My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2201 S Halladay St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Halladay St
>
2201 S Halladay St
>
2201 S Halladay St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:47:19 PM
Creation date
6/5/2025 7:36:52 AM
Metadata
Fields
Template:
Plan
Permit Number
101119327
Full Address
2201 S Halladay St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
138
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PROJECT : PAGE : <br />CLIENT : DESIGN BY : <br />JOB NO. : DATE : 06/26/24 REVIEW BY : <br />INPUT DATA <br />Exposure category (B, C or D)B <br />Importance factor I =1.00 Category II <br />Basic wind speed V =110 mph <br />Topographic factor Kzt =1 Flat <br />Building height to eave he =8 ft <br />Building height to ridge hr =13 ft <br />Effective area of components A =21.33333 ft2 <br />DESIGN SUMMARY <br />ANALYSIS <br />Velocity pressure <br />qh = 0.00256 Kh Kzt Kd V2 I =18.43 psf <br />where:qh = velocity pressure at mean roof height, h. <br />Kh = velocity pressure exposure coefficient evaluated at height, h,= 0.70 <br />Kd = wind directionality factor <br />h = mean roof height ft <br />p = qh [(G Cpf )-(G Cpi )] <br />where:p = pressure in appropriate zone <br />G Cp f = product of gust effect factor and external pressure coefficient <br />G Cp i = product of gust effect factor and internal pressure coefficient <br /> =0.18 or -0.18 <br />a = width of edge strips, MAX[ MIN(0.1B, 0.4h), 0.04B,3] =3.55 ft <br />Net Pressures (psf), Basic Load Cases Net Pressures (psf), Torsional Load Cases <br />15.73 0.00 15.73 <br />(+GCp i )(-GCp i )(+GCp i )(-GCp i )(+GCp i )(-GCp i ) <br />1 0.49 5.77 12.40 0.40 4.05 10.69 1T 0.49 1.44 3.10 <br />2 -0.69 -16.03 -9.40 -0.69 -16.03 -9.40 2T -0.69 -4.01 -2.35 <br />3 -0.45 -11.59 -4.95 -0.37 -10.14 -3.50 3T -0.45 -2.90 -1.24 <br />4 -0.39 -10.51 -3.87 -0.29 -8.66 -2.03 4T -0.39 -2.63 -0.97 <br />1E 0.75 10.43 17.07 0.61 7.93 14.56 0.00 <br />2E -1.07 -23.04 -16.40 -1.07 -23.04 -16.40 <br />3E -0.64 -15.20 -8.56 -0.53 -13.09 -6.45 p i p i <br />ENGINEERING <br />Surface <br />Roof angle q = <br />Net Pressure with <br />Surface <br />Roof angle q = <br />G Cp f <br />Net Pressure with <br />Surface <br />Roof angle q = <br />G Cp f <br />24-459 <br />2201 HALADAY STREET <br />Wind Analysis for Low-rise Building, Based on ASCE 7-16 / IBC 2024 / CBC 2022 <br />Roof angle q = <br />G Cp f <br />Net Pressure with <br />CASTILLO <br />Net Pressure withG Cp f <br />26 <br />2201 S Halladay St <br />9/24/2024
The URL can be used to link to this page
Your browser does not support the video tag.