23XX
<br />26575 Ruether Ave 2nd floor
<br />CH
<br />A
<br />R
<br />C
<br />Santa Clarita, CA 91350
<br />661.383.2352 - 818.919.2248
<br />YARD BOXY.B.REMOVE/ABANDON
<br />ABOVE
<br />INDIRECT
<br />REDUCED PRESSURE B.F.P.
<br />BACKFLOW PREVENTER
<br />IND
<br />RP
<br />ABV.
<br />B.F.P.
<br />DRAIN
<br />GW
<br />D
<br />PC/SOC
<br />D
<br />GW
<br />PLUG COCK / SHUT-OFF COCK
<br />GREASE WASTE
<br />NOT IN PLUMBING CONTRACTN.I.P.C.
<br />FD or AD FLOOR OR AREA DRAIN
<br />PRESSURE REDUCING VALVE
<br />POINT OF CONNECTION
<br />P.R.V.
<br />P.O.C.
<br />REQUIRED
<br />VENT THRU ROOF
<br />RECTANGULAR
<br />POLYVINYLCHLORIDE
<br />V.T.R.
<br />REQ'D
<br />RECT.
<br />P.V.C.
<br />FCO
<br />RD OR OD
<br />WCO
<br />FLOOR CLEANOUT
<br />ROOF OR OVERFLOW DRAIN
<br />WALL CLEANOUT
<br />FLOOR
<br />HEATER
<br />INVERT ELEVATION
<br />GALLONS PER MINUTE
<br />FIXTURE UNIT
<br />FINISHED FLOOR
<br />I.E.
<br />G.P.M.
<br />HTR.
<br />FLR.
<br />F.U.
<br />FIN. FLR.
<br />STORM DRAIN
<br />FLOOR SINK
<br />CHECK VALVE
<br />SD
<br />OD
<br />FS
<br />CWV
<br />CV
<br />GV/SOV
<br />CWV
<br />SD
<br />OD
<br />COMBINATION WASTE AND VENT
<br />GATE VALVE / SHUT OFF VALVE
<br />OVERFLOW STORM DRAIN
<br />BELOWBEL.HW HOT WATER LINE
<br />CONNECT
<br />CONCRETE
<br />CAST IRON
<br />CEILING
<br />EXISTING
<br />DOWN
<br />C.I.
<br />DN.
<br />CLG.
<br />EXIST.
<br />CONN.
<br />CONC.
<br />GAS LINE
<br />VENT LINEV
<br />G
<br />HWR
<br />CD
<br />DOWNSPOUTDS
<br />S or W
<br />S or W
<br />G
<br />DS
<br />CD
<br />SOIL OR WASTE - SUSPENDED
<br />SOIL OR WASTE BELOW FLR OR GRADE
<br />HOT WATER RETURN
<br />CONDENSATE DRAIN
<br />DESCRIPTIONABBREV.
<br />CW
<br />ABBREV.SYMBOL
<br />PLUMBING LEGEND
<br />DESCRIPTION
<br />COLD WATER LINE
<br />(E)
<br />NEW(N)
<br />PIPE SPECIFICATIONS
<br />3. CONDENSATE DRAINS...
<br />4. WASTE & VENT:
<br />GENERAL NOTES
<br />1. SLOPE ALL SOIL & WASTE LINES MIN. 2% (¼" PER FT.)
<br />7. PLUMBING CONTRACTOR SHALL VERIFY LOCATION OF SITE PIPING AND CABLES BEFORE TRENCHING.
<br />11. RECOMPACT ALL PLUMBING EXCAVATION.
<br />13. VERIFY SIZE, LOCATION, DEPTH, ETC., OF ALL UTILITIES IN THE FIELD.
<br />14. ALL FLOOR SINKS UNDER CASES OR EQUIPMENT SHALL BE HALF EXPOSED.
<br />20. NO CLEANOUTS SHALL OCCUR UNDER OR BEHIND ANY CASE OR FIXTURE.
<br />22. ALL LINES TO BE LOCATED AWAY FROM BEARING FOOTING, OR AS DIRECTED BY STRUCTURAL ENGINEER.
<br />27. ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY.
