My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1512 N Baker St & Unit # 2-Truss Drawings - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Baker St
>
1512 N Baker St Unit# 2
>
1512 N Baker St & Unit # 2-Truss Drawings - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 7:22:38 AM
Creation date
6/6/2025 7:22:21 AM
Metadata
Fields
Template:
Plan
Permit Number
101120504
Full Address
1512 N Baker St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(E) GARAGE TO BE <br />REMOVED <br />(E) MAIN HOUSE <br />1512 N BAKER ST <br />SANTA ANA, 92706 <br />2 BD + 1 BA <br />786 SF <br />9' - 10" <br />16 <br />' <br /> <br />- <br /> <br />6 <br />" <br /> <br />1 <br />7 <br />' <br /> <br />- <br /> <br />9 <br />" <br />25 <br />' <br /> <br />- <br /> <br />9 <br />" <br />3 <br />0 <br />' <br /> <br />- <br /> <br />0 <br />" <br />98 <br />' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />(E) POWER POLE <br />(E <br />) <br /> <br />C <br />U <br />R <br />B <br /> <br />C <br />U <br />T <br /> <br />A <br />N <br />D <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br />(E) LANDSCAPE AND HARDSCAPE TO REMAIN <br />TOTAL SITE : 7,733 SF <br />(E) HOUSE: 786 SF <br />ZONING: R1 <br />EASEMENTS: 5' REAR PUE <br />(E) 6' SOLID MASONRY WALL <br />GRASS <br />SAND <br />15 <br />4 <br />' <br /> <br />- <br /> <br />8 <br />" <br />5' - 0" <br />5' - 3 1/2" <br />(E) ELECTRICAL PANEL <br />(E) TANKLESS WATER HEATER <br />50' - 0" <br />EA <br />S <br />E <br />M <br />E <br />N <br />T <br />5' <br /> <br />- <br /> <br />0 <br />" <br /> <br />P <br />U <br />E <br />LIVING ROOM BEDROOM <br />BEDROOMBATHKITCHEN <br />1-CAR GARAGE <br />5' - 0"26' - 11 1/4"13' - 0 3/4"5' - 0" <br />4' <br /> <br />- <br /> <br />0 <br />" <br /> <br />1 <br />4 <br />' <br /> <br />- <br /> <br />9 <br />" <br /> <br />1 <br />2 <br />' <br /> <br />- <br /> <br />4 <br /> <br />3 <br />/ <br />4 <br />" <br /> <br />2 <br />6 <br />' <br /> <br />- <br /> <br />2 <br />" <br />1,408 SF OPEN SPACE (REQ'D = 1,200 SF) <br />(N) ACCESSORY DWELLING UNIT <br />1512 N BAKER ST UNIT #2 <br />SANTA ANA, 92706 <br />3 BD + 2 BA <br />1,000 SF <br />(N) 100 AMP ELECTRICAL PANEL <br />(N) CONDENSING UNIT ON <br />CONCRETE PAD <br />(E) POWER POLE <br />IRRIGATION: (E) POP-UP SPRINKLER <br />(E) 6' SOLID MASONRY WALL <br />(E <br />) <br /> <br />C <br />U <br />R <br />B <br /> <br />C <br />U <br />T <br /> <br />A <br />N <br />D <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br />(E) LANDSCAPE AND HARDSCAPE <br />TO REMAIN <br />CONCRETE PATHWAY <br />GRASS <br />SAND <br />CONCRETE PATHWAY CO <br />N <br />C <br />R <br />E <br />T <br />E <br /> <br />P <br />A <br />T <br />H <br />W <br />A <br />Y <br />(N) RECESSED TANKLESS WATER <br />HEATER. PROVIDE DEDICATED <br />125V, 20A GFCI RECEPTACLE <br />CONNECTED TO PANEL WITH A <br />120/240V 3-CONDUCTOR 10 AWG <br />COPPER BRANCH CIRCUIT, WITHIN <br />3' OF THE WATER HEATER AND <br />ACCESSIBLE TO THE WATER <br />HEATER. <br />TOTAL SITE : 7,733 SF <br />(E) HOUSE: 786 SF <br />(N) ADU: 1,000 SF <br />(E) MAIN HOUSE <br />1512 N BAKER ST <br />SANTA ANA, 92706 <br />2 BD + 1 BA <br />786 SF <br />V.I.F. <br />APPROX. 