23XX <br />26575 Ruether Ave 2nd floor <br />CH <br />A <br />R <br />C <br />Santa Clarita, CA 91350 <br />661.383.2352 - 818.919.2248 <br />YARD BOXY.B.REMOVE/ABANDON <br />ABOVE <br />INDIRECT <br />REDUCED PRESSURE B.F.P. <br />BACKFLOW PREVENTER <br />IND <br />RP <br />ABV. <br />B.F.P. <br />DRAIN <br />GW <br />D <br />PC/SOC <br />D <br />GW <br />PLUG COCK / SHUT-OFF COCK <br />GREASE WASTE <br />NOT IN PLUMBING CONTRACTN.I.P.C. <br />FD or AD FLOOR OR AREA DRAIN <br />PRESSURE REDUCING VALVE <br />POINT OF CONNECTION <br />P.R.V. <br />P.O.C. <br />REQUIRED <br />VENT THRU ROOF <br />RECTANGULAR <br />POLYVINYLCHLORIDE <br />V.T.R. <br />REQ'D <br />RECT. <br />P.V.C. <br />FCO <br />RD OR OD <br />WCO <br />FLOOR CLEANOUT <br />ROOF OR OVERFLOW DRAIN <br />WALL CLEANOUT <br />FLOOR <br />HEATER <br />INVERT ELEVATION <br />GALLONS PER MINUTE <br />FIXTURE UNIT <br />FINISHED FLOOR <br />I.E. <br />G.P.M. <br />HTR. <br />FLR. <br />F.U. <br />FIN. FLR. <br />STORM DRAIN <br />FLOOR SINK <br />CHECK VALVE <br />SD <br />OD <br />FS <br />CWV <br />CV <br />GV/SOV <br />CWV <br />SD <br />OD <br />COMBINATION WASTE AND VENT <br />GATE VALVE / SHUT OFF VALVE <br />OVERFLOW STORM DRAIN <br />BELOWBEL.HW HOT WATER LINE <br />CONNECT <br />CONCRETE <br />CAST IRON <br />CEILING <br />EXISTING <br />DOWN <br />C.I. <br />DN. <br />CLG. <br />EXIST. <br />CONN. <br />CONC. <br />GAS LINE <br />VENT LINEV <br />G <br />HWR <br />CD <br />DOWNSPOUTDS <br />S or W <br />S or W <br />G <br />DS <br />CD <br />SOIL OR WASTE - SUSPENDED <br />SOIL OR WASTE BELOW FLR OR GRADE <br />HOT WATER RETURN <br />CONDENSATE DRAIN <br />DESCRIPTIONABBREV. <br />CW <br />ABBREV.SYMBOL <br />PLUMBING LEGEND <br />DESCRIPTION <br />COLD WATER LINE <br />(E) <br />NEW(N) <br />PIPE SPECIFICATIONS <br />3. CONDENSATE DRAINS... <br />4. WASTE & VENT: <br />GENERAL NOTES <br />1. SLOPE ALL SOIL & WASTE LINES MIN. 2% (¼" PER FT.) <br />7. PLUMBING CONTRACTOR SHALL VERIFY LOCATION OF SITE PIPING AND CABLES BEFORE TRENCHING. <br />11. RECOMPACT ALL PLUMBING EXCAVATION. <br />13. VERIFY SIZE, LOCATION, DEPTH, ETC., OF ALL UTILITIES IN THE FIELD. <br />14. ALL FLOOR SINKS UNDER CASES OR EQUIPMENT SHALL BE HALF EXPOSED. <br />20. NO CLEANOUTS SHALL OCCUR UNDER OR BEHIND ANY CASE OR FIXTURE. <br />22. ALL LINES TO BE LOCATED AWAY FROM BEARING FOOTING, OR AS DIRECTED BY STRUCTURAL ENGINEER. <br />27. ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN APPROVED LISTING AGENCY. <br />29. BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH SECTIONS 701.0 AND 903.0 OF CPC. <br />SERVICE - WATER NOTES <br />1.ALL SERVICE HOT WATER PIPE RUNS GREATER THAN 12'-0" SHALL BE INSULATED <br />ACCORDING TO THE REQUIREMENTS SET IN SECTION 609.11.1 AND 609.11.2 OF <br />THE 2022 CPC. <br />2.PLUMBING FIXTURES SHALL BE CERTIFIED BY THE CALIFORNIA ENERGY <br />COMMISSION. <br /> FIXTURE TOTAL PRESS. (PSIG) MAX FLOW RATE <br /> SINK FAUCETS 20 - 60 1.8 GPM <br /> URINAL 20 - 80 0.125 GPF <br />FILTERED COLD WATERFCWPIPE TEE DOWN <br />PIPE TEE UP <br />PIPE DOWN/FROM BELOW <br />PIPE UP <br />TAG FIXTURE WASTE TRAP VENT COLD <br />WATER WATER <br />HOT REMARKS <br />PLUMBING FIXTURE SCHEDULE <br />TRAP PRIMER - M1FAB M2-500 -1/2"---TP <br />SHEET INDEX <br />SHT.NO.DESCRIPTION <br />P-0.0 PLUMBING GENERAL NOTES, ABBREVIATIONS AND SCHEDULES <br />P-1.0 PLUMBING ADDITIONAL NOTES AND CALCULATIONS <br />P-2.0 <br />PLUMBING FLOOR PLAN - DOMESTIC WATER <br />POINT OF DISCONNECTIONP.O.D. <br />PLUMBING FLOOR PLAN - WASTE & VENT <br />MS 1/2"1/2"2"2" <br />2"2" <br />1-1/2" <br />1-1/2" <br />P-2.2 <br />S2 <br />2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - KINTERA MANUFACTURING <br />MODEL KES3C1818S-218S3 <br />24" X 24" ADVANCE TABCO MODEL 9-OP-4. WITH VACUUM <br />BREAKER SPOUT, 3/4 HOSE THREAD <br />4"INT.2"1-1/2"-WC FLUSH VALVE WATER CLOSET. ADA COMPLIANT <br />BY ARCHITECTS/OWNER <br />L 1-1/2"1/2"2"2"1/2" <br />FS --1-1/2"2"2"INSTALL COMPLETE WITH DOME STRAINER & HALF GRATE. <br />PROVIDE TRAP PRIMER <br />HALF GRATE - 12"W x 12"D x 6"H FLOOR SINK. <br />ZURN Z1910 OR APPROVED EQUAL <br />1/2"1/2"2"2"1-1/2" <br />FD --1-1/2"2"2"IRON ADJUSTABLE TRACTOR GRATE, SEDIMENT BUCKET <br />PROVIDE TRAP PRIMER8" Ø FLOOR DRAIN. WATTS FD-100-A <br />HS GSW - MODEL HS-1615S-N HAND SINK ASSEMBLY <br />OR APPROVED EQUAL 1/2"1/2"2"2"1-1/2" <br />WITH VACUUM BREAKER (AIR-BREAK BACK FLOW) FAUCET <br />SPOUT, 3/4 HOSE THREAD. ZURN Z841M-XL 1.8 GPM <br />T&S - B-2342 FAUCET 1.5 GPM AERATOR. <br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. <br />T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR. <br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. <br />T&S FAUCET MUST HAVE A FLOWRATE OF NO MORE THAN 1.8 GPM. <br />SINK MUST BE PROVIDED WITH WALL BRACKETS. <br />ELECTRONIC TRAP PRIMER - SIOUX CHIEF 695-ES01 -1/2"---TP2 <br />2 COMPARTMENT SINK - BK BKS-2-18-14-18TS <br />OR APPROVED EQUAL <br />WITH SOV & RUN 1/2" TRAP PRIMER LINE TO ALL FLOOR DRAIN <br />AND FLOOR SINK <br />WITH SOV & RUN 1/2" TRAP PRIMER LINE TO ALL FLOOR DRAIN <br />AND FLOOR SINK <br />6" W. TRENCH DRAIN. ZURN Z890 -2"3"3"TD RUN 1/2" TRAP PRIMER LINE TO TRENCH DRAIN P-TRAP <br />P-3.0 