STRUCTURAL STEEL <br />REINFORCED CONCRETE <br />1. <br />2. <br />GENERAL <br />MATERIALS <br />3.CONCRETE AGGREGATES SHALL CONFORM TO CHARTER 4 C.R.C. <br />FOUNDATION <br />C <br />110 MPHWIND SPEED: <br />WIND EXPOSURE: <br />3. <br />LATERAL LOADS:4. <br />TOTAL = 40 PSF <br />LIVE LOAD = 20 PSF <br />DEAD LOAD = 20 PSF <br />ROOF LOAD <br />DESIGN LOADS: <br />SITE CLASS = <br />RISK CATEGORY: <br />TYPICAL FLOOR SHEATHING <br />B.N.:10D COMMON NAILS AT 6" O.C. <br />E.N.:10D COMMON NAILS AT 6" O.C. <br />F.N.:10D COMMON NAILS AT 12" O.C. <br />TYPICAL ROOF SHEATHING DOC PS1 OR DOC PS2. <br />B.N.:8D COMMON NAIL AT 6" O.C. <br />E.N.:8D COMMON NAIL AT 6" O.C. <br />F.N.:8D COMMON NAIL AT 12" O.C. <br />LUMBER GRADES ( U.N.O. ) <br />6X & 8X POSTS/BEAMS/HEADERS: #1 DFL <br />4X POSTS/BEAMS/HEADERS: #2 DFL <br />2X JOISTS/RAFTERS: #2 DFL <br />STUDS: D.F.L. STUD GRADE (UP TO 9'-0"), D.F.L. #2 (HIGHER THAN 9'-0") <br />TOP PLATES & MUD SILLS: D.F.L. CONSTRUCTION GRADE,#2, OR BETTER. <br />5. <br />6. <br />7. <br />Ss: <br />S1: <br />STRENGTH <br />7. <br />9. <br />10.MIN. CONCRETE COVER FOR REINFORCING: <br />A- CONCRETE, PLACED AGAINST EARTH NOT FORMED - 3" <br />B- CONCRETE FORMED OR TROWELED - 2" <br />C- WALLS AND CURBS - 1 1/2" <br />D- SLAB ON GRADE - AT CENTER <br />8. <br />DOWELS SHALL BE EQUAL IN SIZE AND SPACING. <br />4. <br />6. <br />14. <br />15.ALL LEDGERS SHALL BE SPLICED WITH ST22 STRAP, UNLESS NOTED OTHERWISE. <br />16. <br />II <br />D - Stiff <br />1.294 <br />0.462 <br />WOOD <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />10. <br />11. <br />12. <br />13. <br />9. <br />17. <br />18. <br />USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING ADHESIVES MEETING <br />APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN ACCORDANCE WITH MANUFACTURER'S <br />RECOMMENDATIONS. <br />AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE USED: GRABBER <br />PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE QUICK DRIVE SCREWS (ICC-ER-1472), <br />MIN 2" LONG @ 6" O.C. B.S., @ 6" O.C. E.S. AND 12" O.C. F.S. <br />*NOTE: ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE FOLLOWING <br />APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG. <br />15/32" APA RATED SHEATHING EXP 1 (OR OSB) WITH A MIN. PANEL INDEX OF 32/16. <br />REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. <br />ALL STRUCTURAL WOOD SHALL BE OF DOC PS20 DOUGLAS FIR LARCH SPECIES, (19% MAXIMUM MOISTURE <br />CONTENT AT THE TIME OF CONSTRUCTION U.N.O.). <br />ALL MACHINE BOLTS SHALL CONFORM TO ASTM A307. HOLES FOR BOLTS SHOULD BE DRILLED 1/16" LARGER <br />THAN BOLT DIAMETER. <br />FOR NON-SHEAR WALL APPLICATIONS, ROUND WASHERS SHALL BE USED ON ALL BOLTS AND SHOULD <br />CONFORM WITH ANSI/ASME B 18.22.1. USE MIN. 1 3/8" Ø X 7/64" THICK WASHER FOR 1/2" Ø BOLT, 1 3/4" Ø X <br />9/64" THICK WASHER FOR 5/8" Ø BOLT AND 2 1/2" Ø X 11/64" THICK WASHER FOR 1" Ø BOLT. U.N.O. <br />ALL NAILS SHALL BE SINKER NAILS AND STAGGERED U.N.O., EXCEPT AS SHOWN IN NAILING SCHEDULE. <br />ADHESIVE USED TO ATTACH FLOOR SHEATHING TO FRAMING ELEMENTS SHALL CONFORM WITH APA <br />SPECIFICATION AFG-01. <br />MANUFACTURED HARDWARE SPECIFIED ON THE DRAWINGS ARE TO BE SIMPSON STRONG TIE (UNLESS <br />SPECIFICALLY AUTHORIZED IN WRITING BY DESIGNER). FOLLOW ALL MANUFACTURER'S REQUIREMENTS & <br />RECOMMENDATIONS FOR INSTALLATION & HANDLING OF THE PRODUCT. <br />ALL FRAMING, BRACING, NAILING, NOTCHING, DRILLING OR BORING SHALL BE IN ACCORDANCE WITH <br />BUILDING CODE UNLESS MORE STRINGENT REQUIREMENTS ARE SPECIFIED OR REQUIRED BY THE LOCAL <br />JURISDICTION. <br />FABRICATION AND HANDLING OF GLUE-LAM BEAMS SHALL BE PER ANSI/AITC A 190.1 STANDARD BEAMS TO <br />BEAR LEGIBLE APA-ENS OR AITC GRADE STAND. AN APA- EWS CRAN AITC CERTIFICATE OF CONFORMANCE <br />FOR GLUED-LAMINATED MEMBERS SHOULD BE SUBMITTED TO THE FIELD INSPECTOR PRIOR TO <br />INSTALLATION AND GLUE-LAM <br />MEMBERS SHALL BE 24F-V4, DF/DF WITH STANDARD CAMBER (U.N.O.) ALL BEAMS SHALL BE FABRICATED <br />USING WATERPROOF GLUE. <br />STRUCTURAL INFORMATION SHOWN ON FRAMING PLANS IS FOR THE MAIN STRUCTURAL ELEMENTS. <br />NON-STRUCTURAL ELEMENTS SHALL BE CONSTRUCTED PER APPROVED CODE REQUIREMENTS. <br />CONVENTIONAL CONSTRUCTION REQUIREMENTS OF CHAPTER 23 FOR LIGHT FRAMED CONSTRUCTION <br />SHOULD BE FOLLOWED AS REQUIRED. <br />TOP PLATES OF ALL WOOD STUD WALLS TO CONSIST OF (2) 2X'S THE SAME WIDTH AS THE STUDS U.N.O. TOP <br />PLATES SHALL LAP A MINIMUM OF 48" AND BE SPLICED WITH NOT LESS THAN 6-16D NAILS SPACED NOT <br />MORE THAN 12" ON CENTER. <br />ALL SHEAR PANELS SHALL HAVE CONTINUOUS SHEATHING MATERIAL FROM ONE END TO THE OTHER AND <br />FROM PLATE TO PLATE AS SPECIFIED ON THE DRAWINGS. CONTRACTOR SHALL COORDINATE FRAMING <br />SUCH THAT CONTINUITY OF SHEAR PANELS IS ASSURED. <br />ALL SHEAR TRANSFER NAILING SHALL BE PER DRAWINGS, AND CONTRACTOR SHALL PROVIDE PROPER <br />NOTIFICATION FOR INSPECTIONS TO REVIEW THE SAME. <br />PROVIDE POST/MULTIPLE STUDS AT LOWER FLOOR UNDER POST/MULTIPLE STUDS ABOVE. EACH POST/STUD <br />SHALL BE FASTENED BY GYPSUM WALL BOARD W/ 5D COOLER NAILS @ 7" O.C. U.N.O. ON PLAN. PROVIDE <br />FULL WIDTH AND DEPTH COMPRESSION BLOCK BETWEEN FLOORS AT SUCH LOCATIONS. <br />ALL JOIST HANGERS SHALL BE SIMPSON U HANGER, ALL BEAM HANGERS SHALL BE SIMPSON HU HANGERS <br />U.N.O. ON PLAN OR DETAIL. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. <br />ALL REINFORCED CONCRETE MATERIALS AND CONSTRUCTION SHALL CONFORM TO BUILDING CODE, <br />CHAPTER 4. <br />CEMENT SHALL CONFORM TO SECTION CHARTER 4 C.R.C. AND SHALL CORRESPOND TO THAT ON WHICH THE <br />SELECTION OF CONCRETE PROPORTIONS WERE BASED. <br />USE TYPE V CEMENT FOR CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE PER ACI 318-11 TABLE <br />4.3.1 (MIN. F'C=4500 PSI, 28 DAYS SPECIAL INSPECTION IS NOT REQUIRED) VERIFIED WITH SOILS ENGINEER. <br />REFER TO CHAPTER 4 OF THE BUILDING CODE FOR SPECIAL EXPOSURE CONDITIONS AS REQUIRED BY <br />SOILS ENGINEER & SEE CORROSION ENGINEER'S RECOMMENDATIONS FOR CONCRETE EXPOSED TO <br />CORROSIVE ELEMENTS. <br />REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 AND #4 AND GRADE 60 FOR <br />SIZES #5 AND LARGER. <br />CONCRETE (28 DAYS) COMPRESSIVE STRENGTH, F'C, SHALL BE 3000 PSI MIN U.N.O. IN FOUNDATION <br />DETAIL. USE CEMENT TYPE V. <br />SPECIAL INSPECTION IS REQUIRED FOR CONCRETE WITH F'C > 4500 PSI UNLESS SOLELY USED FOR ITEM <br />#4 ABOVE. <br />ALL REINFORCING, DOWELS, HOLDOWNS, AND OTHER INSERTS SHALL BE SECURED IN POSITION AND <br />APPROVED BY THE LOCAL BUILDING OFFICIAL PRIOR TO THE POURING OF ANY CONCRETE. <br />23/32" APA RATED STURD-I-FLOOR T&G EXP I (OR OSB) WITH MIN. SPAN <br />RATING OF 24" O.C. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS <br />OF USE <br />5. <br />SEISMIC DESIGN CATEGORY:D <br />SEISMIC IMPORTANCE FACTOR (I) =1.0 <br />Csy: <br /> Ry: <br />0.111 <br />6.5 <br />BASIC SEISMIC FORCE RESISTING SYSTEM: <br />ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE <br />Csx: <br /> Rx: <br />0.111 <br />6.5 <br />ASTM A-325HIGH-STRENGTH BOLTS <br />STRUCTURAL STEEL SHALL BE DELIVERED TO THE JOB SITE FREE OF RUST, <br />HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A-325, AND BE PROVIDED WITH <br />HARDENED WASHERS CONFORMING TO ASTM F-436. <br />7. <br />6. <br />ALL EXPOSED ENDS OF STEEL MEMBERS SHALL BE CAPPED WITH STEEL PLATE, MIN. 1/4" <br />IN THICKNESS,WITH GROUND SMOOTH WELD, U.N.O. <br />5. <br />4. <br />3. <br />2. <br />EXPANSION BOLTS (RED-HEAD) <br />POWER ACTIVATED FASTENERS <br />SHEAR CONNECTOR STUDS <br />SELF DRILLING ANCHORS <br />HIGH-STRENGTH BOLTS <br />MINIMUM SPACING <br />MINIMUM EDGE DISTANCE <br />ALL OTHER BOLTS <br />BOLT HOLES <br />L.A. RR NO. 22668 <br />W/ 2" DIAM. X 14 GA. DISCS. ICC NO. 1147 <br />0.15 DIAM. X 2-9/16 INCHES <br />ICC NO. 1372 L. A. RR NO. 2748 <br />FRICTION TYPE W/ CLASS A FAYING SURFACE <br />3 BOLT DIAMETERS <br />ICC NO. 1821 <br />AISC TABLE J3.5 <br />ASTM A-307 <br />ALL OTHER SHAPES: <br />BOLTS <br />WIDE FLANGE <br />TUBE <br />PIPE <br />THE AISC SPECIFICATIONS. <br />1. <br />ASTM A-53, TYPE E OR S, GRADE B <br />ASTM A-36 <br />ASTM A-500, GRADE B <br />ASTM A-992 <br />INDIVIDUAL LAMINATIONS SHALL NOT EXCEED 2 INCHES IN NET THICKNESS <br />HEEL CUTS NOT ALLOWED UNLESS DETAILED ON DRAWINGS. <br />PROVIDE STANDARD CAMBER UNLESS NOTED OTHERWISE ON PLAN. <br />FIELD INSPECTOR SHALL BE PROVIDED WITH AN APPROVED "CERTIFICATION OF INSPECTION." <br />GLU-LAM BEAMS SHALL CONFORM TO AND BE MARKED ANSI/AITC STANDARD A190.1 AND <br />CANTILEVER AND OR CONTINUOUS BEAMS SHALL BE COMBINATION 24F-V4, DF/DF. <br />SIMPLE SPAN BEAMS SHALL BE COMBINATION 24F-V4, DF/DF. <br />MOISTURE CONTENT SHALL BE FROM 7% TO 12%.9. <br />5. <br />8. <br />7. <br />6. <br />4. <br />3. <br />2. <br />1. <br />GROUT SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF 1,500 PSI AT 28 DAYS. <br />FOR POURING WITHOUT SEGREGATION OF GROUT CONSTITUENTS. <br />LIME OR LIME PUTTY. SUFFICIENT WATER SHOULD BE ADDED TO PRODUCE A CONSISTENCY <br />CLEANOUTS REQUIRED AT THE BOTTOM OF ALL CELLS CONTAINING VERTICAL <br />CONCRETE MASONRY UNITS SHALL CONFORM TO STANDARD SPECIFICATION FOR HOLLOW <br />SOLID ALL GROUT ALL CELLS UNLESS NOTED OTHERWISE. <br />LOAD BEARING CONCRETE MASONRY UNITS ASTM C 90, GRADE N-11. <br />6. <br />5. <br />REINFORCEMENT FOR POURS