4 <br />2'-0" X 4'-0" <br />ACOUSTICAL TILE <br />SEE SPECS. TYP. <br />2X4 RECESSED FLUORESCENT LIGHT <br />FIXTURES. SEE ELECTRICAL <br />DRAWINGS <br />LATERAL SUPPORT POINT <br />SEE STRUCTURAL DRAWINGS <br />WHERE FIXTURE ROW FALLS <br />BETWEEN MAIN RUNNER, USE 4'-0" <br />LG. MAIN AT 4'-0" O.C. AS CROSS <br />TEE <br />HVAC-AIR DIFFUSERS, WITH <br />APPROVED CLIPS OR WIRES AS <br />REQUIRED BY CITY STANDARDS <br />TYP. <br />2-SAFETY WIRES AT OPPOSITE <br />DIAGONAL CORNERS EACH FIXTURE <br />MIN. OR AS REQUIRED BY LOCAL <br />AUTHORITIES AND SHALL PAINTED IN <br />RED. <br />12 GA. GALV. STEEL <br />LAY-IN ACCOUSTICAL <br />CEILING TILES <br />DIFFUSER LENS <br />LIGHT FIXTURE <br />NO. 12 ON MAIN RUNNER WITHIN 3" OF 4 <br />CORNERS @ LIGHT FIXTURE. <br />WIRE HANGER AT <br />4'-0" O.C. EACH WAY <br />4 <br />3 <br />1.12 GA. (MIN.) HANGER WIRES MAY BE USED FOR UP TO AND INCLUDING 4'-0" X <br />4'-0" GRID SPACING ALONG MAIN RUNNERS SPLICES WILL NOT BE PERMITTED <br />IN ANY HANGER WIRES UNLESS SPECIFICALLY APPROVED BY DSA/SSS. <br />2.PROVIDE 12 GA. HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS <br />RUNNERS WITHIN 8" FROM THE SUPPORT OR WITHIN 1/4 OF THE LENGTH OF <br />THE END TEE, WHICHEVER IS AT LEAST FOR THE PERMIETER OF THE CEILING <br />AREA. <br />3.PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT <br />OBSTRUCTIONS TO MAIN HANGER SPACING. PROVIDE ADDITIONAL HANGERS, <br />STRUTS OR BRACES AS REQUIRED AT ALL CEILING BREAKS, SOFFITS, OR <br />DISCONTINUOUS AREAS. HANGER WIRES THAT ARE MORE THAN 1 IN 6 OUT <br />OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. <br />4.CEILING GRID MEMBERS MAY BE ATTACHED TO NOT MORE THAN 2 ADJACENT <br />WALLS. CEILING GRID MEMBERS SHOULD BE AT LEAST 1/2 INCH FREE OF <br />OTHER WALLS. IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM <br />RUNNERS, ONE END OF MAIN AND CROSS RUNNER SHOULD BE FREE AND A <br />MINIMUM OF 1/2 INCH CLEAR OF WALL. <br />5.AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS <br />ARE NOT CONNECTED TO THE ADJACENT WALL. PROVIDE INTERCONNECTION <br />BETWEEN RUNNERS AT THE FREE END TO PREVENT LATERAL SPREADING. A <br />METAL STRUT OR A 16 GA. WIRE WITH A POSITIVE MECHANICAL CONNECTION <br />TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR DISTANCE <br />FROM THE WALL TO THE FIRST PARALLELE RUNNER IS 12" OR LESS. THIS <br />INTERLOCK IS NOT REQUIRED. <br />6.PROVIDE SETS OF FOUR 12 GA. SPLAYED BRACINS WIRES ORIENTED 90 <br />DEGREES FROM EACH OTHER AT NOT MORE THAN 12'-0" X 12'-0" ON CENTER. <br />7.PROVIDE BRACING WIRES AT LOCATION NOT MORE THAN 6"0" FROM EACH <br />PERIMETER WALL AND AT THE EDGE OF VERTICAL CEILING OFFSETS. <br />8.NOTE: WIRE TURNS MADE BY MACHINE WHERE BOTH STRANDS HAVE BEEN <br />DEFORMED OR BENT IN WRAPPING CAN WAIVE THE 1-1/2" REQUIREMENT. <br />BUT IN THE NUMBER OF TURNS SHOULD BE MAINTAINED, AND BE AS TIGHT <br />AS POSSIBLE. <br />9.SEPARATE ALL CEILING HANGING AND BRACING WIRES AT LEAST 6 INCHES <br />FROM ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC. IT