<br />NOTES TO SUBCONTRACTOR:
<br />1. THE GENERAL SUBCONTRACTOR MUST VERIFY ALL DIMENSIONS, CONDITIONS AND ELEVATIONS
<br />BEFORE PROCEEDING WITH THE WORK. ALL DISCREPANCIES SHALL BE RESOLVED BEFORE
<br />PROCEEDING WITH THE WORK. ALL WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER IN
<br />ACCORDANCE WITH ACCEPTED CONSTRUCTION PRACTICES.
<br />2. IT IS THE INTENTION OF THESE DRAWINGS TO SHOW THE COMPLETED INSTALLATION. THE
<br />SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ALL TEMPORARY BRACING, SHORING, TIES, FORM
<br />WORK, ETC. IN ACCORDANCE WITH ALL NATIONAL, STATE, AND LOCAL ORDINANCES, TO SAFELY
<br />EXECUTE ALL WORK AND SHALL BE RESPONSIBLE FOR SAME. ALL WORK SHALL BE IN
<br />ACCORDANCE WITH LOCAL CODES.
<br />3. THE SUBCONTRACTOR SHALL USE ADEQUATE NUMBER OF SKILLED WORKMAN WHO ARE
<br />THOROUGHLY TRAINED AND EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY
<br />FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND METHOD NEEDED FOR PROPER PERFORMANCE
<br />OF THE WORK.
<br />4. SUBCONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
<br />PRACTICES, CONSTRUCTION SUBCONTRACTOR WILL BE REQUIRED TO ASSUME SOLE AND COMPLETE
<br />RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION OF THE
<br />PROJECT, INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, THAT THIS REQUIREMENT SHALL
<br />BE MADE TO APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS AND
<br />SUBCONTRACTOR FURTHER AGREES TO INDEMNIFY AND HOLD DESIGN ENGINEER HARMLESS FROM
<br />ANY AND ALL LIABILITY, REAL OR ALLEGED, IN CONNECTION WITH PERFORMANCE OF WORK ON THIS
<br />PROJECT.
<br />5. SITE GROUNDING SHALL COMPLY WITH AT&T WIRELESS SERVICES TECHNICAL SPECIFICATIONS
<br />FOR FACILITY GROUNDING FOR CELL SITE STANDARDS, LATEST EDITION, AND COMPLY WITH AT&T
<br />TOWERS GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING
<br />CODES ARE MORE STRINGENT THEY SHALL GOVERN.
<br />6. ALL WORK SHALL COMPLY WITH OSHA AND STATE SAFETY REQUIREMENTS. PROCEDURES FOR
<br />THE PROTECTION OF EXCAVATIONS, EXISTING CONSTRUCTION AND UTILITIES SHALL BE
<br />ESTABLISHED PRIOR TO FOUNDATION INSTALLATION.
<br />7. ALL WORK SHALL BE ACCOMPLISHED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL
<br />CODES OR ORDINANCES. THE MOST STRINGENT CODE WILL APPLY IN THE CASE OF
<br />DISCREPANCIES OR DIFFERENCES IN THE CODE REQUIREMENTS.
<br />8. ANY DAMAGE TO THE ADJACENT PROPERTIES WILL BE CORRECTED AT THE SUBCONTRACTOR'S
<br />EXPENSE TO THE SATISFACTION OF THE LANDOWNER AND THE CONSTRUCTION MANAGER.
<br />9. THE COMPLETE BID PACKAGE INCLUDES THESE CONSTRUCTION DRAWINGS ALONG WITH THE
<br />SPECIFICATIONS. SUBCONTRACTOR IS RESPONSIBLE FOR REVIEW OF TOTAL BID PACKAGE PRIOR
<br />TO BID SUBMITTAL.
<br />10. SUBCONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTILITIES WITHIN CONSTRUCTION
<br />LIMITS PRIOR TO CONSTRUCTION.
<br />11. THE SUBCONTRACTOR IS RESPONSIBLE FOR MAINTAINING POSITIVE DRAINAGE ON THE SITE
<br />AT ALL TIMES. SILT AND EROSION CONTROL SHALL BE MAINTAINED ON THE DOWNSTREAM SIDE
<br />OF THE SITE AT ALL TIMES. ANY DAMAGE TO ADJACENT PROPERTIES WILL BE CORRECTED AT THE
<br />SUBCONTRACTOR'S EXPENSE.