EXCEEDING 4 FEET IN HEIGHT. <br />4. <br />3. <br />1. <br />2. <br />1. <br />7. <br />6. <br />DENSITY OF 90% OF THE MAXIMUM OBTAINABLE IN ACCORDANCE WITH ASTM D 1557. <br />ALL COMPACTED FILL SHALL BE PLACED IN AN APPROVED MANNER WITH A MINIMUM <br />COMPACTION REPORTS AND/OR WRITTEN APPROVAL OF COMPACTED FILL FROM A SOIL <br />APPROVED COMPACTED FILL. CONTRACTOR TO PROVIDE BUILDING INSPECTOR WITH <br />ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON FIRM UNDISTURBED NATURAL SOILS OR <br />MADE BY ANY SOILS GEOLOGIST IN THE COURSE OF CONSTRUCTION. <br />THE ENGINEER OF RECORD MUST BE INFORMED OF ANY CHANGES IN DESIGN CRITERIA <br />THEREIN AND MAINTAIN A COPY ON THE JOB SITE AT ALL TIMES. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIREMENTS <br />THE FOUNDATION DESIGN IS BASED UPON CHAPTER 4 C.R.C. <br />GEOLOGIST FOR ANY REQUIRED FILL. <br />5. <br />4. <br />3. <br />2. <br />1. <br />GENERAL REQUIREMENTS <br />IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL GRADES, DIMENSIONS, ELEVATIONS <br />AND CONDITIONS AT THE JOB SITE PRIOR TO BIDDING AND COMMENCING CONSTRUCTION. CROSS <br />CHECK ALL DETAILS AND DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RELATED <br />REQUIREMENTS ON THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND CIVIL DRAWINGS AND <br />NOTIFY THE ENGINEER AND THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO STARTING WORK. <br />EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN IN THE PLANS OR <br />SPECIFICATIONS, ALL PHASES OF WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE <br />REQUIREMENTS OF THE BUILDING CODE, LATEST ADDITION, AS WELL AS ALL APPLICABLE STATE AND <br />LOCAL ORDINANCES AS ADOPTED BY THE CONTROLLING JURISDICTION. <br />2. <br />THE CONTRACT DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE <br />METHOD OF CONSTRUCTION. THE STRUCTURE SHOWN ON THESE DRAWINGS IS STRUCTURALLY <br />SOUND ONLY IN THE COMPLETED FORM. GENERAL CONTRACTOR SHALL PROVIDE ALL MEASURES <br />NECESSARY TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING <br />CONSTRUCTION. SUCH MEASURES INCLUDE, BUT ARE NOT LIMITED TO; BRACING, SHORING FOR <br />CONSTRUCTION EQUIPMENT,AND SHORING FOR THE STRUCTURE. <br />3. <br />TIN NO CASE SHALL DIMENSIONS BE SCALED FROM DRAWINGS AND/OR DETAILS. ANY <br />DISCREPANCIES FOUND WITHIN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION <br />OF THE ARCHITECT AND ENGINEER FOR CLARIFICATION PRIOR TO PROCEEDING. ANY WORK <br />INSTALLED PRIOR TO AND/OR IN CONFLICT WITH SUCH CLARIFICATION SHALL BE CORRECTED BY THE <br />CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER. <br />4. <br />THE PRECISE DIMENSIONS AND LOCATIONS OF ALL DOOR AND WINDOW OPENINGS, INTERIOR AND <br />EXTERIOR WALLS SHALL BE DETERMINED FROM THE ARCHITECTURAL DRAWINGS. OTHER FLOOR, <br />WALL AND ROOF OPENINGS AS REQUIRED FOR MECHANICAL, ELECTRICAL AND/OR SIMILAR <br />REQUIREMENTS SHALL BE VERIFIED FROM SHOP DRAWINGS, EQUIPMENT DATA, ETC. AS REQUIRED. <br />5. <br />6.FLOOR AND WALL OPENINGS, SLEEVES, VARIATIONS IN STRUCTURAL SLAB ELEVATIONS, DEPRESSED <br />AREAS, AND ALL OTHER ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND/OR CIVIL REQUIREMENTS <br />MUST BE COORDINATED BEFORE THE CONTRACTOR PROCEEDS WITH CONSTRUCTION. <br />7.THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION AND COORDINATION WITH <br />ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER DRAWINGS,AND ALL <br />OTHER RELATED DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR THE AND ALL OTHER RELATED <br />DRAWINGS. <br />8.IN ALL CASES WHERE A CONFLICT MAY OCCUR SUCH AS BETWEEN ITEMS INCLUDED IN THE <br />SPECIFICATIONS AND NOTES ON THE DRAWINGS, OR BETWEEN GENERAL NOTES AND SPECIFIC <br />DETAILS, THE ENGINEER SHALL BE NOTIFIED AND HE WILL INTERPRET THE INTENT OF THE CONTRACT <br />DOCUMENTS. <br />ALL MATERIALS SHALL BE FURNISHED AS SHOWN HEREIN UNLESS ALTERNATES ARE APPROVED IN <br />WRITING BY THE ARCHITECT, OWNER AND STRUCTURAL ENGINEER OF RECORD. <br />9. <br />10.ANY REFERENCE TO THE WORDS APPROVED, OR APPROVAL IN THESE DOCUMENTS SHALL BE <br />DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW AND SHALL NOT RELIEVE THE CONTRACTOR <br />AND/OR HIS SUBCONTRACTORS OF ANY LIABILITY IN FURNISHING THE REQUIRED MATERIALS OR <br />LABOR SPECIFICATION. <br />WHERE A DETAIL, SECTION OR NOTE IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR ALL LIKE <br />OR SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. DETAILS MARKED "TYPICAL" SHALL APPLY IN <br />ALL CASES UNLESS SPECIFICALLY INDICATED OTHERWISE. WHERE NO SPECIFIC DETAIL IS SHOWN, <br />THE FRAMING OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO LIKE