<br />29. BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH SECTIONS 701.0 AND 903.0 OF CPC.
<br />SERVICE - WATER NOTES
<br />1.ALL SERVICE HOT WATER PIPE RUNS GREATER THAN 12'-0" SHALL BE INSULATED
<br />ACCORDING TO THE REQUIREMENTS SET IN SECTION 609.11.1 AND 609.11.2 OF
<br />THE 2022 CPC.
<br />2.PLUMBING FIXTURES SHALL BE CERTIFIED BY THE CALIFORNIA ENERGY
<br />COMMISSION.
<br /> FIXTURE TOTAL PRESS. (PSIG) MAX FLOW RATE
<br /> SINK FAUCETS 20 - 60 1.8 GPM
<br /> URINAL 20 - 80 0.125 GPF
<br />FILTERED COLD WATERFCWPIPE TEE DOWN
<br />PIPE TEE UP
<br />PIPE DOWN/FROM BELOW
<br />PIPE UP
<br />TAG FIXTURE WASTE TRAP VENT COLD
<br />WATER WATER
<br />HOT REMARKS
<br />PLUMBING FIXTURE SCHEDULE
<br />TRAP PRIMER - M1FAB M2-500 -1/2"---TP
<br />SHEET INDEX
<br />SHT.NO.DESCRIPTION
<br />P-0.0 PLUMBING GENERAL NOTES, ABBREVIATIONS AND SCHEDULES
<br />P-1.0 PLUMBING ADDITIONAL NOTES AND CALCULATIONS
<br />P-2.0
<br />PLUMBING FLOOR PLAN - DOMESTIC WATER
<br />POINT OF DISCONNECTIONP.O.D.
<br />PLUMBING FLOOR PLAN - WASTE & VENT
<br />MS 1/2"1/2"2"2"
<br />2"2"
<br />1-1/2"
<br />1-1/2"
<br />P-2.2
<br />S2
<br />2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - KINTERA MANUFACTURING
<br />MODEL KES3C1818S-218S3
<br />24" X 24" ADVANCE TABCO MODEL 9-OP-4. WITH VACUUM
<br />BREAKER SPOUT, 3/4 HOSE THREAD
<br />4"INT.2"1-1/2"-WC FLUSH VALVE WATER CLOSET. ADA COMPLIANT
<br />BY ARCHITECTS/OWNER
<br />L 1-1/2"1/2"2"2"1/2"
<br />FS --1-1/2"2"2"INSTALL COMPLETE WITH DOME STRAINER & HALF GRATE.
<br />PROVIDE TRAP PRIMER
<br />HALF GRATE - 12"W x 12"D x 6"H FLOOR SINK.
<br />ZURN Z1910 OR APPROVED EQUAL
<br />1/2"1/2"2"2"1-1/2"
<br />FD --1-1/2"2"2"IRON ADJUSTABLE TRACTOR GRATE, SEDIMENT BUCKET
<br />PROVIDE TRAP PRIMER8" Ø FLOOR DRAIN. WATTS FD-100-A
<br />HS GSW - MODEL HS-1615S-N HAND SINK ASSEMBLY
<br />OR APPROVED EQUAL 1/2"1/2"2"2"1-1/2"
<br />WITH VACUUM BREAKER (AIR-BREAK BACK FLOW) FAUCET
<br />SPOUT, 3/4 HOSE THREAD. ZURN Z841M-XL 1.8 GPM
<br />T&S - B-2342 FAUCET 1.5 GPM AERATOR.
<br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS.
<br />T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR.
<br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS.
<br />T&S FAUCET MUST HAVE A FLOWRATE OF NO MORE THAN 1.8 GPM.
<br />SINK MUST BE PROVIDED WITH WALL BRACKETS.
