OS <br />OS OS <br />OS <br />SO <br />OS <br />OS <br />NOTE: <br />LABEL SWITCHES ACCORDING TO MATRIX <br />BELOW: <br />A. RETAIL <br />B. PENDANTS <br />C. DUAL HEADS <br />D. TRACK HEADS <br />E. POS <br />F.OVERRIDE <br />A B <br />℄ <br />44 <br />" <br /> <br />A <br />F <br />F <br />E.C. SHALL PROVIDE ALL SWITCHES SHOWN IN <br />THE SWITCH BANK. PROVIDE LEVITON SLIDING <br />DIMMERS WHERE INDICATED. MOMENTARY <br />SWITCH SHALL BE LEVITON 56080-2W OR EQUAL <br />WITH SPRING RETURN TO OPEN CONFIGURATION. <br />E.C. TO RUN LOW VOLTAGE CABLE FROM THE <br />MOMENTARY SWITCH TO THE EMS CONTROLLER. <br />ALL OTHER SWITCHES ARE MANUAL OFF. <br />MOMENTARY <br />SWITCH <br />C D <br />TLVLVLVLV <br />MOMENTARY SWITCH IS NOT REQUIRED WHEN <br />THE FOLLOWING SEQUENECE IS OPERATIONAL: <br />1. WHEN SECURITY ALARM IS ARMED, <br />CONTACTOR C2 IS DISENGAGED. <br />2. WHEN SECURITY ALARM IS DISARMED, <br />CONTACTOR C2 IS ENGAGED. <br />FE <br />LV <br />GENERAL LIGHTING NOTES <br />1. SEE REFLECTED CEILING PLAN FOR ALL LIGHT FIXTURE MOUNTING HEIGHTS. <br />2. ALL FIXTURES TO BE INSTALLED PER CODE AND ALL OTHER RELEVANT ARTICLES. LAY-IN LIGHT FIXTURES SHALL <br />BE INDEPENDENTLY SUPPORTED FROM THE CEILING GRID. FIXTURE SUPPORT BY No. 12 GAUGE HANGERS <br />ATTACHED TO GRID MEMBERS WITHIN THREE (3) INCHES OF EACH CORNER OF EACH FIXTURE. <br />3. LIGHT VENTILATION AND SANITATION SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE AND OTHER <br />APPLICABLE CODES GOVERNING THE MUNICIPALITY HAVING JURISDICTION. <br />4. BUILDING SHALL OBTAIN STANDARD AVERAGE LIGHTING LEVELS THROUGHOUT AS REQUIRED BY CODE. <br />5. QUANTITY OF HEADS ON TRACK LIGHTS SHALL BE AS SHOWN ON DRAWINGS, UNLESS OTHERWISE DETERMINED <br />BY THE ARCHITECT AND VERIZON WIRELESS' PROJECT MANAGER. <br />6. VERIZON WIRELESS SHALL CONTACT VERIZON LIGHT FIXTURE VENDOR TO ORDER ALL LIGHT FIXTURES AND <br />OCCUPANCY SENSORS (REFER TO CONTACT SCHEDULE ON TITLE SHEET). GC SHALL COORDINATE WITH VERIZON <br />WIRELESS PROJECT MANAGER. <br />7. LIGHTING SYSTEMS AND CONTROLS WILL BE COMMISSIONED PER THE REQUIREMENTS OF THE COMMISSIONING <br />SECTION OF THE LEED PROTOTYPE GREEN SPECIFICATIONS. <br />8. PRIOR TO COMMENCING WORK ON THE STORE, THE GENERAL CONTRACTOR SHALL PROVIDE COPIES OF THE <br />COMMISSIONING SPECIFICATIONS IN THE LEED PROTOTYPE GREEN SPECIFICATIONS TO THE MECHANICAL, <br />ELECTRICAL, PLUMBING, AND CONTROLS SUB-CONTRACTORS. <br />9. FEEDER CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTAGE DROP OF 2% AT DESIGN LOAD. BRANCH <br />CIRCUIT CONDUCTORS SHALL BE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3% AT DESIGN LOAD. <br />10. ALL CONDUITS IN THE FRONT OF HOUSE SHALL