(E) GARAGE <br />442 SF <br />(E) 1-STORY <br />MAIN UNIT <br />1,348 SF <br />5 BED/2 BATH <br />(E) PORCH <br />138 SF <br />(E) DRIVEWAY <br />AND IMPERVIOUS <br />SURFACE <br />FRONT YARD <br />LANDSCAPING <br />(PER S.A.M.C. SEC. 41-240) <br />(N) CONCRETE <br />WALKWAY <br />PROPERTY LINE - 83.00' <br />PROPERTY LINE - 98.00' <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />- <br /> <br />6 <br />4 <br />. <br />9 <br />4 <br />' <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />- <br /> <br />4 <br />9 <br />. <br />9 <br />4 <br />' <br />(E <br />) <br /> <br />6 <br />' <br />H <br /> <br />B <br />L <br />O <br />C <br />K <br />W <br />A <br />L <br />L <br />15'-0" <br />3:12 <br />12" <br />12" <br />36" <br />6" <br />(E) POWER <br />POLE <br />6' <br />H <br /> <br />M <br />E <br />T <br />A <br />L <br />GA <br />T <br />E <br />6' <br />H <br /> <br />M <br />E <br />T <br />A <br />L <br />GA <br />T <br />E <br />5' <br /> <br />& <br /> <br />6 <br />' <br /> <br />U <br />T <br />I <br />L <br />I <br />T <br />Y <br />EA <br />S <br />E <br />M <br />E <br />N <br />T <br />5'-0" <br />7'-0"17'-8" 25'-4"20'-4" <br />4'-0"8'-0" <br />30'-0" TO <br />CENTERLINE <br />(E) WATER <br />METER <br />14'-6" <br />40'-0" <br />10'-5" <br />30'-0" TO <br />CENTERLINE <br />4'-0" <br />8'-0" <br />7'-0"37'-8" 5'-4" <br />4'-8" <br />19'-0" <br />7'-10" <br />23'-0" <br />℄ <br />℄ <br />W MARK ST <br />S <br />G <br />O <br />L <br />D <br />E <br />N <br /> <br />W <br />E <br />S <br />T <br /> <br />A <br />V <br />E <br />6'-0" <br />(E) 100A PANEL <br />CHANGED TO 100A <br />SUB-PANEL <br />(E) <br />A/C <br />3:12 <br />6" <br />6" <br />6'H METAL <br />GATE <br />5' <br />H <br /> <br />M <br />E <br />T <br />A <br />L <br />GA <br />T <br />E <br />(E) 4'H METAL FENCE <br />O/ 2'H BLOCKWALL <br />10'-5" <br />7'-6" <br />47'-0" <br />(N <br />) <br /> <br />A <br />C <br />(N) ADU <br />749 SF <br />2 BED/2 BATH <br />(N) WATER LINE: 1" <br />COPPER TYPE "L" OR <br />PVC PIPE, MIN. 18" <br />BELOW GROUND <br />(N) PORCH <br />38 SF <br />(N <br />) <br /> <br />M <br />A <br />I <br />N <br /> <br />U <br />N <br />I <br />T <br />10 <br />0 <br />A <br /> <br />P <br />A <br />N <br />E <br />L <br />AD <br />D <br />R <br />E <br />S <br />S <br />NU <br />M <br />B <br />E <br />R <br />(N <br />) <br /> <br />4 <br />" <br /> <br />A <br />B <br />S <br /> <br />S <br />E <br />W <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />, <br />MI <br />N <br />. <br /> <br />2 <br />% <br /> <br />S <br />L <br />O <br />P <br />E <br />(E) 4" SEWER LINE <br />TO STREET (V.I.F.) <br />4:12 <br />12 <br />" <br /> <br />@ <br /> <br />A <br />D <br />U <br />4:1214 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />AND WALL <br />(N <br />) <br /> <br />A <br />D <br />U <br />20 <br />0 <br />A <br /> <br />P <br />A <br />N <br />E <br />L <br />IMAGINARY LINE <br />8'-0" 10'-0" 9'-8" <br />3'-9" <br />36'-3" <br />5'-0" 19'-8"3'-0" <br />4' <br />- <br />0 <br />" <br />2' <br />- <br />0 <br />" <br />(N) 3/4" <br />WATER <br />METER <br />(E <br />) <br /> <br />G <br />A <br />S <br />ME <br />T <br />E <br />R <br />(E) LIGHT <br />POST <br />(E) FIRE <br />HYDRANT <br />ADU PARKING <br />SPACE (20'x10') <br />SO <br />L <br />A <br />R <br /> <br />Z <br />O <br />N <br />E <br /> <br />2 <br />13 <br />0 <br /> <br />S <br />F <br /> <br />( <br />6 <br />. <br />8 <br />' <br />x <br />1 <br />9 <br />' <br />) <br />19'-8" <br />40'-0"(N) ADU <br />749 SF <br />(N) PORCH <br />38 SF <br />SO <br />L <br />A <br />R <br /> <br />Z <br />O <br />N <br />E <br /> <br />1 <br />13 <br />0 <br /> <br />S <br />F <br /> <br />( <br />6 <br />. <br />8 <br />' <br />x <br />1 <br />9 <br />' <br />) <br />3'-0" <br />3'-0" 3'-0" <br />ATTIC VENTILATION CALCULATION <br />TOTAL ATTIC VENTILATION AREA SHALL NOT BE <br />LESS THAN 1/150 OF THE ATTIC SPACE AREA. <br />ADU ATTIC SPACE = 749 + 38 = 787 SF <br />ATTIC VENTS REQUIRED = 787/150 = 5.2 SF <br />===> PROVIDE (6) OHAGINTM 16" DIAMETER ROOF <br />VENTS (1.07 SF EACH), AS INDICATED ON ROOF <br />PLAN HEREON <br />PROJECT INFORMATION <br />OWNER: QK HA FAMILY LIMITED PARTNERSHIP <br />C/O: KIM TRAN - TEL: (714) 856 5977 <br />ADD.: MAIN UNIT: 617 S GOLDEN WEST AVE <br />ADU: 2325 W MARK ST <br />SANTA ANA, CA 92703 <br />(E) MAIN UNIT = 1,348 SF <br />(E) GARAGE = 442 SF <br />(E) PORCH = 138 SF <br />(N) ADU = 749 SF <br />(N) ADU PORCH = 38 SF <br />ADU sf / SFD sf = 749/1,348 = .56 <br />LOT COVERAGE = 1,348+442+138+749+38 = 2,715 SF <br />TOTAL LIVING AREA = 2,097 SF <br />LOT SIZE = 6,370 SF <br />% COVERAGE = 2,715/6,370 = 42.6% <br />APN = 010-301-25 <br />ZONE = R1 <br />OCCUPANCY GROUP = R3/U <br />FLOOD ZONE = X <br />NUMBER OF STORY = 1 <br />TYPE OF CONSTRUCTION = VB <br />(E) UNIT'S FIRE SPRINKLER = NOT EQUIPPED <br />APPLICABLE BUILDING STANDARDS <br />1. 2022 CALIFORNIA MECHANICAL CODE (CMC) <br />2. 2022 CALIFORNIA BUILDING CODE (CBC) <br />3. 2022 CALIFORNIA RESIDENTIAL CODE (CRC) <br />4. 2022 CALIFORNIA PLUMBING CODE (CPC) <br />5. 2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />6. 2022 CALIF. ENERGY EFFICIENCY STANDARD <br />7. 