Laserfiche WebLink
A B <br />A 3'-0" W X 6'-8" H 1 3/8" EXT. SOLID CORE DOOR WOOD WOOD <br />B 2'-8" W X 6'-8" H 1 3/8"INT. HOLLOW CORE DOOR WOOD WOOD <br />MARK OPENING SIZE TICK DOOR TYPE SCREEN FRAME <br />DOOR SCHEDULE <br />F.F. <br />QTY. <br />1 <br />1 <br />C 2'-6" W X 6'-8" H 1 3/8"DOUBLE FOLDING DOOR WOOD WOOD1 <br />2' - 8" <br />C <br />6' <br /> <br />- <br /> <br />8 <br />" <br />3' - 0"2' - 6"4' - 0"5' - 0"2' - 6"4' - 0"7' - 11" <br />D E F G H <br />D <br />E <br />F <br />G <br />H <br />2 <br />1 <br />1 <br />1 <br />1 <br />4'-0" W X 6'-8" H 1 3/8" DOUBLE FOUR-WING FOLDING DOOR WOOD WOOD <br />5'-0" W X 6'-8" H 1 3/8" DOUBLE FOUR-WING FOLDING DOOR WOOD WOOD <br />2'-6" W X 6'-8" H 1 3/8"INT. HOLLOW CORE DOOR WOOD WOOD <br />8'-0" W X 6'-8" H 1 3/8" DOUBLE FOUR-WING SLIDING DOOR GLASS WOOD <br />8'-0" W X 6'-8" H 1 3/8" DOUBLE POCKET DOOR GLASS WOOD <br />U-FACTOR SHGC <br />0.29 0.22 <br />0.05 <br />6' <br /> <br />- <br /> <br />8 <br />" <br />2 <br />4'-0"W x 2'-0"H SLIDING WINDOW VINY. YES <br />MARK SIZE TYPE FRAME <br />WINDOW SCHEDULE <br />NOTES: <br />1.BEDROOM EGRESS WINDOWS HAVE A MINIMUM CLEAR OPENING AREA OF 5.7 sf. <br />ABOVE THE GRADE FLOOR AND 5 SQ.FT. ON THE GRADE FLOOR, A MIN. NET HEIGHT OF 24" <br />AND MIN. NET WIDTH OF 20", AND SILL HEIGHT NOT MORE THAN 44" MAX. ABOVE FINISH <br />FLOOR. <br />2.THE NFRC TEMPORARY LABEL DISPLAYED ON WINDOWS AND SKYLIGHTS (INCL. <br />TUBULAR) MUST REMAIN ON THE UNIT UNTIL FINAL INSPECTION HAS BEEN COMPLETED. <br />3.SHOWER AND TUB ENCLOSURES SHALL BE TEMPERED (CBC 2406.4) WINDOWS AT <br />SHOWERS AND TUBS SHALL BE TEMPERED. <br />F.F. <br />4'-0"W x 3'-0"H SLIDING WINDOW VINY.YES <br />SCREEN <br />1 <br />2 <br />QTY. <br />1 <br />1 <br />4' - 0" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />1 <br />4' - 0" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />U-FACTOR SHGC <br />0.29 0.22 <br />0.29 0.22 <br />N <br />30" MIN <br />ø 2' - 8" <br />N.Landing <br />4' x 3' <br />Landing 7 3/4" <br />max. below <br />threshold <br />Tempered <br />Glass <br />N. Gameroom <br />N. Bathroom <br />N. CL N. CL <br />N. CL <br />N. Laundry <br />N. Hallway <br />Ex. Room #3 <br />Ex. Master Bathroom <br />Ex. Kitchen <br />Ex. Hallway <br />Ex. Room #2 Ex. Living Room <br />Ex. CL Ex. CL <br />Pa <br />n <br />t <br />r <br />y <br />Pa <br />n <br />t <br />r <br />y <br />G <br />A <br />F <br />D D <br />E <br />C <br />H <br />1 <br />2 <br />F <br />B <br />15 <br />" <br />mi <br />n <br />15 <br />" <br />mi <br />n <br />19 <br />' <br /> <br />- <br /> <br />0 <br />" <br />4' - 0"3' - 8"5' - 3"5' - 1" <br />13 <br />' <br /> <br />- <br /> <br />6 <br />" <br />11 <br />' <br /> <br />- <br /> <br />8 <br />" <br />25 <br />' <br /> <br />- <br /> <br />2 <br />" <br />6' - 3"4' - 0"10' - 8" <br />21' - 4" <br />8' <br /> <br />- <br /> <br />5 <br />" <br />5' <br /> <br />- <br /> <br />1 <br />" <br />5' <br /> <br />- <br /> <br />7 <br />" <br />2' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />3' <br /> <br />- <br /> <br />3 <br />" <br />3' - 11"3' - 3"17' - 3" <br />2' - 7" <br />4 <br />01-A-04 <br />3 <br />01-A-04 <br />01-A-04 <br />1 <br />01-A-042 <br />Ex. Room #1 <br />Ex. Closet <br />Ex. Living Room <br />EX <br />. <br /> <br />5 <br />' <br />x <br />5 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX <br />. <br /> <br />5 <br />' <br />x <br />5 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX. 5'x5' SLIDING WIND.EX. 4'x5' SINGLE HUNG WIND. <br />EX. 3'x4' SINGLE HUNG WIND. <br />EX <br />. <br /> <br />4 <br />' <br />x <br />3 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX <br />. <br /> <br />5 <br />' <br />x <br />4 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX <br />. <br /> <br />5 <br />' <br />x <br />4 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX <br />. <br /> <br />6 <br />' <br />x <br />4 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX. 2'x5' SINGLE HUNG WIND. <br />EX. 2'x5' SINGLE HUNG WIND. <br />EX <br />. <br /> <br />5 <br />' <br />x <br />5 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX <br />. <br /> <br />5 <br />' <br />x <br />5 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX. 5'x5' SLIDING WIND.EX. 4'x5' SINGLE HUNG WIND. <br />EX. 3'x4' SINGLE HUNG WIND. <br />EX <br />. <br /> <br />4 <br />' <br />x <br />3 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX <br />. <br /> <br />5 <br />' <br />x <br />4 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX <br />. <br /> <br />5 <br />' <br />x <br />4 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX <br />. <br /> <br />6 <br />' <br />x <br />4 <br />' <br /> <br />S <br />L <br />I <br />D <br />I <br />N <br />G <br /> <br />W <br />I <br />N <br />D <br />. <br />EX. 2'x5' SINGLE HUNG WIND. <br />EX. 2'x5' SINGLE HUNG WIND. <br />13 <br />' <br /> <br />- <br /> <br />1 <br />" <br />9' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />12 <br />' <br /> <br />- <br /> <br />7 <br />" <br />1' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />10 <br />' <br /> <br />- <br /> <br />2 <br />" <br />51 <br />' <br /> <br />- <br /> <br />6 <br />" <br />5' - 0"11' - 0"14' - 3" <br />31' - 6" <br />12 <br />' <br /> <br />- <br /> <br />6 <br />" <br />14 <br />' <br /> <br />- <br /> <br />0 <br />" <br />13' - 3" <br />13' - 8" <br />N.Landing <br />6' x 3' <br />3' - 7" <br />3' - 6" <br />EX. SLIDING DOOR <br />3' <br /> <br />- <br /> <br />0 <br />" <br />3' - 6" <br />2' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />6' - 0" <br />3' - 0" <br />6' - 0"4' - 0" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />Landing 7 3/4" <br />max. below <br />threshold <br />PROVIDE 1 SQ. IN. OF VENTILATION PER 150 SQ. IN. OF ATTIC SPACE. <br />PROVIDE THAT 50% OF THE REQ. VENTILATION AREA IS PROVIDED BY <br />VENTILATORS IN THE UPPER PORTION OF THE ATTIC, (HIGH VENTING) AT 3'-0" <br />ABOVE EAVE VENT WITH THE BALANCE BEING PROVIDED BY EAVE VENTS, <br />(LOW VENTING) PER I.R.C. R806, (U.B.C. 1505.3). <br />ATTIC VENT CALCULATION ZONE 1 <br />VENTILATION REQUIRED: <br />SQ. FT. / 150 =SQ. FT.1150ATTIC AREA <br />X 144 =SQ. IN.144 <br />VENTILATION PROVIDED: <br />72 SQ. IN. EA. =1442 <br />SQ. IN.