GENERAL NOTES <br />CS-02 <br />1.GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT JOB <br />SITE AND REQUEST CLARIFICATION FROM " BSB DESIGN " , REGARDING DISCREPANCIES BETWEEN <br />DRAWINGS AND FIELD CONDITIONS BEFORE COMMENCING ANY WORK. <br />2.CONTRACTOR SHALL NOT SCALE DRAWINGS. ALL NOTED DIMENSIONS GOVERN. LARGE SCALE <br />DETAILS OVERRIDE SMALL SCALE DETAILS. ALL DISCREPANCIES SHOULD BE BROUGHT TO THE <br />ATTENTION OF "BSB DESIGN" PRIOR TO COMMENCEMENT OF INSTALLATION. <br />3.ALL SNAP LINES AND SPRAYED CORNERS ARE TO BE PUT DOWN AND APPROVED BY "BSB DESIGN", <br />PRIOR TO THE START OF FRAMING. <br />4.ALL "HOLD" DIMENSIONS MUST BE MAINTAINED. <br />5.ALL PARTITIONS SHOWN AS "ALIGN" ARE TO BE SMOOTH AND FLUSH WITH EXISTING <br />CONSTRUCTION. <br />6.PROVIDE METAL CORNER BEADS AT ALL DRYWALL PARTITION CORNERS AND ENDS. <br />7.WHERE REQUIRED, PROVIDE FURRING OR MINIMUM ADDITIONAL PARTITION THICKNESS WITH <br />CONTINUOUS INSULATION FOR PLUMBING WALLS. <br />8.ALL PAINTED METAL GYP. BD. WALL / CEILING REVEALS SHALL BE CONTINUOUS WITH WELDED <br />AND MITERED CONNECTIONS TYPICAL. <br />9.WHERE METAL STUD FRAMING ADJOINS METAL DUCTS OR PIPES, OR WHERE TWO METALS ARE <br />AFFIXED TO EACH OTHER, THE GENERAL CONTRACTOR WILL PROVIDE INSULATING MATERIAL <br />BETWEEN SO THAT NO VIBRATION OR NOISE WILL BE TRANSMITTED. ALL LOCATIONS ARE TO BE <br />BROUGHT TO "BSB DESIGN" ATTENTION. <br />10.AT ALL RATED PARTITIONS AND PARTITIONS OR BAFFLES EXTENDING TO THE FLOOR STRUCTURE <br />ABOVE WILL BE SCALED TO THAT STRUCTURE, TO PERIMETER WALLS AND AROUND ANY <br />PENETRATIONS SUCH AS PIPES OR DUCTS. WHERE A DUCT OR OTHER CONSTRUCTION RUNS <br />PARALLEL WITH A RATED PARTITION, OFFSET THAT PARTITION ABOVE THE CEILING AROUND THE <br />CONSTRUCTION TO MAINTAIN THE FIRE RATING. ALL SUCH CONDITIONS SHOULD BE IDENTIFIED ON <br />THE COORDINATION DRAWINGS AND SUBMITTED TO THE "BSB DESIGN " FOR APPROVAL. <br />11.ALL GYPSUM WALL BOARD USED WILL BE 5/8" FIRE CODE TYPE "X" BY U.S.G., U.O.N. <br />12.GENERAL CONTRACTOR TO SCAR PATCH ALL CORE WALLS AND PERIMETER BASE BUILDING <br />WALLS NOT IN ALIGNMENT WITH THE ADJACENT CORE WALLS & SCARRED FROM DEMOLITION OR <br />EXISTING CONDITIONS AS REQUIRED. <br />13.CONTRACTOR IS RESPONSIBLE TO COORDINATE DEPTH OF FIRE EXTINGUISHER CABINET WITH <br />NEW PARTITIONS. CONTRACTOR TO THICKEN SPECIFIED PARTITION AS REQUIRED TO INSTALL <br />CABINET CORRECTLY AS MANUFACTURED RECOMMENDS. CONTRACTOR TO THICKEN PARTITION <br />AS REQUIRED TO HOLD NEW CABINET. PARTITIONS TO BE THICKENED FOR ENTIRE LENGTH OF <br />WALL. <br />14.CONTRACTOR TO SPRAY PAINT LOCATION OF ALL FIXTURES, WALLS, MILLWORK, OUTLETS, LIGHTS, <br />ETC. FOR " BSB DESIGN" APPROVAL PRIOR TO ANY CONSTRUCTION STARTING. ONCE "BSB DESIGN" <br />APPROVES ALL LAYOUTS, THEN CONTRACTOR CAN PROCEED WITH THE PROJECT. "BSB DESIGN" <br />SHALL BE NOTIFIED OF ANY DEVIATION FROM DIMENSIONS OR CLEARANCES INDICATED ON PLANS <br />REQUIRED DUE TO FIELD CONDITIONS. <br />15.CONTRACTOR TO PROVIDE SOUND RESISTANT SEALANT AT WHEREVER CONDUIT, J-BOXES, <br />PLUMBING PIPES, ETC. OCCUR. PIERCE ACOUSTICAL PARTITIONS OR CEILINGS. CONTRACTOR TO <br />OBTAIN "EQUAL TO" STC / NRC RATINGS AT PARTITIONS WITH NO PIERCING. <br />16.ALL SURFACES SCHEDULED TO RECEIVE WALL COVERING MUST BE ABSOLUTELY FREE OF ANY <br />DEFECT THAT WILL BE VISIBLE THROUGH THE INSTALLED WALL COVERING. SUCH SURFACES WILL <br />RECEIVE ONE (1) COAT OF FLAT PRIME PAINT PRIOR TO INSTALLATION. THE GENERAL <br />CONTRACTOR WILL APPLY ALL WALL COVERING IN ACCORDANCE WITH THE MANUFACTURER'S <br />SPECIFICATIONS. THE GENERAL CONTRACTOR WILL EXAMINE ALL SUCH MATERIALS FOR DEFECTS <br />AND VARIATION IN COLOR BEFORE APPLICATION, AND NOTIFY " BSB DESIGN " IF ANY SUCH <br />DEFECTS ARE FOUND. <br />17.CONTRACTOR SHALL PROVIDE A MINIMUM OF LEVEL "4" FINISH ON ALL GYP. BD. WALLS PRIOR TO <br />PAINTED FINISH APPLICATION. NEW PARTITIONS SHALL BE APPROVED FOR FINISH BY " WITHEE <br />MALCOLM ARCHITECTS " AS REQUIRED PRIOR TO PAINTING. CONTRACTOR TO PUT IN WRITING AND <br />NOTIFY " BSB DESIGN " IF THEY ARE PROVIDING A FINISHED LEVEL LESS THAN "4". <br />18.CONTRACTOR SHALL PROVIDE TEMPERED GLASS AS REQUIRED BY CODE AT SCHEDULED GLASS <br />PARTITIONS. <br />19.CONTRACTOR SHALL PROVIDE FRAMELESS ACCESS PANELS AS REQUIRED FOR MECHANICAL, <br />ELECTRICAL, AND PLUMBING INSTALLATIONS PER APPLICABLE BUILDING CODES. CONTRACTOR <br />SHALL COORDINATE TYPE AND LOCATION OF ACCESS PANELS WITH " BSB DESIGN " PRIOR TO <br />INSTALLATION. PROVIDE GFRG PANELS AT GYP BOARD CEILINGS U.O.N.. <br />20.THE GENERAL CONTRACTOR WILL DOUBLE UP METAL STUDS AT ALL DOORS AND WINDOW <br />OPENINGS UNLESS OTHERWISE NOTED. <br />GENERAL NOTESPARTITION NOTES <br />FIRE DEPARTMENT NOTES <br />1.AMERICAN INSTITUTE OF ARCHITECTS DOCUMENT #A201-2010, "GENERAL CONDITIONS OF THE <br />CONTRACT FOR CONSTRUCTION," SHALL GOVERN THE WORK OF THIS CONTRACT. BIDDERS ARE <br />REQUIRED TO BECOME FAMILIAR WITH THESE DOCUMENTS. <br />2.PRECEDENT: <br /> LARGE SCALE DRAWINGS TAKE PRECEDENCE OVER SMALL SCALE DRAWINGS. DETAILS TAKE <br />PRECEDENCE OVER ALL. NOTIFY " BSB DESIGN " OF CONFLICTS OR DISCREPANCIES IN WRITING <br />PRIOR TO COMMENCEMENT OF CONSTRUCTION. <br />3.DIMENSION CONVENTIONS: <br />A.DIMENSIONS ARE SHOWN FROM FACE OF STUD, U.N.O. <br />B.DIMENSIONS NOTED "CLEAR" OR "CLR." MUST BE PRECISELY MAINTAINED ALLOWING FOR <br />THICKNESS OF MATERIAL. <br />C.DIMENSIONS ARE NOT ADJUSTABLE WITHOUT " BSB DESIGN "'S APPROVAL, U.O.N <br />D.DIMENSIONS TO EXTERIOR WINDOW WALL ARE TO INSIDE FINISHED FACE OF THE WALL, <br />U.O.N. <br />E.DIMENSIONS TO EXTERIOR GLAZING ARE TO THE INSIDE FACE OF THE EXTERIOR GLAZING. <br />F.VERTICAL DIMENSIONS ARE FROM THE TOP OF THE FINISHED FLOOR, U.N.O. <br />G.DO NOT SCALE DRAWINGS. IF ANY ITEM OF WORK CANNOT BE LOCATED, DO NOT PROCEED <br />WITH THE WORK BEFORE CLARIFYING WITH " BSB DESIGN " <br />H.VERIFY DIMENSIONS MARKED "V.I.F."OR PRIOR TO START OF CONSTRUCTION. REPORT <br />INCONSISTENCIES TO " BSB DESIGN " <br />4.DEFINITION OF TERMINOLOGY: <br />A."TYPICAL" MEANS IDENTICAL FOR ALL CONDITIONS, U.N.O. <br />B."SIMILAR" MEANS COMPARABLE CHARACTERISTICS FOR THE CONDITIONS NOTED. <br />C."PROVIDE" MEANS FURNISH AND INSTALL, COMPLETE AND IN PLACE. <br />D."INSTALL" MEANS PUT INTO PLACE AN ITEM SUPPLIED BY CLIENT OR OTHERS. <br />E."ALIGN" MEANS ACCURATELY LOCATE FINISH FACES IN THE SAME PLANE. <br />5.ALL REQUIRED PERMITS AND LICENSES SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. <br />6.AT THE TIME OF BID SUBMITTAL, THE CONTRACTOR SHALL ADVISE " BSB DESIGN ", IN WRITING, OF <br />ANY SPECIFIED MATERIALS OR EQUIPMENT WHICH ARE EITHER UNAVAILABLE OR WILL CAUSE A <br />DELAY TO THE COMPLETION OF CONSTRUCTION. <br />7.CONTRACTOR IS RESPONSIBLE AT BID TIME, TO VERIFY WHETHER EXISTING CEILING GRID <br />ATTACHMENT SYSTEM REQUIRES MODIFICATIONS OR UPGRADE TO MEET SEISMIC <br />REQUIREMENTS. IF SO, THIS SHOULD BE INCLUDED IN SCOPE OF WORK. CHANGE ORDERS FOR <br />THIS TASK WILL NOT BE ACCEPTED DURING CONSTRUCTION. <br />8.CONTRACTOR TO VERIFY AT BID TIME IF EXISTING PIPES, HVAC OR ANY OTHER ITEM NEEDS TO BE <br />RELOCATED TO ACCOMMODATE THE PROPOSED DESIGN. IF SO, THESE RELOCATIONS SHOULD BE <br />IDENTIFIED IN THE BID TO BE ACCEPTED OR REJECTED BY ARCHITECT. CHANGE ORDERS FOR <br />THESE KINDS OF RELOCATIONS AT ACCESSIBLE CEILINGS WILL NOT BE ACCEPTED DURING <br />CONSTRUCTION. <br />9.BY ENTERING INTO AN AGREEMENT WITH THE CLIENT, THE CONTRACTOR