2022 CALIF. GREEN BUILDING STANDARDS <br />8. CITY OF SANTA ANA ORDINANCES <br />DRAWING INDEX <br />A1 SITE/ROOF PLAN - GENERAL NOTES <br />SOLAR ZONE DEDICATION <br />A2 EXISTING AND NEW FLOOR PLAN <br />A3 ELEVATION - SECTION <br />DR1-2 DRAINAGE PLAN <br />SN-1 STRUCTURAL GENERAL NOTES <br />S-1 FOUNDATION PLAN - FRAMING PLAN <br />SD-1 STRUCTURAL DETAILS <br />T1-2 TITLE 24 PLAN <br />T3-4 GREEN BUILDING STANDARDS CODE <br />SCOPE OF WORK <br />1. BUILD NEW DETACHED 749 SF ADU (2 BEDROOM - <br />2 BATHROOM) WITH 38 SF FRONT PORCH <br />2. CHANGE EXISTING UNIT 100A PANEL TO 100A <br />SUB-PANEL AND PLACE NEW 100A PANEL AT ADU <br />3. LEGALIZE THE CHANG-OUT OF VINYL WINDOWS <br />IN EXISTING UNIT <br />CONSTRUCTION NOTES <br />1. CONSTRUCTION WORK HOURS ARE 7AM - 7PM, <br />M-F; 9AM - 7PM, SATURDAY; NO SUNDAY OR LEGAL <br />HOLIDAYS. <br />2. THERE SHALL BE NO TRENCHES OR <br />EXCAVATIONS 5' OR MORE IN DEPTH INTO WHICH A <br />PERSON IS REQUIRED TO DESCEND, OR OBTAIN <br />PERMIT FROM STATE OF CA, DIVISION OF <br />OCCUPATIONAL SAFETY AND HEALTH (CAL/OSHA). <br />THIS PERMIT AND ANY OTHER SAFETY PERMIT <br />SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY <br />WORK. <br />VICINITY MAP <br />ADU PARKING EXEMPTION NOTE <br />PROPOSED ADU IS LOCATED MORE THAN <br />ONE-HALF MILE TO OCTA ROUTE 47 ALONG <br />S FAIRVIEW ST. AT WILLITS ST., AN ADU <br />PARKING STALL IS PROVIDED, AS INDICATED <br />IN SITE PLAN HEREON. <br />GENERAL NOTES <br />1. ALL WORK PERFORMED SHALL COMPLY WITH THESE GENERAL NOTES (UNLESS NOTED OTHERWISE ON THESE PLANS AND <br />SPECIFICATIONS) AND ALL THE FOLLOWING NOTES, DRAWINGS AND SPECIFICATIONS. GENERAL CONTRACTOR SHALL COORDINATE <br />THE INTENT OF GENERAL NOTES WITH MECHANICAL, ELECTRICAL, AND PLUMBING TRADES. <br />2. THE GENERAL CONTRACTOR OBTAINS AND PAYS FOR ALL REQUIRED PERMITS AND ARRANGES FOR ALL REQUIRED <br />INSPECTIONS. <br />3. ALL WORK SHALL COMPLY WITH LATEST EDITION OF BUILDING CODES AS ADOPTED BY THE CITY OF SANTA ANA AND ALL OTHER <br />APPLICABLE REGULATIONS. <br />4. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL SITES CONDITIONS, DIMENSIONS AND ELEVATION BEFORE <br />STARTING THE WORK, AND NOTIFY THE DESIGNER OF ANY DISCREPANCY, IN WRITING, PRIOR TO PROCEEDING. <br />5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND <br />TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES OF REPAIR OR REPLACEMENT IN CONJUNCTION <br />WITH THE PROSECUTION OF SUCH WORK. <br />6. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF THE UTILITY SERVICES IN THE AREA TO BE EXCAVATED PRIOR TO THE <br />EXCAVATION. <br />7. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM <br />BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITE <br />OR BY THE CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM <br />DRAIN SYSTEM. <br />8. ALL NEW ROOF MATERIALS, STUCCO AND WINDOWS SHALL MATCH EXISTING COLOR AND STYLE. <br />EMERGENCY EGRESS NOTES <br />1. