Laserfiche WebLink
$ <br />S-A <br />DINING AREA BEDROOM 1 <br />17'-2"12'-0" <br />6'-3" <br />5'-4" <br />12'-1" <br />BA <br />T <br />H <br /> <br />1 <br />45'-3" <br />BEDROOM 2 <br />BATH 2 <br />3" <br />11'-11" <br />1'-4" <br />1'-10" <br />STACKED <br />W/D <br />WH <br />LIVING AREA <br />30" <br />1,024 SI <br />1'-4" <br />1'-11" <br />8'-11" <br />18'-2" <br />9'-3" <br />10'-9"2'-0"11'-1" <br />4'-6" <br />4'-7"7'-6" <br />4'-0"3'-0" <br />ATTIC <br />ACCESS <br />30" x 30" <br />HEATPUMP <br />INDOOR <br />UNIT IN <br />ATTIC <br />KITCHEN <br />(N <br />) <br /> <br />A <br />C <br />CO <br />N <br />D <br />E <br />N <br />S <br />E <br />R <br /> <br />O <br />N <br />3" <br /> <br />C <br />O <br />N <br />C <br />R <br />E <br />T <br />E <br /> <br />P <br />A <br />D <br />2'-6" <br />2- <br />G <br />A <br />N <br />G <br />PA <br />N <br />E <br />L <br />, <br /> <br />1 <br />0 <br />0 <br />A <br />EA <br />C <br />H <br /> <br />F <br />O <br />R <br />JA <br />D <br />U <br /> <br />A <br />N <br />D <br />MA <br />I <br />N <br /> <br />U <br />N <br />I <br />T <br />AD <br />U <br /> <br />1 <br />0 <br />0 <br />A <br />PA <br />N <br />E <br />L <br />10'-6" <br />PO <br />R <br />C <br />H <br />7'-8" <br />4'-0" <br />S-A <br />HOOD VENT THROUGH ROOF, <br />300 CFM MIN., INSTALLED PER <br />MANU. SPECS. HOOD SHALL <br />COMPLY W/ ASHRAE 62.2(C) <br />LUMINAIRES LOCATED <br />ABOVE BATHTUB OR <br />SHOWER SHALL BE <br />LISTED FOR WET <br />LOCATIONS <br />SMOKE DETECTOR IN <br />LIVING ROOM (WITHIN 20' <br />FROM THE COOK TOP) <br />SHALL BE IONIZED OR <br />PHOTOELECTRIC TYPE <br />MAX. 48" MEASURED <br />FROM TOP, MIN. 15" <br />MEASURED FROM <br />BOTTOM OF BOX <br />ABOVE F.F. (TYP.) <br />WALLS AT SHOWERS <br />SHALL BE <br />TILE/CEMENT <br />PLASTER, MINIMUM 72" <br />ABOVE FLOOR. <br />GRAB BAR <br />REINFORCEMENT, MIN. <br />2x8 LUMBER, 32"-39.25" <br />ABOVE F.F. (TYP.) <br />CO SD <br />SD <br />30 AMP. <br />$VS$ <br />AFCI (TYP.) <br />$$ <br />AFCI (TYP.) <br />GFCI (TYP.) <br />$D <br />$D <br />$3D <br />$ <br />$3 <br />$3 <br />40 AMP. <br />WR-GFCI <br />AFCI (TYP.) <br />SD <br />$D <br />AFCI (TYP.) <br />SD $VS$ <br />$ <br />30 AMP. <br />AFCI (TYP.) <br />50 AMP. <br />ELEC. <br />RANGE <br />ELEC. <br />DRYER <br />3" <br />WR-GFCI <br />TEMP. <br />GLASS <br />10 <br />SD-2 <br />1-HR RATED <br />OVERHANG <br />AND WALL <br />10 <br />SD-2 <br />1-HR RATED <br />OVERHANG <br />AND WALL <br />CO SD <br />$VS <br />$3D <br />EATON 2-POLE SPD <br />OR APPROVED <br />COMPATIBLE <br />FIREPLACE TO <br />BE REMOVED <br />PORCH BEDROOM 1 <br />D <br />WKITCHEN <br />DINING <br />AREA <br />GARAGE <br />LIVING AREA <br />BEDROOM 2 <br />BEDROOM 3 <br />(E) 100 AMP. <br />ELEC. PANEL WH36"36" VINYL WINDOW <br />24"24" <br />VINYL WINDOW <br />48 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />48 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />10 <br />8 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />60 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />60 <br />" <br />4 <br />8 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />96 <br />" <br />3 <br />6 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />96 <br />" <br />3 <br />6 <br />" <br /> <br />V <br />I <br />N <br />Y <br />L <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />24"24" <br />VINYL WINDOW <br />15.5'7' GARAGE DOOR W/ AUTO. OPENER <br />42'-2" <br />24'-6" <br />57'-10" <br />11'-1" <br />17'-10"4'-3"20'-1" <br />13'-8" <br />19'-8" <br />2'-5" <br />11'-0" <br />14'-0" <br />19'-4" <br />ATTIC <br />ACCESS <br />UL 2034/2075 RATED <br />@ (E) HOUSE <br />CO <br />UL 217 RATED @ <br />(E) HOUSE (TYP.) <br />SD <br />SD <br />SD <br />SD <br />SD <br />F.A.U. ON <br />ATTIC <br />BA <br />T <br />H <br /> <br />1 <br />BA <br />T <br />H <br /> <br />2 <br />WINDOW TO BE <br />FILLED IN WITH <br />2x4 STUD WALL <br />WALL TO BE REMOVED <br />FOR NEW DOOR <br />WINDOW TO BE <br />FILLED IN WITH <br />2x4 STUD WALL <br />(N) ADU FLOOR PLAN <br />SCALE: 1/4" = 1'-0" <br />NEW WALL, 2x4 STUDS @ <br />16" O.C. U.N.O. <br />EXISTING STUD WALL <br />WALL LEGENDCARBON MONOXIDE AND SMOKE DETECTOR NOTES <br />SMOKE DETECTOR SHALL BE PROVIDED IN EACH SLEEPING ROOM <br />AND AREA GIVING ACCESS TO THE SLEEPING ROOMS <br />1. NEW CONSTRUCTION: CO AND SMOKE DETECTORS SHALL RECEIVE <br />THEIR PRIMARY POWER FROM BUILDING WIRING WITH BATTERY <br />BACKUP. <br />2. EXISTING MAIN HOUSE: BATTERY POWERED UL 2034/2075 RATED <br />CARBON MONOXIDE ALARM AND UL 217 RATED SMOKE ALARMS SHALL <br />BE INSTALLED IN MARKED LOCATIONS. <br />ELECTRICAL NOTES <br />1.PROVIDE ONE 20 AMP. CIRCUIT FOR BATHROOM OUTLETS. SUCH CIRCUIT SHALL HAVE NO OTHER <br />OUTLETS. <br />2.PROVIDE 2 DEDICATED GENERAL APPLIANCE CIRCUITS TO THE KITCHEN AREA. <br />3.ALL INSTALLED LUMINAIRES MUST BE HIGH EFFICACY IN ACCORDANCE WITH TABLE 150.0-A. <br />4.ALL RECEPTACLES IN BATHROOMS SHALL BE G.F.C.I. <br />5.SERVICE PANEL/METER UPGRADE OR NEW: OBTAIN LOCATION APPROVAL FROM THE ELECTRICAL <br />PROVIDER. <br />6.ALL BRANCH CIRCUITS SUPPLYING RECEPTACLE OUTLETS IN KITCHENS, BEDROOMS, FAMILY <br />ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, DENS, SUNROOMS, HALLWAYS, CLOSETS AND <br />SIMILAR ROOMS/AREAS SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER (AFCI). <br />7.NON-HIGH EFFICACY LUMINAIRES SHALL BE SWITCHED ON A SEPARATE CIRCUIT FROM HIGH <br />EFFICACY LUMINAIRES. <br />8.ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED <br />HORIZONTALLY BY 24" . BACK AND SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT <br />AND BACKED WITH 2" MIN. MINERAL FIBER INSULATION. <br />9.ALL RECEPTACLE OUTLETS SHALL BE LISTED AS TAMPER-RESISTANT OUTLETS. <br />10.ALL OUTDOOR LIGHTING MOUNTED TO A RESIDENTIAL BUILDING SHALL BE HIGH EFFICACY LIGHTING <br />OR CONTROLLED BY A PHOTOCELL AND MOTION SENSOR COMBINATION. <br />PLUMBING NOTES <br />1.BATH FAN SHALL BE CONTROLLED BY HUMIDISTAT WITH ADJUSTMENT BETWEEN A RELATIVE <br />HUMIDITY RANGE 50-80%. <br />2.SHOWER WALLS ABOVE BATHTUB WITH SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, <br />NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 6' ABOVE FLOOR. <br />3.SHOWER COMPARTMENT SHALL BE MINIMUM 1,024 SQ. IN. AND