Laserfiche WebLink
LAG SCREW ANALYSIS <br />Loads <br />Wind Pressures qz =-44.45 psf <br />Solar Panel Load QD =3 psf <br />Panel Length l =5.650 ft <br />Panel Width b 3.7167 ft <br />Attachment Spacing s =5.33 ft <br />Portrait <br />Tributary Area At =15.06 ft2 <br />Wind Load PW = qz * At =-669 lbs <br />Dead Load PD = QD * At =45.172 lbs <br />Uplift Pa = 0.6 PD + 0.6 Pw =-374 lbs <br />Landscape <br />Tributary Area At = b * s =9.9049 ft2 <br />Wind Load PW = qz * At =-440 lbs <br />Dead Load PD = QD * At =29.715 lbs <br />Uplift Pa = 0.6 PD + 0.6 Pw =-246 lbs <br />Lag Screw <br />Specific Gravity of Lumber SG =0.50 (Douglas Fir-Larch) <br />Diameter of Lag Screw D =5/16 in <br />Withdraw Design /in 1800*SG3/2*D3/4 =266 lbs/in <br />Depth of Embedment lp =2.50 in <br />Total Nominal Withdrawal Value W = W * l p =665 lbs <br />Load Duration Factor CD =1.6 <br />Withdrawal Design Value W' = W * C D =1064 lbs <br />Demand Capacity Ratio DCR = Pa / W'=0.35 < 1 OK <br />219 E St Gertrude <br />Pl-201834578/7/2024