<br />ELECTRONIC TRAP PRIMER - SIOUX CHIEF 695-ES01 -1/2"---TP2
<br />2 COMPARTMENT SINK - BK BKS-2-18-14-18TS
<br />OR APPROVED EQUAL
<br />WITH SOV & RUN 1/2" TRAP PRIMER LINE TO ALL FLOOR DRAIN
<br />AND FLOOR SINK
<br />WITH SOV & RUN 1/2" TRAP PRIMER LINE TO ALL FLOOR DRAIN
<br />AND FLOOR SINK
<br />6" W. TRENCH DRAIN. ZURN Z890 -2"3"3"TD RUN 1/2" TRAP PRIMER LINE TO TRENCH DRAIN P-TRAP
<br />P-3.0 PLUMBING DETAILS - WATER HEATER SYSTEM
<br />LAVATORY. SHALL BE ADA COMPLIANT BY
<br />ARCHITECTS/OWNER
<br />P-2.4 PLUMBING ROOF PLAN
<br />P-3.1 PLUMBING DETAILS
<br />TAG MAKE & MODEL
<br />GPH @ 70°F RISE
<br />RECOVERY REMARKS
<br />PLUMBING EQUIPMENT SCHEDULE
<br />MODEL ST-35-CL
<br />AMTROL FACTORY PRECHARGED OF 38 PSIET-1 --3.2
<br />-RCP-1
<br />STORAGE
<br /> CAP. (GALS.)
<br />ELECTRICAL
<br />HP V PH HZ
<br />WATER TEMP.
<br />IN (°F)OUT (°F)WT. (LBS.)
<br />SHIPPINGGAS (MBH)
<br />INPUT
<br />------40
<br />----0.167 HP 120 1 --12 INSTALL PER MANUFACTURER'S INSTALLATION
<br />AND OPERATING INSTRUCTIONS
<br />AOSMITHWH-3 658140100-120 1 60 70BTH-150 Mxi 150 553
<br />TACO SERIES 0013
<br />PIPE INSULATION SCHEDULE
<br />PIPING SERVICE MATERIALS
<br />CONDENSATE DRAIN
<br />THICKNESS
<br />3/4"
<br />INSULATION SHALL BE ONE-PIECE PREFORMED GLASS FIBER INSULATION
<br />WITH INTEGRAL ALL-PURPOSE FIRE RETARDANT, GLASS YARN SCRIM
<br />LAMINATED, WHITE JACKET, âKâ FACTOR SHALL BE 0.23 MAXIMUM
<br />AT 75 DEGREES F. MEAN TEMPERATURE.
<br />INSULATION
<br />INSULATION SHALL BE ONE-PIECE PREFORMED GLASS FIBER INSULATION
<br />WITH INTEGRAL ALL-PURPOSE FIRE RETARDANT, GLASS YARN SCRIM
<br />LAMINATED, WHITE JACKET, âKâ FACTOR SHALL BE 0.23 MAXIMUM
<br />AT 75 DEGREES F. MEAN TEMPERATURE.
<br />DOMESTIC HOT WATER
<br />SUPPLY & RETURN
<br />SIZE
<br />PIPE
<br />1"1/2" & 3/4"
<br />1-1/2"1" & 1 1/4"
<br />3/4"
<br />FF FILL FAUCET - FISHER MANUFACTURING POT FILLER HOSE STYLE
<br />SINGLE WALL MOUNT 3/4"FAUCET MUST HAVE A FLOWRATE OF NO MORE THAN 1.8 GPM.
<br />WHA WATER HAMMER ARRESTOR BY PDI
<br />OR APPROVED EQUAL 1"WITH ACCESS PANEL. PROVIDED AS SUGGESTED BY PDI.
<br />---
<br />---
<br />-
<br />-
<br />PLUMBING FLOOR PLAN - GAS & CONDENSATEP-2.3AOSMITHWH-4 658140100-120 1 60 70BTH-150 Mxi 150 553
<br />P-3.2 PLUMBING DETAILS
<br />DF DRINKING WATER FOUNTAIN ELKAY EZ0TL8WSSK
<br />OR APPROVED EQUAL
<br />1/2"SHALL BE MOUNTED AND INSTALLED PER MANUFACTURER'S
<br />INSTALLATION AND OPERATING MANUAL----
<br />S1 1/2"1/2"2"2"1-1/2"T&S - 5PR-8W08 FAUCET 1.5 GPM AERATOR.
<br />INSTALL P-TRAP AND DIRECT WASTE TO SEWER LINE
<br />SINGLE COMPARTMENT SINK KINTERA KES1C1818-L18
<br />- OR APPROVED EQUAL
<br />1.WATER.... TYPE "K" SOFT COPPER TUBING BELOW FLOOR OR GRADE.
