Laserfiche WebLink
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />E1.0 <br />DATE: 1/17/2024 <br />11 <br />0 <br />5 <br /> S <br />K <br />A <br />R <br />E <br />N <br /> <br />A <br />V <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br />, <br />92 <br />7 <br />0 <br />4 <br />JO <br />R <br />G <br />E <br /> <br />M <br />A <br />G <br />A <br />L <br />L <br />O <br />N <br /> R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 1/17/2024 00 <br />LEVION CONSTRUCTION LLC <br />2020 IOWA AVE SUITE 103, <br />RIVERSIDE, CA 92507 <br />CONTRACTOR LIC#: #1096696 <br />PHONE #: 951-554-2201 <br />GENERAL B <br />ZACHARY WINGER <br />NOTES <br />NOTES <br />NOTE:- <br />(1) ENCHARGE BATTERY SYSTEM ENERGY CAPACITY SHALL BE SIZED TO <br />SUPPLY ALL DESIRED LOADS DURING AN OUTAGE. POWER CAPACITY OF THE <br />ENCHARGE BATTERY SYSTEM SHALL BE CAPABLE OF SUPPLYING THE <br />LARGEST LOAD ON SITE, PER 2022 CEC 710.15(A) & CEC 710.15(E). <br />(2) ENCHARGE BATTERY STORAGE DISCONNECT SHALL BE SECURED USING <br />AN EATON TYPE-BR CIRCUIT BREAKER HOLD DOWN KIT #BRHDK125 (3) <br />DISTANCE BETWEEN ENPOWER AND ENCHARGE SHOULD BE LESS THEN 5' <br />ELSE AN AC DISCONNECT WILL BE REQUIRED <br />(4) INSTALLER TO VERIFY HOW ENCLOSURE ARE COUPLED TOGETHER VIA <br />CHASE NIPPLE/ CONDUIT <br />1.AFCI PROTECTION IS REQUIRED WHEN LOADS ARE RELOCATED MORE THAN <br />6' [210.12(D)]. <br />2.THE PV BREAKER SHALL BE AT THE FURTHEST POSITION AWAY FROM THE <br />MAIN BREAKER [CEC 705.12(B)(2)(3)(B)]. <br />3.PV BREAKER(S) MAY CONNECT AT EITHER END, BUT NOT BOTH ENDS, OF A <br />CENTER-FED PANEL [CEC 705.12(B)(2)(3)(D)]. <br />4.THE BACK-FED BREAKER SHALL BE SECURED IN PLACE BY AN ADDITIONAL <br />FASTENER PER SECTION [408.36 (D)]. <br />5.VERIFY UFER OR ADD GROUND RODS (MIN. 2) SPACED A MIN. 6' APART (CEC <br />250). <br />6.BOND COLD WATER AND GAS LINES TO GROUNDING ELECTRODE <br />CONDUCTOR PER [CEC 250.105(A)&(B)]. <br />7.PANEL MODIFICATIONS REQUIRE A 3RD/ PARTY FIELD EVALUATION, TO <br />RECERTIFY THE MODIFIED PANEL. THE EVALUATION REPORT IS TO BE <br />GIVEN TO THE INSPECTOR AT TIME OF INSPECTION. IF UNABLE TO <br />RECERTIFY A NEW PANEL WILL BE REQUIRED. <br />1.THIS SYSTEM SHALL COMPLY WITH ALL APPLICABLE CODES (MENTIONED ON PAGE1) INCLUDING:UL STANDARD <br />1741,AND THE MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. <br />2.ALL WORK TO COMPLY WITH CEC <br />3.UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV <br />4.REMOVAL OF A UTILITY-INTERACTIVE MICRO-INVERTER OR OTHER EQUIPMENT SHALL NOT SYSTEM <br />DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV <br />SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR <br />5.ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING <br />6.WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AGENCY AT 25° C; WIRE <br />SHALL BE WET RATED AT 90°C <br />7.EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV TYPE WIRE. <br />8.ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET <br />LOCATIONS <br />9.ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS <br />10.FOR UNGROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH <br />A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS <br />OCCURED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE MICRO-INVERTER TO <br />AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS (CEC 690.35(C)) <br />11.ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS <br />AT BUSBARS WITHIN LISTED EQUIPMENT (CEC 250.64C) <br />12.ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE <br />13.ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE <br />DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS <br />14.FOR GROUNDED SYSTEMS, THE MICRO-INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI <br />FUSE PORT FOR GROUND FAULT INDICATION <br />15.WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ <br />"LINE AND LOAD" <br />16.THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT OF LESS THAN 4 PSF <br />17.THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 45 LBS <br />19.THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL <br />18.AC DISCONNECT IS A "KNIFE BLADE" TYPE DISCONNECT AS THE NEW ELECTRICAL EQUIPMENT WILL BE <br />MAINTAINED <br />20.THE PHOTOVOLTAIC MICRO-INVERTER WILL BE LISTED AS UL 1741 <br />21.SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED COMPLIANT ONTO THE <br />EXISTING DWELLING AS PER THE 2022 CRC. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, <br />OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE <br />REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. <br />THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE <br />REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME; OTHERWISE, THE ALARMS MUST BE HARD <br />WIRED AND INTERCONNECTED. (CRC R314, R315) <br />22.SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTIONS R314 AND 315 TO BE VERIFIED <br />AND INSPECTED BY THE INSPECTOR IN THE FIELD. <br />23.WHEN APPLYING THE 120% RULE OF CEC 705.12(D)(2), THE SOLAR BREAKER TO BE POSITIONED AT THE <br />OPPOSITE END OF THE BUS FROM THE MAIN BREAKER PER 705.12(D)(7) <br />24.PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES - NO <br />BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED OR OBSTRUCTED <br />25.EXISTING UFER. IF THERE IS NO UFER,INSTALL (2) NEW 5/8"X8' GROUND ROD 6' APART.WATER BOND <5' FROM <br />BLDG ENTRANCE. #4 AWG GEC TO BOND GROUND ROD AND WATER PIPE. SPLICES SHALL BE IRREVERSIBLE CRIMPED <br />26.PLAQUES SHALL BE METAL OR PLASTIC, WITH ENGRAVED OR MACHINE PRINTED LETTERS, OR ELECTRO-PHOTO <br />PLATING, IN A CONTRASTING COLOR TO THE PLAQUE-PLACARD IS TWO COLOR/RED FACE-WHITE CORE ENGRAVED <br />PLASTIC. PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS.PLAQUE AT MSP <br />27. THE PV DISCONNECTING MEANS SHALL BE INSTALLED AT A READILY ACCESSIBLE LOCATION EITHER ON THE <br />OUTSIDE OF A BUILDING OR STRUCTURE OR INSIDE NEAREST THE POINT OF ENTRANCE OF THE SYSTEM <br />CONDUCTORS. A SINGLE, VISIBLE-OPEN, LOCKABLE AC DISCONNECT SHALL BE WITHIN THREE FEET OF THE METER <br />ON THE EXTERIOR OF THE BUILDING. <br />1 <br />1105 S Karen Ave <br />8/22/2024