My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2130 E 4th St - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
2130 E Fourth St
>
2130 E 4th St - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 3:31:24 AM
Creation date
6/6/2025 7:22:22 AM
Metadata
Fields
Template:
Plan
Permit Number
20183018
30147360
40139177
101119571
Full Address
2130 E Fourth St
Street Number
2130
Street Direction
E
Street Name
Fourth
Street Suffix
St
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
211
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />EARTH STRATA GEOTECHNICAL SERVICES 11 March 30, 2023 Project Number 234812-10A <br />utility easements, under footings, sidewalks, driveways and building floor slabs, as well as within or adjacent to any slopes. Backfill should be placed in approximately 6 to 8 inch maximum loose lifts and then mechanically compacted with a hydro-hammer, rolling with a sheepsfoot, pneumatic tampers, or similar equipment. The utility trenches should be tested by the project geotechnical engineer or their representative to verify minimum compaction requirements are obtained. In order to minimize the penetration of moisture below building slabs, all utility trenches should be backfilled with compacted fill, lean concrete or concrete slurry where they undercut the perimeter foundation. Utility trenches that are proposed parallel to any building footings (interior and/or exterior trenches), should not be located within a 1:1 (h:v) plane projected downward from the outside bottom edge of the footing. <br />SEISMIC DESIGN CONSIDERATIONS <br />Ground Motions Structures are required to be designed and constructed to resist the effects of seismic ground motions as provided in the 2022 California Building Code Section 1613. The design is dependent on the site class, occupancy category I, II, III, or IV, mapped spectral accelerations for short periods (Ss), and mapped spectral acceleration for a 1-second period (S1). In order for structural design to comply with the 2022 CBC, the USGS “US Seismic Design Maps” online tool was used to compile spectral accelerations for the subject property based on data and maps jointly compiled by the United States Geological Survey (USGS) and the California Geological Survey (CGS). The data found in the following table is based on the Maximum Considered Earthquake (MCE) with 5% damped ground motions having a 2% probability of being exceeded in 50 years (2,475 year return period). The seismic design coefficients were determined by a combination of the site class, mapped spectral accelerations, and occupancy category. The following seismic design coefficients should be implemented during design of the proposed structures. Summaries of the Seismic Hazard Deaggregation graphs and test data are presented in Appendix D. <br />2022 CBC FACTOR (ASCE 7-22) Site Location ˚ (North)˚(West) <br />s 1 <br />ms 1.76 g <br />m1 1.17 g 1.17 g 0.78 g <br />2130 E 4th St <br />2/11/2025
The URL can be used to link to this page
Your browser does not support the video tag.