CASES OF <br />CONSTRUCTION. <br />11. <br />12.CONNECTIONS OF ALL ITEMS SUPPORTED BY THE STRUCTURE ARE THE RESPONSIBILITY OF THE <br />DISCIPLINES WHO MAKE THESE ATTACHMENTS. REVIEW AND COORDINATE ALL THE REQUIREMENTS <br />IN THE ARCHITECTS PROJECT SPECIFICATION AS APPLICABLE. <br />13. <br />VIBRATIONAL EFFECTS OF MECHANICAL AND/OR ANY OTHER EQUIPMENT HAVE NOT BEEN <br />CONSIDERED BY THE STRUCTURAL ENGINEER. <br />IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, <br />WHETHER INDICATED ON THE CONTRACT DRAWING OR NOT, AND TO PROTECT THEM FROM DAMAGE. <br />REPAIR AND REPLACEMENT OF SAID WORK SHALL BE AT THE EXPENSE OF THE CONTRACTOR. <br />14. <br />UNLESS NOTED OTHERWISE, ELEVATIONS SHOWN ON THE STRUCTURAL DRAWINGS ARE TO THE TOP <br />OF BEAMS AND FOUNDATIONS. BEAMS DENOTED AS "DROP" HAVE THE TOP OF BEAM AT THE HEIGHT <br />OF THE TOP PLATE. BEAMS DENOTED AS "FLUSH" HAVE THE BOTTOM OF BEAM AT THE HEIGHT OF <br />THE TOP PLATE, U.N.O. <br />15. <br />DESIGN CRITERIA <br />1.SOILS <br />SOILS ALLOWABLE DESIGN VALUES IS 1500 PSF, <br />BUILDING CODE - 2022 CALIFORNIA BUILDING CODE2. <br />FASTENERS IN CONTACT WITH PRESERVATIVE TREATED LUMBER AND FIRE RETARDANT TREATED WOOD <br />SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR <br />COPPER.EXCEPTION: PLAIN CARBON STEEL FASTENERS IN SBX/DOT AND ZINC BORATE <br />PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED. <br />STUD WALLS PERPENDICULAR TO A CONCRETE OR MASONRY WALL SHALL BE BOLTED TO THE CONCRETE <br />OR MASONRY WALL WITH 5/8" DIAMETER X 8" A307 BOLTS AT TOP, MID-HEIGHT AND BOTTOM. <br />ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE LATEST EDITION OF THE AISC MANUAL OF <br />STEEL CONSTRUCTION AND SHALL BE DETAILED, FABRICATED AND ERECTED IN CONFORMANCE WITH THE <br />AISC SPECIFICATIONS. <br />EXCEPT WHERE ENCASED IN MASONRY, CONCRETE, OR SPRAYED ON FIRE PROOFING, ALL STEEL SHALL <br />RECEIVE ONE COAT OF RUST INHIBITIVE PRIMER. EXPOSED STEEL SHALL BE PROTECTED FROM PHYSICAL <br />DETERIORATION WITH APPROPRIATE COATINGS, GALVINIZING OR OTHER ACCEPTED METHOD. <br />HOLES SHALL NOT BE PLACED IN STEEL MEMBERS UNLESS SPECIFICALLY DETAILED ON DRAWINGS.STEEL <br />MEMBERS SHALL BE SHORED WHEN PERMISSIBLE HOLES ARE CUT OR BURNED. BOLT HOLES SHALL <br />CONFORM TO AISC SPECIFICATION, AND SHALL BE STANDARD HOLES U.N.O. <br />GROUTING OF BASE PLATES SHALL BE WITH NON SHRINK GROUT OR DRYPACKED WITH MINIMUM <br />COMPRESSIVE STRENGTH REQUIRED IN THE CONCRETE SECTION OF THESE NOTES. ALL SURFACES SHALL <br />BE CLEANED OF FOREIGN MATERIAL PRIOR TO GROUTING. <br />MILL SCALE, GREASE, ETC. <br />CONCRETE MASONRY <br />MORTAR SHALL BE FRESHLY PREPARED AND UNIFORMLY MIXED AND COMPOSED OF ONE PART PORTLAND <br />CEMENT, 1/4 TO 1/2 PART LIME PUTTY OR HYDRATED LIME AND DAMP LOOSE SAND EQUAL TO 2-1/4 TO 3 <br />TIMES THE SUM OF THE VOLUME OF CEMENT AND LIME USED. <br />GROUT SHALL BE COMPOSED BY VOLUME OF ONE PART PORTLAND CEMENT, TWO TO THREE PARTS SAND, <br />TWO PARTS PEA GRAVEL TO WHICH MAY BE ADDED NOT MORE THAN 1/10 PART HYDRATED <br />A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR <br />BOLT TO THE PLATE. <br />5. HOLDOWN CONNECTORS BOLTS HOLES SHALL NOT BE MORE THAN 1/16" <br />OVERSIZED AT THE CONNECTOR OF THE HOLD DOWN TO THE POST. <br />6. HOLD DOWN CONNECTORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING <br />THE WALL FRAMING. <br />7. ALL FOUNDATIONS SHALL BEAR UPON LIKE MATERIAL. <br />8. FINAL SOILS / AS-GRADED REPORT WILL BE REQUIRED AT FOUNDATION / SLAB INSPECTION. <br />1. <br />ALL SHEAR HARDWARE AND ANCHOR BOLTS W/ NON-STANDARD SPACING ARE <br />TO BE FIXED IN PLACE FOR THE FOUNDATION INSPECTION. <br />FASTENERS FOR PRESERVATIVE-TREATED SHALL BE NOT DIPPED ZINC-COATED <br />GALVANIZED STEEL, STAINLESS STEEL, SILLICON BRONZE OR COPPER. <br />8. FOOTING WITH MINIMUM REINFORCEMENT OF: 2#4 @ TOP & 2#4 @ BOTTOM. OR U.N.O <br />9. EXISTING FOOTING : USE EPOXY FOR A.B. WITH SAME LENGHT AS REGULAR BOLTS WITH <br />SPECIAL INSPECTION. <br /> MINIMUM 5/8"Ø STEEL BOLTS EMBEDED 7" @ 48" OC INTO THE FOUNDATION WITH MINIMUM 3" S.Q x 0.25" <br />PLATE WASHER FOR THE ANCHOR BOLTS. MINIMUM EDGE DISTANCE 1-7/8" AND WITHIN 12" OF EACH END OF <br />EACH PLATE. <br />2. <br />3. <br />4. <br />ANCHOR BOLTS: <br />ALL FOUNDATION EXCAVATIONS, FILLING, BACK FILLING, AND BUILDING PADS SHALL BE INSPECTED AND <br />APPROVED BY THE CITY BUILDING INSPECTOR BOTH PRIOR TO, AND AFTER PLACEMEMT OF <br />REINFORCEMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SHORING NECESSARY TO SUPPORT <br />CUT AND/OR FILL SECTIONS DURING EXCAVATION AND FOR FORMING AND PLACEMENT OF CONCRETE. <br />THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ENGINEER