<br />12. CLEARING OF TREES AND VEGETATION ON THE SITE SHOULD BE HELD TO A MINIMUM. ONLY
<br />THE TREES NECESSARY FOR CONSTRUCTION OF THE FACILITIES SHALL BE REMOVED. ANY
<br />DAMAGE TO THE PROPERTY OUTSIDE THE LEASED PROPERTY SHALL BE REPAIRED BY THE
<br />SUBCONTRACTOR.
<br />13. ALL SUITABLE BORROW MATERIAL FOR BACK FILL OF THE SITE SHALL BE INCLUDED IN THE BID.
<br />EXCESS TOPSOIL AND UNSUITABLE MATERIAL SHALL BE DISPOSED OF OFF SITE AT LOCATIONS
<br />APPROVED BY GOVERNING AGENCIES PRIOR TO DISPOSAL.
<br />14. PERMITS: THE SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND INCURRING
<br />THE COST OF ALL REQUIRED PERMITS, INSPECTIONS, CERTIFICATES, ETC.
<br />15. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGES, SUBSTITUTIONS BETWEEN
<br />WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT
<br />DRAWINGS WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLETION
<br />OF THE PROJECT.
<br />16. THE PLANS SHOW SOME KNOWN SUBSURFACE STRUCTURES, ABOVE GROUND STRUCTURES
<br />AND/OR EXISTING UTILITIES BELIEVED TO BE IN THE WORKING AREA. IT IS THE RESPONSIBILITY OF
<br />THE SUBCONTRACTOR TO VERIFY ALL UTILITIES, PIPELINES AND OTHER STRUCTURES SHOWN OR
<br />NOT SHOWN ON THESE PLANS. THE SUBCONTRACTOR SHALL CONTACT THE LOCAL
<br />LOCATE SERVICE BEFORE DIGGING OR DRILLING. ANY DAMAGE TO EXISTING
<br />UTILITIES SHALL BE REPAIRED TO THE SATISFACTION OF THE OWNER AND ENGINEER AT THE
<br />SUBCONTRACTOR'S EXPENSE.
<br />GENERAL PROJECT NOTES:
<br />1. THIS PROPOSAL IS FOR THE ADDITION OF A NEW GENERATOR ON A NEW CONCRETE PAD TO AN
<br />EXISTING UNMANNED TELECOMMUNICATIONS FACILITY CONSISTING OF AN EQUIPMENT
<br />SHELTER/PLATFORM AND TOWER.
<br />2. THE PROPOSED FACILITY WILL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR
<br />SEWER SERVICE.
<br />3. THE PROPOSED FACILITY IS UNMANNED AND IS NOT FOR HUMAN HABITAT. (NO HANDICAP
<br />ACCESS IS REQUIRED)
<br />4. OCCUPANCY IS LIMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2
<br />TIMES PER MONTH BY AT&T TECHNICIANS.
<br />5. OUTDOOR STORAGE AND SOLID WASTE CONTAINERS ARE NOT PROPOSED.
<br />6. ALL MATERIAL SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE WITH
<br />THE PROJECT SPECIFICATIONS.
<br />7. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY THE
<br />CONSTRUCTION OPERATION.
<br />8. SUBCONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS AND INSPECTION
<br />REQUIRED FOR CONSTRUCTION.
<br />9. SUBCONTRACTOR SHALL REMOVE ALL TRASH AND DEBRIS FROM THE SITE ON A DAILY BASIS.
<br />ELECTRICAL NOTES:
<br />A. GENERAL
<br />1. COORDINATE LOCATION AND POWER REQUIREMENTS OF ALL EQUIPMENT WITH AT&T AND
<br />EQUIPMENT SUPPLIER PRIOR TO INSTALLATION.
<br />2. COORDINATE LOCATION AND REQUIREMENTS FOR ELECTRICAL AND TELEPHONE SERVICES
<br />WITH THE PROPERTY REPRESENTATIVE, AT&T AND UTILITY COMPANIES. ROUTING OF
<br />CONDUITS MAY BE MODIFIED TO MEET SITE REQUIREMENTS. EXACT CONDUIT ROUTING TO
<br />BE DETERMINED IN THE FIELD.
<br />3. ALL WIRING AND EQUIPMENT SHOWN ON ELECTRICAL SHEETS SHALL BE FURNISHED AND
<br />INSTALLED UNDER ELECTRICAL PORTION OF CONTRACT UNLESS OTHERWISE NOTED
<br />4. UNINTERRUPTED ELECTRICAL SERVICE FOR EXISTING EQUIPMENT SHALL BE MAINTAINED
<br />DURING THE INSTALLATION OF THE WORK DESCRIBED UNDER THESE DOCUMENTS.