IS ACCEPTABLE TO <br />ATTACH LIGHTWEIGHT ITEMS, SUCH AS SINGLE ELECTRICAL CONDUIT NOT <br />EXCEEDING 3/4" NOMINAL. DIAMETER TO HANGER WIRES USING <br />CONNECTORS ACCEPTABLE TO DSA/SSS. <br />10.HVAC DUCTWORK, ELECTRICAL DISTRIBUTION, TELEPHONE SERVICES, <br />COMPUTER CABLE DISTRIBUTION, AND OTHER SERVICES NORMALLY FOUND <br />IN A CEILING SPACE SHALL BE INDEPENDENTLY SUPPORTED AND <br />APPROPRIATELY BRACED TO ELIMINATE ANY LATERAL FORCE ON THE <br />CEILING MEMBRANE OR BRACING ELEMENTS. <br />11.WHEN DRILL-IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN <br />REINFORCING CONCREETE FOR HANGING WIRES, 1 OUT OF 10 MUST BE <br />FIELD TESTED FOR 200 POUNDS OF TENSION. WHEN DRILLED-IN CONCRETE <br />ANCHORS ARE USED FOR BRACING WIRES. 1 OUT OF 2 MUST BE FIELD <br />TESTED FOR 440 LBS. OF TENSION. SHOT-IN ANCHORS IN CONCRETE ARE <br />NOT PERMITTED FOR BRACING WIRES. IF ANY SHOT-IN OR DRILLED ANCHOR <br />FAILS, ALL ADJACENT ANCHORS MUST BE TESTED. DRILLED-IN OR SHOT-IN <br />ANCHOR MUST BE TESTED. DRILLED -IN OR SHOT-IN ANCHIRS REQURIE <br />SPECIAL DSA/SSS APPROVAL WHEN USED IN PRESTRESSED CONCRETE. <br />12.ATTACH ALL LIGHT FIXTURES TO THE CEILING GRID RUNNERS TO RESIST A <br />HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. <br />13.ALL RECESSED LIGHTING FIXTURES HAVING A NOMINAL END DIMENSION OR <br />24" OR GREATER SHALL BE POSITIVELEY ATTACHED TO THE CEILING GRID <br />RUNNER(S) AT THE END OF THE FIXTURE WITH TWO #8 SELF TAPPING TEK <br />SCREWS. EACH SCREW SHALL BE LOCATED WITHIN 3 OF THE SIDE OF THE <br />FIXTURE AND ATTACHED THROUGH THE BULB OF THE CEILING GRID <br />RUNNER(S). LIGHT FIXTURES HAVING LESS THAN A NOMINAL 24" END <br />DIMENSION SHALL BE ATTACHED WITH ONE #8 SELF TAPPING TEK SCREW AT <br />THE CENTER OF EACH END OF THE FIXTURE. ATTACHED TO THE BULB OF <br />THE CEILING GRIS RUNNER(S). ALL ATTACHMENTS SHALL BE CAPABLE OF <br />LATERALLY SUPPORTING THE WEIGHT OF THE FIXTURE. ALL FIXTURES <br />REGARDLESS OF WEIGHT OR SIZE SHALL HAVE INTERLOCKING CEILING GRID <br />RUNNER(S) ON ALL 4 SIDES OF THE FIXTURE. <br />14.CEILING-MOUNTED AIR TERMINALS OR SERVICES SHALL BE POSITVELY <br />ATTACHED TO THE CEILING SUSPENSION MAIN RUNNERS OR TO CROSS <br />RUNNERS WITH THE SAME CARRYING CAPACITY AS THE MAIN RUNNER. <br />ATTACHED TO THE FIXTURE OR TERMINAL AND TO THE STRUCTURE ABOVE <br />AIR TERMINALS WITH A NOMINAL DIMENSION OF 24" OR LESS SHALL BE <br />POSITIVELY ATTACHED TO THE CEILING GRID RUNNER(S) ON AT LEAST TWO <br />OPPOSING SIDES WITH ONE #8 SELF TAPPING TEK SCREW ON EACH SIDE. <br />EACH SCREW SHALL BE LOCATED IN THE CENTER OF HTE AIR TERMINAL AND <br />SHALL BE ATACHED THROUGH THE BULB OF HTE CEILING GRID RUNNER(S). <br />AIR TERMINALS IN EXCESS OF 24" IN LENGTH SHALL BE ATTACHED WITH TWO <br />#8 SELF TAPPING TEK SCREWS ON EACH END OF DIFFUSER ATTACHED TO <br />THE BULB OF THE CEILING DRID RUNNER(S). ALL ATTACHMENTS SHALL BE <br />CAPABLE OF LATERALLY SUPPORTING THE WEIGHT OF THE AIR TERMINAL. <br />ALL AIR TERMINALS REGARDLESS OF WEIGHT OR SIZE SHALL