15' - 1 1/2" <br />PORCH <br />(E) ELECTRICAL PANEL. <br />UPGRADE TO 200 AMP <br />(E) TANKLESS WATER HEATER <br />50' - 0" <br />15 <br />4 <br />' <br /> <br />- <br /> <br />8 <br />" <br />REFER TO CIVIL DRAWINGS FOR SAND BAG LAYOUT <br />EA <br />S <br />E <br />M <br />E <br />N <br />T <br />5' <br /> <br />- <br /> <br />0 <br />" <br /> <br />P <br />U <br />E <br />NOTES: <br />• LOT SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION.THE GRADE SHALL FALL NOT FEWER <br />THAN 6 INCHES WITHIN THE FIRST 10 FEET. IMPERVIOUS SURFACE MAY BE MIN 2%SLOPE. DRAINS OR SWALES <br />SHALL BE PROVIDED WHERE 10' DISTANCE CAN'T BE PROVIDED. <br />• THE ADU SHALL HAVE ADDRESS NUMBERS/UNIT IDENTIFICAT ION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE <br />AND VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY AND AT THE ENTRY DOOR IF THE ENTRY DOOR <br />IS NOT VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. NUMBERS AND LETTERS SHALL CONTRAST <br />WITH BACKGROUND, BE NUMBERS OR ALPHABETICAL LETTERS AND BE A MINIMUM OF 4”HIGH WITH A MINIMUM <br />STROKE OF ½” <br />1' - 8" <br />FUTURE HEAT PUMP WATER <br />HEATER LOCATION WITH BOTH <br />ENDS OF UNUSED CONDUCTOR <br />LABELED AS "SPARE" AND <br />ELECTRICALLY ISOLATED, A <br />RESERVED SINGLE POLE CIRCUIT <br />BREAKER SPACE IN THE PANEL <br />WITH WORDS "FUTURE 240V USE", <br />AND A CONDENSATE DRAIN NO <br />MORE THAN 2" HIGHER THAN BASE <br />OF INSTALLED WATER HEATER AND <br />ALLOWS NATURAL DRAINING <br />WITHOUT PUMP ASSISTANCE <br />2.5'x2.5' <br />1/ <br />2 <br />" <br /> <br />W <br />A <br />T <br />E <br />R <br />WA <br />T <br />E <br />R <br /> <br />M <br />E <br />T <br />E <br />R <br />GAS METER <br />1 <br />1 <br />/ <br />2 <br />" <br /> <br />G <br />A <br />S <br />3" <br /> <br />M <br />I <br />N <br /> <br />S <br />E <br />W <br />E <br />R <br />, <br /> <br />V <br />. <br />I <br />. <br />F <br />ELECTRICAL LINE <br />WA <br />T <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />SE <br />W <br />E <br />R <br /> <br />T <br />O <br /> <br />( <br />E <br />) <br /> <br />L <br />A <br />T <br />E <br />R <br />A <br />L <br /> <br />M <br />I <br />N <br /> <br />1 <br />/ <br />4 <br />" <br /> <br />P <br />E <br />R <br /> <br />F <br />O <br />O <br />T <br />GA <br />S <br /> <br />T <br />O <br /> <br />( <br />E <br />) <br /> <br />G <br />A <br />S <br /> <br />M <br />E <br />T <br />E <br />R <br />4" / 12" <br />4" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />4" / 12" <br />TOTAL SITE COVERAGE: 1,000 + 786 = 1,786 SF <br />ALLOWED COVERAGE: 35% = 7,733 (0.35) + 800 (SEC41-194.3E) = 3,506 SF <br />4" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />4" / 12" <br />TY <br />P <br />. <br />1' <br /> <br />- <br /> <br />0 <br />" <br />4" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />1' - 0" <br />ROOFING MATERIAL: <br />CLASS A -ASPHALT SHINGLE <br />OWENS CORNING, TRU DEFINITION <br />DURATION ESTATE GRAY OR EQUAL <br />UL 790 CLASS A FIRE RESISTANCE <br />ICC-ES AC438 <br />INSTALLATION OF ROOFING SHALL BE <br />IN ACCORDNACE WITH <br />MANUFACTURER'S SPECIFICATIONS <br />ATTIC VENT REQUIREMENT" <br />ATTIC SF = 1,000 SF <br />REQUIRED = 1000 X 1/150 = 6.67 SF OR 960 SQ IN <br />PROVIDED = (5) 14x14 ROOF VENTS <br />VENT OPENINGS SHALL BE PROVIDED WITH <br />CORROSION RESISTANT WIRE MESH WITH 1/16" MIN <br />TO 1/4" MAX OPENINGS. A MIN OF 1" AIRSPACE <br />MUST BE MAINTAINED BETWEEN THE INSULATION <br />AND THE ROOF SHEATHING AT THE LOCATIONS OF <br />THE VENTS <br />4' - 0" <br />1 HR UNDERSIDE <br />1' - 0" <br />1 HR UNDERSIDE <br />1' - 0" <br />4' - 0" <br />BE <br />N <br />J <br />A <br />M <br />I <br />N <br /> <br />T <br />A <br />L <br />P <br />O <br />S <br />REVISIONS <br />SH <br />E <br />E <br />T <br /> <br />N <br />A <br />M <br />E <br />: <br />3438 W. 76th ST <br />LOS ANGELES, CA 90043 <br />10 <br />/ <br />2 <br />8 <br />/ <br />2 <br />0 <br />2 <br />4 <br /> <br />1 <br />1 <br />: <br />2 <br />9 <br />: <br />4 <br />5 <br /> <br />A <br />M <br />C: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />a <br />k <br />o <br />n <br />g <br />\ <br />D <br />r <br />o <br />p <br />b <br />o <br />x <br />\ <br />a <br />s <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br />\ <br />1 <br />5 <br />1 <br />2 <br /> <br />N <br /> <br />B <br />a <br />k <br />e <br />r <br /> <br />S <br />t <br /> ( <br />J <br />i <br />m <br />m <br />y <br /> <br />A <br />D <br />U <br />) <br />\ <br />1 <br />5 <br />1 <br />2 <br />B <br />a <br />k <br />e <br />r <br />A <br />D <br />U <br />_ <br />R <br />2 <br />0 <br />2 <br />2 <br />_ <br />2 <br />4 <br />0 <br />5 <br />0 <br />9 <br />. <br />r <br />v <br />t <br />BA <br />K <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br /> <br />N <br />E <br />W <br /> <br />A <br />D <br />U <br />BU <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br />SE <br />T <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />& <br /> <br />P <br />R <br />O <br />P <br />O <br />S <br />E <br />D <br />SI <br />T <br />E <br /> <br />P <br />L <br />A <br />N <br />S <br />A-1.1 <br />Is <br />s <br />u <br />e <br /> <br />D <br />a <br />t <br />e <br />: <br /> <br />0 <br />5 <br />/ <br />0 <br />9 <br />/ <br />2 <br />0 <br />2 <br />4 <br />15 <br />1 <br />2 <br /> <br />N <br /> <br />B <br />A <br />K <br />E <br />R <br /> <br />S <br />T <br /> <br />U <br />N <br />I <br />T <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />15 <br />1 <br />2 <br /> <br />N <br /> <br />B <br />A <br />K <br />E <br />R <br /> <br />S <br />T <br /> <br />U <br />N <br />I <br />T <br /> <br /># <br />2 <br />. <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />SCALE:1/8" = 1'-0"A-1.1 <br />1 EXISTING SITE PLAN <br />SCALE:1/8" = 1'-0"A-1.1 <br />2 PROPOSED SITE PLAN <br />SCALE:1/8" = 1'-0"A-1.1 <br />3 PROPOSED ROOF PLAN <br />NO <br />R <br />T <br />H <br />NO <br />R <br />T <br />H <br />NO <br />R <br />T <br />H <br />1 <br />1 <br />1 1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1512 N Baker St & Unit # <br />21/6/2025
The URL can be used to link to this page
Your browser does not support the video tag.