<br />TEMPORARY EQUIPMENT, CABLES AND WHATEVER ELSE IS NECESSARY SHALL BE PROVIDED
<br />AS REQUIRED TO MAINTAIN ELECTRICAL SERVICE. TEMPORARY SERVICE FACILITIES, IF
<br />REQUIRED AT ANY TIME, SHALL NOT BE DISCONNECTED OR REMOVED UNTIL NEW SERVICE
<br />EQUIPMENT IS IN PROPER OPERATION. IF ANY SERVICE OR SYSTEM MUST BE INTERRUPTED,
<br />THE CONTRACTOR SHALL REQUEST PERMISSION IN WRITING STATING THE DATE, TIME, ETC.
<br />THE SERVICE WILL BE INTERRUPTED AND THE AREAS AFFECTED. THIS REQUEST SHALL BE
<br />MADE IN SUFFICIENT TIME FOR PROPER ARRANGEMENTS TO BE MADE. WRITTEN
<br />PERMISSION SHALL BE OBTAINED FROM THE OWNER BEFORE INTERRUPTING ELECTRICAL
<br />SERVICE.
<br />5. COORDINATE NEW WORK WITH OTHER TRADES AND VERIFY EXISTING CONDITIONS TO AVOID
<br />INTERFERENCE. IN CASE OF INTERFERENCE, AT&T'S REPRESENTATIVE WILL DECIDE WHICH
<br />WORK IS TO BE RELOCATED, REGARDLESS OF WHICH WAS FIRST INSTALLED.
<br />6. THE INSTALLATION MUST COMPLY WITH NEC AND ALL FEDERAL, STATE AND LOCAL RULES
<br />AND REGULATIONS.
<br />7. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF
<br />SYSTEMS AND EQUIPMENT UNLESS OTHERWISE DEFINED BY DIMENSIONS OR DETAILS.
<br />EXACT EQUIPMENT LOCATIONS AND RACEWAY ROUTING SHALL BE GOVERNED BY ACTUAL
<br />FIELD CONDITIONS AND/OR DIRECTIONS FROM AT&T'S REPRESENTATIVE.
<br />8. CONTRACTOR SHALL PAY ALL PERMITS AND FEES REQUIRED.
<br />9. ALL MATERIALS SHALL BE FURNISHED AND WORK SHALL BE PERFORMED IN ACCORDANCE
<br />WITH THE APPLICABLE SECTIONS OF THE STANDARDS REFERENCED BELOW:
<br /> a. ANSI (AMERICAN NATIONAL STANDARDS INSTITUTE)
<br /> b. ASTIM (AMERICAN SOCIETY FOR TESTING MATERIALS)
<br /> c. ETL (ELECTRICAL TESTING LABORATORY)
<br /> d. ICEA (INSULATED CABLE ENGINEERS ASSOCIATION)
<br /> e. IEEE (INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS)
<br /> f. MBFU (NATIONAL BOARD OF FIRE UNDERWRITERS)
<br /> g. NESC (NATIONAL ELECTRICAL SAFETY CODE)
<br /> h. NEMA (NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION)
<br /> i. NFPA (NATIONAL FIRE PROTECTION ASSOCIATION)
<br /> j. UL (UNDERWRITER'S LABORATORY)
<br /> k. NEC (NATIONAL ELECTRICAL CODE)
<br />10. CONTRACTOR SHALL REVIEW PLANS, DETAILS AND SPECIFICATIONS IN DETAIL AND ADJUST
<br />WORK TO CONFORM WITH ACTUAL SITE CONDITIONS SO THAT ELECTRICAL DEVICES AND
<br />EQUIPMENT WILL BE LOCATED AND READILY ACCESSIBLE. QUANTITIES LISTED IN MATERIAL
<br />LISTS ON THE DRAWINGS ARE FOR INFORMATION ONLY. THE CONTRACTOR SHALL PROVIDE
<br />HIS OWN TAKEOFF FOR MATERIAL QUANTITY AND TYPES BASED ON ACTUAL SITE
<br />CONDITIONS, IN ADDITION, CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS TO
<br />INSTALL EQUIPMENT FURNISHED BY AT&T OR ITS SUPPLIERS. ALL ITEMS NOT SPECIFICALLY
<br />MENTIONED HEREIN OR SHOWN ON THE DRAWINGS, BUT WHICH ARE OBVIOUSLY
<br />NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION, SHALL BE INCLUDED.
<br />11. THE CONTRACTOR OR BIDDER SHALL BEAR THE RESPONSIBILITY OF NOTIFYING (IN WRITING)
<br />AT&T'S REPRESENTATIVE OF ANY CONFLICTS PRIOR TO THE SUBMISSION OF CONTRACTOR'S
<br />PROPOSAL OR PERFORMANCE OF WORK, IN THE EVENT OF DISCREPANCIES THE
<br />CONTRACTOR SHALL PRICE THE MORE COSTLY OR EXTENSIVE WORK, UNLESS DIRECTED IN
<br />WRITING OTHERWISE.
