Laserfiche WebLink
SCALE <br />NONE <br />SCALE <br />NONE <br />SCALE <br />NONE <br />46 2 <br />5 <br />37 <br />SCALE <br />NONE 1 <br />23XX <br />26575 Ruether Ave 2nd floor <br />CH <br />A <br />R <br />C <br />Santa Clarita, CA 91350 <br />661.383.2352 - 818.919.2248 <br />CU <br />- <br />FC <br />- <br />TTHERMOSTAT <br />PROGRAMMABLE <br />DISC <br />208/230V-1Ø-60HZ <br />LOW VOLTAGE WIRING NUMBER OF WIRES <br />PER MANUFACTURERS RECOMMENDATIONS <br />MOUNTED ON WALL <br />ALL LINE VOLTAGE CONDUIT, WIRING, AND EQUIPMENT SHOWN SOLID SHALL BE <br />FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. <br />LEGEND <br />SPLIT SYSTEM CONTROL DIAGRAM <br />FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. <br />FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. <br />ALL LINE VOLTAGE CONDUIT, WIRING, AND EQUIPMENT SHOWN DASHED SHALL BE <br />FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. <br />EXHAUST ROOF CAP DETAIL <br />ROOFING <br />FIBER CANT <br />FACTORY SUPPLIED <br />ROOF CAP <br />#8 SCREW & WASHER <br />3/8" LAG SCREW ANCHORED <br />TO WOOD BLOCKING <br />WOOD BLOCKING <br />FACTORY SUPPLIED <br />ROOF CURB <br />FLOOR PLAN FOR SIZE. <br />EXHAUST DUCT. SEE <br />(E) ROOF <br />(E)ROOF JOIST <br />SEE STRUCTURAL <br />SCALE <br />NONE <br />SCALE <br />NONE <br />SCALE <br />NONE <br />24"x24" RETURN AIR GRILLE WITH <br />ACCESS PANEL ASSEMBLY (UP <br />FLASHING BY <br />MECHANICAL <br />SIGHT GLASS IN <br />LIQUID LINE <br />FILTER/DRYER IN <br />LIQUID LINE <br />CONTRACTOR <br />FOR INSULATION <br />EXPOSED OUTDOORS <br />PROVIDE METAL CLADDING <br />CU <br />- <br />FC <br />- <br />CEILING <br />NON-LOUVERED ACCESS <br />PANEL. SIZE TO MATCH <br />FAN COIL UNITS <br />RETURN AIR <br />PLENUM <br />FILTER FACE AREA <br />SUFFICIENT FOR MAX. <br />SECTIONAL ELEVATION <br />FILTER <br />FC <br />- <br />PLAN <br />FLEXIBLE <br />SUPPLY <br />FLEXIBLE <br />SUPPLY DUCT <br />250 FT/MIN FACE VEL. <br />DUCTS <br />TO 1000 CFM ONLY) <br />FLEX CONNECTOR <br />SHEET METAL <br />AT SIDES OF FILTER <br />46"x24.5"1 <br />PANEL SIZEFCU <br />2 <br />3 <br />OUTSIDE AIR DUCT <br />OUTSIDE AIR DUCT <br />CAN BE CONNECTED <br />IN 3 SIDES. <br />WITH VOLUME DAMPER <br />WITH VOLUME DAMPER <br />46"x24.5" <br />46"x24.5" <br />AIR FILTER GAGE <br />NORDICPURE G99 <br />EQUIPMENT PLATFORM WITH <br />NEOPRENE/SPRING ISOLATOR <br />3/4" COND DRAIN <br />TO APPROVED <br />RECEPTOR <br />CEILING MOUNTED SPLIT HP INSTALLATION DETAIL <br />DUCT HANGER DETAIL <br />REQ'D. PER "SMACNA"- TYPICAL <br />LONGITUDINAL BRACING WHEN <br />TRANSVERSE BRACING AND <br />3" <br />PROVIDE TRANSVERSE BRACING AT 3O FT. AND LONGITUDINAL BRACING AT 60 FT. WHEN REQUIRED <br />EXCERPT FROM