My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
219 E St Gertrude Pl - Plan
PBA
>
Building
>
ProjectDox
>
S
>
St Gertrude Pl
>
219 E St Gertrude Pl
>
219 E St Gertrude Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 7:22:36 AM
Creation date
6/6/2025 7:22:21 AM
Metadata
Fields
Template:
Plan
Permit Number
20183457
20183892
101120147
101120683
Full Address
219 E St Gertrude Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV SYSTEM <br />AS INDICATED <br />February 9, 2024 <br />REYNA HERNANDEZ <br />219 E SAINT GERTRUDE PL <br />SANTA ANA, CA 92707 <br />Clean Energy Solutions Inc. <br />Address: <br />1055 West 7th Street <br />33rd Floor, Los Angeles, <br />CA 90017 <br />Phone Number: <br />(800) 994 1134 <br />Lic# 998787 <br />Class C-10 <br />CONTRACTOR <br />Designed By: Inter Solar Cad <br />www.intersolarcad.com <br />PV SYSTEM DC SIZE 8.40KW <br />PV SYSTEM AC SIZE 7.77KW <br />JB <br /> <br />B <br />O <br />X <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />CEC 690.13(B) <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />CEC 110.27(C) <br />DC <br /> <br />D <br />i <br />s <br />c <br />o <br />n <br />n <br />e <br />c <br />t <br />CEC 690.13(B) <br />In <br />v <br />e <br />r <br />t <br />e <br />r <br /> <br />/ <br /> <br />P <br />V <br /> <br />L <br />o <br />a <br />d <br />WARNING <br />THE DISCONNECTION OF THE <br />GROUNDING CONDUCTOR(S) <br />MAY RESULT IN OVERVOLTAGE <br />ON THE EQUIPMENT <br />CEC 690.31(E) <br />CEC 690.54 <br />AC <br /> <br />D <br />i <br />s <br />c <br />o <br />n <br />n <br />e <br />c <br />t <br />CEC 690.54 <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />CEC 690.13(B) <br />PM <br /> <br />M <br />E <br />T <br />E <br />R <br />Ma <br />i <br />n <br />/ <br />S <br />u <br />b <br /> <br />P <br />a <br />n <br />e <br />l <br />CEC 690.54 <br />CEC 690.13 (E), CEC 705.12(B)(C-D) & CEC 690.59 <br />CEC 690.15 (B) & CEC 690.33(D)(2) <br />CEC 690.13(B) <br />SINGLE 120-VOLT SUPPLY <br />DO NOT CONNECT <br />MULTIWIRE BRANCH CIRCUIT! <br />CEC 710.15(C) <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />CEC 110.27(C) <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />CEC 690.13(B) <br />CEC 705.12 (B)(3)(2) <br />LABELING REQUIREMENTS FOR ARTICLE 690 <br />CEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether <br />in the open (off) or closed (on) position and be permanently marked “PV SYSTEM <br />DISCONNECT” or equivalent. Additional markings shall be permitted based upon <br />the specific system configuration. <br />CEC 690.13(E) Type of Disconnect. The PV system disconnecting means shall <br />simultaneously disconnect the PV system conductors that are not solidly grounded <br />from all conductors of other wiring systems. The PV system disconnecting means or <br />its remote operating device or the enclosure providing access to the disconnecting <br />means shall be capable of being locked in accordance with 110.25. <br />CEC 690.15(B) An isolating device shall not be required to have an interrupting <br />rating. Where an isolating device is not rated for interrupting the circuit current, it shall <br />be marked "Do Not Disconnect Under Load" or "Not for Current Interrupting." An <br />isolating device shall not be required to simultaneously disconnect all current-carrying <br />conductors of a circuit. <br />CEC 690.31(B)(1) PV system dc circuit conductors shall be identified at all <br />termination, connection, and splice points by color coding, marking tape, tagging, or <br />other approved means. <br />CEC 690.31(D)(2) Unless located and arranged so the purpose is evident, the following wiring <br />methods and enclosures that contain PV system dc circuit conductors shall be marked with the <br />wording PHOTOVOLTAIC POWER SOURCE or SOLAR PV DC CIRCUIT by means of <br />permanently affixed labels or other approved permanent marking. <br />CEC 690.31(D)(2) PV system dc circuit labels shall appear on every section of the wiring <br />system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between <br />labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). <br />Labels required in this section shall be suitable for the environment where they are installed. <br />CEC 690.31(E) Solidly-grounded bipolar PV systems shall be clearly marked with a <br />permanent, legible warning notice indicating that the disconnection of the grounded <br />conductor(s) may result in overvoltage on the equipment. <br />CEC 690.33(D)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a <br />tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting”. <br />CEC 690.6 Alternating-current (AC) modules and systems: The PV