<br /> TYPE "L" HARD DRAWN COPPER TUBING WITH WROUGHT SOLDER JOINT FITTINGS ABOVE FLOOR OR GRADE.
<br />2.GAS..........SCHEDULE 40 BLACK STEEL PIPE WITH BLACK MALLEABLE IRON SCREWED FITTINGS.
<br /> EXPOSED TO WEATHER SHALL BE GALVANIZED, STEEL PIPE.
<br />TYPE "L" HARD DRAWN COPPER TUBING WITH WROUGHT SOLDER JOINT FITTINGS.
<br />EMERGENCY EYE WASHEEW
<br />2"INT.2"1-1/2"-UR URINAL ADA COMPLIANT BY ARCHITECTS/OWNER
<br />WATER HAMMER ARRESTORWHA
<br />KOHLER OR APPROVED EQUAL
<br />INSTALL AT ADA COMPLIANT - REFER TO ARCH DWGS. PROVIDE 1-1/4"
<br />CW SUPPLY ROUGH IN PER CPC 2022 403.3.1
<br />HB1 WALL HYDRANT - ZURN 1305-VB 3/4"WITH VACUUM BREAKER LOSE KEY STOP & LOCK & VANDAL PROOF
<br />SCREWS, NICKLE BRONZE, FINISH, INSTALL @+18"
<br />HB2 3/4"
<br />HB3 3/4"
<br />---
<br />---
<br />---
<br />3/4"
<br />HB4 3/4"WITH LOOSE KEY STOP AND VACUUM BREAKER----
<br />HB5 3/4"3/4" CW W/ WILKINS (MODEL BFP-8F) VACUUM BREAKER W/ LOOSE
<br />KEY STOP AND VANDAL PROOF SCREWS = PROVIDED BY G.C.----
<br />WITH THE VACUUM BREAKER, WALL MOUNTED, LESS DOOR WITH
<br />VACUUM BREAKER AND VANDAL PROOF SCREWS
<br />-
<br />HOT & CW HOSE BIBB - KROWNE ROYAL SERIES MODEL 24-503
<br />WALL HYDRANT - ACORN 8146
<br />WALL HYDRANT - ACORN 8126
<br />WALL HYDRANT - ACORN 8126
<br />INSTALL PER INSTALLATION AND OPERATING MANUAL
<br />REMARKS/SPECIFICATIONSSYMBOL
<br />CONNECTION
<br />H.W.C.W.
<br />BFP --
<br />PLUMBING EQUIPMENT SCHEDULE
<br />PRV -2" BACKFLOW WATER PREVENTER CAST IRON -
<br />INSTALL PER MANUFACTURER'S INSTALLATION
<br />AND OPERATING INSTRUCTIONS
<br />2" BACKFLOW PREVENTER
<br />WILKINS 975XL
<br />MANUFACTURER
<br />MODEL GPM
<br />FLOW
<br />PSI
<br />LOSS
<br />PRESS.