<br />ELECTRICAL NOTES:
<br />12. ALL FLOORS WHERE PENETRATIONS ARE REQUIRED IN BUILDING ARE TO BE CORE DRILLED
<br />AND THEN FIREPROOFED.
<br />B. WIRING/CONDUIT
<br />1. PROVIDE PULL BOXES AND JUNCTION BOXES WHERE SHOWN OR AS REQUIRED BY CODE
<br />SUCH THAT NO MORE THAN THE EQUIVALENT OF FOUR QUARTER BENDS (360 DEGREES
<br />TOTAL) EXIST IN A CONDUIT RUN.
<br />2. ALL POWER AND CONTROL/INDICATION WIRING SHALL BE TYPE THHN/THWN 600V RATED 75
<br />DEGREES CELSIUS, UNLESS NOTED OTHERWISE.
<br />3. CONDUIT BENDS SHALL BE MADE IN ACCORDANCE WITH NEC TABLE 346-10. NO RIGHT
<br />ANGLE DEVICE OTHER THAN STANDARD CONDUIT ELBOWS WITH 12" MINIMUM INSIDE
<br />SWEEPS FOR ALL CONDUITS 2" OR LARGER.
<br />4. POWER WIRING SIZE SHALL NOT BE SMALLER THAN #12 AWG.
<br />5. ALL WIRING SHALL BE COPPER. ALUMINUM WILL NOT BE ACCEPTABLE ALL POWER CIRCUITS
<br />SHALL CONTAIN A GROUND WIRE.
<br />6. PHASE MARKINGS TO BE USED AT POWER CONDUCTOR TERMINATIONS.
<br />7. CONTRACTOR SHALL ENSURE INTEGRITY IS MAINTAINED WHEN INSTALLING CONDUIT AND
<br />WIRING.
<br />8. INSTALL PULL STRING IN ALL CONDUIT.
<br />9. FOR ROOFTOP INSTALLS AND BUILD-OUTS, CONDUITS INSIDE BUILDING AND ON ROOF
<br />SHALL BE RGS, UNLESS OTHERWISE NOTED. FOR RAW LAND SITES AND CO-LOCATES, PVC
<br />SCHEDULE 80 SHALL BE UTILIZED UNLESS NOTED OTHERWISE.
<br />10. MAINTAIN MINIMUM 1'-0" VERTICAL AND 1'-0" HORIZONTAL SEPARATIONS FROM ANY
<br />MECHANICAL GAS PIPING.
<br />11. ALL WIRING ROUTED IN PLENUM TO BE RATED OR IN METALLIC FLEX (LIQUIDTITE) CONDUIT.
<br />C. EQUIPMENT
<br />1. EQUIPMENT/PARTS CONNECTED TO EXISTING PANELS, DUCTS, ETC. SHALL MATCH THE
<br />CHARACTERISTICS (A/C, V, A) OF THAT EQUIPMENT.
<br />2. ALL ELECTRICAL EQUIPMENT OUTSIDE SHALL BE NEMA 3R RATED.
<br />D. GROUNDING
<br />1. ALL GROUND CONNECTIONS TO BUILDING SHALL BE MADE USING TWO-HOLE CONNECTORS.
<br />PROVIDE STAINLESS STEEL BOLTS AND LOCK WASHERS ON ALL MECHANICAL GROUND
<br />CONNECTIONS.
<br />2. ALL EQUIPMENT SURFACES TO BE BONDED TO GROUNDING SYSTEM SHALL BE STRIPPED OF
<br />ALL PAINT AND DIRT AT ANY POINT OF CONNECTION. CONNECTIONS TO VARIOUS METALS SHALL
<br />BE OF A TYPE AS TO PREVENT A GALVANIC OR CORROSIVE REACTION. AREA SHALL BE
<br />REPAINTED FOLLOWING BONDING.
<br />3. ANY METALLIC ITEM WITHIN 6' OF ANY EQUIPMENT OR METALLIC INFRASTRUCTURE (RACKS,
<br />CABLE TRAY.. ETC.) OR GROUND CONDUCTORS MUST BE CONNECTED TO THE
<br />GROUNDING SYSTEM PER AT&T STANDARDS.
<br />4. EXTERIOR, ABOVE GRADE GROUND CONNECTIONS SHALL BE FURNISHED WITH A LIBERAL
<br />PROTECTIVE COATING OF ANTI-OXIDATION COMPOUND.