source circuit, conductors, <br />and inverters shall be considered as internal components of an ac module or ac module <br />system. <br />CEC 690.53 A permanent readily visible label indicating the highest <br />maximum dc voltage in a PV system, calculated in accordance with 690.7, <br />shall be provided by the installer. <br />CEC 690.54 All interactive system(s) points of interconnection with other <br />sources shall be marked at an accessible location at the disconnecting <br />means as a power source and with the rated ac output current and the <br />nominal operating ac voltage. <br />CEC 690.55 The PV system output circuit conductors shall be marked to <br />indicate polarity where connected to energy storage systems. <br />CEC 690.56(A) Plaques or directories shall be installed in accordance with <br />705.10. <br />CEC 690.56(C)(2) A rapid shutdown switch shall have a label located on <br />or no more than 1 meter (3 ft) from the switch. <br />CEC 690.59 PV systems connected to other sources shall be installed in <br />accordance with Parts I and II of Article 705 and Article 712. <br />SOLAR ELECTRIC <br />PV PANELS <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH ON THE <br />"OFF" POSITION TO <br />SHUTDOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN ARRAY <br />CFC 1205.4.1(1) & CEC 690.56(C) <br />CEC 690.56(C)(2) <br />CEC 690.31(D)(2) <br />CEC 690.31(D)(2)CO <br />N <br />D <br />U <br />I <br />T <br />RATED AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />PHOTOVOLTAIC AC DISCONNECT <br />DC DISCONNECT <br />PHOTOVOLTAIC <br />WARNING <br />RATED AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />PHOTOVOLTAIC AC DISCONNECT <br />RATED AC OPERATING CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br />PHOTOVOLTAIC AC DISCONNECT MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT WARNING <br />CAUTION <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE. <br />WARNING <br />DO NOT DISCONNECT <br />UNDER LOAD <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />WARNING: PHOTOVOLTAIC <br />POWER SOURCE <br />WARNING <br />PHOTOVOLTAIC POWER SOURCE <br />DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW <br />FOR SOLAR PHOTOVOLTAIC SYSTEMS THAT SHUT <br />DOWN THE ARRAY AND THE CONDUCTORS LEAVING <br />THE ARRAY, A LABEL SHALL BE PROVIDED. THE <br />FIRST TWO LINES OF THE LABEL SHALL BE <br />UPPERCASE CHARACTERS WITH A MINIMUM <br />HEIGHT OF 3/8 INCH (10 MM) IN BLACK ON A <br />YELLOW BACKGROUND. THE REMAINING <br />CHARACTERS SHALL BE UPPERCASE WITH A <br />MINIMUM HEIGHT OF 3/16 INCH (5 MM) IN BLACK ON <br />A WHITE BACKGROUND. [CFC 1205.4.1(1)] <br />240 Vac <br />240 Vac <br />240 Vac <br />CEC 690.13(B) <br />AC DISCONNECT <br />PHOTOVOLTAIC <br />WARNING <br />ELECTRICAL SHOCK HAZARD <br />TERMINALS ON THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />CEC 690.13(B) <br />CEC 705.10 <br />CAUTION <br />MULTIPLE SOURCES OF POWER <br />CEC 705.10 <br />CAUTION <br />MULTIPLE SOURCES OF POWER <br />CEC 690.53 <br />OF PV SYSTEM <br />MAXIMUM DC VOLTAGE <br />CEC 690.53 <br />MAXIMUM SYSTEM VOLTAGE <br />RATED SHORT CIRCUIT CURRENT <br />N/AMAX RATED AC OPERATING VOLTAGE <br />N/ARATED AC OPERATING VOLTAGE <br />MAX RATED AC OPERATING CURRENT <br />RATED AC OPERATING CURRENT <br />N/A <br />N/A <br />N/A <br />N/A <br />CAUTION <br />N <br /> 0° <br />S <br /> 180° <br />E <br /> 90° <br />W <br /> 270° <br />POWER TO THIS BUILDING IS ALSO SUPPLIED <br />FROM THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN: <br />CEC 705.10 & CEC 690.56(B) <br />Permanent directory or plaque providing location of service disconnecting means and <br />photovoltaic system disconnecting means, if not located at the same location. (Plaques shall <br />be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a <br />contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the <br />required location using an approved method that is suitable to withstand the environment to which it <br />is exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesion <br />requirements of Underwriters Laboratories marking and labeling system 969(UL969). <br />Plaques will have red background & white lettering. <br />25.0 A <br />25.0 A <br />25.0 A <br />CODE REQUIRED <br />SIGNAGE <br />PV 2.0 <br />PV SYSTEM DISCONNECT <br />FOR UTILITY OPERATION <br />SOLAR INVERTER <br />SOLAREDGE ENERGY <br />BANK BATTERY <br />SERVICE POINT & <br />UTILITY METERING <br />E ST GERTRUDE PL <br />SOLAR ARRAY <br />ON THE ROOF <br />SOLAR ARRAY <br />ON THE ROOF <br />219 E St Gertrude <br />Pl-201834578/7/2024
The URL can be used to link to this page
Your browser does not support the video tag.