www.hilti.com <br />Hilti PROFIS Engineering 3.0.89 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />HD3B - GL A <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />12/19/2023 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: HIT-HY 200 V3 + HAS-V-36 (ASTM F1554 Gr.36) 5/8 <br /> Item number: not available (element) / 2334276 HIT-HY 200-R V3 <br /> (adhesive) <br /> Effective embedment depth: hef,act = 12.500 in. (hef,limit = - in.) <br /> Material: ASTM F1554 Grade 36 <br /> Evaluation Service Report: ESR-4868 <br /> Issued I Valid: 11/1/2022 | 11/1/2024 <br /> Proof: Design Method ACI 318-19 / Chem <br /> Stand-off installation: <br /> Profile: <br /> Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 24.000 in., Temp. short/long: 32/32 °F <br /> Installation: hammer drilled hole, Installation condition: Dry <br /> Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present <br /> edge reinforcement: none or < No. 4 bar <br /> Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) <br /> Shear load: yes (17.10.6.3 (c)) <br />Geometry [in.] & Loading [lb, in.lb] <br />31 of 100 <br />1327 S Grand Ave <br />12/12/2024