<br />5. ALL MATERIALS AND LABOR REQUIRED FOR THE GROUNDING SYSTEM AS INDICATED ON THE
<br />PLANS AND DETAILS, AND AS DESCRIBED HEREIN SHALL BE FURNISHED BY THE CONTRACTOR
<br />UNLESS OTHERWISE NOTED.
<br />6. EXACT LOCATION OF GROUND CONNECTION POINTS SHALL BE DETERMINED IN FIELD.
<br />ADJUST LOCATIONS INDICATED ON PLANS ACCORDING TO ACTUAL EQUIPMENT LOCATIONS
<br />TO KEEP THE GROUND CONNECTION CABLES AS SHORT AND STRAIGHT AS PRACTICAL.
<br />7. PROVIDE ALL ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS AS REQUIRED BY THE CURRENT
<br />EDITION OF THE NATIONAL ELECTRIC CODE, THE CURRENT EDITION OF THE NATIONAL
<br />ELECTRICAL SAFETY CODE AND AT&T STANDARDS. BONDING JUMPERS WITH APPROVED GROUND
<br />FITTINGS SHALL BE INSTALLED AT ALL RACEWAYS, EQUIPMENT ENCLOSURES, PULL BOXES, ETC.
<br />TO MAINTAIN GROUND CONTINUITY WHERE REQUIRED BY CODE.
<br />8. ALL BURIED EQUIPMENT GROUND CONDUCTORS SHALL BE #2 AWG BARE, TINNED, SOLID
<br />COPPER UNLESS NOTED OTHERWISE ON THE DRAWINGS.
<br />E. INSPECTION/DOCUMENTATION
<br />1. THE CONTRACTOR, UPON COMPLETION OF HIS WORK, SHALL PROVIDE AS-BUILT DRAWINGS.
<br />INFORMATION SHOULD BE GIVEN TO THE GENERAL CONTRACTOR FOR INCLUSION IN FINAL
<br />AS-BUILT SURVEY DOCUMENTS TO BE GIVEN TO THE OWNER.
<br />2. CONTRACTOR SHALL SUPPLY DOCUMENTATION ATTESTING TO THE COMPLETE GROUND
<br />SYSTEM'S RESISTANCE TO GROUND (MAX. 5 OHMS).
<br />3. AN ELECTRICAL INSPECTION SHALL BE MADE BY AN INSPECTING AGENCY APPROVED BY AT&T'S
<br />REPRESENTATIVE. CONTRACTOR SHALL COORDINATE ALL INSPECTIONS AND OBTAIN
<br />POWER COMPANY APPROVAL.
<br />4. CONTRACTOR SHALL HAVE ATS AND GENERATOR RELAY INSTALLATION AND CONNECTIONS
<br />INSPECTED BY OTHERS TO ENSURE THAT UL LISTING FOR THAT EQUIPMENT IS NOT VOIDED.
<br />230817
<br />REQUIRED SPECIAL INSPECTIONS:
<br />1. PER IBC 1705.4 SPECIAL INSPECTION OF MASONRY. (IF REQUIRED)
<br />CEC
<br />l. CEC (CALIFORNIA ELECTRICAL CODE)CBC
<br />GENERAL NOTES
<br />PO BOX 2621, BOISE, ID 83701
<br />530.539.4787
<br />CONTACT@GEOSTRUCTURAL.COM
<br />WWW.GEOSTRUCTURAL.COM
<br />0 04/01/24 ISSUED FOR CONSTRUCTION BM
<br />SHEET TITLE:
<br />SHEET NUMBER:
<br />N-1
<br />REV DATE DESCRIPTION INT
<br />REVISIONS
<br />SITE INFORMATION:
<br />2621 SOUTH BIRCH STREET
<br />SANTA ANA, CA 92707
<br />GENERATOR INSTALLATION
<br />PROJECT
<br />MAIN - DYER
<br />10086996
<br />CHECKED BY:JAD
<br />THE INFORMATION CONTAINED IN THIS SET OF
<br />DOCUMENTS IS PROPRIETARY BY NATURE. ANY
<br />USE OR DISCLOSURE OTHER THAN THAT WHICH
<br />RELATES TO THE CLIENT NAMES IS STRICTLY
<br />PROHIBITED.
<br />at t &
<br />GENERAL DYNAMICS
<br />Information Technology
<br />09/30/25
<br />JURISDICTION USE:
<br />DATE SIGNED: 4/2/24
<br />2621 S Birch St - 101119515 &
<br />20182981
<br />7/24/2024
|