Proposed Electrical Layout <br />Scale: 1/4 " = 1' <br />N <br />Area: 625 Sq Ft. <br />CM <br />CM <br />CM <br />Notes: <br />All sections reference the 2020 National Electrical Code <br />unless otherwise note <br />Require an exterior service disconnect for one- and <br />two-family dwelling units per section 230.85 <br />New services require the installation of a grounding <br />electrode system. The main service panel shall be <br />connected to any and all available grounding electrodes <br />present at the ADU or main dwelling per section 250.50. <br />Overhead service entrance conductors feeding the new <br />panel shall be sized per section 310.15(B)(7) and be <br />protected from physical damage per section 300.4. <br />Main service panels shall be rated appropriately for the <br />environment where they will be installed. Outdoor <br />panelboards need to be rated for wet or damp locations per <br />section 408.37. <br />If installing a subpanel in a detached ADU, a grounding <br />electrode system for the new subpanel will be required. If <br />there are more than six circuits breakers installed in the new <br />subpanel, a main circuit breaker is required per section <br />225.33(A). The minimum rating for the main circuit breaker <br />shall be 60 amperes per section 230.79(D). <br />Per section 210.12(A), AFCI protection is required for all <br />new branch circuits rated 120 volts, 15- or 20-amperes <br />installed in kitchens, family rooms, dining rooms, living <br />rooms, parlors, libraries, dens, bedrooms, sunrooms, <br />recreation rooms, closets, hallways, laundry areas, and <br />similar areas. This includes kitchens, bedrooms, and living <br />rooms, amongst the locations specified. Circuits in these <br />areas that are modified, replaced, or extended shall have <br />AFCI protection as well per section 210.12(B). <br />Per section 210.8(A), GFCI protection is required for all new <br />receptacles rated 120 volts, 15- or 20-amperes installed in <br />bathrooms, garages, outdoors, crawl spaces, unfinished <br />basements, kitchens, within 6 ft. of a sink, bathtub, or <br />shower stall’s outside edge, boathouses, and laundry areas. <br />One receptacle is required at both the front and back of the <br />dwelling per section 210.52(E)(1). These receptacles shall <br />have a weatherproof enclosure, be listed as <br />weather-resistant, and be GFCI protected per sections <br />406.9(B) and 210.8(B)(4) <br />All new lighting installed in residential units is required to be <br />rated as high efficacy as required by section 150.0(k), Table <br />150.0-A. At least one luminaire installed in bathrooms, <br />laundry rooms, and utility rooms shall be controlled by a <br />vacancy sensor per 150.0(k)(2)(J) <br />Provided one laundry circuit (if providing a laundry area), <br />and one bathroom circuit are all required to be installed per <br />sections 210.11(C)(1), (2), and (3). A lighting circuit in <br />habitable rooms and bathrooms is required per section <br />210.70(A)(1). A general receptacle outlet circuit shall be <br />installed per section 210.52(A). <br />Ecobee3 Lite US (V2) <br />Model: EB-STATE3LT-02 <br />00606 <br />Next Gen Builders <br />818-431-5434 <br />nextgenbuildersla.com/ <br />LAND INFORMATION <br /> VICINITY MAP <br />DESIGN STAGE <br />DAVID CRUZ <br />(949) 878-0863 <br />LEGAL DESCRIPTION: <br />LOT 123 <br />N TR 7000 <br />APN #:410-204-13 <br />ZONNING: R1 <br />TRACT:7000 <br />BLOCK:NA <br />CONSTRUCTION TYPE: TYPE V-N <br />AS AT NOTE <br />NOTES <br />GENERAL CONTRACTORS / OWNER SHALL VERIFY SITE, DIMENSIONS, <br />ELEVATIONS, GRADE, SOIL RESTRICTIONS AND ALL FIELD CONDITIONS <br />RELATED TO DESIGN / DRAWINGS OR LOCAL CODES AND REGULA-TIONS, IF <br />ANY DISCREPANCIES ARE FOUND CONTRACTOR / OWNER SHALL <br />INMEDIATELLY NOTIFY THE PARTIES, ARCHITECT, ENGINEER, ETC. <br />SURVEYOR SHALL VERIFY LOT / BUILDING CORNERS, DRAINS. <br />PROPERTY LINE HAS NOT BEEN ESTABLISH BY A SURVEYOR OR <br />AUTHORIZER CIVIL ENGINEER <br />10/07/2021 <br />RICARDO ARAYA <br />ricardo@nextgenbuildersla.com <br />818-431-5434 <br />A10 <br />PROPOSED ADU ELECTRICAL <br />PLAN & ENERGY SEPECIFICATION <br />CONSTRUCTION OF NEW 625 SF ADU <br />AND LEGALIZE 392. SQ.FT. COVERED <br /> PATIO. <br />3522 S TOWNER ST UNIT 2 <br />SANTA ANA, CA 92707 <br />3522 S Towner St - <br />1011156754/4/2024