Laserfiche WebLink
GFCI <br />AFCI <br />VS <br />2 <br />MS <br />D <br />(N) <br />WH <br />DWREF <br />(G <br />A <br />S <br />) <br />(N) <br />WH <br />REF <br />AFCI <br />AFCI GFCI <br />GF <br />C <br />I <br />AF <br />C <br />I <br />AFCIAFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />GFCI GFCIGFCI <br />AFCI <br />AFCI AFCI <br />AF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />VS <br />MS <br />GFCI <br />GF <br />C <br />I <br />GF <br />C <br />I <br />VS <br />D <br />D <br />MS <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />GF <br />C <br />I <br />(N) <br />WH <br />DWREF <br />(G <br />A <br />S <br />) <br />UNIT PLAN KEYNOTES <br />WINDOW SCHEDULE <br />(N) MAIN ELECTRICAL PANEL 200AMP <br />DUAL METERS. MIN. 20' UFER GROUND, <br />PROVIDE WITH A TYPE 1 SURGE- <br />PROTECTIVE DEVICE (SPD) <br />A VINYL SLIDER WINDOW: 5'-0"w x 4'-0"h <br />UNIT PLAN LEGEND <br />DOOR SCHEDULE <br />L.E.D. RECESSED LIGHT FIXTURE <br />RECESED LIGHTS SHALL BE AIR-TIGHT AND IC RATED <br />SMOKE DETECTOR HARDWIRED w/ 10-YEAR <br />BATTERY BACK UP <br />VANITY WALL LIGHT <br />CEILING MOUNTED LINEAR BOX 1X4 LIGHT FIXTURE <br />NEW 2X4 INTERIOR WALL <br />NEW 2X4 EXTERIOR WALL / INFILL <br />WITH INSULATION PER T-24 <br />COMBINATION" SD/CM DETECTOR ALARM <br />HARDWIRED w/ BATTERY BACK UP <br />EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT w/ VENT 50 <br />CFM MIN. INTERMITTENT W/ HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% <br />ALL BATHROOM EXHAUST FAN MUST BE CONTROLLED BY A HUMIDISTAT WHICH <br />SHALL BE READILY ACCESSIBLE (CGDSC 4.506) <br />GROUND FAULT CIRCUIT INTERRUPT PROTECTOR <br />IN ALL WET AREAS (ENTIRE CIRCUIT) <br />ARC FAULT CIRCUIT INTERRUPT PROTECTOR IN <br />ALL BEDROOMS (ENTIRE CIRCUIT) <br />SWITCH W/ MOTION SENSOR (VACANCY SENSOR) <br />TWO-WAY SWITCH <br />3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR <br />2 SINGLE FLUSH INTERIOR DOOR: 28"w x 80"h <br />2.1 SINGLE FLUSH INTERIOR DOOR: 30"w x 80"h <br />3 ENTRANCE DOOR: 36"w x 80"h <br />5 SINGLE FLUSH INTERIOR DOOR: 24"w x 80"h <br />6 SLIDING INTERIOR DOOR: 48"w x 80"h <br />1 <br />2 <br />3 <br />4 <br />1. VERIFY ALL APPLIANCE EQUIPMENT AND FIXTURE DIMENSIONS AND INSTALLATION REQUIREMENTS <br />PRIOR TO CASEWORK FABRICATION INSTALLATION. <br />2. FINISH END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE. PRIME & PAINT <br />EXPOSED GYP. BD. WALL TO MATCH WALLS. INSTALL MATCHING BASE BD. <br />3. EXTEND FLOORING UNDER APPLIANCES RESTING ON FLOOR. <br />4. SHOWER COMPARTMENTS AND WALLS ABOVE BATH TUBS WITH INSTALLED SHOWER HEADS SHALL <br />BE FINISHED WITH A SMOOTH, NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES <br />ABOVE THE DRAIN INLET. <br />5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, UNO. <br />6. CEILING HEIGHTS INDICATED ARE FROM TOP OF SLAB OR FLOOR FILL TO BOTTOM OF FINSH. <br />7. SMOKE DETECTORS WILL BE PROVIDED PER CHAPTER 3 CRC. THE SMOKE DETECTOR WILL BE HARD <br />WIRED WITH 10-YEAR LIFE BATTERY BACK-UP IN A SEALED COMPARTMENT AND LOCATED (1) IN <br />EACH BEDROOM, HALLWAYS OUTSIDE BEDROOMS, AND ON EACH STORY. SMOKE DETECTOR ALARM <br />SOUND MUST BE AUDIBLE IN SLEEPING AREAS WHICH MAY REQUIRE INTERCONNECTED SMOKE <br />DETECTORS WITHIN THE