BE INSTALLED IN A NEAT AND WORKMANSHIP LIKE MANNER. <br />CONDUITS SHALL BE GROUPED TOGETHER AS MUCH AS POSSIBLE TO GENERATE A CLEAN FEEL TO THE ROOM. <br />ALL QUESTIONS ON ROUTING SHALL BE COORDINATED WITH THE OWNER AND THE ARCHITECT TO ENSURE THAT <br />THE ELECTRICAL IS INSTALLED IN AN AESTHETICALLY PLEASING MANNER. <br />11. EMERGENCY LIGHTING <br />ALL EMERGENCY LIGHTS AND EXIT SIGNS SHALL BE CONNECTED TO AN UNSWITCHED LEG OF THE CIRCUIT <br />INDICATED. <br />KEY NOTES <br />1. SALES/SERVICE LIGHTING (C2) <br />ROUTE CIRCUIT THROUGH CONTACTOR "C2" AND CONTROL VIA VERIZON'S EXISTING EMS SYSTEM - <br />COORDINATE WITH EMS VENDOR. <br />2. OCCUPANCY SENSORS <br />INSTALL INFRARED OCCUPANCY SENSOR DEVICE FOR AUTOMATIC SHUTOFF CONTROL OF ROOM <br />LIGHTING. <br />ADJUST OCCUPANCY SENSOR TIME OUT DELAY TO 10 MINUTES FOR ALL SPACES. <br />OCCUPANCY SENSORS SHALL BE CAPABLE OF MANUAL ON/AUTOMATIC OFF OPERATION. <br />OCCUPANCY SENSORS SHALL BE POSITIONED AND ADJUSTED SO THAT SENSOR STATUS INDICATOR <br />BLINKS WHEN THE ROOM IS OCCUPIED, AND ACTIVATES WHEN A PERSON BREAKS THE PLANE OF THE <br />DOORWAY. OCCUPANCY SENSORS SHALL NOT TURN LIGHT ON WHEN PERSONS PASS AN OPEN <br />DOORWAY. <br />OCCUPANCY SENSOR SHALL BE PROVIDED BY LIGHT FIXTURE VENDOR PER THE OCCUPANCY SENSOR <br />SCHEDULE ON THIS SHEET. <br />OPERATION OF OCCUPANCY SENSORS AND LOCAL OVERRIDE SWITCHES SHALL BE, AT A MINIMUM, <br />PROGRAMMED TO FUNCTION IN ACCORDANCE WITH THE 2018 NEW HAMPSHIRE ENERGY CONSERVATION <br />CODE. <br />3. PROVIDE TRACK LIGTHING WITH 1A, 120V CURRENT LIMITING BREAKER (100% RATED). <br />4. FRONT OF HOUSE LIGHTING SWITCH BANK. REFER TO DETAIL 2 ON THIS DRAWING FOR MORE <br />INFORMATION. <br />5. PROVIDE OCCUPANCY SENSOR CONTROL WITH LOCAL MANUAL OVERRIDE FOR CONTROL OF OPEN <br />OFFICE 104. PER EXCEPTION TO IECC C405.2.1.1(2), AREA IS PERMITTED TO HAVE FULL-ON AUTOMATIC <br />CONTROL TO MAINTAIN THE SAFETY AND SECURITY OF THE ROOM, ITS OCCUPANTS. <br />6. PROVIDE TRACK LIGTHING WITH 2A, 120V CURRENT LIMITING BREAKER (100% RATED). <br />7. PROVIDE CONNECTION FOR NEW EMERGENCY EGRESS LIGHT TO GENERAL LIGHTING CIRCUIT OF <br />ADJACENT INTERIOR AREA AS SHOWN, UNSWITCHED -AHEAD OF LOCAL CONTROL AND CONTACTOR <br />CONTROL. <br /># <br />NOTE: <br />ALL CONDUIT RUNS IN RETAIL SALES TO BE GROUPED IN PARALLEL <br />CONFIGURATION, EQUALLY SPACED AND NEATLY ORGANIZED -COORDINATE <br />PLACEMENT W/ ALL OTHER TRADES. <br />NOTE: <br />REFER TO REFLECTED CEILING PLAN ON SHEET A.1.2 FOR DIMENSIONS TO ALL <br />LIGHT FIXTURES IN RETAIL SALES. <br />NOTE: <br />REFER TO FIXTURE HANGING DETAILS AND FIXTURE AIMING DETAILS ON <br />SHEET E.1.3. FOR SUPPORTS. COORDINATE W/ HVAC