<br />LOCATION
<br />AT METER
<br />RP-2 --INSTALL PER MANUFACTURER'S INSTALLATION
<br />AND OPERATING INSTRUCTIONS
<br />1-1/4" BACKFLOW PREVENTER
<br />WILKINS 975XL2 RPBFP
<br />FOR EVAP COND.15 8.0
<br />RP-3 --INSTALL PER MANUFACTURER'S INSTALLATION
<br />AND OPERATING INSTRUCTIONS
<br />3/4" BACKFLOW PREVENTER
<br />WILKINS 909 RP SEE SHEET P-3.11510.0
<br />2" PRESSURE REDUCING
<br />VALVE WILKINS 500XL 62 7.0
<br />(FIELD VERIFY)
<br />INSTALL PER MANUFACTURER'S INSTALLATION
<br />AND OPERATING INSTRUCTIONS
<br />REFER TO SHEET P-3.0
<br />INSTALL PER MANUFACTURER'S INSTALLATION
<br />AND OPERATING INSTRUCTIONS
<br />REFER TO SHEET P-3.0
<br />CO-1 ---
<br />CO-2 INSTALL IN WORK AREA FLOORS AND EXTERIOR WALKS WITH
<br />EXTRA HEAVY CAST IRON TOP---
<br />CO-3 INSTALL AT ALL TYPE WALL CONSTRUCTION AND FINISHES---
<br />CLEAN OUT - J.R. SMITH 4100 - NB
<br />CLEAN OUT - J.R. SMITH 4100 - G
<br />CLEAN OUT - J.R. SMITH 4472PC
<br />INSTALL IN SALES AREA FLOORS WITH NICKEL-BRONZE TOP-
<br />-
<br />-
<br />2", 3", OR 4"
<br />2", 3", OR 4"
<br />2", 3", OR 4"
<br />SERVICE WEIGHT HUBLESS CAST IRON PIPES AND FITTINGS, WRAPPED WITH 3 MIL. PLASTIC
<br />5. SANITARY SEWER:
<br />SERVICE WEIGHT HUBLESS CAST IRON PIPES AND FITTINGS, WRAPPED WITH 3 MIL. PLASTIC
<br />6. SINK DRAINS:
<br />TYPE "DWV" COPPER DRAINAGE TUBE WITH WROT SOLDER JOINT FITTINGS ONLY. (ABS AND PVC PIPING
<br />PROHIBITED)
<br />7. REFRIGERATION DRAINS:
<br />TYPE "M" COPPER DRAINAGE TUBE WITH WROT SOLDER JOINT FITTINGS ONLY.
<br />(ABS AND PVC PIPING PROHIBITED)
<br />8. SINK DRAIN VALVES:
<br />ROTARY WASTE VALVES WITH LEVER / TWIST HANDLES SHALL BE INSTALLED AT ALL 1, 2,
<br />AND 3 COMPARTMENT SINKS, ETC. ONLY. MANUAL SINK DRAIN STOPPERS ARE PROHIBITED.
<br />P-2.1
<br />PLUMBING DEMO PLAN
<br />ELONGATED TOILET, VITREOUS CHINA WITH OPEN SEAT
<br />WHITE,1.28 GPF. ADA COMPLIANT
<br />MATERIAL AT ALL UNDER GROUND LOCATIONS ONLY
<br />- IN ADDITION ABS OR SCHEDULE 40 CPVC PIPING, SHALL BE INSTALLED BELOW SLAB OR GRADE ONLY,
<br />APPROVED BY AUTHORITY HAVING JURISDICTION (AJH)
<br />MATERIAL AT ALL UNDER GROUND LOCATIONS ONLY
<br />- IN ADDITION ABS OR SCHEDULE 40 CPVC PIPING, SHALL BE INSTALLED BELOW SLAB OR GRADE ONLY,
<br />APPROVED BY AUTHORITY HAVING JURISDICTION (AJH)
<br />2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - BK BKS-3-1824-14-18T
<br />OR APPROVED EQUALS4 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR.
<br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS.
<br />2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - JOHN BOOS "3BCS" - 3BCS-184-2D18S5 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR.
<br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS.
<br />3/4"
<br />33. ADDITIONAL PIPING NOTES:
<br />a. ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED
<br /> SYNTHETIC LATEX PAINTS. (CPC 906.1).
<br />b. SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT EXCEED THOSE SHOWN IN TABLE 313.
<br /> 2022 CPC SEC. 313.3
<br />2.DRAWINGS ARE DIAGRAMATIC. DO NOT SCALE PLUMBING PLANS FOR EXACT HORIZONTAL LOCATION OF
<br />PIPE RUNS.
<br />3.SUPPLY ROUGH-IN, INSTALL AND CONNECT PLUMBING FIXTURES AS REQUIRED UNLESS OTHERWISE NOTED.
<br />4.VERIFY & COORDINATE ROUGH-IN AND FIXTURE LOCATIONS WITH ARCHITECTURAL DWGS. PRIOR TO
<br />FABRICATION OR INSTALLATION OF MATERIALS AND AGAIN PRIOR TO SLAB POUR.
<br />5.VERIFY ALL ELECTRICAL CHARACTERISTICS WITH ELECTRICAL PLANS PRIOR TO BID OR MATERIAL
<br />PURCHASE.
