Laserfiche WebLink
MAIN <br />E.P <br />TELE <br />E.P <br />O'REILLY <br />AUTO PARTS <br />(APPROX. 6,575 S.F.) <br />O'REILLY <br />AUTO PARTS <br />(APPROX. +6,575 S.F.) <br />WELCOME <br />CENTER <br />9' <br />- <br />8 <br />" <br />4' <br />4' <br />- <br />7 <br />" <br />4' <br />CO <br />K <br />E <br />3' <br />4'-9" <br />3'-8" <br />3' <br />A <br />D <br />A <br />3' <br />8' <br />12 <br />' <br />3' <br />3' <br />- <br />6 <br />" <br />9' <br />- <br />6 <br />" <br />10'-10" <br />8' <br />- <br />1 <br />" <br />ELEC. <br />ROOM <br />N.I.C <br />3' <br />- <br />8 <br />" <br />3' <br />- <br />8 <br />" <br />4' <br />5' <br />4'-3" <br />4' <br />3' <br />- <br />8 <br />" <br />5' <br />- <br />7 <br />" <br />9' <br />- <br />9 <br />" <br />3' <br />- <br />8 <br />" <br />4' <br />- <br />8 <br />" <br />6'-3" <br />5' <br />- <br />8 <br />" <br />4' <br />3' <br />- <br />1 <br />0 <br />" <br />4'-7" <br />3' <br />- <br />1 <br />0 <br />" <br />3' <br />- <br />8 <br />" <br />9' <br />- <br />6 <br />" <br />9' <br />- <br />6 <br />" <br />3'-11" <br />WIPER <br />TE <br />S <br />T <br />WIPER <br />BATTERY <br />RACK GRAVITY FEED OIL RACK <br />6' <br />- <br />3 <br />" <br />9'-3" <br />6' <br />- <br />6 <br />" <br />LA <br />T <br />H <br />E <br />OIL TANK <br />3' <br />- <br />8 <br />" <br />3' <br />- <br />1 <br />0 <br />" <br />3' <br />- <br />8 <br />" <br />3' <br />- <br />1 <br />0 <br />" <br />3' <br />- <br />1 <br />0 <br />" <br />DN <br />DN <br />PRIMARY USE GROUP: (MERCANTILE) <br />CONSTRUCTION TYPE: "VB" <br />TOTAL GROSS SQ. FT.: +6,575 <br />EXITEXIT <br />132'-8 <br />" <br /> <br />= <br /> <br />1 <br />3 <br />3 <br />' <br /> <br />/ <br /> <br />13 = 44. <br />3 <br />3 <br />" <br />5'5'5' <br />3'-8" <br />5'-1"10'-10"6'-7" <br />7' <br />- <br />9 <br />" <br />3' <br />EXISTING BLDG USE TO REMAIN. NO CHANGE IN BUILDING SQUARE FOOTAGE. <br />EXIT ROUTE <br />EXITEXIT <br />EX <br />I <br />T <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br /> <br />P <br />A <br />T <br />H <br /> <br />O <br />F <br /> <br />T <br />R <br />A <br />V <br />E <br />L <br /> <br />= <br /> <br />6 <br />0 <br />' <br />- <br />1 <br />0 <br />" <br /> <br />< <br /> <br />7 <br />5 <br />' <br />- <br />0 <br />" <br />62'-3" <br />77'- <br />5 <br />" <br /> <br />/ <br /> <br />1 <br />/ <br />3 <br /> <br />= <br /> <br />2 <br />5 <br />' <br />30'-11" <br />EX <br />I <br />T <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br /> <br />P <br />A <br />T <br />H <br /> <br />O <br />F <br /> <br />T <br />R <br />A <br />V <br />E <br />L <br />: <br /> <br />7 <br />3 <br />' <br />- <br />4 <br />" <br /> <br />< <br /> <br />7 <br />5 <br />' <br />EXIT <br />EX <br />I <br />T <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br /> <br />P <br />A <br />T <br />H <br /> <br />O <br />F <br /> <br />T <br />R <br />A <br />V <br />E <br />L <br /> <br />= <br /> <br />6 <br />4 <br />' <br />- <br />0 <br />" <br /> <br />< <br /> <br />7 <br />5 <br />' <br />- <br />0 <br />" <br />EXIT ACCESS PATH OF TRAVEL: 70'-5" < 75' <br />EXIT <br />EXIT <br />EXIT <br />COMMON PATH OF EGRESS TRAVEL <br />EXIT ACCESS TRAVEL DISTANCE <br />1 CODE SUMMARY EGRESS PLAN <br />SCALE: 1/8" = 1'-0" <br />09/05/2024 <br />22.0363.00 <br />MF AB <br />CO <br />R <br />P <br />O <br />R <br />A <br />T <br />E <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />S <br />23 <br />3 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />P <br />A <br />T <br />T <br />E <br />R <br />S <br />O <br />N <br />SP <br />R <br />I <br />N <br />G <br />F <br />I <br />E <br />L <br />D <br />, <br /> <br />M <br />I <br />S <br />S <br />O <br />U <br />R <br />I <br /> <br />6 <br />5 <br />8 <br />0 <br />2 <br />(4 <br />1 <br />7 <br />) <br /> <br />8 <br />6 <br />2 <br />- <br />2 <br />6 <br />7 <br />4 <br /> <br />T <br />E <br />L <br />E <br />P <br />H <br />O <br />N <br />E <br />AU <br />T <br />O <br /> <br />P <br />A <br />R <br />T <br />S <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />RE <br />M <br />O <br />D <br />E <br />L <br /> <br />O <br />' <br />R <br />E <br />I <br />L <br />L <br />Y <br /> <br />A <br />U <br />T <br />O <br /> <br />P <br />A <br />R <br />T <br />S <br /> <br />S <br />T <br />O <br />R <br />E <br />25 <br />4 <br />7 <br /> <br />W <br />. <br /> <br />M <br />C <br />F <br />A <br />D <br />D <br />E <br />N <br /> <br />A <br />V <br />E <br />. <br /> <br />S <br />U <br />I <br />T <br />E <br /> <br />B <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />2 REAR <br />31 <br />A <br />7N <br />OF <br />TE <br />C <br />-OF <br />- <br />LI <br />K <br />No. C-20397 <br />RDE <br />J <br />HON <br />IC <br />S <br />L <br />E SN H <br />T <br />A <br />A <br />TU <br />AM <br />S <br />ETIH <br />NI5 <br />C <br />C <br />0 <br />3 <br />PR#13 09/24/2024 <br />OCCUPANCY LOAD SUMMARY <br />ROOM OR AREA <br />(REFER TO FLOOR PLAN) <br />OCCUPANCY <br />GROUP <br />AREA <br />(S.F) <br />AREA PER <br />OCCUPANT <br />(S.F.) <br />OCCUPANTS <br />(QTY) <br />100 ------- PARTS AREA "A" <br />100A ----- VESTIBULE <br />101 ------- PARTS AREA "B" <br />102 ------- OFFICE <br />103 ------- RESTROOM <br />104 ------- RESTROOM <br />M <br />- <br />S-1 <br />B <br />- <br />- <br />2,799 <br />45 <br />3,443 <br />86 <br />65 <br />65 <br />60 <br />N/A <br />300 <br />100 <br />N/A <br />N/A <br />47 <br />N/A <br />11 <br />1 <br />N/A <br />N/A <br />TOTAL OCCUPANCY 59 <br />A <br />B <br />C <br />D <br />REFER TO PROJECT MANUAL FOR ADDITIONAL REQUIREMENTS. <br />REFER TO PLANS, SECTIONS, AND DETAILS FOR CONSTRUCTION OF <br />FIRE RATED ASSEMBLIES. WHERE UNDERWRITERS LABORATORY <br />(UL) TEST NUMBERS ARE REFERENCED, CONTRACTOR SHALL <br />PROVIDE CONSTRUCTION MATERIALS, MEANS AND METHODS TO <br />COMPLY WITH TESTED ASSEMBLY. <br />REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR <br />ADDITIONAL REQUIREMENTS. <br />OWNER FURNISHED AND INSTALLED FURNISHINGS AND FIXTURES <br />SHOWN FOR REFERENCE ONLY. <br />CONTRACTOR TO PROVIDE PORTABLE FIRE EXTINGUISHERS <br />DURING CONSTRUCTION AS REQUIRED TO PROTECT THE WORK <br />AREA AND EACH STORAGE UNIT AND JOB TRAILER PER THE FIRE <br />CODE. <br />SURFACE MOUNTED PORTABLE FIRE EXTINGUISHERS SHALL BE UL <br />LISTED ABC TYPE, WITH 10 LBS. CAPACITY. REFER TO DETAIL <br />10/A4.2 FOR TYPICAL MOUNTING REQUIREMENTS. <br />EXIT DISCHARGE DOORS, PROVIDE TACTILE EXIT SIGNS STATING <br />"EXIT" WITH BRAILLE (GRADE 2 CONTRACTED) LETTERING. SIGN <br />CONSTRUCTION AND MOUNTING TO COMPLY WITH ANSI A117.1. <br />REFER TO FLOOR PLAN FOR LOCATIONS. <br />EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS <br />SIDE WITHOUT THE USE OF A KEY OR <br />SPECIAL KNOWLEDGE OR EFFORT <br />THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE <br />ILLUMINATED TO A LEVEL OF NOT LESS THAN ONE FOOT-CANDLE <br />AT THE WALKING SURFACE AT ALL TIMES THE BUILDING SPACE <br />SERVED BY THE MEANS OF EGRESS IS OCCUPIED. <br />EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED <br />AT ALL TIMES. EXTERNALLY ILLUMINATED EXIT SIGNS SHALL BE <br />CONNECTED TO AN EMERGENCY POWER SYSTEM (BATTERIES, UNIT <br />EQUIPMENT OR AN ON-SITE GENERATOR) THAT WILL <br />AUTOMATICALLY ILLUMINATE THE EXIT SIGNS FOR A DURATION OF <br />NOT LESS THAN 90 MINUTES IN CASE OF PRIMARY POWER LOSS. <br />GENERAL <br />IPC TABLE 403.1 <br />PRIMARY OCCUPANCY: (M) MERCANTILE <br />TOTAL OCCUPANCY: 59 <br />OCCUPANCY LOAD CALCULATED PER SEX: <br />FEMALE: 59 / 2 = 30 <br />MALE: 59 / 2 = 30 <br />PLUMBING FIXTURES <br />WATER CLOSETS (URINALS):1 PER 500 <br />REQUIRED FOR FEMALE:59/500 = 1 <br />PROVIDED FOR FEMALE:1 <br />REQUIRED FOR MALE:59/500 = 1 <br />PROVIDED FOR MALE:1 AND 1 URINAL <br />LAVATORIES:1 PER 750 <br />REQUIRED FOR FEMALE:59/750 = 1 <br />PROVIDED FOR FEMALE:1 <br />REQUIRED FOR MALE:59/750 = 1 <br />PROVIDED FOR MALE:1 <br />DRINKING FOUNTAINS:1 PER 1,000 <br />REQUIRED:59/1000 = 1 <br />PROVIDED:2 <br />SERVICE