENSIONS, MULTI-TAPS, ETC AS REQUIRED TO ACCEPT
<br />INCOMING AND OUTGOING CABLES TO COMPLETE CONTRACT WORK. ALSO PROVIDE
<br />LABOR AND MATERIAL AS REQUIRED TO MODIFY EXISTING OR NEW EQUIPMENT
<br />INCLUDING ENCLOSURE MODIFICATIONS.
<br />38. VERIFY LOCATIONS OF ALL ELECTRICAL EQUIPMENT WITH ARCHITECTURAL DRAWINGS
<br />OR INTERIOR DETAILS. WHEN LOCATING BOXES OR OUTLETS, ALLOW FOR OVERHEAD
<br />PIPES, DUCTS, MECHANICAL EQUIPMENT, VARIATIONS IN FIREPROOFING AND
<br />PLASTERING, WINDOW AND DOOR TRIM, PANELING, HUNG CEILING, ETC., AND
<br />CORRECT ANY INACCURACY RESULTING FROM FAILURE TO DO SO WITHOUT EXPENSE
<br />TO OWNER.
<br />1. ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED IN STRICT ACCORDANCE
<br />WITH THE REQUIREMENTS OF THE FOLLOWING CODES AND STANDARDS:
<br />2. PROVIDE ALL LABOR, MATERIALS, SUPERVISION, TOOLS, SCAFFOLDING, MACHINERY,
<br />EQUIPMENT, APPLIANCES, AND SERVICES INCLUDING TRANSPORTATION, RIGGING,
<br />STORAGE UTILITIES, ETC. AS REQUIRED TO COMPLETE THE WORK UNDER THIS
<br />CONTRACT. ALL SYSTEMS AND EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT
<br />AND ALL MATERIAL, EQUIPMENT AND LABOR SHALL BE FURNISHED, INSTALLED, TESTED
<br />AND COMMISSIONED FOR A FULLY OPERATIONAL SYSTEM.
<br />3. PROVIDE LINE VOLTAGE POWER WIRING, CONDUIT AND OVERCURRENT PROTECTION
<br />REQUIRED FOR HVAC, MECHANICAL, PLUMBING AND FIRE PROTECTION EQUIPMENT
<br />AND CONTROLS REGARDLESS OF WHETHER SPECIFICALLY INDICATED IN ELECTRICAL
<br />DOCUMENTS. REFER TO OTHER TRADE DOCUMENTS FOR ALL EQUIPMENT AND
<br />CONTROL NEEDS.
<br />4. PROVIDE LABOR AND MATERIALS REQUIRED FOR THE INSTALLATION AND
<br />MAINTENANCE OF TEMPORARY LIGHTING AND TEMPORARY POWER FOR TOOLS,
<br />HEATING AND/OR COOLING OR OTHER REASONS. CONTRACTOR TO DISCUSS THE
<br />TEMPORARY LIGHTING/POWER REQUIREMENTS WITH THE GENERAL CONTRACTOR
<br />PRIOR TO BID AND INCLUDE THE COST OF FILING, PERMITS, APPROVALS, RENTALS AND
<br />EQUIPMENT INCLUDING BUT NOT LIMITED TO DISTRIBUTION SWITCHBOARDS,
<br />PANELBOARDS, METERS, FEEDERS, BRANCH WIRING, LIGHTING FIXTURES, WIRING
<br />DEVICES, GENERATORS (INCLUDING FUEL), ETC.
<br />5. ALL ELECTRICAL EQUIPMENT SHALL BE THE LATEST OF THE CURRENT YEAR IN DESIGN
<br />AND MATERIAL, AND SHALL COMPLY WITH ALL APPLICABLE REQUIREMENTS OF LAWS,
<br />CODES, ORDINANCES, LEGISLATION, STANDARDS, ETC., OF ALL FEDERAL, STATE, AND
<br />LOCAL AUTHORITIES, WHETHER INDICATED ON THE CONTRACT DOCUMENTS OR NOT.
<br />6. CONTRACTOR TO BE RESPONSIBLE FOR REVIEWING THE FULL SET OF BID DOCUMENTS
<br />TO BE AWARE OF THE TOTAL SCOPE PRIOR TO SUBMITTING BID. ALL WORK SHOWN ON
<br />THE DRAWINGS NOT SPECIFICALLY CALLED OUT AS EXISTING SHALL BE CONSIDERED
<br />WORK TO BE PERFORMED UNDER THIS CONTRACT.
