Laserfiche WebLink
(P)ADU foundation plan <br />Scale: 1/4 " = 1' <br />N <br />Area: 625 Sq Ft. <br />FOOTINGS ON EXPANSIVE SOILS <br />” <br />SIMPSON <br />HOLDOWN <br />ANCHOR DIA.EDGE <br />DISTANCE <br />SDS SCREWS <br />TO POST <br />WASHER <br />HDU2 5 <br />8"3-1/2"6-SDS 1 <br />4" X <br />2-1/2" <br />3" x3"x1 <br />4" <br />5 <br />8" Ø X 10" EMBED. A.B @ 24 " W/3"x3"x0.229" SILL PLATE WASHERS <br />24" SQ. x 24" DEEP WITH 3-#4 REBAR EACH WAYP1 <br />PAD FOOTING SCHEDULE: <br />CF1= 12" WIDE x 24" DEEP CONC. FTG. W/2#4 T&B <br />CF2= EXISTING CONC. FTG. <br />SHEAR WALL SCHEDULE <br />2% Slope <br />CF1CF1 <br />CF1 CF1 <br />CF1 <br />CF1 <br />CF1 CF1 <br />HDU2 <br />LARR <br />25720 <br />HDU2 <br />LARR <br />25720 <br />HDU2 <br />LARR <br />25720 <br />HDU2 <br />LARR <br />25720 <br />2% Slope <br />Scale: 1/4 " = 1' <br />South Elevation (S1) <br />Scale: 1/4 " = 1' <br />8'-6" <br />1'-6" <br />1'-6" <br />min 8" <br />Scale: 1/4 " = 1' <br />North Elevation (N1) <br />Scale: 1/4 " = 1' <br />min 8" <br />Scale: 1/4 " = 1' <br />East Elevation (E1) <br />Scale: 1/4 " = 1' <br />9'-0" <br />min 8" <br />1'-6" <br />1'-6" <br />Scale: 1/4 " = 1' <br />West Elevation (W1) <br />Scale: 1/4 " = 1' <br />9'-0" <br />min 8" <br />max 44"max 44" <br />8'-6" <br />14'-5" <br />5'-3" <br />9'-0"14'-5" <br />4'-9" <br />9'-0" <br />8'-6"8'-6" <br />14'-5" <br />5'-3" <br />9'-0" <br />9'-0" <br />14'-5" <br />4'-9" <br />00606 <br />Next Gen Builders <br />818-431-5434 <br />nextgenbuildersla.com/ <br />LAND INFORMATION <br /> VICINITY MAP <br />DESIGN STAGE <br />DAVID CRUZ <br />(949) 878-0863 <br />LEGAL DESCRIPTION: <br />LOT 123 <br />N TR 7000 <br />APN #:410-204-13 <br />ZONNING: R1 <br />TRACT:7000 <br />BLOCK:NA <br />CONSTRUCTION TYPE: TYPE V-N <br />AS AT NOTE <br />NOTES <br />GENERAL CONTRACTORS / OWNER SHALL VERIFY SITE, DIMENSIONS, <br />ELEVATIONS, GRADE, SOIL RESTRICTIONS AND ALL FIELD CONDITIONS <br />RELATED TO DESIGN / DRAWINGS OR LOCAL CODES AND REGULA-TIONS, IF <br />ANY DISCREPANCIES ARE FOUND CONTRACTOR / OWNER SHALL <br />INMEDIATELLY NOTIFY THE PARTIES, ARCHITECT, ENGINEER, ETC. <br />SURVEYOR SHALL VERIFY LOT / BUILDING CORNERS, DRAINS. <br />PROPERTY LINE HAS NOT BEEN ESTABLISH BY A SURVEYOR OR <br />AUTHORIZER CIVIL ENGINEER <br />10/07/2021 <br />RICARDO ARAYA <br />ricardo@nextgenbuildersla.com <br />818-431-5434 <br />A9 <br />PROPOSED ADU FOUNDATION <br /> PLANS & ELEVATIONS <br />CONSTRUCTION OF NEW 625 SF ADU <br />AND LEGALIZE 392. SQ.FT. COVERED <br /> PATIO. <br />3522 S TOWNER ST UNIT 2 <br />SANTA ANA, CA 92707 <br />3522 S Towner St - <br />1011156754/4/2024