REPRESENTS THAT HE <br />HAS VISITED THE JOB SITE, FAMILIARIZED HIMSELF WITH EXISTING CONDITIONS, AND NOTED IN <br />WRITING AND PROVIDED TO " BSB DESIGN " / OWNER ANY DISCREPANCIES WITH THE <br />REQUIREMENTS OF THE CONTRACT DOCUMENTS. <br />10.IMMEDIATELY AFTER BEING AWARDED THE CONTRACT, THE CONTRACTOR SHALL SUBMIT A <br />CONSTRUCTION SCHEDULE WHICH SHALL BE CONTINUOUSLY UPDATED AND POSTED ON THE JOB <br />SITE AT ALL TIMES. <br />11.THE CONTRACTOR SHALL VERIFY THE REQUIRED LOCATIONS AND RELATED COSTS FOR ALL <br />NECESSARY FRAMELESS ACCESS PANELS (IN PARTITIONS, FLOORS OR CEILINGS). THE <br />CONTRACTOR SHALL COORDINATE WITH " BSB DESIGN " BEFORE INSTALLATION. <br />12.ALL PARTITIONS, FLOORS AND CEILINGS SHALL BE PATCHED OR REPAIRED AS REQUIRED FOR <br />FINISH APPLICATIONS. PATCHED AND REPAIRED SURFACES SHALL BE EQUAL TO NEW. THE <br />CONTRACTOR SHALL ADVISE " BSB DESIGN " OF ANY EXISTING CONSTRUCTION WHICH IS NOT <br />LEVEL AND PLUMB (WITHIN INDUSTRY STANDARDS) BEFORE START OF CONSTRUCTION. FLOOR <br />PREP SHOULD THEREFORE BE INCLUDED IN THE JOB BID. <br />13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING TEMPORARY UTILITIES (POWER, <br />LIGHTING, WATER AND RESTROOM FACILITIES) TO THE JOB SITE FOR USE BY ALL CONSTRUCTION <br />TRADES, INCLUDING THOSE NOT A SUBCONTRACTOR TO THE GENERAL CONTRACTOR. <br />CONTRACTOR TO PROVIDE PROTECTION AS REQUIRED. ANY DAMAGE TO THESE FACILITIES SHALL <br />BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. <br />14.THE CONTRACTOR SHALL NOTE THAT THERE SHALL BE NO SUBSTITUTIONS FOR ANY MATERIAL <br />WHERE SPECIFIC MANUFACTURERS ARE SPECIFIED. WHERE APPROVED EQUAL IS USED, IT SHALL <br />BE UNDERSTOOD THAT THE SUBSTITUTE SHALL BE BY JUDGMENT AND APPROVAL OF " BSB <br />DESIGN ", AND ALL REQUESTS SHALL BE MADE PRIOR TO INSTALLATION. CONTRACTOR SHALL <br />SUBMIT THREE (3) SETS OF MANUFACTURER'S CUT SHEETS OF SAMPLES AND/OR ONE (1) <br />REPRODUCIBLE ORIGINAL OF DWG'S FOR ALL REQUESTED SUBSTITUTIONS OF MATERIALS, <br />HARDWARE, MILLWORK, GLASS PARTITIONS, CEILING SYSTEMS, PLUMBING FIXTURES, ETC. TO <br />"BSB DESIGN " FOR APPROVAL. <br />15.ALL CONTRACTORS SHALL CONTACT BUILDING MANAGEMENT TO DETERMINE THE BUILDING <br />OWNER'S RULES FOR CONSTRUCTION, DELIVERIES, CONSTRUCTION TASKS TO BE PERFORMED <br />OUTSIDE REGULAR BUSINESS HOURS ONLY, AND ANY OTHER SPECIAL BUILDING REQUIREMENTS <br />WHICH WILL AFFECT THE WORK. IF OVERTIME WORK IS REQUIRED BY ANY TRADE, APPROVAL <br />(INCLUDING COST APPROVAL) MUST BE OBTAINED PRIOR TO THE EXECUTION OF ANY WORK. THE <br />GENERAL INTENT IS THAT ALL WORK EXCEPT FOR NOISE-GENERATING CONSTRUCTION SHALL BE <br />PERFORMED ON REGULAR TIME. <br />16.MANUFACTURERS OF MATERIALS, OTHER THAN THOSE SPECIFIED ON THESE PLANS, SHALL MEET <br />THE SPECIFIC REQUIREMENTS OF GOVERNING AGENCIES HAVING JURISDICTION OVER THIS <br />PROJECT. WHEN SUBSTITUTIONS OF THE SPECIFIED MATERIALS ARE REQUESTED TO BE MADE BY <br />THE CONTRACTOR (WHETHER AS AN "APPROVED EQUAL" OR NOT) THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR ALL EXPENSES INCURRED BY " BSB DESIGN " IN REVIEWING, RESEARCHING, <br />APPROVING, AND COORDINATING REQUESTED SUBSTITUTIONS. <br />17.GENERAL CONTRACTOR OR HIS SUBCONTRACTORS SHALL BE RESPONSIBLE FOR VERIFICATION <br />AND APPROVALS OF SUBSTITUTED MATERIALS AS REQUESTED BY GOVERNING AGENCIES. ALL <br />SUBSTITUTIONS ARE TO BE BROUGHT TO THE ATTENTION OF " BSB DESIGN " PRIOR TO <br />COMMENCEMENT OF INSTALLATION. IF THIS NOTIFICATION IN WRITING DOES NOT OCCUR OR IS <br />REJECTED, " BSB DESIGN " ASSUMES NO RESPONSIBILITY FOR THE MATERIAL. <br />18.THE CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION <br />DRAWINGS ON SITE DURING ALL CONSTRUCTION PHASES FOR THE USE OF