<br />7. BIDDERS, BEFORE SUBMITTING A PROPOSAL, SHALL VISIT AND CAREFULLY EXAMINE
<br />THE SITE TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND WITH THE
<br />DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THIS WORK. SUBMISSION OF A
<br />PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN
<br />MADE. LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR, EQUIPMENT OR
<br />MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED. NO ALLOWANCE
<br />WILL SUBSEQUENTLY BE MADE TO THE CONTRACTOR BY REASON OF ANY ERROR DUE
<br />TO THE CONTRACTOR'S NEGLECT TO COMPLY WITH THIS REQUIREMENT. REPORT ANY
<br />DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS TO THE ENGINEER.
<br />8. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED
<br />CERTIFICATES OF INSURANCE WITH THE BUILDING OWNER, FILE ALL NECESSARY
<br />FORMS WITH THE BUILDING DEPARTMENT, FIRE DEPARTMENT AND OTHER
<br />GOVERNMENTAL AGENCIES, OBTAIN ALL REQUIRED PERMITS, TEST/INSPECTION
<br />REPORTS, CERTIFICATIONS FOR T.C.O. AND C.O. AND PAY ALL FEES REQUIRED.
<br />9. ALL NOTATIONS OF "SCALE" ARE INTENDED AS APPROXIMATIONS. THE CONTRACTOR
<br />SHALL BE RESPONSIBLE TO ASCERTAIN THE EXACT DIMENSIONS IN FIELD.
<br />10. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC, SIZES AND LOCATION OF EQUIPMENT
<br />AND WIRING ARE SHOWN TO SCALE WHERE POSSIBLE, BUT MAY BE DISTORTED FOR
<br />CLARITY ON THE DRAWINGS. IT IS THE CONTRACTORS RESPONSIBILITY TO
<br />COORDINATE WITH OTHER TRADES AND INSTALL EQUIPMENT AS PER FIELD
<br />CONDITIONS.
<br />11. ELECTRICAL CONTRACTOR SHALL TAKE DELIVERY AND RESPONSIBILITY FOR ALL
<br />EQUIPMENT PRE-PURCHASED BY THE OWNER FOR THIS PROJECT. WORK SHALL
<br />INCLUDE RECEIVING EQUIPMENT AT STREETSIDE MOVING IT TO INTERIM ONSITE
<br />SECURE STORAGE LOCATION, PROTECTING EQUIPMENT FROM DAMAGE, MOVING THE
<br />EQUIPMENT FROM STORAGE TO ITS FINAL POSITION, SETTING IN PLACE, AND
<br />COMPLETION OF ALL INSTALLATION, TESTING AND COMMISSIONING PROCEDURES
<br />REQUIRED FOR APPLICABLE EQUIPMENT.
<br />12. UPON COMPLETION OF ALL ELECTRICAL WORK, ELECTRICAL CONTRACTOR SHALL
<br />ADJUST AND TEST ALL CIRCUITS, CIRCUIT PROTECTION DEVICES (CIRCUIT BREAKERS,
<br />GROUND FAULT RELAYS, ETC.), WIRING DEVICES, ENERGY CONTROL DEVICES,
<br />LIGHTING FIXTURES, MOTORS AND ANY OTHER ELECTRICAL ITEMS INSTALLED. ANY
<br />DEFECTIVE ITEMS SHALL BE IMMEDIATELY REPAIRED OR REPLACED WITH NEW
<br />EQUIPMENT OR MATERIALS AND THAT PORTION OF THE SYSTEM SHALL BE RE-TESTED.
<br />ALL SUCH REMEDIAL WORK SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE
<br />OWNER.
<br />13. UPON COMPLETION OF WORK, ELECTRICAL CONTRACTOR SHALL BALANCE ALL
<br />PANELBOARDS AFFECTED TO WITHIN 10% DEVIATION BETWEEN PHASES.
<br />14. REMOVE ALL DEBRIS RESULTING FROM REMOVAL AND/OR INSTALLATION OF
<br />ELECTRICAL WORK FROM THE PREMISES. REMOVAL OF DEBRIS SHALL BE
<br />COORDINATED WITH BUILDING MANAGEMENT. DISPOSAL WORK SHALL BE IN
<br />COMPLIANCE WITH THE REQUIREMENTS OF THE BUILDING CODE AND WITH ALL STATE
<br />AND FEDERAL REGULATIONS
<br />15. UNLESS OTHERWISE NOTED, ELECTRICAL EQUIPMENT INCLUDING BUT NOT LIMITED TO
<br />PULL BOXES, JUNCTION BOXES, WIRING DEVICES, PANELBOARDS, LOW VOLTAGE
<br />SYSTEMS DEVICES, ETC WHERE INDICATED ON DRAWINGS, SHALL BE CONSIDERED
<br />SHOWN AT THEIR APPROXIMATE LOCATION. THE CONTRACTOR SHALL LOCATE THESE
<br />ITEMS AS FIELD CONDITIONS DICTATE AND AS APPROVED BY THE ARCHITECT AND/OR
<br />ENGINEER.