CONTRACTOR TO AVOID <br />INTERFERENCE. <br />SWITCHBANK GENERAL NOTES <br />1. ARRANGE SWITCHES AS INDICATED ABOVE. FIELD MODIFY ARRANGEMENT TO COMPLY WITH SPACE <br />LIMITATIONS AND CLEARANCE REQUIREMENTS. <br />2. PROVIDE FACTORY ENGRAVED FACE-PLATES AND LABELS WITH TEXT AS INDICATED. <br />3. ALL SWITCHES MUST BE COMPATIBLE WITH THE SYSTEM AND SHALL HAVE INTERNAL ILLUMINATION TO INDICATE <br />WHEN THE LIGHTS ARE ON, WHEN SWITCHES ARE NOT LOCATED IN THE SAME ROOM AS THE LIGHTS THEY ARE <br />CONTROLLING. <br />4. SEE LIGHTING CONTROL DEVICE SCHEDULE FOR ADDITIONAL INFORMATION. <br />5. PROVIDE SWITCHES AND WALL DIMMERS COMPATIBLE WITH POWER PACK/ROOM CONTROLLER SPECIFIED. <br />CONTRACTOR TO VERIFY LOAD RATING AND COMPATIBILITY WITH THE LIGHTING FIXTURES AND CONTACTOR <br />SYSTEM. SEE LIGHTING CONTROL DEVICE SCHEDULE FOR MORE INFORMATION. <br />6. PROVIDE 2-HR OVERRIDE SWITCH LEVITON 56080-2W FOR ALL RETAIL SALES AREA LIGHTING. <br />A#8 <br />A#2 <br />A#4 <br />A#2 <br />(VIA SWITCHLEG 'E') <br />(VIA SWITCHLEG 'A') <br />(VIA SWITCHLEG 'C') <br />A#4 <br />(VIA SWITCHLEG 'B') <br />A#4 <br />(VIA SWITCHLEG 'B') <br />A#6 <br />(VIA SWITCHLEG 'D') <br />A#22 <br />(VIA SWITCHLEG 'D') <br />F5-EMF5F5-EMF5 <br />F9F9 <br />F4A-DHF4A-DH <br />F4A-DH F4A-DH F4A-DH <br />F4A-DH F4A-DH F4A-DH <br />F8 F8 F8 F8 F8 F8 <br />F4B (16' - 0") <br />F4B (17' - 11") <br />F4B (19' - 6") <br />F4B (5' - 0") <br />ES-1 <br />CR22-EM CR22a CR22a CR22 CR22 <br />CR22 <br />CR22 <br />CR22-EMCR22CR22-EMCR22 <br />CR22-EM <br />CR22 <br />CR22 <br />F4B (13' - 0") <br />CR22 <br />F4B (8' - 0") <br />F4B (8' - 0") <br />CR22 <br />CR22 <br />CR22 <br />ES-1 <br />ES-1 <br />LIGHTING <br />CONTROL <br />PANEL <br />(LCP) <br />PANEL <br />A <br />PANEL <br />B <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />22 <br />2 <br />LV <br />4 <br />5 <br />5 <br />PP1 <br />PP1 E <br />PP2 D <br />PP1 B <br />PP1 A <br />PP2 C <br />PP1 B <br />F4A F4A F4A F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />PP2 D <br />6 <br />6 <br />6 <br />6 <br />3 <br />3 <br />3 <br />OS <br />LV <br />RETAIL SALES <br />101 <br />RESTROOM <br />102 <br />RESTROOM <br />103 <br />OPEN OFFICE <br />104 <br />INVENTORY <br />105 <br />MANAGER <br />106 <br />J.C. <br />107 <br />TELCO <br />108 <br />ES-1 <br />KK <br />KK <br />7 <br />7 <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />F4A <br />3 <br />Mechanical and Electrical Engineers <br />Lilker Associates <br />1001 Avenue of the Americas <br />New York, NY 10018 <br />tel 212.695.1000 <br />fax 212.695.1299 <br />www.lilker.com <br />Kenneth A. Gruskin AIA <br />No. Date Description <br />Consultant: <br />Checked By: <br />Drawn By: <br />Job Address: <br />Drawing Title: <br />Revision Issue: <br />Professional Seal: <br />Drawing Number: <br />2024 Gruskin Architecture + Design, P.C.c <br />This document and the ideas and designs incorporated <br />herein, as an instrument of professional service, is the <br />property of GRUSKIN ARCHITECTURE + DESIGN, P.C., <br />and is not to be used in whole or in part for any other <br />project without the written authorization of GRUSKIN <br />ARCHITECTURE + DESIGN, P.C. <br />North <br />Arrow: <br />Job Name and Number: <br />Date Issued For <br />All Rights Reserved <br />Client: <br />Landlord: <br />Permit: <br />Bid: <br />Construction: <br />0006261 <br />AR91629 <br />5421 <br />9613 <br />39209 <br />10635 <br />2537 <br />11016 <br />5734 <br />ARC 2596 <br />4674 <br />2666 <br />AI 09999 <br />2796 <br />0401 011223 <br />2572 <br />17680 <br />RA-015432-B <br />025528-1 NY <br />TX <br />VA <br />VT <br />MA <br />MT <br />RI <br />PA <br />NY <br />NJ <br />NH <br />MD <br />LA <br />ME <br />KS <br />FL <br />DE <br />CT <br />AZ <br />AL <br />C-1967WY <br />RA011075GA <br />AR10400066IN <br />C-29898CA <br />NM 004168 <br />ARC-400347CO <br />HI AR 11489 <br />PR 19965 <br />OR 4899 <br />SC 6834 <br />NC 9961 <br />13761OH <br />05713IA <br />WV 3727 <br />IL 001-019152 <br />UT 5881358-0301 <br />ID AR-984459 <br />1301052379MI <br />ARC100723DC <br />WI 9900-005MN44326 <br />A-3547NE <br />3811AR <br />5967KY 101374TN <br />MS 3860 <br />1666ND <br />A-2005029740MO <br />a4895OK <br />NV 5521 <br />WA 10344 <br />13167AK <br />SD 11532 <br />C: <br />\ <br />R <br />e <br />v <br />i <br />t <br /> <br />L <br />o <br />c <br />a <br />l <br /> <br />F <br />i <br />l <br />e <br />s <br />\ <br />2 <br />4 <br />0 <br />0 <br />1 <br />3 <br />0 <br />8 <br />_ <br />V <br />E <br />R <br />I <br />Z <br />O <br />N <br />_ <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />_ <br />C <br />A <br />_ <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br />_ <br />v <br />2 <br />3 <br />_ <br />M <br />H <br />o <br />a <br />n <br />g <br />E <br />P <br />E <br />A <br />V <br />. <br />r <br />v <br />t <br />2023-0069 <br />Proposed <br />Store Design <br />for: VERIZON <br />3500 South Bristol Street <br />Suite 100 <br />Santa Ana, CA 92704 <br />3/15/24 <br />3/15/24 <br />4/5/24 <br />LIGHTING FLOOR PLAN <br />E.1.2 <br />DB <br />MH <br />51 OF 81 <br />3" = 1'-0"2 F.O.H. LIGHTING SWITCH BANK DIAGRAM <br />1/4" = 1'-0"1 LIGHTING FLOOR PLAN <br />1 4/15/24 Addendum 1 : HQ Update <br />3 6/3/24 City Comments <br />3500 S Bristol St Unit# 100 - <br />101119098, 20182666 & <br />401390437/11/2024