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. <br />2. MIN. 5 SQUARE FEET FOR GRADE-FLOOR OPENINGS <br />3. MIN. SET CLEAR HEIGHT OF 24 INCHES. <br />4. WINDOW TO BOTTOM OF CLEAR OPENING SHALL BE NO MORE THAN 44 INCHES. <br />STUCCO NOTES <br />1. A CORROSION RESISTANT WEEP SCREED 2" BELOW PLATE, 6" (2" FOR CONCRETE WALKWAY) ABOVE GRADE THAT ALLOWS <br />TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING IS REQUIRED BELOW THE STUCCO AT THE FOUNDATION PLATE <br />LINE. <br />2. 7/8" MIN. THICK THREE-COAT APPLICATION (SCRATCH, BROWN AND FINISH) OVER SELF-FURRING GALVANIZED WIRE LATH OVER <br />GRADE D BUILDING PAPER AND WIRE BACKING. <br />3. EXTERIOR LATH: PROVIDE 2 LAYERS OF GRADE D PAPER OVER SHEATHING OR WOOD STUDS <br />SETBACK AND PROPERTY LINE NOTE <br />THE OWNER/CONTRACTOR SHALL CONSULT WITH A LAND SURVEYOR TO DETERMINE IF A LOT/BOUNDARY SURVEY IS NEEDED TO <br />VERIFY SETBACKS OF EXISTING AND PROPOSED STRUCTURES WITH RESPECT TO PROPERTY LINES. IN THE EVENT THERE IS <br />DISCREPANCY BETWEEN PROPOSAL AND FIELD MEASUREMENTS OF SETBACK, THE DESIGNER SHALL BE NOTIFIED; AND REVISION <br />SHALL BE SUBMITTED FOR CITY APPROVAL. <br />FRONT YARD NOTES <br />1. FRONT YARD LANDSCAPING SHALL COMPLY WITH <br />S.A.M.C. SEC. 41-240. <br />2. LANDSCAPING AREAS SHALL BE DESIGNED WITH <br />AN AUTOMATIC IRRIGATION SYSTEM WITH POP-UP <br />SPRINKLERS. DRIP, BUBBLER OR OTHER LOW <br />GALLONAGE SYSTEMS MAY BE USED IN BUFFER <br />AREAS AND NARROW STRIPS. <br />3. FRONT YARD LANDSCAPING, IF NOT PRESENT, <br />SHALL BE RESTORED WITH LIVE VEGETATION <br />(GRASS OR ACCEPTABLE DRY CLIMATE GROUND <br />COVER). <br />4.FENCE IN FRONT YARD SHALL COMPLY WITH <br />S.A.M.C. SEC. 41-610 AND SHALL NOT EXCEED 3' IN <br />HEIGHT. <br />ELECTRICAL METER RELOCATION NOTE <br />THE CONTRACTOR SHALL CONTACT SOUTHERN <br />CALIFORNIA EDISON (SCE) @ 800-655-4555 TO <br />OBTAIN A NEW METER SPOT APPROVAL AND <br />INSTALLATION INSTRUCTIONS PRIOR TO <br />INSTALLING THE NEW METER SERVICE PANEL. <br />LOCATION AND AMPERAGE OF NEW METER IN THIS <br />PLAN ARE ONLY PROPOSAL AND SUBJECT TO SCE <br />FINAL APPROVAL. <br />PHOTOVOLTAIC SYSTEM NOTE <br />1. A MINIMUM 2.03 KWdc PHOTOVOLTAIC <br />SYSTEM (PER TITLE 24) SHALL BE <br />INSTALLED ON THE ADU PRIOR TO FINAL <br />INSPECTION SIGN-OFF. THE PV SYSTEM <br />SHALL BE SUBMITTED UNDER A SEPARATE <br />SUBMITTAL. <br />2. SOLAR PERMIT ISSUANCE IS REQUIRED <br />PRIOR TO PERFORMING FRAMING <br />INSPECTION. <br />SITE/ROOF PLAN <br />SCALE: 1/8" = 1'-0" <br />SI <br />T <br />E <br /> <br />P <br />L <br />A <br />N <br />RO <br />O <br />F <br /> <br />P <br />L <br />A <br />N <br />GE <br />N <br />E <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br /> <br />SO <br />L <br />A <br />R <br /> <br />Z <br />O <br />N <br />E <br /> <br />DE <br />D <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br /> <br />OW <br />N <br />E <br />R <br />QK <br /> <br />H <br />A <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />L <br />I <br />M <br />I <br />T <br />E <br />D <br /> <br />P <br />A <br />R <br />T <br />N <br />E <br />R <br />S <br />H <br />I <br />P <br />TE <br />L <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />8 <br />5 <br />6 <br /> <br />5 <br />9 <br />7 <br />7 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />MA <br />I <br />N <br /> <br />U <br />N <br />I <br />T <br />: <br /> <br />6 <br />1 <br />7 <br /> <br />S <br /> <br />G <br />O <br />L <br />D <br />E <br />N <br /> <br />W <br />E <br />S <br />T <br /> <br />A <br />V <br />E <br />AD <br />U <br />: <br /> <br />2 <br />3 <br />2 <br />5 <br /> <br />W <br /> <br />M <br />A <br />R <br />K <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />DATE 11/25/2023 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />7 <br />4 <br />9 <br /> <br />S <br />F <br /> <br />A <br />D <br />U <br /> <br />(2 <br /> <br />B <br />E <br />D <br />R <br />O <br />O <br />M <br /> <br />- <br /> <br />2 <br /> <br />B <br />A <br />T <br />H <br />R <br />O <br />O <br />M <br />) <br />SHEET <br />A1 <br />REVISION <br />DATE BY <br />1 <br />2 <br />3 <br />PROJECT ENGINEER <br />BEN PHAN <br />10822 WOODWARD LN <br />GARDEN GROVE, CA 92840 <br />TEL: (714) 251 4537 <br />LANDSCAPING LEGEND <br />GRASS OR ACCEPTABLE DRY <br />CLIMATE GROUND COVER <br />POP-UP SPRINKLER <br />NEW 5 GAL. JUNIPER BUSH (TYP. 7) <br />NEW 1 GAL. ENCORE AZALEA (TYP. 16) <br />FRUIT TREES ( VARIETY - MAX. 20' APART) <br />NEW 24" BOX KING PALM OR SIMILAR, <br />TREE SHALL BE DOUBLE-STAKED <br />DIG ALERT (811) SHALL BE CONTACTED AND <br />COMPLIANCE WITH EXCAVATION SAFETY IN <br />ACCORDANCE WITH GOVERNMENT CODE 4216 <br />SHALL BE FOLLOWED PRIOR TO ANY <br />EXCAVATION TAKING PLACE <br />SOLAR ZONE DEDICATION <br />SCALE: 3/16" = 1'-0" <br />PLANNING NOTE <br />THE APPLICANT/PROPERTY OWNER SHALL <br />BE RESPONSIBLE FOR CONFIRMING ALL <br />EXISTING UTILITY EASEMENTS AND OR <br />CLEARANCE ON-SITE THAT MAY AFFECT <br />THE PROJECT. <br />BUILDING NOTE <br />THE ADU SF / SFD SF RATIO IS FOR PARK & RECREATION <br />FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE <br />FOR THE GIVEN "SFR SF" OF THE EXISTING PRIMARY <br />RESIDENCE; BUILDING SAFETY STAFF ARE NOT <br />RESPONSIBLE FOR THE ACCURACY OF THE GIVEN "SFR <br />SF". <br />Bldg# 101118551 <br /> <br />APPROVALS: <br />PLNG - PRaj <br />BLDG - CSG Consultants <br />POLICE - BMartin <br />2325 W Mark St - <br />1011185516/17/2024