<br />16. ALL CONDUIT RUNS, WHEN SHOWN ON THE DRAWINGS, ARE SHOWN
<br />DIAGRAMMATICALLY TO OUTLINE THE GENERAL ROUTING OF MAJOR FEEDERS AND
<br />BRANCH WIRING. IT IS NOT WITHIN THE SCOPE OF THESE DRAWINGS TO SHOW ALL
<br />NECESSARY BENDS, OFFSETS, PULL BOXES, CABLE SUPPORT BOXES, JUNCTION
<br />BOXES AND OBSTRUCTIONS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
<br />TO INSTALL HIS WORK TO CONFORM TO THE REQUIREMENTS OF THE ELECTRICAL
<br />CODE, FIELD CONDITIONS, AND TO PRESERVE HEADROOM.
<br />17. ADDITIONAL PULL BOXES, JUNCTION BOXES AND WIRE TROUGHS NOT SHOWN ON
<br />DRAWINGS SHALL BE PROVIDED WHERE REQUIRED BY APPLICABLE CODE
<br />REQUIREMENTS OR WHERE CALLED FOR BY FIELD CONDITIONS. PULL AND JUNCTION
<br />BOXES SHALL BE SURFACE TYPE IN UNFINISHED SPACES AND FLUSH TYPE IN FINISHED
<br />SPACES. PROVIDE COVERS FOR ALL JUNCTION BOXES, PULL BOXES AND WIRE
<br />TROUGHS. COVERS SHALL BE ACCESSIBLE.
<br />18. CONDUIT RUNS SHALL CLEAR ALL ARCHITECTURAL FEATURES (DOORS, WINDOWS,
<br />ETC.) AND STRUCTURAL MEMBERS. CONDUIT INSTALLATION SHALL ALSO BE MADE TO
<br />AVOID INTERFERENCE WITH PIPES, DUCTS, OR OTHER EQUIPMENT CORRESPONDING
<br />TO OTHER TRADES, INCLUDING BUT NOT LIMITED TO MECHANICAL, PLUMBING AND FIRE
<br />PROTECTION. SHALL ANY OF THIS ELEMENTS PREVENT THE INSTALLATION OF
<br />RACEWAY AS DELINEATED ON THE CONTRACT DOCUMENTS, DEVIATION MUST BE
<br />APPROVED BY THE ENGINEER PRIOR TO INSTALLATION. ANY VARIATION DUE TO FIELD
<br />CONDITIONS SHALL NOT REPRESENT AN ADDITIONAL COST TO OWNER.
<br />(ALL DIMENSIONS TO CENTERLINE OF BOX U.O.N.):
<br />A. 2022 CALIFORNIA ELECTRICAL CODE
<br />B. 2022 CALIFORNIA BUILDING CODE
<br />C. 2022 CALIFORNIA FIRE ALARM CODE
<br />D. 2022 BUILDING ENERGY EFFICIENCY STANDARDS (TITLE 24)
<br />E. TENANT DESIGN AND CONSTRUCTION HANDBOOK.
<br />F. BUILDING MANAGEMENT RULES AND REGULATIONS.
<br />G. OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)
<br />H. AMERICAN DISABILITIES ACT (ADA)
<br />I. UNDERWRITERS LABORATORIES, INC. (UL)
<br />J. ALL LOCAL JURISDICTION DIRECTIVES AND REQUIREMENTS.
<br />Mechanical and Electrical Engineers
<br />Lilker Associates
<br />1001 Avenue of the Americas
<br />New York, NY 10018
<br />tel 212.695.1000
<br />fax 212.695.1299
<br />www.lilker.com
<br />Kenneth A. Gruskin AIA
<br />No. Date Description
<br />Consultant:
<br />Checked By:
<br />Drawn By:
<br />Job Address:
<br />Drawing Title:
<br />Revision Issue:
<br />Professional Seal:
<br />Drawing Number:
<br />2024 Gruskin Architecture + Design, P.C.c
<br />This document and the ideas and designs incorporated
<br />herein, as an instrument of professional service, is the
<br />property of GRUSKIN ARCHITECTURE + DESIGN, P.C.,
<br />and is not to be used in whole or in part for any other
<br />project without the written authorization of GRUSKIN
<br />ARCHITECTURE + DESIGN, P.C.
