Laserfiche WebLink
RESERVOIR RACEWAY <br />CO <br />N <br />T <br />R <br />O <br />L <br />PA <br />N <br />E <br />L <br />FRONT <br />REAR <br />RIGHTLEFT <br />FRONT <br />REAR <br />RIGHTLEFT <br />2ACCU <br />1B <br />20-TONS <br />1,126 LBS. <br />7KEF <br />1 <br />229 LBS. <br />W/ CURB <br />7KEF <br />2 <br />222 LBS. <br />W/ CURB <br />7KEF <br />3 <br />132 LBS. <br />W/ CURB <br />7KEF <br />6 <br />126 LBS. <br />W/ CURB <br />7KEF <br />5 <br />234 LBS. <br />W/ CURB <br />7KEF <br />4 <br />258 LBS. <br />W/ CURB <br />5RTU <br />1 <br />1,369 LBS. <br />W/ CURB <br />5RTU <br />2 <br />1,369 LBS. <br />W/ CURB <br />5RTU <br />3 <br />1,370 LBS. <br />W/ CURB <br />5 RTU <br />4 <br />1,370 LBS. <br />W/ CURB <br />1AHU <br />1 <br />40-TONS <br />6,429 LBS. <br />6 SF <br />1 <br />191 LBS. <br />7EF <br />1 <br />77 LBS. <br />2CU <br />1 <br />1.5-TONS <br />119 LBS. <br />9 <br />10"Ø <br />8 <br />(TYP.) <br />8 <br />(TYP.) <br />254T-256T <br />10 <br />6"Ø <br />1112 <br />AD <br />J <br />A <br />C <br />E <br />N <br />T <br /> <br />R <br />O <br />O <br />F <br />2ACCU <br />1A <br />20-TONS <br />1,126 LBS. <br />REFRIGERATION <br />EQUIPMENT BY OTHERS <br />3' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />20 <br />' <br />- <br />5 <br />" <br />RECOMMENDED <br />MINIMUM CLEARANCES <br />(TYP.) <br />8 <br />(TYP.) <br />9 <br />8"Ø <br />23XX <br />26575 Ruether Ave 2nd floor <br />CH <br />A <br />R <br />C <br />Santa Clarita, CA 91350 <br />661.383.2352 - 818.919.2248 <br />MECHANICAL ROOF PLAN <br />SHEET NOTES: <br />REFER TO MECHANICAL LEAD SHEETS FOR LEGENDS, <br />ABBREVIATIONS AND GENERAL NOTES. <br />ENVIRONMENTAL EXHAUST OUTLETS SHALL TERMINATE <br />NO LESS THAN 3 FEET FROM PROPERTY LINE, 3 FEET <br />FROM OPENINGS INTO BUILDING, 10 FEET FROM A <br />FORCED AIR INLET, AND SHALL NOT DISCHARGE ONTO A <br />PUBLIC WALKWAY. <br />CONTRACTOR SHALL VISIT THE SITE, VERIFY SITE <br />CONDITIONS, IDENTIFY ALL OBSTRUCTIONS, EXACT <br />ROUTING OF DUCTWORK SHALL BE CONTRACTORS <br />RESPONSIBILITY. PROVIDE REQUIRED TRANSITIONS <br />DUCT FITTINGS ETC. TO AVOID ANY OBSTRUCTIONS. <br />KEYED NOTES: <br />1 <br />2 <br />3 <br />4 <br />5 <br />AIR HANDLING UNIT MOUNTED ON ROOF. <br />AIR COOLED CONDENSING UNIT MOUNTED ON SPRING <br />ISOLATORS. <br />70"x36" SUPPLY AIR DUCT DN THRU ROOF. <br />70"x36" RETURN AIR DUCT DN THRU ROOF. <br />PACKAGED GAS/ELECTRIC AIR CONDITIONING UNIT WITH <br />ROOF CURB. <br />6 ROOF MOUNTED MAKE-UP AIR UNIT. <br />7 <br />8 <br />EXHAUST DUCT UP THRU ROOF WITH ROOF CAP.9 <br />10'-0" EXHAUST RADIUS. NO OUTSIDE AIR INTAKES ALLOWED <br />IN THIS AREA. <br />10 OSA DUCT UP THRU ROOF. <br />ROOF MOUNTED EXHAUST FAN. <br />2. <br />1. <br />3. <br />11 <br />12 <br />54"x30" LINED SUPPLY AIR DUCT DOWN THRU ROOF. <br />54"x30" LINED RETURN AIR DUCT DOWN THRU ROOF. <br />APPLIANCES SHALL BE INSTALLED ON A WELL-DRAINED <br />SURFACE ON THE ROOF. <br />4. <br />HOLD- 420 W 17th <br />St3/7/2025