SINK REQUIRED:1 <br />SERVICE SINK PROVIDED:1 <br />E <br />F <br />G <br />BUILDING CODE <br />SYMBOLS LEGEND <br />UPON REQUEST OWNER TO PROVIDE UNDER SEPARATE COVER, <br />PROJECT HAZARDOUS MATERIALS INVENTORY STATEMENT (HMIS) <br />FOR COMMODITY TYPES, HAZARD CLASS, AND QUANTITIES. <br />OWNER RESPONSIBLE FOR MONITORING INVENTORY COMMODITY <br />TYPES AND QUANTITIES TO NOT EXCEED CODE REQUIREMENTS. <br />THE STOCK IN THE STOCKROOM IS OF THE SAME HAZARD <br />CLASSIFICATION AS THAT FOUND IN THE MAIN RETAIL AREA. <br />THE STOCKROOM DOORS SHALL NOT HAVE LOCKING HARDWARE ON <br />THE EGRESS SIDE. <br />A <br />B <br />HAZARDOUS MATERIALS <br />INVENTORY STATEMENT (HMIS) <br />CO <br />D <br />E <br /> <br />S <br />U <br />M <br />M <br />A <br />R <br />Y <br /> <br />P <br />L <br />A <br />N <br />G1.1 <br />PLANNING DEPARTMENT CONTACT <br />NUMBER:(714) 667-2708 <br />BUILDING DEPARTMENT CONTACT <br />NUMBER:(714) 647-5851 <br />OC FIRE AUTHORITY CONTACT <br />NUMBER:(714) 567-3236 <br />GOVERNING CODES AND ORDINANCES <br />CALIFORNIA ADMINISTRATIVE CODE <br />TITLE 24: 2022 CAC <br />CALGREEN: 2022 <br />CALIFORNIA BUILDING CODE:2022 CBC <br />CALIFORNIA MECHANICAL CODE:2022 CMC <br />CALIFORNIA ELECTRICAL CODE:2022 CEC <br />CALIFORNIA PLUMBING CODE:2022 CPC <br />CALIFORNIA FIRE CODE:2022 CFC <br />ACCESSIBILITY CODE:2022 CBC CH. 11 <br />USE GROUP & CONSTRUCTION TYPE <br />PRIMARY USE GROUP:M (MERCANTILE), S-1 <br />MIXED USE AND OCCUPANCY:NONSEPARATED <br />CONSTRUCTION TYPE:VB <br />AREA MODIFICATIONS <br />FRONTAGE INCREASE:NOT APPLIED <br />AUTOMATIC SPRINKLER INCREASE:NOT PROVIDED <br />ACTUAL HEIGHT & BUILDING AREA <br />NO. OF STORIES:1 STORY <br />BUILDING HEIGHT:+22'-3" <br />GROSS BUILDING AREA:6,575 SQ. F.T <br />FIRE PROTECTION SYSTEMS <br />AUTOMATIC SPRINKLER SYSTEM:YES <br />PORTABLE FIRE EXTINGUISHERS:YES <br />FIRE ALARM SYSTEM:YES <br />AUTOMATIC DETECTION SYSTEM: <br />COMMERCIAL ENERGY EFFICIENCY CODE <br />COMPLIANCE WITH BUILDING ENERGY EFFICIENCY REQUIREMENTS BASED <br />UPON APPLICABLE ENERGY CODE (PERFORMANCE METHOD). <br />NOTES: <br />CERTIFICATE OF COMPLIANCE AND CALCULATIONS TO BE PROVIDED UPON <br />REQUEST UNDER SEPARATE COVER. <br />THE PROJECT SHALL COMPLY WITH CEC TITLE 24 FOR ENERGY <br />COMPLIANCE. <br />THE TENANT SPACE, THE MAIN ENTRANCES AND EXITS, PATH OF TRAVEL <br />AND SANITARY FACILITIES SERVING THE TENANT SPACE SHALL BE <br />ACCESSIBLE TO PERSONS WITH DISABILITIES PER CBC TITLE 24 DISABLED <br />ACCESS COMPLIANCE. <br />ALL AREAS OF NEWLY DESIGNED AND NEWLY CONSTRUCTED BUILDINGS <br />AND FACILITIES AND ALTERED PORTIONS OF EXISTING BUILDINGS AND <br />FACILITIES SHALL COMPLY WITH SECT. 11B-201.1. <br />ALL EXTERIOR DOORS, WINDOWS AND ROOF OPENINGS SHALL COMPLY <br />WITH THE UNIFORM BUILDING SECURITY CODE. <br />BIDDING INFORMATION: <br />REFER TO OWNER'S WEB SITE: <br />HTTP://WWW.OREILLYPLANROOM.COM <br />NOTE: REFER TO CURRENT PROJECTS LIST, LOCATED <br />AT BOTTOM OF SIGN IN PAGE, FOR INVITED GENERAL <br />CONTRACTORS. <br />ALL SUB-CONTRACTOR BIDS TO BE SUBMITTED TO <br />INVITED GENERAL CONTRACTORS ONLY. <br />CONTACT OWNER'S DESIGNATED REPRESENTATIVE <br />FOR ADDITIONAL PROJECT INFORMATION <br />GENERAL NOTES <br />A. CONTRACT ADMINISTRATION (LIMITED SERVICE): <br />THE ARCHITECT AND/OR ENGINEER OF RECORD INDICATED HEREIN ARE <br />PROVIDING A LIMITED SERVICE AND NOT PROVIDING CONTRACT <br />ADMINISTRATION SERVICES FOR THIS PROJECT WHICH IS THE <br />RESPONSIBILITY OF OTHERS. THE ARCHITECT AND/OR ENGINEER ARE NOT <br />RESPONSIBLE <br />FOR FIELD ACTIVITIES ON THIS PROJECT WITHOUT DIRECT INSPECTION OF <br />THE WORK IN PROGRESS. IF FIELD CONDITIONS ARE UNCOVERED THAT <br />REQUIRE A CHANGE OR ADDITIONAL INFORMATION, THE ARCHITECT <br />AND/OR ENGINEER DOES NOT DELEGATE AUTHORITY TO ANYONE ELSE <br />FOR DETERMINING THE MEANING OF PLANS OR <br />SPECIFICATIONS AS AUTHENTICATED HEREIN. <br />B. QUALITY STANDARDS AND BUILDING CODES: <br />CONTRACTORS SHALL BE RESPONSIBLE FOR KNOWING THE QUALITY AND <br />PUBLIC SAFETY REGULATIONS SET FORTH IN THE GOVERNING CODES <br />AND OTHER APPLICABLE REGULATIONS OF LOCAL AND STATE AGENCIES <br />HAVING <br />JURISDICTION WHICH GOVERN EACH CONTRACTOR'S WORK. <br />C. EXISTING CONDITIONS: <br />FIELD VERIFY EXISTING CONDITIONS BY DETAILED INSPECTION PRIOR TO <br />SUBMITTING BID AND BEGINNING WORK. NOTIFY THE ARCHITECT AND/OR <br />ENGINEER OF RECORD IF EXISTING CONDITIONS DEVIATE SUBSTANTIALLY <br />FROM THOSE INDICATED HEREIN <br />QUALITY CONTROL <br />1. REFER TO PROJECT MANUAL, SECTION 01 45 16 - QUALITY CONTROL <br />PROCEDURES, FOR ADDITIONAL REQUIREMENTS. <br />2. WHERE REQUIRED, THE OWNER SHALL PROVIDE THE SERVICES OF AN <br />INDEPENDENT TESTING LABORATORY TO <br />PERFORM TESTING AND SPECIAL INSPECTIONS INDICATED. <br />CLEAR FLOOR AREA (EXIT DOOR AND / OR FIRE EXTINGUISHER) <br />EXIT ACCESS TRAVEL DISTANCE (LENGTH IN FEET) <br />FIRE EXTINGUISHER (SURFACE MOUNTED) <br />PLUMBING FIXTURE SUMMARY <br />GENERAL NOTES <br />H <br />I <br />J <br />C <br />D <br />PARTS AREA "A" <br />100 <br />OFFICE <br />102 <br />RESTROOM <br />103 <br />PARTS AREA "B" <br />101 <br />VESTIBULE <br />100A <br />RESTROOM <br />104 <br /> "EXIT ROUTE" TACTILE SIGNAGE <br />GENERAL NOTES: <br />1.SIGNS SHALL COMPLY WITH & CONFORM TO ANSI ICC-A117.1-2017 <br />STANDARDS FOR ACCESSIBLE DESIGN OR BY LOCAL ACCESSIBILITY <br />GUIDELINES WHICHEVER IS MORE STRINGENT. <br />2.ALL ENTRANCES THAT ARE ACCESSIBLE AND USABLE BY PERSONS <br />WITH DISABILITIES SHALL BE IDENTIFIED WITH A MINIMUM OF ONE <br />"INTERNATIONAL SYMBOL OF ACCESSIBILITY". <br />3.ACCESSIBLE SIGNS TO BE INSTALLED ON THE LATCH SIDE OF THE <br />DOOR, OR IF NO SPACE, ON THE NEAREST WALL PREFERABLY ON <br />THE RIGHT. ALL SIGNS MUST BE A DISTINCTLY DIFFERENT FROM ITS <br />MOUNTING SURFACE IN COLOR/CONTRAST. <br />4.GENERAL CONTRACTOR TO PROVIDE TACTILE "EXIT" SIGNS AT ALL <br />GRADE LEVEL EXIT DOORS. UNLESS OTHERWISE REQUIRED BY <br />LOCAL AUTHORITY, INSTALL PER ADA COMPLIANT ON THE WALL <br />ADJACENT TO THE LATCH SIDE OF THE DOOR WITH CONTRASTING <br />AND RAISED PICTOGRAPH, SANS SERIF LETTERING AND GRADE 2 <br />BRAILLE. <br />SANS-SERIF UPPERCASE CHARACTERS, <br />RAISED 1/32" PER ANSI STANDARDSEXIT <br />ROUTE <br />5 <br />8" <br />T <br />O <br />2" <br /> <br />M <br />A <br />X <br />. <br />3 <br />8" <br />MI <br />N <br />. <br />CHARACTERS & BACKGROUND OF <br />SIGNS TO BE NON-GLARE FINISH AND <br />TO CONTRAST WITH EACH OTHER. <br />(STANDARD COLOR: WHITE TEXT ON <br />GREY BACKGROUND) COLOR & <br />CONTRAST OF SIGN TO BE DISTINCTLY <br />DIFFERENT THAN COLOR & CONTRAST <br />OF WALL. <br />CORRESPONDING GRADE II BRAILLE <br />PER ANSI STANDARDS <br />EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE-LEVEL <br />EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE OR AN <br />EXIT PASSAGEWAY SHALL BE IDENTIFIED BY A TACTILE EXIT <br />WITH THE WORDS, "EXIT ROUTE" <br />60 <br />" <br /> <br />M <br />A <br />X <br /> <br />A <br />F <br />F <br />48 <br />" <br /> <br />M <br />I <br />N <br /> <br />A <br />F <br />F <br />EXIT SANS-SERIF UPPERCASE CHARACTERS, <br />RAISED 1/32" PER ANSI STANDARDS <br />CHARACTERS & BACKGROUND OF <br />SIGNS TO BE NON-GLARE FINISH AND <br />TO CONTRAST WITH EACH OTHER. <br />(STANDARD COLOR: WHITE TEXT ON <br />GREY BACKGROUND) COLOR & <br />CONTRAST OF SIGN TO BE DISTINCTLY <br />DIFFERENT THAN COLOR & CONTRAST <br />OF WALL. <br />CORRESPONDING GRADE II BRAILLE <br />PER ANSI STANDARDS <br />EACH GRADE-LEVEL EXTERIOR EXIT DOOR SHALL BE <br />IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORD "EXIT" <br /> "EXIT" TACTILE SIGNAGE <br />5 <br />8" <br />T <br />O <br />2" <br /> <br />M <br />A <br />X <br />. <br />60 <br />" <br /> <br />M <br />A <br />X <br /> <br />A <br />F <br />F <br />48 <br />" <br /> <br />M <br />I <br />N <br /> <br />A <br />F <br />F <br />3 <br />8" <br />MI <br />N <br />. <br />2 TACTILE EGRESS SIGNAGE <br />SCALE: NTS <br />2 <br />2 <br />2 <br />2 <br />3 <br />3 <br />2547 W McFadden Ave <br />Unit# B10/7/2024