Laserfiche WebLink
5/ <br />8 <br />" <br />0.2 INCH SPACE BETWEEN CELLS. <br />RAISED <br />WIDTH TO HEIGHT RATIO BETWEEN 3 : 5 AND 1 : 1. <br />STROKE WIDTH TO HEIGHT BETWEEN 1 : 5 AND 1 : 10. <br />CONTRAST CHARACTERS AND SYMBOLS WITH <br />BACKGROUND. <br />SANS SERIF CHARACTERS. <br />PICTOGRAMS / PICTORIAL SYMBOL SIGNS SHALL BE <br />ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION <br />PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER <br />DIMENSION SHALL BE 6" MINIMUM HEIGHT. <br />CHARACTERS AND BACKGROUNDS SHALL BE OF NON-GLARE <br />CONTRASTING COLORS. <br />SIGNS / PICTOGRAMS SHALL BE INSTALLED ON THE WALL <br />ADJACENT TO DOOR LEADING TO THE ROOM OR SPACE <br />THEY DESCRIBE AND AT 60" A.F.F. TO SIGN CENTERLINE AND <br />WHERE A PERSON MAY APPROACH WITHIN 3" OF SIGNAGE <br />WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR <br />STANDING WITHIN THE DOOR SWING AREA. <br />VERTICAL CLEARANCE AT SUSPENDED SIGNS WITH MINIMUM <br />HEADROOM OF 80" REQUIRE MINIMUM 3" CHARACTER <br />HEIGHT MEASURED BY USING UPPERCASE "X". <br />CHARACTERS AND NUMBERS SHALL BE SIZED ACCORDING <br />TO VIEWING DISTANCE FROM WHICH READ. LOWER CASE <br />CHARACTERS PERMITTED. <br />ALL ACCESSIBLE ENTRANCES IDENTIFIED WITH <br />MINIMUM OF ONE STANDARD SIGN. <br />ADDITIONAL DIRECTIONAL SIGNS ALONG <br />ACCESSIBLE PATH OF TRAVEL ARE REQUIRED. <br />BUILDINGS REMODELED TO PROVIDE ACCESSIBLE <br />SANITARY FACILITIES FOR PUBLIC USE SHALL HAVE <br />INFORMATION POSTED IN THE LOBBY AS PART OF <br />THE BUILDING DIRECTORY. <br />STANDARD USED TO IDENTIFY ACCESSIBLE FACILITIES. <br />WHITE FIGURE ON BLUE BACKGROUND, COLOR # 15090 ON <br />FEDERAL STANDARD # 595A. <br />WHEN ENFORCING AGENCY DETERMINES, IF APPROPRIATE, <br />SPECIAL DESIGNS AND COLORS MAY BE APPROVED. <br />USE CONTRASTED GRADE 2 BRAILLE. DOTS TO BE 0.1 INCH <br />ON CENTER IN EACH CELL. <br />DOTS RAISED MINIMUM 0.025 INCH ABOVE BACKGROUND. <br />INTERNATIONAL ACCESSIBILITY SYMBOL <br />INTERNATIONAL TDD <br />SYMBOL <br />INTERNATIONAL <br />SYMBOL OF ACCESS <br />FOR HEARING EMPAIRED <br />58 <br />" <br />- <br /> <br />6 <br />0 <br />" <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />RESTROOM IDENTIFICATION SYMBOLS, 1115B.5 <br />COLOR TO CONTRAST WITH DOOR COLOR <br />NO TEXT OR ISA REQ'D <br />NO BRAILLE ON THIS SIGN <br />12" DIAMETER <br />CONTRASTING <br />COLORS <br />INTERNATIONAL <br />SYMBOL OF <br />ACCESSIBILITY <br />TACTILE & BRAILLE <br />ROOM ID SIGNAGE, 1117B.5.1 (2) <br />6" PICTOGRAM, 117B.5.5 <br />ALL UPPPER CASE TEXT <br />5/8"-2" HEIGHT, RAISED 1/32" CONTRACTED <br />GRADE 2 BRAILLE <br />70% CONTRAST BETWEEN CHARACTERS <br />AND BACKGROUND PER ADAAG A4.30.5 <br />EACH EXIT DOOR THAT LEADS DIRECTLY TO A GRADE LEVEL <br />EXTERIOR EXIT BY MEANS OF A STAIRWAY OR RAMP WITH <br />THE FOLLOWING WORDS AS APPROPRIATE : <br />A. "EXIT STAIR DOWN" <br />B. " EXIT RAMP DOWN" <br />C. " EXIT STAIR UP" <br />D. " EXIT RAMP UP" <br />EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR <br />AREA TO A CORRIDOR OR HALLWAY THAT IS REQUIRED TO <br />HAVE A VISUAL