Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />412 <br />=3x10 <br />=3x10 <br />=2.5x4 <br />=3x4 <br />=3x8 <br />=M18AHS 7x14 = 4x6 <br />= 3x6 <br />=M18AHS 7x14 <br />=2.5x4 <br />=4x8 = 7x10 <br />=4x8 <br />=3x4 <br />=2.5x4 =3x12 <br />9 <br />81 <br />33 16 34 15 35 36 14 37 13 38 39 12 40 41 11 42 10 43 <br />32213122 2 7 <br />4 25 26 27 28 5 24 29 30 233 6 <br />0-0-5 <br />18-11-9 <br />0-0-5 <br />8-0-0 <br />1-0-0 <br />27-11-4 <br />3-3-9 <br />18-11-4 <br />3-3-9 <br />11-3-9 <br />3-11-5 <br />3-11-5 <br />3-11-5 <br />26-11-4 <br />4-4-3 <br />15-7-11 <br />4-0-6 <br />22-11-15 <br />4-0-6 <br />7-11-11 <br />3-0-1 <br />6-11-6 <br />3-0-1 <br />22-11-15 <br />3-11-5 <br />3-11-5 <br />3-11-5 <br />26-11-4 <br />4-4-3 <br />19-11-14 <br />4-4-3 <br />15-7-11 <br />4-4-3 <br />11-3-9 <br />3- <br />3 <br />- <br />9 <br />0- <br />3 <br />- <br />1 <br />5 <br />0- <br />3 <br />- <br />9 <br />2- <br />8 <br />- <br />4 <br /> <br />2- <br />8 <br />- <br />4 <br />0- <br />3 <br />- <br />9 <br />2- <br />1 <br />1 <br />- <br />1 <br />3 <br />Scale = 1:50.6 <br />Plate Offsets (X, Y): [1:0-10-1,0-0-2], [1:0-7-10,0-3-3], [3:0-4-10,0-3-0], [6:0-4-8,Edge] <br />Loading (psf) Spacing 2-0-0 CSI DEFL in (loc) l/defl L/d PLATES GRIP <br />TCLL (roof)20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) -0.18 12-14 >999 360 MT20 220/195 <br />TCDL 18.0 Lumber DOL 1.25 BC 0.50 Vert(CT) -0.67 12-14 >480 240 M18AHS 169/162 <br />BCLL 0.0 * Rep Stress Incr NO WB 0.36 Horz(CT) 0.15 8 n/a n/a <br />BCDL 10.0 Code IBC2021/TPI2014 Matrix-MS Wind(LL) 0.19 12-14 >999 240 Weight: 310 lb FT = 20% <br />LUMBER <br />TOP CHORD 2X4 DF No.1&Btr G *Except* 3-6:2X8 DF SS <br />G <br />BOT CHORD 2X6 DF SS G <br />WEBS 2X4 DF Std G <br />BRACING <br />TOP CHORD Structural wood sheathing directly applied or <br />4-8-15 oc purlins, except <br />2-0-0 oc purlins (6-0-0 max.): 3-6. <br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc <br />bracing. <br />REACTIONS (size) 1= Mechanical, 8=0-5-8 <br />Max Horiz 1=-43 (LC 10) <br />Max Uplift 1=-408 (LC 12), 8=-412 (LC 12) <br />Max Grav 1=2800 (LC 1), 8=3053 (LC 1) <br />FORCES (lb) - Maximum Compression/Maximum <br />Tension <br />TOP CHORD 1-2=-7946/1400, 2-3=-7840/1316, <br />3-4=-7440/1273, 4-5=-10127/1554, <br />5-6=-7755/1187, 6-7=-8170/1226, <br />7-8=-8399/1264, 8-9=0/25 <br />BOT CHORD 1-16=-1261/7508, 15-16=-1261/7508, <br />14-15=-1410/10127, 12-14=-1384/10190, <br />11-12=-1384/10190, 10-11=-1136/7937, <br />8-10=-1136/7937 <br />WEBS 2-16=-85/46, 2-15=-247/343, <br />3-15=-151/1766, 6-11=-138/1796, <br />7-11=-284/235, 7-10=-16/115, <br />4-15=-3091/382, 4-14=0/463, 5-14=-149/19, <br />5-12=0/391, 5-11=-2810/444 <br />NOTES <br />1) 2-ply truss to be connected together with 10d <br />(0.131"x3") nails as follows: <br />Top chords connected as follows: 2x4 - 1 row at 0-9-0 <br />oc, 2x8 - 2 rows staggered at 0-9-0 oc. <br />Bottom chords connected as follows: 2x6 - 2 rows <br />staggered at 0-9-0 oc. <br />Web connected as follows: 2x4 - 1 row at 0-9-0 oc. <br />2) All loads are considered equally applied to all plies, <br />except if noted as front (F) or back (B) face in the LOAD <br />CASE(S) section. Ply to ply connections have been <br />provided to distribute only loads noted as (F) or (B), <br />unless otherwise