<br />6.WORK SHALL NOT BE COVERED UNTIL IT HAS BEEN INSPECTED, TESTED AND APPROVED BY THE
<br />PLUMBING INSPECTOR OR OTHER GOVERNMENTAL AUTHORITIES HAVING JURISDICTION.
<br />8.PROVIDE ACCESS DOORS TO ALL CONCEALED VALVES. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE
<br />NOTED.
<br />9.FLUSH VALVES, FAUCETS, STOPS BUBBLERS, ETC., SHALL BE ADJUSTED TO THEIR NORMAL WORKING
<br />CONDITIONS.
<br />10.ALL LABOR AND MATERIALS SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE OF THE
<br />COMPLETED WORK BY THE ARCHITECT, WITH SERVICE, REPLACEMENT OR REPAIR MADE AT NO EXTRA
<br />COST TO THE OWNER OR TENANT.
<br />12.ALL MATERIALS, EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO ALL REQUIREMENTS OF ALL
<br />APPLICABLE CITY, COUNTY, STATE AND FEDERAL CODES, ORDINANCES & REGULATIONS.
<br />P-4.0 PLUMBING RISER DIAGRAM - DOMESTIC WATER
<br />P-4.1 PLUMBING RISER DIAGRAM - WASTE & VENT
<br />32.SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED THOSE SHOWN IN TABLE 313.3.
<br />2022 CPC SEC. 313.3.
<br />31.ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED SYNTHETIC LATEX
<br />PAINTS. (CPC 906.1).
<br />30.NO WATER-OPERATED EQUIPMENT OR MECHANISM, OR USE A WATER-TREATING CHEMICAL OR
<br />SUBSTANCE, WHERE IT IS FOUND THAT SUCH EQUIPMENT, MECHANISM, CHEMICAL, OR SUBSTANCE
<br />CAUSES POLLUTION OR CONTAMINATION OF THE DOMESTIC WATER SUPPLY. SUCH EQUIPMENT OR
<br />MECHANISM SHALL BE PERMITTED WHERE EQUIPMENT WITH AN APPROVED BACKFLOW PREVENTION
<br />DEVISE OR ASSEMBLY. BACKFLOW PREVENTION DEVICES AND ASSEMBLIES SHALL COMPLY WITH TABLE
<br />603.2, EXCEPT FOR SPECIFIC APPLICATIONS AND PROVISIONS AS STATED IN SECTION 603.5.1 THROUGH
<br />SECTION 603.5.21.
<br />28.EACH PLUMBING FIXTURE THAT CONNECTS TO THE SANITARY SEWER SYSTEM SHALL BE PROPERLY
<br />TRAPPED AND VENTED IN ACCORDANCE WITH THE 2022 CPC.
<br />26.EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES ABOVE THE FLOOD-LEVEL
<br />RIM OF THE FIXTURE SERVED BEFORE OFFSETTING HORIZONTALLY OR BEFORE BEING CONNECTED TO
<br />ANY OTHER VENT.
<br />25.WATER PIPE AND FITTINGS SHALL NOT EXCEED 0.25% LEAD CONTENT IN SYSTEMS CONVEYING POTABLE
<br />WATER.
<br />24.PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH ALL THE REQUIREMENTS IN SECTION 5.303 IN
<br />THE 2022 CALIFORNIA GREEN BUILDING CODE.
<br />23.FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM AND SUBJECT TO
<br />INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR
<br />WATER SEALS.
<br />21.ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE POSSIBLE, AND EXPOSED PIPING SHALL BE
<br />RUN AS HIGH AS POSSIBLE AND TIGHT TO WALLS.
<br />19.ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES, AND SHALL CONFORM TO THE
<br />CALIFORNIA PLUMBING CODE, LATEST EDITION. (2022)
<br />18.PLUMBING CONTRACTOR TO SET IN PLACE ALL OWNER FURNISHED EQUIPMENT ON FIXTURE CONNECTION
<br />SCHEDULE AS DETAILED OR DIRECTED IN FIELD.
<br />16.REFER TO ARCHITECTURAL & KITCHEN DRAWINGS FOR EXACT LOCATION OF ALL FLOOR SINKS, FLOOR
<br />DRAINS, AND WATER REQUIREMENTS.