SHALL BE CAPABLE OF <br />ENCOMPASSING A 30 IN. CIRCLE. <br />4.PROVIDE A 12"x12" MINIMUM ACCESS PANEL TO BATHTUB TRAP CONNECTION UNLESS PLUMBING IS <br />WITHOUT SLIP JOINTS (CPC 405.2). <br />5.ALL TOILETS SHALL BE 1.28 GPF, SHOWERHEADS 2.0 GPM, AND FAUCETS 1.2 GPM, KITCHEN FAUCET <br />1.8 GPM. <br />6.FOR SHOWERS OR TUB-SHOWERS MAX. TEMPERATURE OF 120 DEGREE TO BE PROVIDED BY THE <br />USE CONTROL VALVE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE. <br />7.ALL GLAZING IN ALL DOORS, BATH/SHOWER ENCLOSURES MUST BE IDENTIFIED BY A LABEL AS A <br />SAFETY GLAZING. <br />8.WALL COVERING IN SHOWERS AND TUBS TO BE CEMENT PLASTER OR TILE EQUAL TO 72" ABOVE <br />DRAIN. ENCLOSURES MUST BE OF APPROVED SAFETY GLAZING AND DOORS MUST SWING OUT OF <br />SHOWERS. WINDOWS IN ENCLOSURE WALLS SHALL BE LABELED SAFETY GLAZING WHEN LESS THAN <br />60" ABOVE THE DRAIN, TYPICAL FOR ALL BATHROOMS. <br />9.GREEN BOARD GYPSUM OR WATER RESISTANT GYPSUM BOARD SHALL NOT BE USED AS BACKING <br />FOR CEILING FINISH INSIDE BATHROOM DUE TO CONDENSATION OR VAPOR. <br />10.WATER HEATER: SIZE PER TITLE 24 WITH VENT THROUGH OUTSIDE. PROVIDE P&T RELIEF VALVE ON <br />WATER HEATER. PROVIDE SMITTY PAN WITH DRAIN INSULATION/CLEARANCE PER MANUFACTURER <br />SPECS. WATER HEATER TANK (IF USED) MUST BE ADEQUATELY BRACED TO RESIST SEISMIC <br />FORCES: PROVIDE 2 STRAPS, 1 STRAP AT TOP 1/3 OF TANK AND 1 STRAP AT BOTTOM 1/3 OF THE <br />TANK. <br />11.PLUMBING VENT TERMINATIONS SHALL BE AT LEAST 10' FROM FRESH AIR INTAKE OR VENTILATION. <br />12.B-VENTS SHALL TERMINATE AT LEAST 4' FROM FRESH AIR INTAKE OR VENTILATION. <br />WINDOW SCHEDULE <br />WINDOWS' U-FACTOR = 0.3 AND SHGC = 0.23 <br />A 48"x48" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />B 48"x24" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />C 60"x48" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />D 36"x48" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />E 36"x36" SLIDING GLASS W/D, DUAL GLAZING, VINYL FRAME <br />F 36"x18" S.L. FROSTED GLASS W/D, DUAL GLAZING, VINYL FRAME, <br />TEMPERED GLASS <br />G 30"x18" S.L. FROSTED GLASS W/D, DUAL GLAZING, VINYL FRAME, <br />TEMPERED GLASS <br />DOOR SCHEDULE <br />1 30"x80" HOLLOW CORE DOOR <br />2 28"x80" HOLLOW CORE DOOR <br />3 36"x80" SOLID CORE DOOR W/ TEMPERED GLASS (U-FACTOR = 0.2) <br />4 30"x80" EXTERIOR RATED SOLID FRENCH DOOR (U-FACTOR = 0.2) <br />5 60"x80" CLOSET SLIDING DOOR <br />6 24"x80" EXTERIOR RATED DOOR WITH LOUVERS DETAILED HEREON <br />7 36"x80" HOLLOW CORE DOOR <br />BATHROOM NOTE <br />CEMENT, FIBER CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR <br />FIBER-REINFORCED GYPSUM BACKERS SHALL BE USED AS A BASE FOR WALL TILE IN TUB AND <br />SHOWER AREAS AND WALL AND CEILING PANELS IN SHOWER AREAS. <br />(N <br />) <br /> <br />A <br />D <br />U <br /> <br />A <br />N <br />D <br />(E <br />) <br /> <br />M <br />A <br />I <br />N <br /> <br />U <br />N <br />I <br />T <br />FL <br />O <br />O <br />R <br /> <br />P <br />L <br />A <br />N <br />SHEET <br />A2 <br />REVISION <br />DATE BY <br />1 <br />2 <br />3 <br />PROJECT ENGINEER <br />BEN PHAN <br />10822 WOODWARD LN <br />GARDEN GROVE, CA 92840 <br />TEL: (714) 251 4537 <br />ELEC. BOX HEIGHT <br />N.T.S. <br />AGING-IN-PLACE NOTES <br />A. REINFORCEMENT FOR GRAB BARS - AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH <br />REINFORCEMENT INSTALLED IN ACCORDANCE WITH CRC R327.1. <br />1) REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. <br />2) REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH NOMINAL LUMBER (1-1/2 INCH BY 7-1/4 INCH ACTUAL DIMENSION) OR <br />OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED <br />BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR, FLUSH WITH THE WALL FRAMING. <br />3) WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE <br />BACK WALL. <br />4) SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5) BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB <br />AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE <br />BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. <br />6) WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE <br />BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR <br />REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. <br />7) REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB <br />WALL PANELS WITH INTEGRAL FACTORY- INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB <br />BARS IS PROVIDED. <br />8) SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE <br />PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS <br />APPROVED BY THE ENFORCING AGENCY. <br />9) BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF <br />REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS <br />ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. <br />10) REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE <br />SLAB FLOORS. <br />B. DOCUMENTATION FOR GRAB BAR REINFORCEMENT - INFORMATION AND/OR DRAWINGS IDENTIFYING THE LOCATION OF GRAB <br />BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE MANUAL IN ACCORDANCE WITH THE <br />CALIFORNIA GREEN BUILDING STANDARDS CODE, CHAPTER 4, DIVISION 4.4. (CRC R327.1.1.1) <br />C. ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS - ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND <br />CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS <br />SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES <br />MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. (CRC R327.1.2). EXCEPTIONS: <br />1) DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS AND CEILING <br />LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. <br />2) RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON A WALL SPACE WHERE THE DISTANCE <br />BETWEEN THE FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A WINDOW, IS LESS THAN 15 <br />INCHES. <br />D. DOORBELL BUTTONS - DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) <br />ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL <br />BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED <br />FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A <br />HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE <br />DOORBELL BUTTON OR CONTROL. (CRC R327.1.4) <br />WATER HEATER - DRYER - <br />F.A.U. DOOR DETAIL <br />N.T.S. <br />SD <br />LEGEND <br />GFCI RECEPTACLE <br /> WR GFCI WEATHER RESISTANT RECEPTACLE <br />TAMPER RESISTANT RECEPTACLE, 120V SINGLE PHASE, 20A, <br /> CONTROLLED BY ARC-FAULT CIRCUIT INTERRUPTER (AFCI) <br />240V DEDICATED OUTLET, AMPERAGE AS INDICATED IN PLAN <br />CEILING-MOUNT RECESS LIGHT <br />OUTDOOR WALL-MOUNT LIGHT FIXTURE W/ PHOTOCELL & MOTION SENSOR <br /> $LIGHT SWITCH WITH DIMMER (D) WHERE INDICATED <br /> $3 3-WAY LIGHT SWITCH WITH DIMMER (D) WHERE INDICATED <br /> $vs VACANCY SENSOR LIGHT SWITCH <br /> $W/D WASHER/DRYER DISCONNECT SWITCH, 20A, INSTALL PER MANU. SPECS. <br />EXHAUST FAN (100 CFM MINIMUM) W/ HUMIDITY CONTROL <br />IN-SINK DISPOSAL <br />AIR REGISTER ON CEILING <br />SMOKE DETECTOR <br />CARBON MONOXIDE DETECTOR <br />4" DRYER VENT W/ DAMPER, TERMINATED 30" ABOVE F.F. ON OUTSIDE WALL <br />4" SMOOTH SURFACE VENT W/ APPROVED WALL STRAP, TERMINATED ABOVE <br />ROOF THRU. APPROVED FLASHING, 14' LONG MAX., 2 ELBOWS MAX. <br /> W/H 240V-50 GAL. WATER HEATER TANK, RHEEMTM MODEL XE50T10H22U <br /> W CLOTHES WASHER <br /> D CLOTHES DRYER <br />HOSE BIB WITH ANTI-SIPHON VALVE <br />AIR RETURN ON CEILING <br />ROOF-MOUNT ATTIC VENT <br />IAQ FAN (PER TITLE 24), 80 CFM MINIMUM <br />CO <br />18" <br />18" <br />PER PLAN <br />100 SQ. IN. MIN. ON <br />EACH LOUVER @ <br />TOP AND BOTTOM <br />80" <br />15" <br />MIN. <br />48" <br />MAX. <br />F.F. <br />DATE 11/20/2023 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />7 <br />4 <br />9 <br /> <br />S <br />F <br /> <br />A <br />D <br />U <br />23 <br />5 <br /> <br />S <br />F <br /> <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br /> <br />A <br />N <br />D <br />AT <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />4 <br />4 <br />7 <br /> <br />S <br />F <br /> <br />J <br />A <br />D <br />U <br />(E) UNIT FLOOR PLAN <br />SCALE: 3/16" = 1'-0" <br />OW <br />N <br />E <br />R <br />OK <br /> <br />H <br />A <br /> <br />F <br />A <br />M <br />I <br />L <br />Y <br /> <br />L <br />I <br />M <br />I <br />T <br />E <br />D <br /> <br />P <br />A <br />R <br />T <br />N <br />E <br />R <br />S <br />H <br />I <br />P <br />TE <br />L <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />8 <br />5 <br />6 <br /> <br />5 <br />9 <br />7 <br />7 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />MA <br />I <br />N <br /> <br />U <br />N <br />I <br />T <br />: <br /> <br />1 <br />6 <br />1 <br />3 <br /> <br />W <br /> <br />C <br />H <br />E <br />S <br />T <br />N <br />U <br />T <br /> <br />A <br />V <br />E <br />JA <br />D <br />U <br />: <br /> <br />1 <br />6 <br />1 <br />3 <br /> <br />W <br /> <br />C <br />H <br />E <br />S <br />T <br />N <br />U <br />T <br /> <br />A <br />V <br />E <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />AD <br />U <br />: <br /> <br />1 <br />6 <br />1 <br />3 <br /> <br />W <br /> <br />C <br />H <br />E <br />S <br />T <br />N <br />U <br />T <br /> <br />A <br />V <br />E <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />3 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />1613 W Chestnut Ave, #2 <br />& #312/12/2024