OF THE LOCATION OF EXISTING UTILITIES <br />AND COMMENCE WORK ONLY AFTER WRITTEN APPROVAL FROM THE ARCHITECT. <br />ALL RETAINING WALLS HAVE BEEN DESIGNED AS A FREE DRAINING CONDITION. DESIGN FOR THE DRAINAGE <br />SYSTEM SHALL BE BY OTHERS AND SHALL MEET THE REQUIREMENTS OF THE SOILS REPORT.BACK FILL <br />AGAINST WALLS SHALL BE PLACED EVENLY AGAINST BOTH SIDES OF WALLS UNTIL THE LOWER GRADE IS <br />REACHED. <br />SHEET INDEX <br />10. THE FOLLOWING BEAMS/HEADERS/RIMS CAN BE FROM ANY MANUFACTURER WITH CURRENT <br /> APPROVED ICC ES - EVALUATION REPORT WITH THE FOLLOWING MECHANICAL PROPERTIES: <br /> FOR "LVL" & "PSL" BEAMS: <br /> Fb = 2900 psi (MIN), Fv = 290 psi (MIN), E = 2.0 x 106 psi (MIN). <br /> FOR "LSL" BEAMS/HEADERS: <br /> Fb = 2325 psi (MIN), Fv = 400 psi (MIN), E = 1.55 x 106 psi (MIN). <br /> FOR MANUFACTURED RIM BOARD WITH MIN 1 1/4" THICK, CONTINUOUSLY SUPPORTED <br /> BY WALL , AND MATCHES JOIST DEPTH: <br /> Fc I (PERPENDICULAR)........ = 680 psi (MIN) <br /> Fc // (PARALLEL)..................... = 1400 psi (MIN) <br /> Ft = 1075 psi (MIN), E = 1.3 x 106 psi (MIN) <br /> GLU-LAM BEAM SHALL BE 24F-V4, DF/DF <br /> Fb = 2400 psi @ BOTTOM, Fb = 1850 psi @ TOP <br /> Fv = 265 psi (MIN), E = 1.8 x 106 psi (MIN). <br />GLU-LAM BEAMS <br />GLUE LAMINATED LUMBER SHALL BE OF A COMBINATION AS ESTABLISHED BY THE AMERICAN <br />INSTITUTE OF TIMBER CONSTRUCTION (AITC), AND FABRICATED BY A LICENSED FABRICATORIN <br />ACCORDANCE WITH AITC 117, AND PRODUCT STANDARDS PS56. <br />APPROVED INSPECTION CERTIFICATES SHALL BE SUBMITTED TO THE BUILDING OFFICIALPRIOR TO <br />ERECTION. THE INSPECTION CERTIFICATES SHALL INCLUDE THE QUALITY CONTROL INSPECTION DATA. <br />Plywood Shear Wall <br />23. <br />24. <br />25. <br />TOTAL LOAD AND LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO MAX. L/240, AND L/360 U.N.O.26. <br />27. <br />29. <br />30. <br />31. <br />A. IDENTITY OF THE COMPANY MANUFACTURING THE TRUSS. <br />B. THE DESIGN LOAD. <br />C. THE SPACING OF THE TRUSSES. <br />CEILING JOISTS <br />32. <br />A. DEAD LOAD = 6.0 PSF <br />B. LIVE LOAD = 10.0 PSF <br />C. TOTAL DEFLECTION = L/240 <br />D. WITH CEILING DRYWALL <br />E. USE #2 DOUGLAS FIR LARCH <br />SIZE <br />2x4 <br />2x6 <br />2x8 <br />12" <br />16" <br />10'-6" <br />9'-7" <br />16'-7" <br />15'-1" <br />21'-11" <br />19'-11" <br />BUILDING CODE CHAPTER 6 C.R.C BALLOON FRAMED WALLS (NON-BEARING) STUD HEIGHTS: <br />- 2X4'S @ 16" O.C. MAXIMUM 14'-0" HEIGHT <br />- 2X6'S @ 16" O.C. MAXIMUM 20'-0" HEIGHT <br />TRUSS MANUFACTURER IS RESPONSIBLE FOR: <br />A. PROVIDING ADDITIONAL SHEAR AND DRAG TRUSSES AS SHOWN ON THE FRAMING PLANS. <br />28. <br />C. MEET THE PROFILE AS INDICATED IN THE DRAWINGS. <br />MAX. SPANSPACING <br />16" <br />12" <br />16" <br />12" <br />21. <br />33. <br />22. <br />19. <br />20. <br />IF A DOUBLE SILL PLATE IS USED AT LIGHT-WEIGHT CONCRETE FLOORING, THEN THE FRAMING <br />CONTRACTOR SHALL APPLY SILL PLATE NAILING TO BOTH SILL PLATES, AT 16" O.C. MAX. OR AS SPECIFIED <br />PER SCHEDULE. <br />- NO MULTIPLES OF 2X4"S ARE ALLOWED TO SPAN MORE THAN 14'-0" BEARING WALLS EXCEEDING 10'-0" <br />MUST BE DESIGNED CASE BY CASE. <br />HEADERS: USE 4X4 FOR OPENINGS LESS THAN 16" AT BEARING WALLS WITHOUT POINT LOADS. FOR <br />NON-BEARING WALLS USE 2X4 FOR OPENINGS UP TO 3'-0" MAX. USE (2)2X4 FOR OPENINGS UP TO 6'-0" MAX. <br />USE 4X6 FOR OPENINGS UP TO 12'-0" MAX. U.N.O. (2-2X ON EDGE CAN BE SUBSTITUTED FOR 4X MEMBERS). <br />APPROVED END-JOINTED LUMBER MAY BE USED INTERCHANGEABLY WITH SOLID SAWN MEMBERS OF THE <br />SAME SPECIES AND GRADE FOR BUILDINGS UP TO 2-STORY. WHEN FINGER JOINTED LUMBER IS MARKED <br />"STUD USE ONLY" OR "VERT USE ONLY" SUCH LUMBER SHALL BE LIMITED TO USE FOR STUDS ONLY. ALL <br />FINGER JOINTED LUMBER SHOULD BEAR A CERTIFIED FINGER JOINTED LUMBER GRADE STAMP. <br />WOOD TRUSS MANUFACTURER SHALL SUPPLY TO THE ENGINEER AND THE BUILDING DEPARTMENT <br />CALCULATIONS AND SHOP DRAWINGS FOR APPROVAL OF DESIGN LOADS, CONFIGURATION (2 OR 3 POINT <br />BEARING), AND SHEAR TRANSFER, PRIOR TO FABRICATION. IT SHALL BE THE RESPONSIBILITY OF THE <br />MANUFACTURER TO OBTAIN BUILDING DEPARTMENT APPROVAL OF CALCULATIONS AND SHOP DRAWINGS <br />PRIOR TO FABRICATION. <br />TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODE FOR ALL LOADS <br />IMPOSED, INCLUDING LATERAL LOADS AND MECHANICAL EQUIPMENT LOADS. <br />ALL CONNECTIONS INVOLVING TRUSSES SHALL BE ICC APPROVED AND OF ADEQUATE STRENGTH TO RESIST <br />STRESSES DUE TO THE LOADINGS INVOLVED AND SHALL BE DESIGNED AND SPECIFIED BY THE TRUSS <br />MANUFACTURER. <br />CROSS BRIDGING AND/OR BRACING SHALL BE PROVIDED AND DETAILED BY TRUSS MANUFACTURER