- <br />SQ. IN.O HAGIN <br />147 SQ. IN. EA. =-GABLE LOUVER VENT <br />TOTAL VENTILATION PROVIDED:SQ. IN.144 <br />EX. WALL TO REMAIN <br />EX. WALL TO BE DEMO <br />WALL SCHEDULE <br />NEW WALL <br />1-HR RATED/ SOUND <br />RATED (STC-50) <br />NEW FLAT ROOF <br />EX. ROOF FRAMING AND <br />FINISHES TO REMAIN <br />12 <br />' <br /> <br />- <br /> <br />0 <br />" <br />13 <br />' <br /> <br />- <br /> <br />6 <br />" <br />16' - 6"21' - 0" <br />4:12 <br />4:12 <br />4: <br />1 <br />2 <br />4: <br />1 <br />2 <br />4:12 <br />4: <br />1 <br />2 <br />4:12 <br />4:12 <br />4: <br />1 <br />2 <br />4: <br />1 <br />2 <br />54 <br />' <br /> <br />- <br /> <br />6 <br />" <br />37' - 6" <br />14 <br />' <br /> <br />- <br /> <br />0 <br />" <br />15 <br />' <br /> <br />- <br /> <br />0 <br />" <br />2% <br />EAVE <br />1' - 0" <br />EA <br />V <br />E <br />1' <br /> <br />- <br /> <br />0 <br />" <br />Dryer duct termination location <br />1 <br />01-A-03 <br />1 <br />01-A-03 <br />2 <br />01-A-03 <br />ARCHITECTURAL NOTES <br />1.PROVIDE 72" HIGH NON ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED <br />SHATTER RESISTANT MATERIALS FOR SHOWER ENCLOSURE. MATERIALS OTHER THAN <br />STRUCTURAL ELEMENTS TO BE MOISTURE RESISTANT. <br />2.SIZE OF SHOWER STALL TO COMPLY WITH CPC 412.7, 1024 SQ. IN. MINIMUM INTERIOR <br />AND ENCOMPASSING 30" CIRCLE. DOOR SHALL SWING TO THE OUTSIDE. <br />3.LOW FLOW TOILETS (1.28 GALLON/FLUSH) -SHOWERHEADS (2.0 GPM @ 80 PSI) <br />-FAUCETS (2.0 GPM @ 60 PSI) <br />4.PROVIDE INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE OR THE <br />THERMOSTATIC MIXING VALVE TYPE FOR SHOWERS AND TUB SHOWERS. <br />5.PROVIDE WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM OF <br />4" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS. <br />6.DUCTS SHALL BE SIZED PER CHAPTER 6 OF THE MECHANICAL CODE. <br />7.CLOTHES DRYER MOISTURE EXHAUST DUCT IS LIMITED TO 14 FEET WITH 2 ELBOWS <br />FROM THE CLOTHES DRYER TO POINT OF TERMINATION REDUCE THIS LENGTH BY 2 FEET <br />FOR EVERY ELBOW IN EXCESS OF 2. <br />8.UNIT SKYLIGHTS SHALL BE LABELED BY L.A CITY APPROVED LABELING AGENCY.SUCH <br />LABEL SHALL STATE THE APPROVED LABELING AGENCY NAME, PRODUCT DESIGNATION AND <br />PERFORMANCE GRADE RATING. <br />10. PROVIDE ULTRA LOW FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING <br />SHOWER HEADS AND TOILETS MUST BE UPDATED FOR LOW WATER CONSUMPTION. <br />11. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE FOOT CLEAR AND UNOBSTRUCTED <br />ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL BOXES, <br />TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE <br />LOCATION OF THE HOOK UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY <br />POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO <br />COMPLY MAY CAUSE CONSTRUCTION DELAYS AND OR ADDITIONAL EXPENSES. <br />12. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL GAS LINE <br />ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE <br />EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. <br />13. NEW OR REPLACEMENT WATER HEATERS SHALL BE STRAPPED TO THE WALL IN TWO <br />PLACES. ONE IN THE UPPER 1/3 OF THE TANK AND ONE IN THE LOWER 1/3 OF THE TANK. THE <br />LOWER POINT SHALL BE A MINIMUM OF 4" ABOVE THE CONTROLS.(P.C.510.5) LOW IN EXCESS <br />OF 2. <br />14.PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR <br />TO AN APPROVED SEWAGE DISPOSAL SYSTEM (R306.3). <br />15. KITCHEN SINK LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS AND <br />WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT AND COLD WATER AND <br />CONNECTED TO AN APPROVED WATER SUPPLY (R306.4). <br />16. BATHTUB AND SHOWER FLOORS, WALL ABOVE BATHTUBS WITH A SHOWERHEAD, AND <br />SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH <br />WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6' ABOVE THE FLOOR <br />(R307.2). <br />17. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH <br />NATURAL LIGHT BY MEANS OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE WITH SECTION <br />R303.1 OR SHALL BR PROVIDED WITH ARTIFICIAL LIGHT THAT IS ADEQUATE TO PROVIDE AN <br />AVERAGE ILLUMINATION OF 6' CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" <br />ABOVE THE FLOOR LEVEL. (R303.1) <br />18. A COPY OF THE EVALUATION REPORT AND/ OR CONDITIONS OF LISTING SHALL BE <br />MADE AVAILABLE AT THE JOB SITE. <br />19. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMP' OF 68°F AT A <br />POINT 3' ABOVE THE FLOOR AND 2' FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE <br />DESIGN TEMPERATURE. <br />20.PROTECTION OF WOOD AND WOOD BASED PRODUCTS FROM DECAY SHALL BE <br />PROVIDED IN THE LOCATIONS SPECIFIED PER SECTION R317.1 BY THE USE OF NATURALLY <br />DURABLE WOOD OR WOOD THAT IS PRESERVATIVE TREATED IN ACCORDANCE WITH AWPA <br />U1 FOR THE SPECIES, PRODUCT, PRESERVATIVE AND END USE.PRESERVATIVES SHALL BE <br />LISTED IN SECTION 4 OF AWPA U1. <br />21. PROVIDE ANTI-GRAFFITI FINISH WITHIN THE FIRST 9 FEET,MEASURED FROM GRADE,AT <br />EXTERIOR WALLS AND DOORS .EXCEPTION:MAINTENANCE OF BUILDING AFFIDAVIT IS <br />RECORDED BY THE OWNER TO COVENANT AND AGREE WITH THE CITY OF LOS ANGELES TO <br />REMOVE ANY GRAFFITI WITHIN 7 DAYS OF THE GRAFFITI BEING APPLIED.