ALL TRADES. THE <br />CONTRACTOR SHALL SEE THAT ALL SUBCONTRACTORS RECEIVE COMPLETE SETS OF <br />CONSTRUCTION DRAWINGS, AT ALL TIMES DURING THE PROGRESS OF THE JOB (I.E. REVISIONS) <br />ON A TIMELY BASIS, OR ASSUME FULL RESPONSIBILITY FOR COORDINATION OF WORK WHEN <br />COMPLETE SETS ARE NOT AVAILABLE TO SUBCONTRACTORS. <br />19.UPON COMPLETION OF THE JOB, THE GENERAL CONTRACTOR SHALL SUBMIT CERTIFICATES OF <br />INSPECTION OF SATISFACTORY COMPLETION TO " BSB DESIGN " <br />20.CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN <br />CONFORMANCE WITH ANY CODE OR CODES OF FEDERAL, STATE, COUNTY OR MUNICIPALITY <br />HAVING JURISDICTION OVER SUCH WORK. ALL APPLICABLE REQUIREMENTS IN THESE <br />REGULATIONS SHALL BE FOLLOWED THE SAME AS IF NOTED ON THE DRAWINGS. CONFLICTS <br />BETWEEN WORK SET FORTH ON THE DRAWINGS AND BUILDING CODES, LAWS OR REGULATIONS <br />NOTED BY THE GENERAL CONTRACTOR SHALL BE SUBMITTED TO " BSB DESIGN " FOR <br />RESOLUTION BEFORE PROCEEDING WITH THE WORK. <br />21.THE CONTRACTOR SHALL, AT ALL TIMES, KEEP PREMISES FREE FROM ALL ACCUMULATION OF <br />DEBRIS CAUSED BY HIS OPERATIONS. AT THE COMPLETION OF THE WORK, SHALL CLEAN ALL <br />GLASS AND WOOD SURFACES AND LEAVE THE WORK "BROOM CLEAN." SHALL ALSO CLEAN ALL <br />LIGHT FIXTURES. <br />22.THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND OTHER <br />ITEMS NECESSARY FOR THE COMPLETION OF ALL WORK SHOWN, CALLED FOR, OR REASONABLY <br />IMPLIED BY THE CONTRACT DOCUMENTS EXCEPT WHERE SPECIFICALLY NOTED OTHERWISE. <br />23.WHERE WORK OR EQUIPMENT IS INDICATED AS N.I.C., SUCH WORK AND/OR EQUIPMENT SHALL BE <br />PROVIDED BY OTHERS. CONTRACTOR SHALL COORDINATE AND COOPERATE TO EFFECT SUCH <br />INSTALLATION. <br />24.ALL REQUESTS FOR CLARIFICATION OF THESE DRAWINGS SHALL BE DIRECTED TO " BSB DESIGN " <br />CONFLICTS ARISING BETWEEN DETAILS AND/OR PLANS SHALL BE BROUGHT TO THE ATTENTION <br />OF " BSB DESIGN" FOR CLARIFICATION IN WRITING BY THE CONTRACTOR BEFORE PROCEEDING <br />WITH THE WORK. <br />25.GENERAL CONTRACTOR SHALL PROVIDE SHOP DRAWINGS (ONE PDF AND ONE FULL SIZE PRINT) <br />OF ALL CUSTOM MANUFACTURER DESIGN ELEMENTS INCLUDED HERE WITHIN TO " BSB DESIGN " <br />FOR APPROVAL PRIOR TO MANUFACTURING. UNLESS OTHERWISE AUTHORIZED BY " BSB DESIGN " <br />NO MANUFACTURING SHALL BE PERFORMED WITHOUT SAID SHOP DRAWINGS. <br />26.NO EXTRA WORK OR CHARGE SHALL BE MADE UNLESS A WRITTEN COUNTERSIGNED ORDER FROM <br />THE OWNER, SIGNED OR COUNTERSIGNED BY " BSB DESIGN", OR A WRITTEN ORDER FROM " BSB <br />DESIGN ", IS OBTAINED. THIS ORDER SHALL STATE THAT THE TENANT HAS AUTHORIZED THE <br />EXTRA WORK OR CHARGE, AND NO CLAIM FOR ANY ADDITIONAL SUM SHALL BE VALID UNLESS SO <br />OFFERED AND PRESENTED AS DESCRIBED ABOVE. <br />27.GENERAL CONTRACTOR SHALL PROVIDE ALL DOORS, FRAMES AND RELATED HARDWARE, U.O.N. <br />28.GENERAL CONTRACTOR IS RESPONSIBLE FOR REVIEWING AND VERIFYING DEMOLITION PLANS IN <br />RELATION TO STRUCTURAL AND/OR CONSTRUCTION DRAWINGS. " BSB DESIGN " IS TO BE <br />NOTIFIED OF ANY CONFLICTS, DISCREPANCIES OR PROBLEMS. <br />29.ALL EQUIPMENT AND MATERIAL WHICH IS IN OPERATING CONDITION WHEN REMOVED, SHALL BE <br />MAINTAINED AS SUCH AND RETURNED AS PER OWNER'S REQUIREMENTS. <br />30.GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE IDENTIFICATION, ABATEMENT AND <br />PROPER DISPOSAL OF ANY AND ALL ASBESTOS/TOXIC MATERIALS THAT MAY EXIST AT THE JOB <br />SITE. <br />31.GENERAL CONTRACTOR SHALL SUBMIT THREE (3) 12" X 12" SAMPLES OF ALL FINISH MATERIALS <br />(STONE, PAINT, CARPET, WOOD, TILE, ETC.) SPECIFIED ON SCHEDULES, PLANS, DETAILS AND <br />DRAWINGS FOR REVIEW AND APPROVAL BY " BSB DESIGN". <br />32.GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURER'S CUT SHEETS FOR <br />ALL NEW DESIGN ELEMENTS OR EQUIPMENT BEING PROVIDED OR INSTALLED ON THE BUILDING <br />EXTERIOR (INCLUDING THE ROOF) ASSOCIATED WITH THE CONTRACTED PROJECT'S <br />CONSTRUCTION FOR REVIEW BY " BSB DESIGN ". <br />33.GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURER'S CUT SHEETS FOR <br />ALL NEW PLUMBING AND ELECTRICAL FIXTURES, EQUIPMENT AND ACCESSORIES BEING PROVIDED <br />OR INSTALLED FOR REVIEW BY " BSB DESIGN ". <br />34.GENERAL CONTRACTOR SHALL PROVIDE A FINAL PUNCH LIST FOR " BSB DESIGN " APPROVAL. <br />THREE (3) COPIES OF THE CLOSE-OUT PACKAGE INCLUDING AS-BUILT DWGS, WARRANTIES ETC. <br />AT PROJECT COMPLETION. <br />35.GENERAL CONTRACTOR WILL BE HELD FULLY RESPONSIBLE FOR ALL COORDINATION OF SCOPE <br />OF WORK BETWEEN ARCHITECTURAL & ENGINEERING DWGS. THE MOST COSTLY SCOPE OF WORK <br />WILL BE ASSUMED @ NON-COORDINATED ISSUES. GENERAL CONTRACTOR TO COORDINATE WITH <br />" BSB DESIGN " TO RESOLVE CONFLICTS PRIOR TO THE COMMENCEMENT OF THE WORK. <br />36.THE GENERAL CONTRACTOR, SUBCONTRACTOR, OR TENANT'S VENDOR MUST CERTIFY THAT ALL <br />MATERIALS AND EQUIPMENT USED OR INSTALLED ON THIS JOB ARE FREE OF ANY ASBESTOS <br />CONTAINING MATERIALS ("ACM") OR POLYCHLORINATED BIPHENYL ("PCB'S"). <br />37.PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE FOLLOWING DOCUMENTS MUST BE <br />SUBMITTED TO THE LANDLORD: A. CONTRACTOR'S INSURANCE CERTIFICATE. B. A COPY OF <br />BUILDING PERMIT. C. A COPY OF CONTRACT AGREEMENT BETWEEN TENANT/LANDLORD & <br />CONTRACTOR. D. A COMPLETE PROJECT TEAM DIRECTORY WITH EMERGENCY PHONE NUMBERS. <br />E. A PROJECT SCHEDULE NOTING CRITICAL PATH ITEMS AND TARGET COMPLETION DATE. <br />38.G.C. SHALL HAVE A FIELD OFFICE WITH A TABLE & CHAIRS FOR WEEKLY MEETINGS. CONTRACTOR <br />WILL BE REQUIRED TO HAVE A LAPTOP WITH AN E-MAIL CONNECTION. CONTRACTOR WILL BE <br />REQUIRED TO TAKE WEEKLY DIGITAL PHOTOS OF THE PROJECT AT LOCATIONS SELECTED BY <br />"BSB DESIGN" PHOTOS WILL BE DISTRIBUTED WEEKLY. <br />39.CONTRACTOR IS RESPONSIBLE FOR WEEKLY PROJECT MEETING MINUTES WHICH SHALL REFLECT <br />THE ISSUES RELATED TO THE PROJECT, INCLUDING ACTION ITEMS WITH DUE DATES. <br />40.ALL INDOOR FURNITURE PLACED IN THE ATRIUM AREA MUST HAVE THE MATERIALS FROM WHICH <br />THEY ARE MADE APPROVED BY THE FIRE DEPARTMENT, IF REQUIRED BY PROJECT. <br />1.PROVIDE FIRE-RESISTANT-RATED CONSTRUCTION AS REQUIRED, CBC 2022 CHAPTER 6. <br />2.FIRE-RESISTANT-RATED CONSTRUCTION SHALL COMPLY WITH CBC 2022 CHAPTER 7. <br />3.THROUGH PENETRATIONS AND MEMBRANE PENETRATIONS OF HORIZONTAL ASSEMBLIES AND <br />FIRE-RESISTANCE-RATED WALL ASSEMBLIES TO COMPLY WITH CBC SECTION 714. <br />4.OPENING ASSEMBLIES INTO FIRE-RESISTANT-RATED CONSTRUCTION TO COMPLY WITH CBC <br />SECTION 716. PROVIDE THE REQUIRED FIRE RESISTANCE RATING TO DOOR (CBC TABLE 716.1(2)), <br />AND WINDOW ASSEMBLIES (TABLE 716.1(3)), OPENING INTO FIRE RATED WALLS. <br />5.PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A10BC <br />WITHIN 75 FEET TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR AND ANY <br />ADDITIONAL FIRE EXTINGUISHERS AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. FIRE <br />EXTINGUISHERS SHALL ALSO BE PROVIDED DURING CONSTRUCTION. <br />6.EXTEND AND MODIFY SPRINKLER & LIFE-SAFETY SYSTEMS AS REQUIRED BY CONSTRUCTION. <br />CONTRACTOR SHALL SUBMIT PLANS FOR APPROVAL AND SEPARATE PERMIT DIRECTLY TO THE <br />DEPARTMENT OF BUILDING AND SAFETY, PRIOR TO INSTALLATION. <br />7.SPRINKLERS: THE CONTRACTOR SHALL SUBMIT THE SPRINKLER LAYOUT (INDICATING LOCATIONS <br />AND TYPE OF ALL SPRINKLER HEADS) TO " BSB DESIGN", FOR REVIEW, BEFORE BUILDING <br />DEPARTMENT SUBMITTAL OR FABRICATION OF PIPING. SPRINKLER LAYOUT DRAWINGS SHALL BE <br />SUBMITTED IN THE FORM OF A REFLECTED