Laserfiche WebLink
<br />EARTH STRATA GEOTECHNICAL SERVICES 14 March 30, 2023 Project Number 234812-10A <br />The above lateral resistance values are based on footings for an entire structure being placed directly against compacted fill. <br />Structural Setbacks and Building Clearance Structural setbacks are required per the 2022 California Building Code (CBC). Additional structural setbacks are not required due to geologic or geotechnical conditions within the site. Improvements constructed in close proximity to natural or properly engineered and compacted slopes can, over time, be affected by natural processes including gravity forces, weathering, and long term secondary settlement. As a result, the CBC requires that buildings and structures be setback or footings deepened to resist the influence of these processes. For structures that are planned near ascending and descending slopes, the footings should be embedded to satisfy the requirements presented in the CBC, Section 1808.7 as illustrated in the following Foundation Clearances from Slopes diagram. <br /> <br />FOUNDATION CLEARANCES FROM SLOPES <br /> <br /> <br />2022 <br />2130 E 4th St <br />2/11/2025