<br />North
<br />Arrow:
<br />Job Name and Number:
<br />Date Issued For
<br />All Rights Reserved
<br />Client:
<br />Landlord:
<br />Permit:
<br />Bid:
<br />Construction:
<br />0006261
<br />AR91629
<br />5421
<br />9613
<br />39209
<br />10635
<br />2537
<br />11016
<br />5734
<br />ARC 2596
<br />4674
<br />2666
<br />AI 09999
<br />2796
<br />0401 011223
<br />2572
<br />17680
<br />RA-015432-B
<br />025528-1 NY
<br />TX
<br />VA
<br />VT
<br />MA
<br />MT
<br />RI
<br />PA
<br />NY
<br />NJ
<br />NH
<br />MD
<br />LA
<br />ME
<br />KS
<br />FL
<br />DE
<br />CT
<br />AZ
<br />AL
<br />C-1967WY
<br />RA011075GA
<br />AR10400066IN
<br />C-29898CA
<br />NM 004168
<br />ARC-400347CO
<br />HI AR 11489
<br />PR 19965
<br />OR 4899
<br />SC 6834
<br />NC 9961
<br />13761OH
<br />05713IA
<br />WV 3727
<br />IL 001-019152
<br />UT 5881358-0301
<br />ID AR-984459
<br />1301052379MI
<br />ARC100723DC
<br />WI 9900-005MN44326
<br />A-3547NE
<br />3811AR
<br />5967KY 101374TN
<br />MS 3860
<br />1666ND
<br />A-2005029740MO
<br />a4895OK
<br />NV 5521
<br />WA 10344
<br />13167AK
<br />SD 11532
<br />C:
<br />\
<br />R
<br />e
<br />v
<br />i
<br />t
<br />
<br />L
<br />o
<br />c
<br />a
<br />l
<br />
<br />F
<br />i
<br />l
<br />e
<br />s
<br />\
<br />2
<br />4
<br />0
<br />0
<br />1
<br />3
<br />0
<br />8
<br />_
<br />V
<br />E
<br />R
<br />I
<br />Z
<br />O
<br />N
<br />_
<br />S
<br />a
<br />n
<br />t
<br />a
<br />
<br />A
<br />n
<br />a
<br />_
<br />C
<br />A
<br />_
<br />EL
<br />E
<br />C
<br />T
<br />R
<br />I
<br />C
<br />A
<br />L
<br />_
<br />v
<br />2
<br />3
<br />_
<br />D
<br />B
<br />e
<br />l
<br />l
<br />B
<br />R
<br />N
<br />E
<br />Z
<br />.
<br />r
<br />v
<br />t
<br />2023-0069
<br />Proposed
<br />Store Design
<br />for: VERIZON
<br />Metro Pointe
<br />3500 South Bristol Street
<br />Suite 100
<br />Santa Ana, CA 92704
<br />3/15/24
<br />3/15/24
<br />ELECTRICAL GENERAL
<br />NOTES
<br />E.0.0
<br />DB
<br />MH
<br />45 OF 81
<br />ELECTRICAL DRAWING LIST
<br />E.0.0 ELECTRICAL GENERAL NOTES
<br />E.0.1 ELECTRICAL SYMBOLS, LEGENDS AND
<br />ABBREVIATIONS
<br />E.0.2 ELECTRICAL SPECIFICATIONS (1 OF 2)
<br />E.0.3 ELECTRICAL SPECIFICATIONS (2 OF 2)
<br />E.1.0 POWER FLOOR PLAN
<br />E.1.1 POWER LOCATION PLAN
<br />E.1.2 LIGHTING FLOOR PLAN
<br />E.1.3 LIGHT FIXTURE DETAILS
<br />E.1.4 LIGHTING SCHEDULE AND CONTROLS
<br />E.2.0 PARTIAL RISER DIAGRAM & PANEL SCHEDULES
<br />E.2.1 ELECTRICAL DETAILS - FLOOR BOXES
<br />E.2.2 LIGHTNG CONTROL DIAGRAMS
<br />E.2.3 TELCO ELEVATIONS AND DETAILS
<br />E.3.0 TITLE 24 ENERGY COMPLIANCE FORM
<br />E.3.1 TITLE 24 ENERGY COMPLIANCE FORM
<br />E.3.2 TITLE 24 ENERGY COMPLIANCE FORM
<br />E.3.3 TITLE 24 ENERGY COMPLIANCE FORM
<br />E.3.4 TITLE 24 ENERGY COMPLIANCE FORM