HAVE <br />INTERLOCKING CEILING GRID RUNNER(S) ON ALL 4 SIDES OF THE AIR <br />TERMINAL. <br />15.FLUSH OR RECESSED LIGHT FIXTURES AND AIR TERMINALS OR SERVICES <br />WEIGHING LESS THAN 56 LBS. MAY BE SUPPORTED DIRECTLY ON THE <br />RUNNERS OF A HEAVY DUTY GRID SYSTEM BUT, IN ADDITION, THEY MUST <br />HAVE A MINIMUM OF TWO 12 GA. SLACK SAFETY WIRES ATTACHED TO THE <br />FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE STRUCTURE <br />ABOVE. ALL 4'-0" X 4'-0" LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES <br />AT EACH CORNER. ALL FLUSH OR RECESSED LIGHT FIXTURES AND AIR <br />TERMINALS OR SERVICES WEIGHING 56 LBS. OR MORE MUST BE <br />INDEPENDANTLY SUPPORTED BY NOT LESS THAN 4 TAUT 12 GA. WIRES EACH <br />ATTACHED TO THE FIXTURE AND TO THE STRUCTURE ABOVE REGARDLESS <br />OF THE TYPE OF CEILING GRID SYSTEM USED. THE 4 TAUT 12 GA. WIRES <br />INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE MUST BE <br />CAPABLE OF SUPPORTING 4 TIMES THE WEIGHT OF THE UNIT. <br />16.ALL FIXTURES AND AIR TERMINALS OR SERVICES SUPPORTED ON <br />INTERMEDIATE DUTY GRID SYSTEMS MUST BE INDEPENDENTLY SUPPORTED <br />BY NOT LESS THAN 4 TAUT 12 GA. WIRE EACH. <br />17.SUPPORT SURFACE MOUNTED LIGHT FIXTURES BY AT LEAST TWO POSITIVE <br />DEVICES WHICH SURROUND THE CEILING RUNNER AND WHICH ARE EACH <br />SUPPORTED FROM THE STRUCTURE ABOVE BY A 12 GA. WIRE. SPRING CLIPS <br />OR CLAMPS THAT CONNECT ONLY TO THE RUNNER ARE NOT ACCEPTABLE. <br />18.PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES AE 8 FEET OR <br />LONGER. <br />19.SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE <br />STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH <br />EACH PENDANT HANGER AND CAPABLE OF SUPPORTING 4 TIMES THE <br />WEIGHT OF THE FIXTURE. SPECIAL DETAILS ARE NECESSARY FOR THIS <br />CONDITION AT THE CEILING GRID. <br />20.CLASSIFICATION OF CEILING GRID IS HEAVY DUTY. <br />21.SUSPENDED CEILING SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE <br />WITH ASTM C635, ASTM C636 AND SEC. 13.5.6.2. ASCE 7-05. <br /> <br />22.ANCHORS FOR WALL ANGLES: <br />A. AT METAL STUD WALL 1-1/8" TYPE "S" BUGLE HEAD <br />DRYWALL SCREW AT 16" O.C. <br />B. AT MASONRY WALL: 1/4" DIA. 1-1/2" LONG TAPCON <br />ANCHORSCREW AT 16" O.C. ICBO No. 3370. <br />23.CONTRACTOR SHALL COORDINATE THE WORK OF ALL TRADES INVOLVED IN <br />THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING <br />CEILING SUSPENSION SYSTEMS, ETC., NECESSARY TO MAINTAIN THE <br />FINISHED CEILING HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. <br />24.PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT <br />TO PARTITION SURFACES, FREE FROM CURVES, BREAKS OR OTHER <br />IRREGULARITIES. <br />24.LIGHT FIXTURES, EXIT SIGNS AND OTHER CEILING ELEMENTS SHALL BE <br />LOCATED IN CENTER OF INDIVIDUAL CEILING TILE U.O.N OR AS DIRECTED BY <br />ARCHITECT. <br />25.PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM <br />MAINTENANCE VERIFY MANUFACTURER RECOMMENDATIONS. <br />26.ELECTRICAL CONTRACTOR TO PROVIDE ALL