CEILING PLAN, INDICATING OTHER PERTINENT ITEMS <br />TO BE INSTALLED IN THE CEILING (I.E., LIGHT FIXTURES, SPEAKERS, H.V.A.C. DIFFUSERS, EXIT <br />SIGNS, ETC.). ALL SPRINKLER HEADS IN GYPSUM BOARD CEILINGS, SOFFITS, ETC., SHALL BE A <br />FULLY CONCEALED TYPE U.O.N. WITH COVERPLATE TO MATCH FINISH ON ADJACENT GYPSUM <br />BOARD CEILING. ALL CONFLICTS SHALL BE INDICATED ON THE SUBMITTED SHOP DRAWINGS. <br />8.THE FIRE PROTECTION WORK SHALL BE PERFORMED ON A DESIGN-BUILD BASIS. THE <br />DESIGN-BUILD FIRE PROTECTION CONTRACTOR SHALL FURNISH AND INSTALL ALL MODIFICATIONS <br />TO THE EXISTING FIRE SPRINKLER SYSTEM TO MEET ALL APPLICABLE LOCAL AND STATE CODE <br />REQUIREMENTS. SPRINKLER HEADS SHALL BE DROPPED INTO ALL SUSPENDED CEILING AREAS. <br />UPGRADE OF EXISTING SYSTEM SHALL CONFORM WITH EXISTING/PROPOSED BUILDING <br />OCCUPANCY CLASSIFICATION. <br />9.THE CONTRACTOR SHALL INCLUDE THE COST OF ANY HYDRAULIC TESTING OF THE FIRE <br />SPRINKLER SYSTEM REQUIRED BY ANY GOVERNMENT AGENCY. <br />10.THE PATH OF TRAVEL TO AND WITHIN EXITS IN THIS BUILDING SHALL BE IDENTIFIED BY EXIT SIGNS <br />CONFORMING TO THE REQUIREMENTS OF CBC 2022 SECTION 1013. EXIT SIGNS SHALL BE READILY <br />VISIBLE FROM ANY DIRECTION OF APPROACH. <br />11.EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF <br />EGRESS TRAVEL. NO POINT SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN. <br />PROVIDE AS REQUIRED. ADVISE "BSB DESIGN" OF ADDITIONAL EXIT SIGNS. EXIT SIGNS SHALL BE <br />ELECTRICALLY ILLUMINATED AND THE LIGHT SOURCE SHALL BE ENERGIZED FROM SEPARATE <br />CIRCUITS. ILLUMINATION SHALL NORMALLY BE PROVIDED BY THE PREMISES WIRING SYSTEMS. IN <br />THE EVENT OF THIS SYSTEM'S FAILURE, ILLUMINATION SHALL BE AUTOMATICALLY PROVIDED <br />FROM AN EMERGENCY SYSTEM. EMERGENCY LIGHTING SHALL GIVE A VALUE OF FIVE <br />FOOTCANDLES AT FLOOR LEVEL (CBC 2022 CHAPTER 10). <br />12.WHENEVER THE BUILDING IS OCCUPIED, EXIT SIGNS SHALL BE LIT SO THAT THEY ARE CLEARLY <br />VISIBLE. <br />13.PROVIDE EXIT SIGNS WITH MINIMUM 6" HIGH BLOCK LETTERS WITH 3/4" STROKE ON A <br />CONTRASTING BACKGROUND. CONTRACTOR TO COORDINATE THE LOCATION OF ADDITIONAL EXIT <br />SIGNS ON PLANS AND VERIFY WITH "BSB DESIGN" (CBC 2022 CHAPTER 10). <br />14.ALL INTERIOR FINISHES SHALL CONFORM WITH CBC 2022 CHAPTER 8. <br />15.INTERIOR WALL AND CEILING FINISHES SHALL COMPLY WITH CBC 2022 TABLE 803.13. <br />16.ACOUSTICAL CEILING SYSTEMS THAT ARE PART OF FIRE-RESISTANCE-RATED CONSTRUCTION <br />SHALL COMPLY WITH CBC 2022 CHAPTER 7. <br />17.DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME RETARDANT. CERTIFICATION <br />THEREOF SHALL BE PROVIDED. EXITS, EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS AND <br />EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED BY DECORATIVE MATERIAL (CBC 2022 <br />CHAPTER 8). <br />18.EXIT PATH LIGHTING OF ONE FOOTCANDLE SHALL BE PROVIDED AT STAIRWAY, HALLWAY, EXIT <br />PASSAGEWAY, AND EGRESS TO A PUBLIC WAY WHENEVER THE BUILDING IS OCCUPIED. (CBC 2022 <br />CHAPTER 10). <br />19.FIRE AND/OR SMOKE DAMPER ASSEMBLIES, INCLUDING SLEEVES, AND INSTALLATION <br />PROCEDURES SHALL BE APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. <br />20.AN EXIT WALKWAY WITH A MINIMUM WIDTH OF 44" SHALL BE MAINTAINED CONTINUOUSLY TO A <br />PUBLIC WAY (CBC 2022 CHAPTER 10). <br />21.ALL CONTROLLED ACCESS DEVICES (I.E. CARD READER) AND DOOR HARDWARE SHALL BE AN <br />APPROVED COMPONENT OF THE LIFE-SAFETY SYSTEM EGRESS. <br />22.EXIT DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL WHEN SERVING AN OCCUPANT <br />LOAD OF 50 OR MORE, AND IN GROUP "H" OCCUPANCY, CBC CH. 10. <br />23.SHAFT ENCLOSURES SHALL COMPLY WITH CBC 2022 SECTION 713. <br />24.DOORS SHALL BE 3'-0" IN WIDTH MINIMUM, AND 7'-0" IN