EXIT SIGN W/ THE WORDS - "EXIT ROUTE" <br />36" MAX. <br />7"-9" <br />33 <br />" <br />- <br />3 <br />6 <br />" <br />TO <br />P <br /> <br />O <br />F <br /> <br />G <br />. <br />B <br />. <br />24" <br />17" TO 19" TO <br />TOP OF TOILET <br />ROLL PAPER HOLDER <br />WITHOUT STOPS <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br />29 <br />" <br /> <br />M <br />I <br />N <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />6" MAX. *** <br />17" <br />MIN. <br />8" MIN. * <br />19 <br />" <br />24" <br />MIN. <br />60" MIN. <br />17 <br />" <br />- <br />1 <br />8 <br />" <br />34" <br />32 <br />" <br />44" MIN. CLR. <br />42" (MIN.) GRAB BAR <br />FLUSH <br />ACTIVATOR <br />ON WIDE <br />SIDE <br />36" (MIN.) GRAB BAR <br />30" X 48" MIN. CLR. FLR. SPACE <br />60" X 60" <br />LEVEL AND <br />CLEAR <br />TOILET SEAT DISPENSER <br />(WHERE OCCURS) <br />1-1/2"Ø DIAMETER GRAB BAR W/ <br />PEENED FINISH & 250 LBS. CAPACITY <br />18" <br />MIN. <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />54" MIN. <br />56" MIN. AT WALL MOUNTED <br />W.C. WHEN DOOR SWINGS IN <br />59" MIN. AT FLOOR MOUNTED <br />W.C. WHEN DOOR SWINGS IN <br />12" <br />MAX. <br />42" MIN. <br />GRAB BAR <br />SEAT <br />54" MIN. <br />* KNEE CLEARANCE <br />*** TOE CLEARANCE <br />NOTE : IF A MIN. 9" HEIGHT OF TOE <br />CLEARANCE IS PROVIDED, A MAXIMUM <br />OF 6" OF THE 48" OF CLEAR FLOOR <br />SPACE REQUIRED AT THE FIXTURE <br />MAY EXTEND INTO TOE SPACE. <br />MIN. <br />CLEAR <br />60" <br />DIA <br />. <br />40 <br />" <br /> <br />M <br />A <br />X <br />TO <br /> <br />R <br />E <br />F <br />L <br />E <br />C <br />T <br />I <br />V <br />E <br />SU <br />R <br />F <br />A <br />C <br />E <br />9" <br /> <br />M <br />I <br />N <br />. <br />17"-18" TYP. <br />24 <br />" <br /> <br />M <br />I <br />N <br />. <br />60 <br />" <br /> <br />D <br />I <br />A <br />. <br />32" <br />CLR. <br />18" MIN. CLEAR, <br />24" PREFERRED <br />17 <br />" <br /> <br />M <br />I <br />N <br />. <br />9" <br /> <br />M <br />A <br />X <br />. <br />TO CENTERLINE <br />PROVIDE PRIVACY DOOR <br />LOCK WHEN IT IS A PRIVATE <br />TOILET OR FOR UNISEX USE. <br />GRAB BARS; SEE TYPICAL <br />ACCESSIBILITY NOTES <br />SHEET. <br />48" MIN. WHEN FRONT <br />ENTRY DOOR OR 60" <br />MINIMUM WHEN SIDE <br />ENTRY DOOR <br />42" GRAB BAR <br />36" (MIN.) <br />GRAB BAR <br />54 <br />" <br /> <br />M <br />I <br />N <br />. <br />30" X 48" <br />MIN. CLR. <br />FLR. <br />SPACE <br />MAX.6" <br />WARNING FOR THE VISION IMPAIRED AT A <br />PROJECTED DRINKING FOUNTAIN CAN BE PROVIDED <br />BY THE FOLLOWING MEANS: <br />INSTALL WING WALLS ON EACH SIDE OF THE DRINKING FOUNTAIN TO PROJECT OUT FROM <br />THE MAIN WALL AT LEAST AS FAR AS THE DRINKING FOUNTAIN AND TO WITHIN 6" OF THE <br />PATH OF TRAVEL FLOOR FINISH. THERE MUST BE 32" CLEAR BETWEEN THE WING WALLS. <br /> 36" MIN. IF ALCOVE DEPTH IS > 24". <br /> WATER FLOW :THE SPOUT SHALL <br />PROVIDE AT LEAST 4" HIGH MINIMUM AND <br />SHALL BE LOCATED 5" MAX. FROM THE <br />FRONT OF THE UNIT. <br />1-1/4" TO 1-1/2" <br />OUTSIDE DIA. <br />34 <br />" <br /> <br />T <br />O <br /> <br />3 <br />8 <br />" <br />12" <br />TW + 12" <br />BOTTOM LANDING <br />1'-0" <br />MIN. <br />34 <br />" <br /> <br />T <br />O <br /> <br />3 <br />8 <br />" <br />GRAB BAR <br />HANDRAIL HANDRAIL <br />GRAB BAR <br />1- <br />1 <br />/ <br />2 <br />" <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />PROVIDE SECOND <br />SET OF HANDRAILS <br />AT 24' A.F.F. WHEN <br />CHILDREN ARE <br />PRIMARY USERS. <br />VISUAL WARNING STRIPS <br />SHALL BE 2" MIN. WIDTH <br />AND INSTALLED 1" MAX. <br />FROM EDGE OF THE TOP <br />AND BOTTOM TREADS OF <br />INTERIOR STAIRS, AND <br />ON ALL TREADS OF <br />EXTERIOR STAIRS. <br />TOP LANDING <br />TW = TREAD WIDTH <br />34 <br />" <br /> <br />T <br />O <br /> <br />3 <br />8 <br />" <br />11" <br />MIN. <br />48" MIN. SIDEWALK <br />36" MIN. CLR.36" MIN. CLR. <br />48" MIN. SIDEWALK <br />ADJACENT HAZARD <br />27 <br />" <br />34 <br />" <br />T <br />O <br /> <br />3 <br />8 <br />" <br />34 <br />" <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />1. ALL RAMPS MUST MEET HANDRAIL AND CURB REQUIREMENTS. <br />AS REQUIRED <br />SEE NOTE 2. <br />SEE NOTE 2. <br />SEE NOTE 2. <br />AS REQUIRED <br />30 <br />" <br />NOTE: <br />48" MIN. <br />27 <br />" <br />34 <br />" <br /> <br />T <br />O <br /> <br />3 <br />8 <br />" <br />2. MAXIMUM HORIZONTAL DISTANCE OF EACH RAMP AND RUN VARY. <br />12" MIN.12" MIN. <br />HORIZONTAL RAILING <br />REQUIRED WHERE <br />INTERMEDIATE RAILS WITH A <br />MAXIMUM OF 4" CLEAR <br />SPACE BETWEEN INTERMED. <br />RAILS ARE NOT REQUIRED, <br />TYPICAL. <br />6" HIGH WARNING CURB <br />REQUIRED WHEN A 4" (OR <br />MORE) DROP OCCURS. <br />4" MINIMUM TO 30" MAXIMUM <br />GUARD RAIL AND CURB <br />WHEN DOOR SWINGS ONTO <br />LANDING 42" MIN. PLUS <br />DOOR WIDTH <br />30" MAX. RISE (TYP.) <br />WHEN DOOR SWINGS ONTO LANDING <br />42" MIN. PLUS DOOR WIDTH <br />30" MAX. <br />RISE (TYP.) <br />WHEN DOOR SWINGS <br />ONTO LANDING 42" MIN. <br />PLUS DOOR WIDTH <br />AS REQUIRED <br />30" MAX. <br />RISE (TYP.)INTERMEDIATE <br />TURNING PLATFORM <br />INTERMEDIATE LEVEL <br />PLATFORM <br />CURB <br />(TYP.) <br />STREET <br />(TYP.) <br />GUARD RAIL <br />CENTERED AT <br />3" +1" HIGH <br />BOTTOM LEVEL PLATFORM <br />TOP <br />PLATFORM <br />INTERMEDIATE <br />PLATFORM <br />60" MIN. WHEN NO DOOR <br />SWINGS ONTO LANDING <br />TOP <br />PLATFORM <br />60" MIN. WHEN NO DOOR <br />SWINGS ONTO LANDING <br />60" MIN. WHEN NO DOOR <br />SWINGS ONTO LANDING <br />NOTE : MAXIMUM HORIZONTAL DISTANCES OF EACH RAMP AND RUN VARY. <br />FACE OF <br />CURB <br />HANDRAIL AND CURB AT <br />RAMPS <br />2. <br />3. <br />4. <br />AUTOMATIC DOORS AND POWER ASSISTED DOORS <br />SHALL COMPLY WITH BHMA A156.10. SLOW <br />OPENING, LOW-POWERED, AUTOMATIC DOORS <br />SHALL COMPLY WITH BHMA A156.19. SUCH DOORS <br />SHALL NOT OPEN TO BACK CHECK FASTER THAN 3 <br />SECONDS AND SHALL REQUIRE NO MORE THAN 15 <br />LBF. TO STOP DOOR MOVEMENT. IF A POWER <br />ASSISTED DOOR IS USED. ITS DOOR OPENING <br />FORCE SHALL COMPLY WIHT 1133B.2.5 AND ITS <br />CLOSING