AS <br />REQUIRED TO ADEQUATELY BRACE ALL TRUSSES. <br />TRUSS MANUFACTURER TO PROVIDE DETAILS WHICH ALLOW FOR NORMAL DEFLECTION WITHOUT IMPOSING <br />LATERAL LOADS ON THEIR SUPPORTS (I.E., SCISSORS TRUSSES). <br />B. REVIEWING FRAMING PLANS AND STRUCTURAL DETAILS PRIOR TO FABRICATION OF TRUSSES AND <br />SPECIFYING HANGERS. <br />D. DESIGN TRUSSES FOR DEFLECTION COMPATIBILITY OF THE TRUSS SYSTEM TO AVOID HUMP AND/OR SAG <br />IN ROOF OR CEILING. <br />ALL TRUSSES DESIGNED BY TRUSS MANUFACTURER SHALL BE DESIGNED TO SUSTAIN ALL VERTICAL, <br />LATERAL AND OTHER PERTINENT LOADS, INCLUDING BRACING OF TOP AND BOTTOM CHORDS, IN ADDITION <br />TO ANY CONNECTIONS RELATED TO TRUSSES. CONTRACTOR TO COORDINATE WITH TRUSS <br />MANUFACTURER. <br />ALL TRUSS LUMBER SHALL BE DOUGLAS FIR LARCH (U.N.O.). ROOF TRUSS LUMBER SHALL BE EITHER <br />DOUGLAS FIR LARCH OR HEM-FIR. (U.N.O.) <br />EACH TRUSS SHALL BE LEGIBLY BRANDED, MARKED OR OTHERWISE HAVE PERMANENTLY AFFIXED <br />THERETO THE FOLLOWING INFORMATION LOCATED WITHIN TWO FEET OF THE CENTER OF SPAN ON THE <br />FACE OF THE BOTTOM CHORD: <br />USE THIS SPAN TABLE FOR CEILING JOISTS GIVEN THE FOLLOWING CONDITIONS, UNLESS NOTED <br />OTHERWISE ON PLAN. <br />- SD0 : GENERAL STRUCTURAL NOTES. <br />- S.1 : FOUNDATION & ROOF FRAMING PLAN <br />- SD1 : STRUCTURAL DETAILS. <br />SHEAR WALL NOTES: <br />1.FRAMING AT ADJOINING PANEL EDGES SHALL BE 3 INCHES NOMINAL OR WIDER, AND <br />NAILS SHALL BE STAGGERED WHERE NAILS ARE SPACED 2 INCHES ON CENTER. <br />2.WHERE SHEAR DESIGN VALUES EXCEED 350 PLF., ALL FRAMING MEMBERS RECEIVING <br />EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE 3-INCH NOMINAL <br />MEMBER, OR TWO 2-INCH NOMINAL MEMBERS FASTENED TOGETHER IN ACCORDANCE WITH <br />SECTION 2306.1 TO TRANSFER THE DESIGN SHEAR VALUE BETWEEN FRAMING MEMBERS. <br />WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL <br />CASES. SEE SECTION 2305.3.11 FOR SILL PLATE SIZE AND ANCHORAGE REQUIREMENTS. <br />3.ANCHOR BOLTS FOR SHEAR WALLS SHALL INCLUDE STEEL PLATE WASHERS, A MINIMUM <br />OF 0.229 INCHE BY 3 INCHES BY 3 INCHES IN SIZE, BETWEEN THE SILL PLATE AND NUT. <br />WALL <br />8 Stud to stud (not at braced <br />wall panels) <br />16d common (3 1/2″ × 0.162″)24″ o.c. face nail <br />10d box (3″ × 0.128″); <br />or 3″ × 0.131″ nails 16″ o.c. face nail <br />9 <br />Stud to stud and abutting studs <br />at intersecting wall corners (at <br />braced wall panels) <br />16d box (3 1/2″ × 0.135″); <br />or 3″ × 0.131″ nails <br />12″ o.c. face nail <br />16d common (3 1/2″ × 0.162″)16″ o.c. face nail <br />10 Built-up header (2″ to 2″ header <br />with 1/2″ spacer) <br />16d common (3 1/2″ × 0.162″)16″ o.c. each edge <br />face nail <br />16d box (3 1/2″ × 0.135″)12″ o.c. each edge <br />face nail <br />11 Continuous header to stud <br />5-8d box (2 1/2″ × 0.113″); <br />or 4-8d common (2 1/2″ × 0.131″); <br />or 4-10d box (3″ × 0.128″) <br />Toe nail <br />12 Top plate to top plate <br />16d common (3 1/2″ × 0.162″)16″ o.c. face nail <br />10d box (3″ × 0.128″); <br />or 3″ × 0.131″ nails 12″ o.c. face nail <br />13 <br />Double top plate splice for SDCs <br />A-D2 with seismic braced wall line <br />spacing < 25' <br />8-16d common (3 1/2″ × 0.162″); or <br />12-16d box (3 1/2″ × 0.135″); or 12-10d <br />box (3″ × 0.128″); or 12-3″ × 0.131″ nails <br />Face nail on each <br />side of end joint <br />(minimum 24″ lap <br />splice length each <br />side of end joint)12-16d (3 1/2″ × 0.135″) <br />Double top plate splice SDCs D0, <br />D1, or D2; and braced wall line <br />spacing ≥ 25' <br />14 <br />Bottom plate to joist, rim joist, band <br />joist or blocking (not at braced wall <br />panels) <br />16d common (3 1/2″ × 0.162″)16″ o.c. face nail <br />16d box (3 1/2″ × 0.135″); <br />or 3″ × 0.131″ nails 12″ o.c. face nail <br />15 Bottom plate to joist, rim joist, band <br />joist or blocking (at braced wall <br />panel) <br />3-16d box (3 1/2″ × 0.135″); <br />or 2-16d common (3 1/2″ × 0.162″); <br />or 4-3″ × 0.131″ nails <br />3 each 16″ o.c. face <br />nail 2 each 16″ o.c. <br />face nail 4 each 16″ <br />o.c. face nail <br />16 Top or bottom plate to stud <br />4-8d box (2 1/2″ × 0.113″); or 3-16d box <br />(3 1/2″ × 0.135″); or 4-8d common <br />(2 1/2″ × 0.131″); or 4-10d box (3″ × <br />0.128″); or 4-3″ × 0.131″ nails <br />Toe nail <br />3-16d box (3 1/2″ × 0.135″); or 2-16d <br />common (3 1/2″ × 0.162″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />End nail <br />17 Top plates, laps at corners and <br />intersections <br />3-10d box (3″ × 0.128″); or 2-16d <br />common (3 1/2″ × 0.162″); <br />or 3-3″ × 0.131″ nails <br />Face nail <br />18 1″ brace