HEIGHT, MINIMUM. <br />25.ALL EXIT DOORS SHALL COMPLY WITH CBC 2022 1010. <br />26.EGRESS DOORS SHALL BE SIDE-HINGED SWINGING. EXIT DOORS SHALL SWING IN THE DIRECTION <br />OF EXIT TRAVEL WHEN SERVING AN OCCUPANT LOAD OF 50 OR MORE, OR A GROUP "H" <br />OCCUPANCY (CBC 2022 SECTION 1010.1.2). <br />27.EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, OR <br />SPECIAL KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICES SHALL BE OF AN APPROVED TYPE <br />(CBC 2022 CHAPTER 10). <br />28.KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A <br />SINGLE DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR <br />ADJACENT TO THE DOOR STATING "THIS DOOR MUST REMAIN UNLOCKED WHEN SPACE IS <br />OCCUPIED". CBC 2022 1010.1.9.4. <br />29.DOORS AND FRAMES OF FIRE ASSEMBLIES ARE TO HAVE PERMANENTLY AFFIXED LABELS FOR <br />THE FIRE RATING. <br />30. INTERIOR WALL AND CEILING FINISHES SHALL BE OF THE FOLLOWING FLAME SPREAD CLASSIFICATIONS: <br />SEC 803.1 <br /> CLASS A:FLAME SPREAD 0-25 SMOKE-DEVELOPED 0-450 <br /> CLASS B:FLAME SPREAD 26-75 SMOKE-DEVELOPED 0-450 <br /> CLASS C:FLAME SPREAD 76-200 SMOKE-DEVELOPED 0-450 <br />21.PROVIDE 5/8" THICK WATER RESISTANT GYPSUM BOARD BY USG TYPE 'XP' IN ALL TOILET ROOMS <br />AND JANITOR CLOSETS. IF THE TOILET ROOM WALLS PROPOSE 3/8" THICK OR MORE STONE WALL <br />TILES, THEN CONTRACTOR SHALL PROVIDE CEMENT ROCK WALL BOARD IN LIEU OF WATER <br />RESISTANT GYPSUM BOARD. <br />22.CONTRACTOR SHALL COORDINATE WITH FURNITURE VENDOR TO SIGN OFF ON WALL LAYOUT AND <br />ELECTRICAL LAYOUT WHERE NEW / RELOCATED SYSTEMS FURNITURE OCCURS. <br />23.AT RESTROOMS, CONTRACTOR SHALL BLOCK IN WALL TO ACCOMMODATE PLUMBING FIXTURES & <br />ACCESSORIES (I.E. TOILET DISPENSER). <br />24.CONTRACTOR SHALL REFINISH ANY BLEMISHED DOORS, OR REPLACE SAID DOOR IF NOT ABLE TO <br />REFINISH. <br />25.ALL INTERIOR PARTITIONS SHALL BE TAPED SMOOTH AND SANDED TO RECEIVE PAINT OR WALL <br />COVERING. <br />26.PROVIDE EXTRA STUDS AS REQUIRED TO MOUNT ELECTRICAL OR MECHANICAL CONTROLS. <br />27.WHERE PARTITIONS OF DIFFERENT FIRE RATINGS INTERSECT, THE HIGHEST RATED PARTITION <br />SHALL CONTINUE THROUGH. MAINTAIN PARTITION FIRE RATING BEHIND RECESSED FIRE <br />EXTINGUISHER CABINETS. <br />28.ALL PIPE AND CONDUIT PENETRATIONS THRU 2 HR. RATED OR MORE PARTITIONS. FLOORS, ROOF, <br />ETC. SHALL BE SEALED WITH A RESPECTIVELY RATED FIRE BARRIER PENETRATION SEALING <br />SYSTEM BY 3M OR U.L. APPROVED EQUAL. <br />29.SHOULD CONDITIONS OCCUR WHERE A WALL IS UNABLE TO GO STRAIGHT UP TO STRUCTURE DUE <br />TO DIPPING, DUCTWORK, ETC., THE PARTITION (GYPSUM BOARD AND FRAMING) MAY JOG <br />HORIZONTALLY ABOVE THE CEILING TO AVOID THE PROBLEM. RATED WALL INTEGRITY SHALL BE <br />MAINTAINED. <br />GENERAL NOTES (CONT.) <br />41.CONTRACTOR SHOULD NOT SCALE DRAWINGS, ALL NOTED DIMENSIONS GOVERN. LARGE SCALE <br />DETAILS GOVERN OVER SMALLER SCALE DETAILS. <br />42.CONTRACTOR TO PROVIDE FLOOR AND SLAB PATCH AT FLOOR FOR ALL PENETRATIONS. <br />43.CONTRACTOR TO PROVIDE CODE COMPLIANT FIRE STOPPING @ ALL NEW FLOOR PENETRATIONS <br />THROUGHOUT WITH PATCH TO MAINTAIN EXISTING FIRE RATING OF FLOOR SLAB. <br />44.WITHIN AREA OF WORK, CONTRACTOR SHALL SURVEY ALL EXISTING FINISHED SURFACES TO <br />REMAIN SUCH AS CORNER BEADS, STOPS, CEILING GRID & TILES, PLASTER CEILING, FINISHED <br />FLOOR SLABS, ETC. FOR CHIPS, CRACK HOLES, DAMAGED SURFACES, AND ANY OTHER DEFECTS <br />CAUSING AN APPEARANCE DIFFERENT FROM A NEW FIRST CLASS FINISHED REPAIRING, THEN <br />CONTRACTOR SHALL REMOVE EXISTING AND INSTALL NEW SURFACES TO THE SATISFACTION OF <br />"BSB DESIGN" <br />45.CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL CONSTRUCTION CLEANUP, CLEANING OF ALL <br />INTERIOR GLASS SURFACES AND SHALL