SHALL CONFORM TO THE <br />REQUIREMENTS OF IN BHMA A156.19. WHEN AN <br />AUTOMATIC DOOR OPERATOR IS UTILIZED TO <br />OPERATE A PAIR OF DOORS, AT LEAST ONE OF <br />THE DOORS SHALL PROVIDE A CLEAR <br />UNOBSTRUCTED OPENING WIDTH OF 32" WITH THE <br />DOOR POSITIONED AT AN ANGLE OF 90 DEGREES <br />FROM ITS CLOSED POSITION. <br />THE BOTTOM 10" OF DOORS EXCEPT SLIDING AND <br />AUTOMATIC SHALL HAVE A SMOOTH UNITERRUPTED <br />SURFACE TO ALLOW THE DOOR TO BE OPENED BY A <br />WHEELCHAIR FOOTREST WITHOUT CREATING TRAP <br />OR HAZARDOUS CONDITION. <br />LATCHING AD LOCKING DOORS THAT ARE HAND <br />OPERATED AND WHICH ARE IN A PATH OF TRAVEL ARE <br />OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE, <br />PANIC BARS, PUSH-PULL ACTIVATING BARS OR OTHER <br />HARDWARE DESIGNED TO PROVIDE PASSAGE. <br />HAND ACTIVATED DOOR OPENING HARDWARE , <br />HANDLES, LATCHES , PULLS, LOCKS AND OTHER <br />OPERATING DEVICES ON ACCESSIBLE DOORS SHALL <br />HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND <br />AND DOES NOT REQUIRE TIGHT GRASPING, TIGHT <br />PINCHING OR TWISTING OF THE WRIST TO OPERATE. <br />OPENING HARDWARE IS CENTERED BETWEEN <br />34" - 44" ABOVE FINISH FLOOR. <br />MAXIMUM 5 LBS. EFFORT TO OPERATE EXTERIOR <br />DOOR AND INTERIOR DOOR. 15 LBS MAX. <br />PRESSURE TO OPERATE FIRE DOORS. <br />34" TO 44" <br />CENTERLINE <br />OF LEVER OR U <br />SHAPED <br />HANDLE <br />10" MIN. BOTTOM <br />RAIL OR PROVIDE <br />KICK PLATE <br />RUBBER BUMPER ON CHAIR <br />5. <br />48 <br />" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />60 <br />" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />DO <br />O <br />R <br /> <br />W <br />I <br />D <br />T <br />H <br /> <br />P <br />L <br />U <br />S <br /> <br />4 <br />2 <br />" <br />60" MIN. <br />48" MINIMUM <br />48 <br />" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br />32" CLR. <br />36" <br />MIN. <br />60 <br />" <br />MI <br />N <br />. <br />PUSH SIDE <br />54" MIN. <br />*4 <br />4 <br />" <br /> <br />M <br />I <br />N <br />. <br />12" MIN. <br />WHERE ADJACENT <br />OBSTRUCTION OR <br />WALL OCCURS <br />PROVIDE THIS <br />ADDTIONAL SPACE <br />IF DOOR IS <br />EQUIPPED <br />WITH BOTH A LATCH <br />AND A CLOSER. <br />24"MIN. CLR. AT <br />EXTERIOR DOORS <br />18" MIN. CLR. AT <br />INTERIOR DOORS <br />* NOTE: <br />48" MINIMUM IF <br />DOOR HAS BOTH A <br />LATCH AND A <br />CLOSER <br />24" MIN. <br />EXTERIOR <br />OF BLDG. <br />24" MIN. EXTERIOR & 18" <br />MINIMUM INTERIOR <br />BEYOND THE STRIKE <br />EDGE OF A GATE OR <br />DOOR ON THE SIDE <br />TOWARD WHICH IT <br />SWINGS. <br />12" <br />MIN. <br />PUSH <br />SIDE <br />PULL <br />SIDE <br />X SHALL BE LESS THAN OR EQ. TO 25 INCHES; Z SHALL BE <br />WHEN X IS LESS THAN 20 INCHES, THEN Y SHALL BE 48 INCHES MAX. <br />WHEN X IS 20 TO 25 INCHES, THEN Y SHALL BE 44 INCHES MAXIMUM. <br />48 <br />" <br />48" MIN. <br />X <br />Y <br />Z <br />48" <br />48" <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />48" <br />MIN. <br />Z <br />X <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />54 