SWITCHES, DIMMERS, & PLATES, <br />AS REQUIRED BY DESIGN, LOCATED 44" A.F.F. 6" FROM DOOR FRAME. U.O.N. <br />MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GANGED TOGETHER, AND <br />FURNISHED WITH ONE COVER PLATE. <br />27.THE REFLECTED CEILING PLAN INDICATES THE LOCATION OF CEILING TYPES, <br />CEILING FIXTURES, LIGHT SWITCHES AND ASSOCIATED ITEMS. REFER TO <br />ENGINEERING DRAWINGS (LIGHT PLAN) FOR CIRCUITING, WIRING LAY-OUT, <br />AND ADDITIONAL INFORMATION. <br />28.ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS <br />ABOVE CEILING ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING, FIRE <br />PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS, BY THE CONTRACTED <br />ENGINEERS. <br />29.CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICT OF LIGHT FIXTURE <br />LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC.. PRIOR TO INSTALLATION. <br />30.VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL PLUMBING, MECHANICAL <br />DUCTS, STRUCTURAL ELEMENTS AND ANY AND ALL OTHER APPLICABLE <br />ITEMS. INSTALL NEW PLUMBING, MECHANICAL FANS, DUCTS, CONDUITS, AND <br />OTHER RELATED ITEMS SO AS TO NOT CONFLICT WITH LIGHTS AND ANY <br />UNIQUE FIELD CONDITIONS. <br />31.FURNISH AND INSTALL UNDERWRITERS LABORATORY, INC. (UL) LABELED <br />DEVICES THROUGHOUT. <br />32.PROVIDE AND INSTALL EMERGENCY LIGHTING PER ADA/TITLE 24 <br />REQUIREMENTS. <br />ASCE STANDARD 7-10 - SECTION 13.5.6 SUSPENDED CEILINGS <br />33.A HEAVY DUTY T-BAR GRID SYSTEM SHALL BE USED - SEE ITEM NO. 20 THIS <br />SHEET FOR ADDITIONAL INFORMATION. <br />34.THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE <br />NOT LESS THAN 2.0 INCHES. WHERE PERIMETER SUPPORTING CLIPS ARE <br />USED, THEY SHALL BE QUALIFIED IN ACCORDANCE WITH APPROVED TEST <br />CRITERIA. IN EACH ORTHOGONAL HORIZONTAL DIRECTION, ONE END OF THE <br />CEILING GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE OR CHANNEL. <br />THE OTHER END IN EACH HORIZONTAL DIRECTION SHALL HAVE A 0.75 INCH <br />CLEARANCE FROM THE WALL AND SHALL REST UPON AND BE FREE TO SLIDE <br />ON A CLOSURE ANGLE OR CHANNEL. <br />35.NOT USED <br />36.FOR CEILING AREAS EXCEEDING 2,500 SF, A SEISMIC SEPARATION JOINT OR <br />FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT <br />EXCEEDING 2,500 SF EACH WITH A RATIO OF THE LONG TO SHORT <br />DIMENSION LESS THAN OR EQUAL TO 4, SHALL BE PROVIDED UNLESS <br />STRUCTURAL ANALYSES ARE PERFORMED OF THE CEILING BRACING <br />SYSTEM FOR THE PRESCRIBED SEISMIC FORCES THAT DEMONSTRATE <br />CEILING SYSTEM PENETRATIONS AND CLOSURE ANGLES PROVIDE <br />SUFFICIENT CLEARANCE TO ACCOMMODATE THE ANTICIPATED LATERAL <br />DISPLACEMENT. EACH AREA SHALL BE PROVIDED WITH CLOSURE ANGLES <br />OR CHANNELS IN ACCORDANCE WITH SECTION 13.5.6.2.2.a AND HORIZONTAL <br />RESTRAINTS OR BRACING. <br />37.EXCEPT WHERE RIGID BRACES ARE USED TO LIMIT LATERAL DEFLECTIONS, <br />SPRINKLER HEADS AND OTHER PENETRATIONS SHALL HAVE A 2" OVERSIZE <br />RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE <br />MOVEMENT OF AT LEAST 1" IN ALL