My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3000 S Sycamore St Unit# A - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sycamore St
>
3000 S Sycamore St Unit# A
>
3000 S Sycamore St Unit# A - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:37:07 AM
Creation date
6/5/2025 7:36:43 AM
Metadata
Fields
Template:
Plan
Permit Number
20182272
101118488
Full Address
3000 S Sycamore St Unit# A
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MODEL NUMBER <br />ENCHARGE-10-1P-NA Encharge 10 battery storage system with integrated Enphase Microinverters and battery <br />management unit (BMU). Includes: <br />- Three Encharge 3.36 kWh base units (B03-A01-US00-1-3) <br />- One Encharge 10 cover kit with cover, wall mounting bracket, watertight conduit hubs, and <br /> interconnect kit for wiring between batteries (B10-C-1050-O) <br />ACCESSORIES <br />ENCHARGE-HNDL-R1 One set of Encharge base unit installation handles <br />OUTPUT (AC)@ 240 VAC ¹ <br />Rated (continuous) output power 3.84 kVA <br />Peak output power 5.7 kVA (10 seconds) <br />Nominal voltage / range 240 / 211 — 264 VAC <br />Nominal frequency / range 60 / 57 — 61 Hz <br />Rated output current 16 A <br />Peak output current 24.6A (10 seconds) <br />Power factor (adjustable)0.85 leading ... 0.85 lagging <br />Maximum units per 20 A branch circuit 1 unit (single phase) <br />Interconnection Single-phase <br />Maximum AC short circuit fault current over 3 cycles 69.6 Arms <br />Round trip efficiency²89% <br />BATTERY <br />Total capacity 10.5 kWh <br />Usable capacity 10.08 kWh <br />Round trip efficiency 96% <br />Nominal DC voltage 67.2 V <br />Maximum DC voltage 73.5 V <br />Ambient operating temperature range -15º C to 55º C (5º F to 131º F) non-condensing <br />Optimum operating temperature range 0º C to 30º C (32º F to 86º F) <br />Chemistry Lithium iron phosphate (LFP) <br />MECHANICAL DATA <br />Dimensions (WxHxD)1070 mm x 664 mm x 319 mm (42.13 in x 26.14 in x 12.56 in) <br />Weight Three individual 44.2 kg (97.4 lbs) base units plus 21.1 kg (48.7 lbs) cover and mounting <br />bracket; total 154.7 kg (341 lbs) <br />Enclosure Outdoor – NEMA type 3R <br />IQ 8X-BAT microinverter enclosure NEMA type 6 <br />Cooling Natural convection – No fans <br />Altitude Up to 2500 meters (8200 feet) <br />Mounting Wall mount <br />FEATURES AND COMPLIANCE <br />Compatibility Compatible with grid-tied PV systems. Compatible with Enphase M215/M250 and IQ Series <br />Micros, Enphase Enpower, and Enphase IQ Envoy for backup operation. <br />Communication Wireless 2.4 GHz <br />Services Backup, self-consumption, TOU, Demand Charge, NEM Integrity <br />Monitoring Enlighten Manager and MyEnlighten monitoring options; API integration <br />Compliance UL 9540, UN 38.3, UL 9540A, UL 1998, UL 991, NEMA Type 3R, AC156 <br />EMI: 47 CFR, Part 15, Class B, ICES 003 <br />Cell Module: UL 1973, UN 38.3 <br />Inverters: UL 62109-1, IEC 62109-2, UL 1741SA, CAN/CSA C22.2 No. 107.1-16, and IEEE 1547 <br />LIMITED WARRANTY <br />Limited Warranty3 >70% capacity, up to 10 years or 4000 cycles <br />1. Supported in backup/off grid operations <br />2. AC to Battery to AC at 50% power rating. <br />3. Whichever occurs first. Restrictions apply. <br />Enphase Encharge 10 <br />To learn more about Enphase offerings, visit enphase.com <br />© 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Encharge 10, and other trademarks or service names are the trademarks <br />of Enphase Energy, Inc. Data subject to change. 2021-03-01 <br />3000 S Sycamore St Unit# <br />A- 201822724/29/2024
The URL can be used to link to this page
Your browser does not support the video tag.