indicated. <br />3) Unbalanced roof live loads have been considered for <br />this design. <br />4) Wind: ASCE 7-16; Vult=130mph (3-second gust) <br />Vasd=103mph; TCDL=9.0psf; BCDL=6.0psf; h=25ft; <br />B=45ft; L=27ft; eave=4ft; Cat. II; Exp C; Enclosed; <br />MWFRS (directional) and C-C Exterior(2E) 0-0-12 to <br />3-0-12, Interior (1) 3-0-12 to 6-11-6, Exterior(2R) 6-11-6 <br />to 11-3-9, Interior (1) 11-3-9 to 19-11-14, Exterior(2R) <br />19-11-14 to 24-2-13, Interior (1) 24-2-13 to 27-11-13 <br />zone; cantilever left and right exposed ; end vertical left <br />and right exposed;C-C for members and forces & <br />MWFRS for reactions shown; Lumber DOL=1.60 plate <br />grip DOL=1.60 <br />5) Provide adequate drainage to prevent water ponding. <br />6) All plates are MT20 plates unless otherwise indicated. <br />7) This truss has been designed for a 10.0 psf bottom <br />chord live load nonconcurrent with any other live loads. <br />8) * This truss has been designed for a live load of 20.0psf <br />on the bottom chord in all areas where a rectangle <br />3-06-00 tall by 2-00-00 wide will fit between the bottom <br />chord and any other members. <br />9) A plate rating reduction of 20% has been applied for the <br />green lumber members. <br />10) Bearings are assumed to be: , Joint 8 DF SS . <br />11) Refer to girder(s) for truss to truss connections. <br />12) Provide mechanical connection (by others) of truss to <br />bearing plate capable of withstanding 408 lb uplift at joint <br />1 and 412 lb uplift at joint 8. <br />13) Graphical purlin representation does not depict the size <br />or the orientation of the purlin along the top and/or <br />bottom chord. <br />14) Hanger(s) or other connection device(s) shall be <br />provided sufficient to support concentrated load(s) 585 <br />lb down and 297 lb up at 7-11-12, 198 lb down and 139 <br />lb up at 10-0-12, 198 lb down and 143 lb up at 12-0-12, <br />198 lb down and 143 lb up at 13-5-10, 198 lb down and <br />143 lb up at 14-10-8, and 198 lb down and 139 lb up at <br />16-10-8, and 664 lb down and 263 lb up at 18-11-8 on <br />top chord, and 87 lb down and 24 lb up at 2-0-12, 16 lb <br />down at 4-0-12, 17 lb down and 9 lb up at 6-0-12, 111 <br />lb down at 8-0-12, 112 lb down at 10-0-12, 112 lb down <br />at 12-0-12, 112 lb down at 13-5-10, 112 lb down at <br />14-10-8, 112 lb down at 16-10-8, 111 lb down at <br />18-10-8, 97 lb down at 20-10-8, and 84 lb down at <br />22-10-8, and 174 lb down and 26 lb up at 24-10-8 on <br />bottom chord. The design/selection of such connection <br />device(s) is the responsibility of others. <br />LOAD CASE(S) Standard <br />1) Dead + Roof Live (balanced): Lumber Increase=1.25, <br />Plate Increase=1.25 <br />Uniform Loads (lb/ft) <br />Vert: 1-3=-76, 3-6=-76, 6-9=-76, 1-8=-20 <br />Concentrated Loads (lb) <br />Job Truss Truss Type Qty Ply 250065 1512 N Baker ADU <br />R87778788 <br />A California Girder 1 2250065-A Job Reference (optional) <br />World International Truss, Victorville, CA - 92395, Run: 8.73 S Feb 19 2025 Print: 8.730 S Feb 19 2025 MiTek Industries, Inc. Mon Apr 21 10:48:21 Page: 1 <br />ID:oeAYToKnHAPVRxcZ5uwrA8zmaJU-RfC?PsB70Hq3NSgPqnL8w3uITXbGKWrCDoi7J4zJC?f <br />Continued on page 2 <br />April 21,2025 <br />1512 N Baker St & Unit # 2-Truss <br />Drawings <br />5/8/2025