PLUMBING DETAILS - WATER HEATER SYSTEM <br />LAVATORY. SHALL BE ADA COMPLIANT BY <br />ARCHITECTS/OWNER <br />P-2.4 PLUMBING ROOF PLAN <br />P-3.1 PLUMBING DETAILS <br />TAG MAKE & MODEL <br />GPH @ 70°F RISE <br />RECOVERY REMARKS <br />PLUMBING EQUIPMENT SCHEDULE <br />MODEL ST-35-CL <br />AMTROL FACTORY PRECHARGED OF 38 PSIET-1 --3.2 <br />-RCP-1 <br />STORAGE <br /> CAP. (GALS.) <br />ELECTRICAL <br />HP V PH HZ <br />WATER TEMP. <br />IN (°F)OUT (°F)WT. (LBS.) <br />SHIPPINGGAS (MBH) <br />INPUT <br />------40 <br />----0.167 HP 120 1 --12 INSTALL PER MANUFACTURER'S INSTALLATION <br />AND OPERATING INSTRUCTIONS <br />AOSMITHWH-3 658140100-120 1 60 70BTH-150 Mxi 150 553 <br />TACO SERIES 0013 <br />PIPE INSULATION SCHEDULE <br />PIPING SERVICE MATERIALS <br />CONDENSATE DRAIN <br />THICKNESS <br />3/4" <br />INSULATION SHALL BE ONE-PIECE PREFORMED GLASS FIBER INSULATION <br />WITH INTEGRAL ALL-PURPOSE FIRE RETARDANT, GLASS YARN SCRIM <br />LAMINATED, WHITE JACKET, “K” FACTOR SHALL BE 0.23 MAXIMUM <br />AT 75 DEGREES F. MEAN TEMPERATURE. <br />INSULATION <br />INSULATION SHALL BE ONE-PIECE PREFORMED GLASS FIBER INSULATION <br />WITH INTEGRAL ALL-PURPOSE FIRE RETARDANT, GLASS YARN SCRIM <br />LAMINATED, WHITE JACKET, “K” FACTOR SHALL BE 0.23 MAXIMUM <br />AT 75 DEGREES F. MEAN TEMPERATURE. <br />DOMESTIC HOT WATER <br />SUPPLY & RETURN <br />SIZE <br />PIPE <br />1"1/2" & 3/4" <br />1-1/2"1" & 1 1/4" <br />3/4" <br />FF FILL FAUCET - FISHER MANUFACTURING POT FILLER HOSE STYLE <br />SINGLE WALL MOUNT 3/4"FAUCET MUST HAVE A FLOWRATE OF NO MORE THAN 1.8 GPM. <br />WHA WATER HAMMER ARRESTOR BY PDI <br />OR APPROVED EQUAL 1"WITH ACCESS PANEL. PROVIDED AS SUGGESTED BY PDI. <br />--- <br />--- <br />- <br />- <br />PLUMBING FLOOR PLAN - GAS & CONDENSATEP-2.3AOSMITHWH-4 658140100-120 1 60 70BTH-150 Mxi 150 553 <br />P-3.2 PLUMBING DETAILS <br />DF DRINKING WATER FOUNTAIN ELKAY EZ0TL8WSSK <br />OR APPROVED EQUAL <br />1/2"SHALL BE MOUNTED AND INSTALLED PER MANUFACTURER'S <br />INSTALLATION AND OPERATING MANUAL---- <br />S1 1/2"1/2"2"2"1-1/2"T&S - 5PR-8W08 FAUCET 1.5 GPM AERATOR. <br />INSTALL P-TRAP AND DIRECT WASTE TO SEWER LINE <br />SINGLE COMPARTMENT SINK KINTERA KES1C1818-L18 <br />- OR APPROVED EQUAL <br />1.WATER.... TYPE "K" SOFT COPPER TUBING BELOW FLOOR OR GRADE. <br /> TYPE "L" HARD DRAWN COPPER TUBING WITH WROUGHT SOLDER JOINT FITTINGS ABOVE FLOOR OR GRADE. <br />2.GAS..........SCHEDULE 40 BLACK STEEL PIPE WITH BLACK MALLEABLE IRON SCREWED FITTINGS. <br /> EXPOSED TO WEATHER SHALL BE GALVANIZED, STEEL PIPE. <br />TYPE "L" HARD DRAWN COPPER TUBING WITH WROUGHT