to each stud and plate <br />3-8d box (2 1/2″ × 0.113″); or 2-8d <br />common (2 1/2″ × 0.131″); or 2-10d box <br />(3″ × 0.128″); or 2 staples 1 3/4″ <br />Face nail <br />19 1″ × 6″ sheathing to each bearing <br />3-8d box (2 1/2″ × 0.113″); or 2-8d <br />common (2 1/2″ × 0.131″); or 2-10d box <br />(3″ × 0.128″); or 2 staples, 1″ crown, <br />16 ga., 1 3/4″ long <br />Face nail <br />20 1″ × 8″ and wider sheathing to each <br />bearing <br />3-8d box (2 1/2″ × 0.113″); or 3-8d <br />common (2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 3 staples, <br />1″ crown, 16 ga., 1 3/4″ long Face nail <br />Wider than 1″ × 8″ 4-8d box (2 1/2″ × <br />0.113″); 3-8d common (2 1/2″ × 0.131″); <br />or 3-10d box (3″ × 0.128″); or 4 staples, <br />1″ crown, 16 ga., 1 3/4″ long <br />FLOOR <br />21 Joist to sill, top plate or girder <br />4-8d box (2 1/2″ × 0.113″); or 3-8d <br />common (2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />Toe nail <br />22 <br />Rim joist, band joist or blocking to <br />sill or top plate (roof applications <br />also) <br />8d box (2 1/2″ × 0.113″)4″ o.c. toe nail <br />8d common (2 1/2″ × 0.131″); <br />or 10d box (3″ × 0.128″); <br />or 3″ × 0.131″ nails <br />6″ o.c. toe nail <br />23 1″ × 6″ subfloor or less to each joist <br />3-8d box (2 1/2″ × 0.113″); or 2-8d <br />common (2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 2 staples, 1″ crown, <br />16 ga., 1 3/4″ long <br />Face nail <br />24 2″ subfloor to joist or girder 3-16d box (3 1/2″ × 0.135″); or 2-16d <br />common (3 1/2″ × 0.162″)Blind and face nail <br />25 2″ planks <br />(plank & beam—floor & roof) <br />3-16d box (3 1/2″ × 0.135″); or 2-16d <br />common (3 1/2″ × 0.162″) <br />At each bearing, <br />face nail <br />26 Band or rim joist to joist <br />3-16d common (3 1/2″ × 0.162″) 4-10 <br />box (3″ × 0.128″), or 4-3″ × 0.131″ nails; <br />or 4-3″ × 14 ga. staples, 7/16″ crown <br />End nail <br />27 Built-up girders and beams, 2-inch <br />lumber layers <br />20d common (4″ × 0.192″); or <br />Nail each layer as <br />follows: 32″ o.c. at top <br />and bottom and <br />staggered. <br />10d box (3″ × 0.128″); <br />or 3″ × 0.131″ nails <br />24″ o.c. face nail at <br />top and bottom <br />staggered on <br />opposite sides <br />And: 2-20d common (4″ × 0.192″); <br />or 3-10d box (3″ × 0.128″); <br />or 3-3″ × 0.131″ nails <br />Face nail at ends and <br />at each splice <br />28 Ledger strip supporting joists or <br />rafters <br />4-16d box (3 1/2″ × 0.135″); or 3-16d <br />common (3 1/2″ × 0.162″); or 4-10d box <br />(3″ × 0.128″); or 4-3″ × 0.131″ nails <br />At each joist or <br />rafter, face nail <br />29 Bridging to joist 2-10d (3″ × 0.128″)Each end, toe nail <br />ITEM DESCRIPTION OF <br />BUILDING ELEMENTS <br />NUMBER AND TYPE <br />OF FASTENER a, b, c <br />SPACING OF <br />FASTENERS <br />Edges <br />(inches)h <br />30 3/8″ – 1/2″ <br />6d common (2″ × 0.113″) nail <br />(subfloor, wall) 8d common <br />(21/2″ × 0.131″) nail (roof) <br />31 19/32″ – 1″8d common nail (21/2″ × 0.131″) <br />11/8″ – 11/4″10d common (3″ × 0.148″) nail; or 8d <br />(21/2″ × 0.131″) deformed nail <br />33 1/2″ structural cellulosic fiberboard <br />sheathing <br />1 1/2″ galvanized roofing nail, 7/16″ <br />head diameter, or 1″ crown staple 16 <br />ga., 1 1/4″ long <br />34 25/32″ structural cellulosic fiberboard <br />sheathing <br />1 3/4″ galvanized roofing nail, 7/16″ <br />head diameter, or 1″ crown staple 16 <br />ga., 1 1/4″ long <br />Intermediate <br />supports c, <br />e (inches) <br />Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing <br />to framing [see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] <br />6 12 <br />6 12 <br />32 6 12 <br />Other wall sheathing <br />3 6 <br />3 6 <br />35 1/2″ gypsum sheathing <br />1 1/2″ galvanized roofing nail; staple <br />galvanized, 1 1/2″ long; 1 1/4″ screws, <br />Type W or S <br />7 7 <br />36 5/8″ gypsum sheathing <br />1 3/4″ galvanized roofing nail; staple <br />galvanized, 1 5/8″ long; 1 5/8″ screws, <br />Type W or S <br />7 7 <br />Wood structural panels, combination subfloor underlayment to framing <br />37 3/4″ and less <br />6d deformed (2″ × 0.120″) nail; or 8d <br />common (2 1/2″ × 0.131″) nail 6 12 <br />38 7/8″ – 1″ <br />8d common (2 1/2″ × 0.131″) nail; or 8d <br />deformed (2 1/2″ × 0.120″) nail 6 12 <br />39 1 1/8″ – 1 1/4″ <br />10d common (3″ × 0.148″) nail; or 8d <br />deformed (2 1/2″ × 0.120″) nail 6 12 <br />d <br />d <br />f <br />f <br />NAILING SCHEDULE: (TABLE R602.3(1) W/ FOOT NOTES 2019 CRC) <br />ITEM DESCRIPTION OF <br />BUILDING ELEMENTS <br />NUMBER AND TYPE <br />OF FASTENERa, b, c <br />SPACING AND <br />LOCATION <br />1 <br />Blocking between ceiling joists <br />or rafters to top plate <br />4-8d box (2 1/2″ × 0.113″) or 3-8d <br />common (2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />Toe nail <br />2 Ceiling joists to top plate <br />4-8d box (2 1/2″ × 0.113″); or 3-8d <br />common 2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />Per joist, toe nail <br />3 <br />Ceiling joist not attached to parallel <br />rafter, laps over partitions [see <br />Sections R802.3.1, R802.3.2 and <br />Table R802.5.1(9)] <br />4-10d box (3″ × 0.128″); or 3-16d <br />common (3 1/2″ × 0.162″); <br />or 4-3″ × 0.131″ nails <br />Face nail <br />4 <br />Ceiling joist attached to parallel rafter <br />(heel joint) [see Sections R802.3.1 <br />and R802.3.2 and Table R802.5.1(9)] <br />Table R802.5.1(9)Face nail <br />5 Collar tie to rafter, face nail or 11/4″ × <br />20 ga. ridge strap to rafter <br />4-10d box (3″ × 0.128″); or 3-10d <br />common (3″ × 0.148″); <br />or 4-3″ × 0.131″ nails <br />Face nail each rafter <br />6 Rafter or roof truss to plate <br />3-16d box nails (3 1/2″ × 0.135″); <br />or 3-10d common nails (3″ × 0.148″); <br />or 4-10d box (3″ × 0.128″); <br />or 4-3″ × 0.131″ nails <br />2 toe nails on one <br />side and 1 toe nail on <br />opposite side of each <br />rafter or truss <br />7 <br />Roof rafters to ridge, valley <br />or hip rafters or roof rafter to <br />minimum 2″ ridge beam <br />4-16d (3 1/2″ × 0.135″); or 3-10d <br />common (3 1/2″ × 0.148″); or 4-10d <br />box (3″ × 0.128″); or 4-3″ × 0.131″ nails <br />Toe nail <br />3-16d box 3 1/2″ × 0.135″); or 2-16d <br />common (3 1/2″ × 0.162″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />End nail <br />ROOF <br />16" O.C. 8" O.C., OR <br /> A35 @ 24" O.C. <br />16" O.C. 4" O.C., OR <br /> A35 @ 12" O.C. <br />A. B. SILL PLATE NAILING <br />(5 8"Ø) (16D SINKER) <br />SHEAR WALL SCHEDULE: <br />TYPE SHEAR PANEL <br /> 1 260 PLF 3/8" APA STRUCT. RATED PLYWOOD(or OSB) <br />WITH 8d COMMON NAILS AT 6" O.C. EDGES <br />AND 12" O.C. FIELD <br /> 2 380 PLF <br /> 3 490 PLF <br />16" O.C. 3" O.C., OR <br /> A35 @ 8" O.C. <br /> 4 640 PLF <br />12" O.C. 2" O.C., OR <br /> A35 @ 6" O.C. <br />3/8" APA STRUCT. RATED PLYWOOD(or OSB) <br />WITH 8d COMMON NAILS AT 4" O.C. EDGES <br />AND 12" O.C. FIELD <br />3/8" APA STRUCT. RATED PLYWOOD(or OSB) <br />WITH 8d COMMON NAILS AT 3" O.C. EDGES <br />AND 12" O.C. FIELD <br />3/8" APA STRUCT. RATED PLYWOOD(or OSB) <br />WITH 8d COMMON NAILS AT 2" O.C. EDGES <br />AND 12" O.C. FIELD <br /> 5 800 PLF <br />8" O.C. (2)3" O.C., OR <br /> A35 @ 6" O.C. <br />15/32" APA STRUCT I. RATED PLYWOOD <br />WITH 10d COMMON NAILS AT 2" O.C. EDGES <br />AND 12" O.C. FIELD <br />STRUCTURAL WOOD <br />- SD2 : STRUCTURAL DETAILS. <br />SOILS REPORT NO. GEO260224SANG, DATE: 03/29/2024 <br />REPORT BY: TMC ENGINEERS INC. ADD : 9542 PACIFIC AVE, ANAHEIM, CA 92804 <br />PHONE: 714-829-5053; EMAIL: Tienchu.pe@gmail.com <br />SDS: <br />SD1: <br />0.863 <br />0.55 <br />GE <br />N <br />E <br />R <br />A <br />L <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br />NO <br />T <br />E <br />S <br />5 <br />4 <br />3 <br />1 <br />2 <br />R E V I S I O N <br />DATE BY <br />11122 BIXLER CIR., <br />BUS: 714-928-2006 <br />EMAIL: TUNGCIVIL2018@GMAIL.COM <br />GARDEN GROVE, CA92840 <br />FAX: 714-901-9535 <br />PROFESSIONAL BUILDING <br />DESIGNS, INC. <br />THIS DRAWING AND DESIGN <br />CONCEPTS ARE PROPRIETARY TO <br />TUNG VO, M.S., P.E. <br />THE DRAWING OR DESIGN <br />CONCEPTS SHALL NOT BE USED <br />OR REPRODUCED IN THE PART <br />OR IN WHOLE WITHOUT THE <br />WRITTEN PERMISSION BY TUNG <br />VO, M.S., P.E. <br />ARCHITECTURAL - STRUCTURAL <br />MECHANICAL - ELECTRICAL - PLUMBING <br />RESIDENTIAL - COMMERCIAL - INDUSTRIAL <br />ON TIME - ON BUDGET - PROFESSIONAL WORK <br />ONE STOP SOLUTION PDC <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />N <br />E <br />W <br /> <br />A <br />D <br />U <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />A <br />d <br />d <br />r <br />e <br />s <br />s <br />: <br /> <br />5 <br />2 <br />2 <br /> <br />S <br /> <br />R <br />o <br />s <br />e <br />w <br />o <br />o <br />d <br /> <br />A <br />v <br />e <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br /> <br />RE <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />SHEET NO.: <br />DRAW BY: <br />DUY NGUYEN <br />PLOTE DATE: <br />JOB NO.: 23026 <br />C 69546 <br />Exp: 06/30/26 <br />TUNG THANH VO <br />C I V I LSTATE OF CALIFORNIA <br />REGISTERED PROFESSIONAL ENGINEER <br />09/29/2023 <br />08/19/2024 BLDG CMNT. <br />SD0 <br />1 <br />1 <br />522 S Rosewood Ave & 1127 <br />W Bishop St <br />4/29/2025