DIRECTIONS. ALTERNATIVELY, A SWING <br />JOINT THAT CAN ACCOMODATE 1" OF CEILING MOVEMENT IN ALL <br />HORIZONTAL DIRECTIONS IS PERMITTED TO BE PROVIDED AT THE TOP OF <br />THE SPRINKLER HEAD EXTENSION. <br />38.CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE <br />BRACING. <br />39.CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED <br />INDEPENDENTLY OF THE CEILING. <br />40.SUSPENDED CEILINGS SHALL BE SUBJECT TO THE SPECIAL INSPECTION <br />REQUIREMENTS OF SECTION 11A.1.3.9 OF THIS STANDARD <br />DROP-IN LIGHT FIXTURESUSPENDED ACOUSTICAL TILE AND T-BAR CEILING SYSTEM <br />SUSPENDED CEILING NOTES <br />USE USG - DONN BRAND SUSPENSION <br />CEILING SYSTEMS HEAVY DUTY - <br />ESR-1222 <br />3' MAX <br />SCALE: NONE SCALE: NONE <br />CEILING DETAIL <br />SCALE: 3"=1'-0"1 <br />10 <br />° <br />- <br />4 <br />5 <br />° <br />8" MAX. <br />(TO THE WALL OR <br />END OF THE RUNNER) <br />6'-0" MAX. <br />ACOUSTIC TILE <br />CROSS RUNNER <br />MAIN RUNNER <br />WALL FINISH SURFACE <br />INSTALL COMPRESSION STRUT @ 12'-0" EA. <br />DIRECTION OR EVERY 144 S.F. OF CEILING AREA <br />FIELD CUT PERIMETER CEILING <br />TILES TO MATCH TEGULAR <br />UNCUT EDGES (WHERE OCCURS) <br />12 GA. WIRE HANGERS AT 4'-0" O.C. MAX. ALONG MAIN <br />RUNNERS. WHEN WIRES ARE OUT-OF-PLUMB (1H:6V), <br />PROVIDE COUNTER-SLOPING WIRES. STRUTS & WIRES <br />SHALL BE AT THE SAME LOCATION AS ONE ASSEMBLY. <br />LATERAL SUPPORT: 4 #12 WIRES SPLAYED IN FOUR DIRECTIONS 90° APART - <br />CONNECTED TO RUNNERS & TO STRUCTURE ABOVE. PLACE LATERAL <br />SUPPORTS @ 12'-0" O.C. IN EA. DIRECTION. <br />NOTE: <br />FOR ATTACHMENT TO <br />STRUCTURE ABOVE, SEE <br />STRUCTURAL DRAWINGS. <br />NOTES: <br />1.PROVIDE WALL ANGLE HORIZONTAL LEG. FIRST TILE SHALL MAINTAIN 3/4" CLEAR FROM FINISHED <br />WALL SURFACE. <br />2.SUSPENDED CEILING SYSTEM SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH ICC <br />ESR #1308, ASTM C635, ASTM C636, AND ASTM E580 SECTION 5. (ASCE 7-16, SECTION 13.5.6.2.2) <br />2.1.CROSS-RUNNERS SHALL HAVE A LOAD CAPACITY OF AT LEAST 16lbs. PER LINEAR FOOT <br />(VERIFY EXACT CRITERIA PER SELECTED PRODUCT & MANUFACTURER). <br />2.2.WHERE OBSTRUCTIONS PRECLUDE DIRECT SUSPENSION, A TRAPEZE OR EQUIVALENT <br />DEVICE SHALL BE PROVIDED. <br />3.PROVIDE SPECIAL INSPECTION AS REQUIRED BY ICC ESR APPROVAL REPORT. <br />4.LIGHTING FIXTURES AND AIR DIFFUSERS REQUIREMENTS: <br />4.1.LIGHT FIXTURES WEIGHING LESS THAN 10 POUNDS SHALL HAVE ONE 12 GAUGE HANGER <br />WIRE CONNECTED FROM THE FIXTURE TO THE STRUCTURE ABOVE AND SHALL BE ATTACHED <br />TO THE CEILING GRID WITH AT LEAST 2 FASTENERS (WHICH SHALL HAVE A MINIMUM FORCE <br />CAPACITY OF 100% OF THE WEIGHT OF THE FIXTURE ACTING IN ANY DIRECTION). <br />4.2.LIGHT FIXTURES WEIGHING MORE THAN 10 POUNDS, BUT LESS THAN 56 POUNDS, SHALL HAVE <br />THREE 12 GAUGE WIRES ATTACHED AT THE CORNERS OF THE LIGHT FIXTURE TO THE <br />STRUCTURE ABOVE. THESE WIRES MAY BE SLACK. <br />4.3.LIGHT FIXTURES WEIGHING MORE THAN 56 POUNDS, SHALL BE SUPPORTED DIRECTLY FROM <br />THE