<br />15.FURNISH AND INSTALL ALL BACKFLOW PROTECTION AS REQUIRED BY STATE AND LOCAL HEALTH DEPT.
<br />AND APPLICABLE CODES.
<br />EXISTING RHEEM
<br />WH-1 4513050-120 1 60 70XG50T12HN38U138 150
<br />EXISTING RHEEM
<br />WH-2 4513050-120 1 60 70XG50T12HN38U138 150 EXISTING TO REMAIN
<br />- SERVICE TO LIKE NEW CONDITION
<br />EXISTING TO REMAIN
<br />- SERVICE TO LIKE NEW CONDITION
<br />(EXIST.)
<br />(EXIST.)
<br />P-5.0 CERTIFICATE OF COMPLIANCE
<br />EMERGENCY EYE WASHEEW
<br />W/ SLOAN #EBF-85 ELECTRONIC BATT. OPERATED FAUCET SET TO MAX. 30 SEC. CYCLE
<br />W/ BDT MIXING VALVE #MIX-135-A, C.P. "P" TRAP, SUPPLY AND DRAIN FITTING, AERATOR
<br />AND MIFAB MC-51-LP CARRIER INSULATE TRAP AND SUPPLY PER CODE MOUNT AS REQ.
<br />EEW EYEWASH STATION - WALL MOUNTED - GUARDIAN G1814 3/4"WALL MOUNTED, STAINLESS STEEL BOWL, 2 SPRAY HEADS2"2"1-1/2"-
<br />2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - KINTERA MANUFACTURING
<br />MODEL KES31818S-218S6 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR.
<br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS.
<br />S1.1 1/2"1/2"2"2"1-1/2"T&S - 5PR-8W08 FAUCET 1.5 GPM AERATOR.
<br />INSTALL P-TRAP AND DIRECT WASTE TO SEWER LINE
<br />SINGLE COMPARTMENT SINK KINTERA KES1C1824S-R18
<br />- OR APPROVED EQUAL
<br />34. THE FLOOR SINK MUST BE EASILY ACCESSIBLE FROM THE WALKWAY WITHOUT HAVING TO CRAWL INTO
<br />TIGHT SPACES, UNDER EQUIPMENT, OR MOVE ANY EQUIPMENT TO REACH IT. THE FLOOR SINK CANNOT BE
<br />IN WALKWAYS OR IN ANY OTHER LOCATION THAT RENDERS IT A TRIPPING HAZZARD.
<br />a. THE TOTAL RUN OF THE DRAIN LINE FROM THE EQUIPMENT TO THE FLOOR SINK CANNOT EXCEED
<br /> (15)-FEET WITH THE EXCEPTION OF WALK-IN UNIT, WHERE THE DRAIN LINE MAY EXCEED THE REQUIRED
<br /> (15)-FEET WHEN ADEQUATEDRAIN SLOPE IS PROVIDED. ALL DRAIN LINES MUST HAVE A MINIMUM (1/4)-INCH
<br /> PER FOOT SLOPE FOR ADEQUATE DRAINAGE, AND BE INSTALLED (1/2)-INCH AWAY FROM WALLS, AND NOT
<br /> CROSS ANY AISLES, TRAFFIC AREAS, OR DOOR OPENINGS. ADDITIONALLY, ALL DRAIN LINES SHALL BE
<br /> INSTALLED (6)-INCHES ABOVE FINISHED FLOOR. MOUNTING HARDWARE USED TO ELEVATE DRAIN LINES
<br /> MUST BE EASILY CLEANABLE. UNISTRUTS, FOR EXAMPLE, ARE NOT CONSIDERED EASILY CLEANABLE AND
<br /> NOT ACCEPTED.
<br />17.PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL SUPPLIES, STOPS, TRAPS, VALVES, SHOCK-STOPS,
<br /> REGULATORS AND BACKFLOW PROTECTION PER CODE TO OWNER'S FURNISHED SINKS AND EQUIPMENT.
<br />35. AN EFFORT SHOULD BE MADE TO ENCLOSE ALL PLUMBING, CONDUIT, AND GAS LINES WITHIN WALLS.