SOLDER JOINT FITTINGS. <br />EMERGENCY EYE WASHEEW <br />2"INT.2"1-1/2"-UR URINAL ADA COMPLIANT BY ARCHITECTS/OWNER <br />WATER HAMMER ARRESTORWHA <br />KOHLER OR APPROVED EQUAL <br />INSTALL AT ADA COMPLIANT - REFER TO ARCH DWGS. PROVIDE 1-1/4" <br />CW SUPPLY ROUGH IN PER CPC 2022 403.3.1 <br />HB1 WALL HYDRANT - ZURN 1305-VB 3/4"WITH VACUUM BREAKER LOSE KEY STOP & LOCK & VANDAL PROOF <br />SCREWS, NICKLE BRONZE, FINISH, INSTALL @+18" <br />HB2 3/4" <br />HB3 3/4" <br />--- <br />--- <br />--- <br />3/4" <br />HB4 3/4"WITH LOOSE KEY STOP AND VACUUM BREAKER---- <br />HB5 3/4"3/4" CW W/ WILKINS (MODEL BFP-8F) VACUUM BREAKER W/ LOOSE <br />KEY STOP AND VANDAL PROOF SCREWS = PROVIDED BY G.C.---- <br />WITH THE VACUUM BREAKER, WALL MOUNTED, LESS DOOR WITH <br />VACUUM BREAKER AND VANDAL PROOF SCREWS <br />- <br />HOT & CW HOSE BIBB - KROWNE ROYAL SERIES MODEL 24-503 <br />WALL HYDRANT - ACORN 8146 <br />WALL HYDRANT - ACORN 8126 <br />WALL HYDRANT - ACORN 8126 <br />INSTALL PER INSTALLATION AND OPERATING MANUAL <br />REMARKS/SPECIFICATIONSSYMBOL <br />CONNECTION <br />H.W.C.W. <br />BFP -- <br />PLUMBING EQUIPMENT SCHEDULE <br />PRV -2" BACKFLOW WATER PREVENTER CAST IRON - <br />INSTALL PER MANUFACTURER'S INSTALLATION <br />AND OPERATING INSTRUCTIONS <br />2" BACKFLOW PREVENTER <br />WILKINS 975XL <br />MANUFACTURER <br />MODEL GPM <br />FLOW <br />PSI <br />LOSS <br />PRESS. <br />LOCATION <br />AT METER <br />RP-2 --INSTALL PER MANUFACTURER'S INSTALLATION <br />AND OPERATING INSTRUCTIONS <br />1-1/4" BACKFLOW PREVENTER <br />WILKINS 975XL2 RPBFP <br />FOR EVAP COND.15 8.0 <br />RP-3 --INSTALL PER MANUFACTURER'S INSTALLATION <br />AND OPERATING INSTRUCTIONS <br />3/4" BACKFLOW PREVENTER <br />WILKINS 909 RP SEE SHEET P-3.11510.0 <br />2" PRESSURE REDUCING <br />VALVE WILKINS 500XL 62 7.0 <br />(FIELD VERIFY) <br />INSTALL PER MANUFACTURER'S INSTALLATION <br />AND OPERATING INSTRUCTIONS <br />REFER TO SHEET P-3.0 <br />INSTALL PER MANUFACTURER'S INSTALLATION <br />AND OPERATING INSTRUCTIONS <br />REFER TO SHEET P-3.0 <br />CO-1 --- <br />CO-2 INSTALL IN WORK AREA FLOORS AND EXTERIOR WALKS WITH <br />EXTRA HEAVY CAST IRON TOP--- <br />CO-3 INSTALL AT ALL TYPE WALL CONSTRUCTION AND FINISHES--- <br />CLEAN OUT - J.R. SMITH 4100 - NB <br />CLEAN OUT - J.R. SMITH 4100 - G <br />CLEAN OUT - J.R. SMITH 4472PC <br />INSTALL IN SALES AREA FLOORS WITH NICKEL-BRONZE TOP- <br />- <br />- <br />2", 3", OR 4" <br />2", 3", OR 4" <br />2", 3", OR 4" <br />SERVICE WEIGHT HUBLESS CAST IRON PIPES AND FITTINGS, WRAPPED WITH 3 MIL. PLASTIC <br />5. SANITARY SEWER: <br />SERVICE WEIGHT