TABLE 5-1 RECTANGULAR DUCT HANGERS MINIMUM SIZE OF SMACNA <br />PER TABLE 7-1 2008 SMACNA SEISMIC RESTRAINT MANUAL, 3RD EDITION. <br />2005 HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE, 3RD EDITION <br />1"X 18 GA. <br />1"X 22 GA. <br />2. <br />NOTES: <br />1. <br />MAX. HALF OF <br />P/2 =72 <br />P/2 =30 <br />PERIMETER/IN. <br />DUCT <br />PAIR AT 10 FT SPACING <br />TYPICAL SQUARE OR <br />RECTANGULAR DUCTWORK <br />1" <br />3/8" <br />10 GA. <br />#10 SELF-TAPPING <br />S.M.S. EQUALLY SPACED <br />12" O.C. MAX. (TYPICAL) <br />TO NOTE #2 BELOW <br />ROUND DUCT <br />TYPICAL <br />MAX. <br />45° <br />12" <br />GALVANIZED SHEET <br />DIAGONAL BRACING REFER <br />METAL STRAP OR ROD <br />HANGER (REFER TO <br />SCHEDULE BELOW) <br />WHEN REQ'D <br />BRACING <br />3/8"Ø <br />MACHINE <br />BOLT <br />GALVANIZED SHEET <br />METAL STRAP OR ROD <br />HANGER (REFER TO <br />SCHEDULE BELOW) <br />STRAP WIRE/ROD <br />1"X 20 GA. <br />1"X 22 GA. <br />PAIR AT 8 FT SPACING <br />1/4" <br />12 GA. <br />STRAP WIRE/ROD <br />1"X 22 GA. <br />1"X 22 GA. <br />PAIR AT 5 FT SPACING <br />1/4" <br />12 GA. <br />STRAP WIRE/ROD <br />1"X 22 GA. <br />1"X 22 GA. <br />PAIR AT 4 FT SPACING <br />1/4" <br />12 GA. <br />STRAP WIRE/ROD <br />1"X 18 GA.P/2 =96 3/8"1"X 20 GA.1/4"1"X 22 GA.1/4"1"X 22 GA.1/4" <br />SINGLE HANGER MAXIMUM ALLOWABLE LOAD <br />STRAP WIRE OR ROD (DIA.) <br />WHEN STRAPS ARE LAP JOINED USE <br />THESE MAXIMUM FASTENERS <br />1"X18, 20, 22 GA - TWO #10 OR ONE 1/4" BOLT <br />1"X16 GA - TWO 1/4" DIA. <br />1-1/2"X16 GA - TWO 3/8" DIA. <br />PLACE FASTENERS IN SERIES, NOT SIDE BY SIDE. <br />1"X22 GA - 260 LBS. <br />1"X20 GA - 320 LBS. <br />1"X18 GA - 420 LBS. <br />1"X16 GA - 700 LBS. <br />0.106" - 80 LBS. <br />0.135" - 120 LBS. <br />0.162" - 160 LBS. <br />1/4" - 270 LBS. <br />3/8" - 680 LBS. <br />TO NOTE #2 BELOW <br />DIAGONAL BRACING REFER <br />PROVIDE TRANSVERSE BRACING AT 3O FT. AND LONGITUDINAL BRACING AT 60 FT. WHEN <br />EXCERPT FROM TABLE 5-2 MINIMUM HANGER SIZE FOR ROUND DUCT OF SMACNA <br />REQUIRED PER TABLE 7-1 2008 SMACNA SEISMIC RESTRAINT MANUAL, 3RD EDITION. <br />2005 HVAC DUCT CONSTRUCTION STANDARDS METAL AND FLEXIBLE, 3RD EDITION <br />2. <br />NOTES: <br />1. <br />12 FT. <br />12 FT. <br />11" THRU 18" <br />10" & SMALLER <br />DUCT DIA.MAXIMUM <br />TWO 12 GA. OR ONE 8 GA. <br />ONE 12 GA. <br />1/4" <br />1/4" <br />1"X 22 GA. <br />1"X 22 GA. <br />12 FT.19" THRU 24"TWO 10 GA.1/4"1"X 22 GA. <br />SPACING <br />WIRE <br />DIA. <br />ROD STRAP <br />12 FT.25" THRU 36"TWO 8 GA.3/8"1"X 20 GA. <br />2 <br />M4.0 <br />2 <br />M4.02 <br />M4.0 <br />2 <br />M4.0 <br />- NOT USED - <br />- NOT USED - <br />- NOT USED - <br />HOLD- 420 W 17th <br />St3/7/2025