PROVIDE OFFICE CLEANUP SERVICE(S) (CARPET, WOOD <br />SURFACES, ETC.) FOR THE LAST MINUTE CLEANUP AT ODD HOURS (EVENINGS, WEEKENDS, ETC.). <br />ARRANGEMENTS SHALL BE MADE TO HAVE ALL EXTERNAL WINDOW SURFACES CLEANED WITHIN <br />TWO (2) WEEKS OF MOVE-IN/OCCUPANCY. THE G.C. SHALL COORDINATE ALL CLEANUP WITH <br />BUILDING REPRESENTATIVES AND " BSB DESIGN". <br />46.WHERE EXISTING ROOF, ETC. ARE DAMAGED DUE TO DEMOLITION OR NEW CONSTRUCTION, THAT <br />AREA SHALL BE REPAIRED TO MATCH EXISTING. <br />47.ALL ROOFING WORK SHALL BE PERFORMED BY A CERTIFIED/LICENSED ROOFING CONTRACTOR <br />AND FOLLOW MANUFACTURERS RECOMMENDATIONS. <br />1.ALL NEW DOORS SHALL BE EDGE BANDED WITH THE SAME MATERIAL AS THE DOOR FACE, <br />UNLESS OTHERWISE NOTED. <br />2. G.C. IS RESPONSIBLE TO VERIFY THE QUANTITY AND CONDITION OF ALL EXISTING TO REMAIN <br />DOORS PRIOR TO BID. TO INCLUDE UNDERCUT DIMENSIONS. <br />3.ALL HARDWARE SHALL BE OF LEVER TYPE TO COMPLY WITH ACCESSIBILITY REQUIREMENTS, <br />UPGRADE EXISTING AS REQUIRED. <br />4.ALL NEW DOORS TO MATCH EXISTING, U.O.N. <br />5.PAINT AT DOORS & FRAMES TO BE SEMI-GLOSS FINISH U.O.N. <br />6.REFURBISH EXISTING DOOR ASSEMBLIES AT REMODEL AREAS U.O.N., PROVIDE MISSING <br />HARDWARE AS REQUIRED. <br />7.THE BOTTOM 10" OF DOORS, EXCEPT AUTOMATIC AND SLIDING DOORS, SHALL HAVE A SMOOTH, <br />UNINTERRUPTED SURFACE. <br />8.G.C. IS RESPONSIBLE FOR VERIFYING & COORDINATING THICKNESS OF EXISTING VS. NEW WALL <br />AT RELOCATED DOOR FRAMES PRIOR TO BID. <br />9.CONTRACTOR TO UNDERCUT ALL DOORS AS REQUIRED FOR PROPER OPERATION. <br />10.THE FRAME OF FIRE ASSEMBLIES ARE TO HAVE THE SAME RATING AS DOORS. <br />11.PAINT FINISH ON ALL PAINT GRADE DOORS, CASEWORK AND MILLWORK WHERE SPECIFIED IS TO <br />BE SPRAYED-ON (OFF SITE) SEMI-GLOSS ENAMEL FINISH. <br />12.G.C. TO UNDERCUT ALL OFFICE DOORS AS REQUIRED WHERE CARPET OCCURS. <br />13.EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A <br />KEY OR SPECIAL KNOWLEDGE OR EFFORT (CBC 2022, 1010.1.9) AND WITH ONE OPERATION. <br />14.DEAD BOLTS SHALL CONTAIN HARDENED INSERT OR EQUIVALENT. <br />15.BOLTS OF LOCKS WHICH AUTOMATICALLY ACTIVATE 2 OR MORE DEAD BOLTS SHALL EMBED 1/2" <br />MIN. <br />16.STRAIGHT DEAD BOLTS SHALL HAVE A MIN. THROW OF 1" W/ A 5/8" MIN. EMBEDMENT. <br />17.HOOK OR EXPANDING LUG DEAD BOLTS SHALL HAVE A MIN. THROW OF 3/4". <br />DOOR AND HARDWARE NOTES <br />CLIENT: <br />SUBMITTAL <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />B <br />S <br />B <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />, <br /> <br />i <br />n <br />c <br />. <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />a <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />JOB NO. <br />DATEREVISION <br />SHEET TITLE <br />SHEET NO. <br />08.08.2023PLANNING SUBMITTAL <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />21 <br />3 <br />0 <br /> <br />E <br />. <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br /> <br /># <br />2 <br />0 <br />0 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />- <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br /> <br />T <br />I <br />CM220584.00 <br />21 <br />3 <br />0 <br /> <br />E <br />. <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />CL <br />I <br />E <br />N <br />T <br />: <br />PR <br />O <br />J <br />E <br />C <br />T <br />: <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />1ST PC SUBMITTAL - BUILDING <br />PLAN CHECK RESUBMITTAL <br />02.08.2024 <br />PLAN CHECK RESUBMITTAL 09.09.2024 <br />970 W. 190TH. ST., SUITE 250, TORRANCE, CA 9050 <br />O: 310.217.8885 <br />BSBDESIGN.COM <br />PLAN CHECK RESUBMITTAL 10.17.2024 <br />B PLAN CHECK CORRECTIONS 10.17.2024 <br />B <br />REN. 11/30/25 <br />2130 E 4th St <br />2/11/2025