My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 S Sycamore St Unit# A - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sycamore St
>
3000 S Sycamore St Unit# A
>
3000 S Sycamore St Unit# A - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:37:07 AM
Creation date
6/5/2025 7:36:43 AM
Metadata
Fields
Template:
Plan
Permit Number
20182272
101118488
Full Address
3000 S Sycamore St Unit# A
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(UNLESS BUSBAR IS FULLY RATED) (CEC 705.12) <br />WHITE LETTERS WITH RED BACKGROUND <br />M <br />ARRAY <br />J/B <br />CEC 690.31(G)(3)(4) &CEC 690.13(G)(4) <br />TO BE PLACED AT LEAST EVERY 10FT <br />WHITE LETTERS WITH RED BACKGROUND <br />CEC 690.56 (C)(3) <br />WHITE LETTERS WITH RED BACKGROUND <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />SYSTEM <br />WARNING <br />INVERTER OUTPUT CONNECTION DO NOT <br />RELOCATE THIS OVERCURRENT DEVICE <br />CEC 690.13.G.3 &CEC 690.13.G.4 <br />WHITE LETTERS WITH RED BACKGROUND <br />CEC 690.15, 690.13(B) <br />BLACK TEXT WITH YELLOW BACKGROUND <br />CEC 690.54 <br />WHITE LETTERS WITH RED BACKGROUND <br />CEC 690.17(E) <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES ARE <br />EXPOSED TO SUNLIGHT <br />! <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED AC OPERATING CURRENT 26.10 AMPS <br />AC NOMINAL OPERATING VOLTAGE 240 VOLTS <br />CEC 690.13(B) <br />WHITE LETTERS WITH RED BACKGROUND <br />BLACK OUTLINE WITH BLACK TEXT / WARNING IS IN <br />BLACK TEXT AND ORANGE BACKGROUND <br />AC <br />SUB <br />PANEL <br />CEC 705.12 BLACK LETTERS WITH ORANGE BACKGROUND <br />! <br />CEC 690.56(C)(1)(A) <br />BLACK OUTLINE WITH <br />BLACK TEXT AND <br />WHITE BACKGROUND / <br />NOTE ON TOP IS IN <br />BLACK TEXT AND <br />YELLOW BACKGROUND <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN PV <br />SYSTEM AND REDUCE <br />SHOCK HAZARD IN ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />CAUTION <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECT(S) LOCATED AS SHOWN. <br />DANGEROUS VOLTAGE MAY BE PRESENT AT ALL TIMES <br />I TE SE EMEEY <br />ETI EEY <br />"WARNING" <br />PHOTOVOLTAIC ARRAY <br />DISCONNECTION OF NEUTRAL OR GROUNDED CONDUCTORS MAY RESULT IN <br />OVERVOLTAGE ON ARRAY OR INVERTER. <br />6x8"