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br />30" <br />46 <br />" <br /> <br />M <br />A <br />X <br />. <br />24"30" <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />34 <br />" <br /> <br />M <br />A <br />X <br />. <br />10" <br />10"30" <br />GREATER THAN OR EQUAL TO X. <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />. <br />1/4" MAX. <br />1/2" MAX. <br />CANE RANGE <br />27 <br />" <br /> <br />M <br />A <br />X <br />. <br />WHEN 27" <br />80 <br />" <br /> <br />M <br />I <br />N <br />. <br />12" <br />MAX. <br />CANE RANGE <br />OR BELOW <br />POSTS OR <br />PYLON <br />COMPRESSED CARPET 1/4" MAX. BELOW THRESHOLD <br />FIN. FLOOR EVEN <br />THRESHOLD <br />1/2" MAX. <br />PILE HEIGHT <br />CANE HITS POST OR PYLON <br />BEFORE PERSON HITS OBJECT <br />AT 1:2 SLOPE <br />ALL DISPENSERS <br />40" MAX. TO <br />HIGHEST OPERABLE <br />PART <br />48 <br />" <br />- <br />6 <br />0 <br />" <br /> <br />A <br />. <br />F <br />. <br />F <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />A. <br />F <br />. <br />F <br />. <br />MAN/WOMAN PICTOGRAM DESIGN <br />NOT REGULATED <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />A. <br />F <br />. <br />F <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />A. <br />F <br />. <br />F <br />. <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />A. <br />F <br />. <br />F <br />. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />A. <br />F <br />. <br />F <br />. <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />A. <br />F <br />. <br />F <br />. <br />3MULTIPLE ACCOMODATION TOILET <br />N.T.S. <br />1PEDESTRIAN RAMP & NOTES <br />N.T.S. <br />8STAIR & HANDRAIL NOTES <br />N.T.S. <br />7SINGLE ACCOMODATION TOILET <br />N.T.S.11DRINKING FOUNTAIN <br />N.T.S.15SIGNS / PICTOGRAMS <br />N.T.S. <br />18PROTRUDING OBJECTS <br />N.T.S. <br />17THRESHOLD / LEVEL CHANGES <br />N.T.S.9DOOR CLEARANCES <br />N.T.S.13REACH REQUIREMENTS <br />N.T.S. <br />7" <br />MA <br />X <br />. <br />CLIENT: <br />SUBMITTAL <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />B <br />S <br />B <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />, <br /> <br />i <br />n <br />c <br />. <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />a <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />DATEREVISION <br />SHEET TITLE <br />SHEET NO. <br />08.08.2023PLANNING SUBMITTAL <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />21 <br />3 <br />0 <br /> <br />E <br />. <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br /> <br /># <br />2 <br />0 <br />0 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />- <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br /> <br />T <br />I <br />CM220584.00 <br />21 <br />3 <br />0 <br /> <br />E <br />. <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />CL <br />I <br />E <br />N <br />T <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />1ST PC SUBMITTAL - BUILDING <br />1ST PLAN CHECK SUBMITTAL <br />- BUILDING DEPT <br />02.08.2024 <br />G-001 <br />ACCESSIBILITY NOTES & DETAILS <br />2130 E 4th St <br />2/11/2025