<br /> WHERE THIS IS NOT POSSIBLE, MULTIPE RUNS OR CLUSTERS OF PIPING SHOULD BE FURRED IN, ENCASED
<br /> IN APPROVED RUNWAY OR OTHER APPROVED SEALED ENCLOSURE. ALL CONDUIT, PLUMBING, ETC., NOT
<br /> CONCEALED WITHIN WALLS, MUST BE INSTALLED AT LEAST SIX (6) INCHES OFF THE FLOOR AND 1/2" INCH
<br /> AWAY FROM WALLS. ALL EXPOSED FLEX CONDUIT IS TO BE "SEAL-TIGHT" OR EQUIVALENT. (114257).
<br />FIXTURE
<br />3 COMPARTMENT SINK 24" X 24"
<br />3 COMPARTMENT SINK 18" X 18"
<br />2 COMPARTMENT PREP SINK
<br />1 COMPARTMENT PREP SINK
<br />RESTROOM SINK
<br />DUMP/BAR SINK
<br />JANITOR / MOP SINK
<br />287,980 BTU/H
<br />TOTAL GALLONS PER HOUR CONSUMPTION 440
<br />HAND SINKS
<br />1
<br />4
<br />3
<br />3
<br />25
<br />14
<br />75
<br />168
<br />1
<br />2
<br />2
<br />1
<br />1
<br />11
<br />2
<br />1
<br />1
<br />1
<br />1
<br />1
<br />14
<br />14
<br />6
<br />6
<br />15
<br />6
<br />28
<br />28
<br />12
<br />6
<br />15
<br />66
<br />GPH REQUIREMENTS AS
<br />DETERMINED BY THE
<br />HEALTH DEPARTMENT
<br />AND MANUFACTURERS
<br />DATA SHEETS
<br />QTY
<br />PER
<br />FIXTURE
<br />NUMBER OF
<br />FIXTURES
<br />FIXTURE
<br />TOTALS
<br />SIZING REQUIREMENTS FOR 'NEW'
<br />STORAGE TYPE WATER HEATERS
<br />COLD & HOT WATER HOSE REEL 7 1 6 42
<br />TANK TYPE GAS WATER HEATER SIZING FORMULA - TOTAL GPH X (77) DEGREE RISE IN
<br />WATER REQUIRED X 8.33 LB (WEIGHT OF A GALLON OF WATER) THEN DIVIDED BY THERMAL
<br />EFFICIENCY (0.98% - SEE WATER HEATER SPECS ON SHEET P3.0 = BTU INPUT REQUIRED
<br />TO FURNISH HOT WATER NECESSARY
<br />FIXTURE
<br />3 COMPARTMENT SINK 18" X 18"
<br />1 COMPARTMENT PREP SINK
<br />63,288 BTU/H
<br />TOTAL GALLONS PER HOUR CONSUMPTION 74
<br />HAND SINKS
<br />1 3 14 42
<br />1
<br />2
<br />1
<br />1
<br />14
<br />6
<br />14
<br />6
<br />TANK TYPE GAS WATER HEATER SIZING FORMULA - TOTAL GPH X (77) DEGREE RISE IN
<br />WATER REQUIRED X 8.33 LB (WEIGHT OF A GALLON OF WATER) THEN DIVIDED BY THERMAL
<br />EFFICIENCY AS SET NATIONALLY BY NSF AT .75 OR 75 PERCENT = BTU INPUT REQUIRED TO
<br />FURNISH HOT WATER NECESSARY
<br />GPH REQUIREMENTS AS
<br />DETERMINED BY THE
<br />HEALTH DEPARTMENT
<br />AND MANUFACTURERS
<br />DATA SHEETS
<br />QTY
<br />PER
<br />FIXTURE
<br />NUMBER OF
<br />FIXTURES
<br />FIXTURE
<br />TOTALS
<br />SIZING REQUIREMENTS FOR THE 'EXISTING'
<br />STORAGE TYPE WATER HEATERS
<br />COLD & HOT WATER HOSE REEL 1 1 6 6
<br />2 x 38,000 BTU provided
<br />2 x 150,000 BTU provided
<br />HOLD- 420 W 17th
<br />St3/7/2025
|