HUBLESS CAST IRON PIPES AND FITTINGS, WRAPPED WITH 3 MIL. PLASTIC <br />6. SINK DRAINS: <br />TYPE "DWV" COPPER DRAINAGE TUBE WITH WROT SOLDER JOINT FITTINGS ONLY. (ABS AND PVC PIPING <br />PROHIBITED) <br />7. REFRIGERATION DRAINS: <br />TYPE "M" COPPER DRAINAGE TUBE WITH WROT SOLDER JOINT FITTINGS ONLY. <br />(ABS AND PVC PIPING PROHIBITED) <br />8. SINK DRAIN VALVES: <br />ROTARY WASTE VALVES WITH LEVER / TWIST HANDLES SHALL BE INSTALLED AT ALL 1, 2, <br />AND 3 COMPARTMENT SINKS, ETC. ONLY. MANUAL SINK DRAIN STOPPERS ARE PROHIBITED. <br />P-2.1 <br />PLUMBING DEMO PLAN <br />ELONGATED TOILET, VITREOUS CHINA WITH OPEN SEAT <br />WHITE,1.28 GPF. ADA COMPLIANT <br />MATERIAL AT ALL UNDER GROUND LOCATIONS ONLY <br />- IN ADDITION ABS OR SCHEDULE 40 CPVC PIPING, SHALL BE INSTALLED BELOW SLAB OR GRADE ONLY, <br />APPROVED BY AUTHORITY HAVING JURISDICTION (AJH) <br />MATERIAL AT ALL UNDER GROUND LOCATIONS ONLY <br />- IN ADDITION ABS OR SCHEDULE 40 CPVC PIPING, SHALL BE INSTALLED BELOW SLAB OR GRADE ONLY, <br />APPROVED BY AUTHORITY HAVING JURISDICTION (AJH) <br />2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - BK BKS-3-1824-14-18T <br />OR APPROVED EQUALS4 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR. <br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. <br />2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - JOHN BOOS "3BCS" - 3BCS-184-2D18S5 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR. <br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. <br />3/4" <br />33. ADDITIONAL PIPING NOTES: <br />a. ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED <br /> SYNTHETIC LATEX PAINTS. (CPC 906.1). <br />b. SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT EXCEED THOSE SHOWN IN TABLE 313. <br /> 2022 CPC SEC. 313.3 <br />2.DRAWINGS ARE DIAGRAMATIC. DO NOT SCALE PLUMBING PLANS FOR EXACT HORIZONTAL LOCATION OF <br />PIPE RUNS. <br />3.SUPPLY ROUGH-IN, INSTALL AND CONNECT PLUMBING FIXTURES AS REQUIRED UNLESS OTHERWISE NOTED. <br />4.VERIFY & COORDINATE ROUGH-IN AND FIXTURE LOCATIONS WITH ARCHITECTURAL DWGS. PRIOR TO <br />FABRICATION OR INSTALLATION OF MATERIALS AND AGAIN PRIOR TO SLAB POUR. <br />5.VERIFY ALL ELECTRICAL CHARACTERISTICS WITH ELECTRICAL PLANS PRIOR TO BID OR MATERIAL <br />PURCHASE. <br />6.WORK SHALL NOT BE COVERED UNTIL IT HAS BEEN INSPECTED, TESTED AND APPROVED BY THE <br />PLUMBING INSPECTOR OR OTHER GOVERNMENTAL AUTHORITIES HAVING JURISDICTION. <br />8.PROVIDE ACCESS DOORS TO ALL CONCEALED VALVES. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE <br />NOTED. <br />9.FLUSH VALVES, FAUCETS, STOPS BUBBLERS, ETC., SHALL BE ADJUSTED TO THEIR NORMAL WORKING <br />CONDITIONS. <br />10.ALL LABOR AND MATERIALS SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE OF THE <br />COMPLETED WORK BY THE ARCHITECT, WITH SERVICE, REPLACEMENT OR REPAIR MADE AT NO EXTRA <br />COST TO THE OWNER OR TENANT. <br />12.ALL MATERIALS, EQUIPMENT, INSTALLATION, ETC., SHALL CONFORM TO ALL REQUIREMENTS OF ALL <br />APPLICABLE CITY, COUNTY, STATE AND FEDERAL CODES, ORDINANCES & REGULATIONS. <br />P-4.0 PLUMBING RISER DIAGRAM - DOMESTIC WATER <br />P-4.1 PLUMBING RISER DIAGRAM - WASTE & VENT <br />32.SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED THOSE SHOWN IN TABLE 313.3. <br />2022 CPC SEC. 313.3. <br />31.ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY WATER-BASED SYNTHETIC LATEX <br />PAINTS. (CPC 906.1). <br />30.NO WATER-OPERATED EQUIPMENT OR MECHANISM, OR USE A WATER-TREATING CHEMICAL OR <br />SUBSTANCE, WHERE IT IS FOUND THAT SUCH EQUIPMENT, MECHANISM, CHEMICAL, OR SUBSTANCE <br />CAUSES POLLUTION OR CONTAMINATION OF THE DOMESTIC WATER SUPPLY. SUCH EQUIPMENT OR <br />MECHANISM SHALL BE PERMITTED WHERE EQUIPMENT WITH AN APPROVED BACKFLOW PREVENTION <br />DEVISE OR ASSEMBLY. BACKFLOW PREVENTION DEVICES AND ASSEMBLIES SHALL COMPLY WITH TABLE <br />603.2, EXCEPT FOR SPECIFIC APPLICATIONS AND PROVISIONS AS STATED IN SECTION 603.5.1 THROUGH <br />SECTION 603.5.21. <br />28.EACH PLUMBING FIXTURE THAT CONNECTS TO THE SANITARY SEWER SYSTEM SHALL BE PROPERLY <br />TRAPPED AND VENTED IN ACCORDANCE WITH THE 2022 CPC. <br />26.EACH VENT SHALL RISE VERTICALLY TO A POINT NOT LESS THAN SIX (6) INCHES ABOVE THE FLOOD-LEVEL <br />RIM OF THE FIXTURE SERVED BEFORE OFFSETTING HORIZONTALLY OR BEFORE BEING CONNECTED TO <br />ANY OTHER VENT. <br />25.WATER PIPE AND FITTINGS SHALL NOT EXCEED 0.25% LEAD CONTENT IN SYSTEMS CONVEYING POTABLE <br />WATER. <br />24.PLUMBING FIXTURES AND FITTINGS SHALL COMPLY WITH ALL THE REQUIREMENTS IN SECTION 5.303 IN <br />THE 2022 CALIFORNIA GREEN BUILDING CODE. <br />23.FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE DRAINAGE SYSTEM AND SUBJECT TO <br />INFREQUENT USE SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR <br />WATER SEALS. <br />21.ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE POSSIBLE, AND EXPOSED PIPING SHALL BE <br />RUN AS HIGH AS POSSIBLE AND TIGHT TO WALLS. <br />19.ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND ORDINANCES, AND SHALL CONFORM TO THE <br />CALIFORNIA PLUMBING CODE, LATEST EDITION. (2022) <br />18.PLUMBING CONTRACTOR TO SET IN PLACE ALL OWNER FURNISHED EQUIPMENT ON FIXTURE CONNECTION <br />SCHEDULE AS DETAILED OR DIRECTED IN FIELD. <br />16.REFER TO ARCHITECTURAL & KITCHEN DRAWINGS FOR EXACT LOCATION OF ALL FLOOR SINKS, FLOOR <br />DRAINS, AND WATER REQUIREMENTS. <br />15.FURNISH AND INSTALL ALL BACKFLOW PROTECTION AS REQUIRED BY STATE AND LOCAL HEALTH DEPT. <br />AND APPLICABLE CODES. <br />EXISTING RHEEM <br />WH-1 4513050-120 1 60 70XG50T12HN38U138 150 <br />EXISTING RHEEM <br />WH-2 4513050-120 1 60 70XG50T12HN38U138 150 EXISTING TO REMAIN <br />- SERVICE TO LIKE NEW CONDITION <br />EXISTING TO REMAIN <br />- SERVICE TO LIKE NEW CONDITION <br />(EXIST.) <br />(EXIST.) <br />P-5.0 CERTIFICATE OF COMPLIANCE <br />EMERGENCY EYE WASHEEW <br />W/ SLOAN #EBF-85 ELECTRONIC BATT. OPERATED FAUCET SET TO MAX. 30 SEC. CYCLE <br />W/ BDT MIXING VALVE #MIX-135-A, C.P. "P" TRAP, SUPPLY AND DRAIN FITTING, AERATOR <br />AND MIFAB MC-51-LP CARRIER INSULATE TRAP AND SUPPLY PER CODE MOUNT AS REQ. <br />EEW EYEWASH STATION - WALL MOUNTED - GUARDIAN G1814 3/4"WALL MOUNTED, STAINLESS STEEL BOWL, 2 SPRAY HEADS2"2"1-1/2"- <br />2"2"1-1/2"2"2"1/2"1/2"1-1/2"3-COMPARTMENT SINK - KINTERA MANUFACTURING <br />MODEL KES31818S-218S6 T&S - B-0133-A12-V-BC - FAUCET 1.5 GPM AERATOR. <br />INSTALL P-TRAP AND INDIRECT WASTE DRAIN TO FS. <br />S1.1 1/2"1/2"2"2"1-1/2"T&S - 5PR-8W08 FAUCET 1.5 GPM AERATOR. <br />INSTALL P-TRAP AND DIRECT WASTE TO SEWER LINE <br />SINGLE COMPARTMENT SINK KINTERA KES1C1824S-R18 <br />- OR APPROVED EQUAL <br />34. THE FLOOR SINK MUST BE EASILY ACCESSIBLE FROM THE WALKWAY WITHOUT HAVING TO CRAWL INTO <br />TIGHT SPACES, UNDER EQUIPMENT, OR MOVE ANY EQUIPMENT TO REACH IT. THE FLOOR SINK CANNOT BE <br />IN WALKWAYS OR IN ANY OTHER LOCATION THAT RENDERS IT A TRIPPING HAZZARD. <br />a. THE TOTAL RUN OF THE DRAIN LINE FROM THE EQUIPMENT TO THE FLOOR SINK CANNOT EXCEED <br /> (15)-FEET WITH THE EXCEPTION OF WALK-IN UNIT, WHERE THE DRAIN LINE MAY EXCEED THE REQUIRED <br /> (15)-FEET WHEN ADEQUATEDRAIN SLOPE IS PROVIDED. ALL DRAIN LINES MUST HAVE A MINIMUM (1/4)-INCH <br /> PER FOOT SLOPE FOR ADEQUATE DRAINAGE, AND BE INSTALLED (1/2)-INCH AWAY FROM WALLS, AND NOT <br /> CROSS ANY AISLES, TRAFFIC AREAS, OR DOOR OPENINGS. ADDITIONALLY, ALL DRAIN LINES SHALL BE <br /> INSTALLED (6)-INCHES ABOVE FINISHED FLOOR. MOUNTING HARDWARE USED TO ELEVATE DRAIN LINES <br /> MUST BE EASILY CLEANABLE. UNISTRUTS, FOR EXAMPLE, ARE NOT CONSIDERED EASILY CLEANABLE AND <br /> NOT ACCEPTED. <br />17.PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL SUPPLIES, STOPS, TRAPS, VALVES, SHOCK-STOPS, <br /> REGULATORS AND BACKFLOW PROTECTION PER CODE TO OWNER'S FURNISHED SINKS AND EQUIPMENT. <br />35. AN EFFORT SHOULD BE MADE TO ENCLOSE ALL PLUMBING, CONDUIT, AND GAS LINES WITHIN WALLS. <br /> WHERE THIS IS NOT POSSIBLE, MULTIPE RUNS OR CLUSTERS OF PIPING SHOULD BE FURRED IN, ENCASED <br /> IN APPROVED RUNWAY OR OTHER APPROVED SEALED ENCLOSURE. ALL CONDUIT, PLUMBING, ETC., NOT <br /> CONCEALED WITHIN WALLS, MUST BE INSTALLED AT LEAST SIX (6) INCHES OFF THE FLOOR AND 1/2" INCH <br /> AWAY FROM WALLS. ALL EXPOSED FLEX CONDUIT IS TO BE "SEAL-TIGHT" OR EQUIVALENT. (114257). <br />FIXTURE <br />3 COMPARTMENT SINK 24" X 24" <br />3 COMPARTMENT SINK 18" X 18" <br />2 COMPARTMENT PREP SINK <br />1 COMPARTMENT PREP SINK <br />RESTROOM SINK <br />DUMP/BAR SINK <br />JANITOR / MOP SINK <br />287,980 BTU/H <br />TOTAL GALLONS PER HOUR CONSUMPTION 440 <br />HAND SINKS <br />1 <br />4 <br />3 <br />3 <br />25 <br />14 <br />75 <br />168 <br />1 <br />2 <br />2 <br />1 <br />1 <br />11 <br />2 <br />1 <br />1 <br />1 <br />1 <br />1 <br />14 <br />14 <br />6 <br />6 <br />15 <br />6 <br />28 <br />28 <br />12 <br />6 <br />15 <br />66 <br />GPH REQUIREMENTS AS <br />DETERMINED BY THE <br />HEALTH DEPARTMENT <br />AND MANUFACTURERS <br />DATA SHEETS <br />QTY <br />PER <br />FIXTURE <br />NUMBER OF <br />FIXTURES <br />FIXTURE <br />TOTALS <br />SIZING REQUIREMENTS FOR 'NEW' <br />STORAGE TYPE WATER HEATERS <br />COLD & HOT WATER HOSE REEL 7 1 6 42 <br />TANK TYPE GAS WATER HEATER SIZING FORMULA - TOTAL GPH X (77) DEGREE RISE IN <br />WATER REQUIRED X 8.33 LB (WEIGHT OF A GALLON OF WATER) THEN DIVIDED BY THERMAL <br />EFFICIENCY (0.98% - SEE WATER HEATER SPECS ON SHEET P3.0 = BTU INPUT REQUIRED <br />TO FURNISH HOT WATER NECESSARY <br />FIXTURE <br />3 COMPARTMENT SINK 18" X 18" <br />1 COMPARTMENT PREP SINK <br />63,288 BTU/H <br />TOTAL GALLONS PER HOUR CONSUMPTION 74 <br />HAND SINKS <br />1 3 14 42 <br />1 <br />2 <br />1 <br />1 <br />14 <br />6 <br />14 <br />6 <br />TANK TYPE GAS WATER HEATER SIZING FORMULA - TOTAL GPH X (77) DEGREE RISE IN <br />WATER REQUIRED X 8.33 LB (WEIGHT OF A GALLON OF WATER) THEN DIVIDED BY THERMAL <br />EFFICIENCY AS SET NATIONALLY BY NSF AT .75 OR 75 PERCENT = BTU INPUT REQUIRED TO <br />FURNISH HOT WATER NECESSARY <br />GPH REQUIREMENTS AS <br />DETERMINED BY THE <br />HEALTH DEPARTMENT <br />AND MANUFACTURERS <br />DATA SHEETS <br />QTY <br />PER <br />FIXTURE <br />NUMBER OF <br />FIXTURES <br />FIXTURE <br />TOTALS <br />SIZING REQUIREMENTS FOR THE 'EXISTING' <br />STORAGE TYPE WATER HEATERS <br />COLD & HOT WATER HOSE REEL 1 1 6 6 <br />2 x 38,000 BTU provided <br />2 x 150,000 BTU provided <br />HOLD- 420 W 17th <br />St3/7/2025