My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1895 & 1995 S Standard Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Standard Ave
>
1895 S Standard Ave
>
1895 & 1995 S Standard Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 7:22:38 AM
Creation date
6/6/2025 7:22:21 AM
Metadata
Fields
Template:
Plan
Permit Number
20184604
20184605
101121774
101121775
Full Address
1895 S Standard Ave
1995 S Standard Ave
Text box
ID:
1
Creator:
Import Agent
Created:
6/6/2025 7:22 AM
Modified:
6/4/2025 1:49 PM
Text:
11.07.2024
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
8' - 0"8' - 0"8' - 0" <br />PV SUB 1 COMBINER <br />PANEL 300LB TYP <br />4' - 0" <br />INVERTER #3 <br />180lbs TYP <br />INVERTER #2 <br />251lbs TYP <br />MIN. CLR. <br />3' - 2" <br />INVERTER #1 <br />251lbs TYP <br />INVERTER #4 <br />180lbs TYP <br />INVERTER #5 <br />180lbs TYP <br />(2) 1/4" LAG SCREW <br />W/ 3-1/8" MIN EFFECTIVE <br />EMBED INTO (E) FRAMING <br />7 <br />PV-6 <br />PV SUB 2 COMBINER <br />PANEL 150LB TYP <br />PS 200 STRUT <br />7 <br />PV-6 <br />5' <br /> <br />- <br /> <br />8 <br />" <br />TYP <br />8' - 0" <br />1-5/8" x 1-5/8" <br />x12GA. POWER STRUT <br />PS 200 2T3 HORIZ. TYP. <br />POWER STRUT <br />PS735 DOUBLE <br />STRUT HORIZ TYP <br />(E) 2X FRAMING <br />AT INVERTER RACK 1 <br />(AS REQUIRED) <br />PS 200 VERT <br />PV SUB 1 <br />COMBINER <br />PANEL 300LB <br />TYP <br />INVERTER #3 <br />180lbs TYP <br />INVERTER #2 <br />251lbs TYP <br />INVERTER #1 <br />251lbs TYP <br />INVERTER #4 <br />180lbs TYP <br />INVERTER #5 <br />180lbs TYP <br />PV SUB 2 <br />COMBINER <br />PANEL 150LB <br />TYP <br />5' - 8" <br />PV-6 <br />8 <br />2' - 6" <br />45.0° <br />3/8" DIA. ASTM A307 THRU <br />BOLT W/NUT & WASHER, TYP.PS 200 W/ ADJ. PS 200 SEE <br />DET. 3 FOR MORE INFO. <br />(2) 1/4" LAG SCREW <br />W/ 3-1/8" MIN <br />EFFECTIVE EMBED <br />PS 200 <br />PS 7781 W/(4) 3/8" ASTM <br />A307 THRU BOLTS <br />(E) 2x FRAMING <br />POWER STRUT PS735 HORIZ TYP <br />PS 200 2T3 <br />PS 7781 W/(4) 3/8" ASTM <br />A307 THRU BOLTS <br />PS 607 W/(4) 3/8" <br />ASTM A307 THRU <br />BOLTS <br />PS 135 ROD COUPLING <br />PS 146 3/8" THREADED ROD <br />8' - 0" <br />PYRAMID BLOCK <br />SUPPORT <br />2' - 0" <br />3 <br />PV-6 <br />INVERTER'S <br />WT=251 LBS EA <br />INVERTER <br />MOUNTING PLATE <br />INVERTER'S <br />WT=180 LBS EA <br />(2) 1/4" LAG SCREW <br />W/ 3-1/8" MIN <br />EFFECTIVE EMBED <br />PS 200 <br />PS 7781 W/(4) 3/8" ASTM <br />A307 THRU BOLTS <br />(E) 2x FRAMING <br />PS 200 2T3 <br />PS 135 ROD COUPLING <br />PS 146 3/8" THREADED ROD <br />ANCHOR PRODUCTS ANCHOR W/ TPO <br />FLASHING TO MATCH (E) ROOF <br />(E) ROOF DECK <br />PYRAMID BLOCK <br />SUPPORT W/ <br />CHANNEL NUT <br />3/8" NUT TO LOCK COUPLING <br />3/8" NUT, LOCK WASHER & <br />FENDER WASHER (TYP) <br />3/8" NUT TO LOCK COUPLING <br />1' - 0" <br />THIS DOCUMENT CONTAINS PROPRIETARY <br />INFORMATION. REPRODUCTION, DISCLOSURE, OR <br />USE WITHOUT SPECIFIC WRITTEN <br />AUTHORIZATION OF CONTRACTOR <br />IS STRICTLY FORBIDDEN. <br />DA <br />T <br />E <br />: <br />X_____________________________ <br />SKYBRIDGE <br />RENEWABLES LLC <br />127 MAYFAIR ALISO VIEJO, <br />CA 92656 <br />TEL: (949) 424-9320 <br />11 <br />/ <br />6 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />1 <br />0 <br />: <br />4 <br />8 <br />: <br />2 <br />6 <br /> <br />A <br />M <br />Ut <br />i <br />l <br />i <br />t <br />y <br /> <br />C <br />u <br />s <br />t <br />o <br />m <br />e <br />r <br /> <br />N <br />a <br />m <br />e <br />: <br /> <br />P <br />r <br />o <br />l <br />o <br />g <br />is <br /> <br />L <br />o <br />g <br />i <br />s <br />t <br />i <br />c <br /> <br />S <br />e <br />r <br />v <br /> <br />I <br />n <br />c <br /> <br /> <br /> <br />- <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />D <br />i <br />s <br />t <br />r <br />i <br />b <br />u <br />t <br />i <br />o <br />n <br /> <br />C <br />e <br />n <br />t <br />e <br />r <br /> <br />1 <br />19 <br />9 <br />5 <br /> <br />S <br /> <br />S <br />t <br />a <br />n <br />d <br />a <br />r <br />d <br /> <br />A <br />v <br />e <br /> <br />S <br />a <br />n <br />t <br />a <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br /> <br />& <br /> <br />1 <br />8 <br />9 <br />5 <br />S <br />S <br />t <br />a <br />n <br />d <br />a <br />r <br />d <br /> <br />A <br />v <br />e <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />PV-6 <br />St <br />r <br />u <br />c <br />t <br />u <br />r <br />a <br />l <br /> <br />D <br />e <br />t <br />a <br />i <br />l <br />s <br />SKYBRIDGE RENEWABLES LLC <br />C10 - 1112028 <br />10/31/2025 <br />3/4" = 1'-0"1 Equipment Attachment - Plan View <br />3/4" = 1'-0"3 Equipment Attachment - Elevation <br />3/4" = 1'-0"7 <br />Equipment Attachment - Section (Inverter <br />Only) <br />3" = 1'-0"8 Equipment Attachment - Vert Support <br />No. <br />Description <br />Date <br />1895 & 1995 S Standard <br />Ave1/7/2025
The URL can be used to link to this page
Your browser does not support the video tag.