STRUCTURE ABOVE, WITH APPROVED HANGERS. <br />4.4.TANDEM FIXTURES MAY UTILIZE COMMON WIRES. <br />4.5.AIR TERMINALS WEIGHING LESS THAN 20 POUNDS SHALL BE ATTACHED TO THE CEILING GRID <br />(MAIN OR CROSS RUNNERS AND BOTH SHALL HAVE THE SAME CARRYING CAPACITY). <br />4.6.AIR TERMINALS WEIGHING MORE THAN 10 POUNDS, BUT LESS THAN 56 POUNDS, SHALL HAVE <br />TWO 12 GAUGE WIRES ATTACHED TO THE TERMINAL AND TO THE STRUCTURE ABOVE. THESE <br />WIRES MAY BE SLACK. <br />4.7.AIR TERMINALS WEIGHING MORE THAN 56 POUNDS, SHALL BE SUPPORTED DIRECTLY FROM <br />THE STRUCTURE ABOVE, WITH APPROVED HANGERS. <br />CONCEALED SPRINKLER HEAD <br />(WHERE OCCURS) PAINTED TO <br />MATCH ADJACENT CEILING. <br />TYP. FIRE SPRINKLER HEAD LAYOUT <br />SCALE: NOT TO SCALE <br />NOTE: <br />SPRINKLER HEADS AND OTHER <br />PENETRATIONS SHALL HAVE 2" OVERSIZE <br />RING, SLEEVE OR ADAPTOR THROUGH THE <br />CEILING TO ALLOW FOR FREE MOVEMENT OF <br />AT LEAST 1" IN ALL HORIZONTAL DIRECTIONS. <br />2" <br />MAX. <br />2" <br />MAX. <br />WALL <br />ANGLE <br />MOLDING <br />ATTACHED/TIGHT WALL <br />UNATTACHED / CLEARANCE WALL <br />8" MAX. <br />8" MAX. <br />MAIN BEAM OR <br />CROSS TEE <br />WALL <br />WALL <br />SEISMIC CLIP <br />WALL ANGLE <br />MOLDING <br />TIGHT SCREW <br />MAIN BEAM OR <br />CROSS TEE <br />SEISMIC CEILING DETAIL <br />SCALE: 3"=1'-0"2 <br />7/8" <br />7/8" <br />3/4" <br />NOTES: <br />1.PER ICC ESR #1308, 7/8" WALL <br />ANGLE MOLDING IS ALLOWED <br />(USE BERC-2 CLIP OR EQUAL). <br />2.WALL ANGLE MOLDING SHALL <br />BE SECURED TO ALL WALLS <br />WITH SELF-PIERCING SHEET <br />METAL SCREWS. <br />3.THE CEILING GRID SHALL BE <br />ATTACHED TO THE WALL <br />ANGLE ON 2 ADJACENT SIDES <br />AND SHALL BE FREE TO MOVE <br />3/4" ON THE OTHER SIDES . <br />SUSPENDED CEILING <br />DETAILS <br />A803 <br />CLIENT: <br />SUBMITTAL <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />B <br />S <br />B <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />, <br /> <br />i <br />n <br />c <br />. <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />a <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />DATEREVISION <br />SHEET TITLE <br />SHEET NO. <br />08.08.2023PLANNING SUBMITTAL <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />21 <br />3 <br />0 <br /> <br />E <br />. <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br /> <br /># <br />2 <br />0 <br />0 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />- <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br /> <br />T <br />I <br />CM220584.00 <br />21 <br />3 <br />0 <br /> <br />E <br />. <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />CL <br />I <br />E <br />N <br />T <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />1ST PC SUBMITTAL - BUILDING <br />PLAN CHECK RESUBMITTAL <br />02.08.2024 <br />PLAN CHECK RESUBMITTAL 09.09.2024 <br />970 W. 190TH. ST., SUITE 250, TORRANCE, CA 90502 <br />O: 310.217.8885 <br />BSBDESIGN.COM <br />REN. 11/30/25DIGITAL <br />SIGNATURE <br />9-9-2024 <br />2130 E 4th St <br />2/11/2025