(6306) <br />UTILITY NOTES <br />1 ALL BRANCH CIRCUTS SUPPLYING RECEPTACLES SHALL BE PROTECTED BY A <br />LISTED ARC-FAULT CIRCUIT INTERRUPTER (AFCI) <br />2.ALL 120-VOLT, SINGLE PAHSE 15 AND 20 AMP BRANCH CIRCUIT SUPPLYING <br />OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, <br />PARLORS, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, <br />LAUNDRY ROOMS OR SIMILAR ROOMS OR AREAS SHALL BE AFCI PROTECTED BY ANY OF <br />THE MEANS DESCRIBED IN 210.12 (A)(1). AT KITCHEN COUNTER SPACE, RECEPTACLES <br />SHALL BE INDICATED AS COMBINATION AFCDI/GFCI. <br />3.TAMPER RESISTANT RECEPTACLES IN ALL AREAS SPECIFIED IN SECTION 210.52 <br />ALL 125-VOLT, 15 AND 20 AMP RECEPTACLES SHALL BE LISTED TAMPER RESISTANT <br />RECEPTACLES <br />4.NEW BOXES USED AT LUMINAIRES OR LAMPHOLDER OUTLETS IN A CEILING SHALL <br />BE REQUIRED TO SUPPORT A LUMINAIRIE WEIGHING A MINIMUM OF 50 LB. BOXES USED AT <br />LUMINARIE OUTLETS IN WALL SHALL BE DESIGNED FOR THE PURPOSE AND SHALL BE <br />MARKED ON THE INTERIOR INDICATING THE MAXIMUM WEIGHT OF LUMINAIRE PERMITTED, <br />IF OTHER THAN 50 LBS. OUTLET BOXES OR SYSTEMS USED AS THE SOLE SUPPORT OF <br />CEILING FANS SHALL BE LISTED AND MARKED BY THE MANUFACTURE AS SUITABLE FOR <br />THIS PURPOSE. (314.27 CEC) <br />5.ALL LEAD LUMINAIRES ARE REQUIRED TO BE CONTROLLED BY NATIONAL <br />ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) SSL-7A-COMPLIANT DIMMER UNLESS <br />THEY ARE CONTROLLED BY A VACANCY SENSOR OR AN OCCUPANCY SENSOR. THE <br />COMBINED USE OF NEMA SSL-7A-COMPLIANT DIMMER WITH LED LUMINAIRES CAN <br />ENSURE FLICKER FREE OPERATION WHEN THE LUMINAIRE IS DIMMED. (2019 RESIDENTIAL <br />COMPLIANCE MANUAL 6.3.1(G) <br />6.IN BATHROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THIS SPACES MUST BE <br />CONTROLLED BY AN OCCUPANT SENSOR OR A VACANCY SENSOR PROVIDING <br />AUTOMATIC-OFF FUNCTIONALITY. IF A OCCUPANT SENSOR IS INSTALLED, IT MUST BE <br />INITIALLY CONFIGURED TO MANUAL-ON OPERATION USING THE MANUAL CONTROL <br />REQUIRED UNDER SECTION 150.0(k)2C. <br />ADDITIONAL NOTES <br />1.PROVIDE A MINIMUM OF (2) 20 AMP SMALL APPLIANCE CIRCUITS FOR THE KITCHEN <br />COUNTER TOPS. SUCH CIRCUIT SHALL HAVE NO OTHER OUTLETS. LOADS SHALL BE <br />BALANCED. CEC 210-52(B) (2) <br />2.PROVIDE A MINIMUM OF (1) 20 AMP LAUNDRY BRANCH CIRCUIT. SUCH CIRCUIT <br />SHALL HAVE NO OTCOHER OUTLETS. CEC 210-23(A). <br />3.A MINIMUM OF (1) 20-AMP CIRCUIT FOR BATHROOM(S) OUTLET. SUCH CIRCUIT <br />SHALL HAVE NO OTHER OUTLETS. THIS CIRCUIT MAY SERVE MORE THAN ONE BATHROOM <br />CEC 210-23 <br />4.IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE <br />LUMINAIRE IN EACH OF THESE SPACES MUST BE CONTROLLED BY A VACANCY SENSOR. <br />5.OUTDOOR LIGHTING PERMANENTLY MOUNTED TO A RESIDENTIAL BUILDING, OR <br />TO OTHER BUILDING ON THE SAME LOT, MUST MEET THE REQUIREMENT IN ITEM <br />150.0(K)3AI (ON AND OFF SWITCH) AND THE REQUIREMENTS IN EITHER ITEM 150.0(K)3AII <br />(PHOTOCELL AND MOTION SENSOR) OR ITEM 150.0(K)3AIII (PHOTO CONTROL AND <br />AUTOMATIC TIME SWITCH CONTROL, ASTRONOMICAL TIME CLOCK, OR EMCS <br />6.ALL LIMINAIRES SHALL BE HIGH EFFICACY -PER SECTION 150.0(K)1A. <br />7.CIRCUIT SHALL HAVE NO OTHER OUTLETS. CEC 210-23(A). <br />ADDITIONAL NOTES: <br />1. HABITABLE SPACES SHALL HAVE CEILING HEIGHT OF NO LESS THAN 7'-6". KITCHENS, <br />LAUNDRY ROOM, CORRIDORS AND BATHROOMS SHALL HAVE CEILING HEIGHT NOT <br />LESS THAN 7'. <br />2. PROVIDE 1 ESCAPE WINDOW IN EACH BEDROOM MEETING ALL OF THE FOLLOWING: AN <br />OPENABLE AREA NOT LESS THAN 5.7 SQ.FT. MIN. CLEAR 24" HEIGHT AND 20" WIDTH <br />AND SILL NOT OVER 44" ABOVE FLOOR <br />3. SHOWER WALLS MUST BE FINISHED TO A HEIGHT OF 72" ABOVE DRAIN W/ MOISTURE <br />RESISTIVE TILE OR APPROVED EQUAL <br />4. MAX. FLOW RATE STANDARDS SET BY THE CALIFORNIA ENERGY COMMISION: WATER <br />CLOSETS 1.28 GPF, SHOWERHEADS 2.0 GPM, LAUNDRY FAUCETS 1.5 GPM, SINK <br />FAUCETS 1.5 GPM, AND KITCHEN FAUCETS 1.8 GPM <br />5. EXTERIOR WALLS WITHIN 3 FEET OF PROPERTY LINE (SPRINKLERS) OR 5 FEET OF <br />PROPERTY LINE (WITHOUT SPRINKLERS) REQUIRE 1-HOUR FIRE RATING FOR <br />EXPOSURE TO BOTH SIDES <br />6. PROJECTIONS: -PROHIBITED WITHIN 2 FEET OF PROPERTY LINE -1-HOUR FIRE <br />RATING ON THE UNDERSIDE WITHIN 3FT OF PROPERTY LINE (SPRINKLERS) -1-HOUR <br />FIRE RATING ON THE UNDERSIDE WITHIN 5FT OF PROPERTY LINE (WITHOUT <br />SPRINKLERS) <br />7. OPENINGS: -PROHIBITED WITHIN 3FT OF PROPERTY LINE -MAXIMUM 25% OF WALL <br />AREA WITHIN 5 FEET OF PROPERTY LINE (WITHOUT SPRINKLERS) <br />8. PENETRATIONS: -1-HOUR FIRE-RATED PENETRATIONS OF WALLS WITHIN 3FT OF <br />PROPERTY LINE (SPRINKLERS) -1-HOUR FIRE-RATED PENETRATIONS OF WALLS <br />WITHIN 5FT OF PROPERTY LINE (WITHOUT SPRINKLERS) <br />1/4" = 1'-0" <br />Proposed Floor Plan 11 <br />Project number <br />Date <br />Drawn by <br />Checked by <br />E-mail:skyaaconstruction@gmail.com <br />THIS DESIGN AND DRAWINGS, ARE <br />COPYRIGHT PROTECTED AND ARE <br />THE EXCLUSIVE PROPERTY OF AA SKY <br />CONSTRUCTION INC., THEY SHALL BE <br />NO USED, MODIFIED DUPLICATED IN <br />WHOLE OR IN ANY MANNER, NOR <br />ASSIGNED TO A THIRD PARTY WITHOUT <br />THE WRITTEN AUTHORIZATION <br />OF AA SKY CONSTRUCTION INC. <br />APPROVAL STAMP <br />OWNER <br />CONTACT PERSON <br />DESIGNER <br />AA SKY CONSTRUCTION INC. <br />2074 SILVERADO ST. <br />SAN MARCOS CA 92078 <br />LIC#1061749 <br />OFFICE 858 888 3752 <br />CELL 760 845 7697 <br />RAFAEL G LUJANO <br />E-MAIL: SKYAACONSTRUCTION@GMAIL.COM <br />CONSULTANTS <br />01-A-02 <br />PROPOSED FLOOR PLAN, <br />PROPOSED ROOF PLAN - <br />ADD <br />0001 <br />2201 HALLADAY ST. <br />STA. ANA, CA 92707 <br />01-24-2024 <br />Lucas <br />- <br />NEW 132 SQ.FT. ADD <br />TO BE GAMEROOM <br />RAFAEL LUJANO <br />2201 HALLADAY ST. STA. ANA, CA 92707 <br />skyaaconstruction@gmail.com <br />+17608457697 <br />RAFAEL LUJANO <br />2201 HALLADAY ST. STA. ANA, CA 92707 <br />skyaaconstruction@gmail.com <br />+17608457697 <br />1/4" = 1'-0" <br />Proposed Roof Plan 12 <br />No. Description Date <br />2201 S Halladay St <br />9/24/2024