UNIT. SEE UTILITY PLANS FOR LOCATIONS. INSTALL AND LOCATE PER <br />MFGR. LISTED REQUIREMENTS. <br />8. PROVIDE CARBON MONOXIDE DETECTOR ALARMS ON CEILINGS OR WALLS OUTSIDE SLEEPING <br />ROOMS PER CHAPTER 3 CRC. <br />9. BATHROOM FANS MUST BE ENERGY STAR W/ HUMIDISTAT CONTROLLER AND MUST BE DUCTED TO <br />THE EXTERIOR OF THE BUILDING. <br />10. ALL NEW WINDOWS TO BE DUAL PANES TO MEET CURRENT ENERGY STANDARD REQUIREMENTS. <br />11. USE 2x6 STUDS FOR PLUMBING WALL IF NECCESSARY <br />12. CEILING HEIGHTS INDICATED ARE MEASURED FROM FINISH FLOOR TO BOTTOM OF CEILING FINISH. <br />13. PROVIDE BACKING FOR ALL ACCESSORIES, FIXTURES AND WINDOW COVERINGS. <br />14.NO HEATING, COOLING, OR INSULATION IN GARAGE <br />15.PROVIDE TWO LAYERS OF GRADE D OR 60-MINUTE GRADE D PAPER OVER ALL WOOD BASE <br />SHEATHING AT EXTERIOR WALLS. <br />16.A MINIMUM 26 GAUGE, CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH A MINIMUM <br />VERTICAL FLANGE OF 3½ INCHES SHALL BE PROVIDED AT OR BELOW FOUNDATION PLATE LINE ON <br />EXTERIOR STUD WALLS. SCREED SHALL BE A MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES <br />ABOVE PAVED AREAS. (CRC R703.7.2.1) <br />17.ACCESS TO ATTIC FURNACE MUST BE WITHIN 20' OF UNIT AND SHALL HAVE A CONTINUOUS SOLID <br />WALKWAY AT LEAST 30" x 30" WIDE. A SWITCH CONTROL IS ALSO REQUIRED (CMC 304.4.1) <br />18.PROVIDE GFI PROTECTION TO ALL 120 VOLT, 15 AND 20 AMP RECEPTACLES INSTALLED AT <br />OUTDOORS, IN BATHROOM, AT COUNTER TOP SURFACES AND GARAGES. (CEC2108(a)). <br />19.OUTLETS TO BE MAX. 12' APART ALONG WALLS AND 6' FROM DOORS AND CORNERS. <br />GENERAL NOTES <br />5 <br />6 <br />0.3 U-FACTOR PER TITLE-24 <br />0.22 SHGC PER TITLE-24 <br />CONTRACTOR TO VERIFY SIZE <br />ALL NEW WINDOWS IN NEW BEDROOMS SHALL HAVE EMERGENCY <br />RESCUE WINDOWS OR DOORS (CHAPTER 3, 2022 CRC) <br />a) MINIMUM NET CLEAR OPENING OF 5.7 SQ. FT. <br />b) MINIMUM NET CLEAR OPENING WIDTH OF 20". <br />c) MINIMUM NET CLEAR HEIGHT OF 24" <br />d) WINDOW CLEAR OPENING LESS THAN 44" ABOVE THE FLOOR <br />LIGHT: (2022 CRC) EVERY SPACE INTENDED FOR HUMAN <br />OCCUPANCY SHALL BE PROVIDED w/ NATURAL LIGHT BY MEANS <br />OF EXTERIOR GLAZED OPENINGS IN ACCORDANCE w/ CH3 CRC OR <br />SHALL BE PROVIDED w/ ARTIFICAL LIGHT IN ACCORDANCE w/ <br />CH3 CRC. EXTERIOR GLAZED OPENINGS SHALL OPEN DIRECTLY <br />ONTO A PUBLIC WAY OR ONTO A YARD OR COURT IN <br />ACCORDANCE w/ CH3 CRC. <br />NATURAL VENTILATION: <br />VENTILATION AREA REQUIRED. (2022 CRC) BATHROOMS (2022 CRC) <br />EXTERIOR WALL <br />SCONCE LIGHT <br />NEW KITCHEN EXHAUST FAN MIN. 280 CFM <br />SHALL BE DUCTED TO THE OUTSIDE <br />WHOLE BUILDING VENTILATION. CONTINUOUS FAN FLOW. <br />0.01 * 1000 SF + 7.5 * (2+1) = 32.5 CFM (MINIMUM) <br />(N) AC / HEATING CONDENSER <br />MOUNTED ON THE 3" MIN. <br />CONC. PAD OR APPROVED <br />MANUFACTURED PAD <br />MOUNTED TO THE GROUND <br />INVERTER AND METERING EQUIPMENT AND <br />PATHWAY FOR ROUTING FROM THE SOLAR <br />ZONE TO THE MAIN SERVICE PANEL. 1-INCH <br />CONDUIT LINE SHALL BE PROVIDED. <br />7 <br />8 <br />9 <br />10 <br />(N) HEAT PUMP WATER HEATER <br />1'' GAS LINE REQ'D IF GAS LINE IS +20' <br />(N) 22X30 ATTIC ACCESS <br />(N) LANDING. 1 1/2" BELOW THRESHOLD. <br />MINIMUM 36" IN DEPTH. UNO. <br />MIN. 2% SLOPE AWAY FROM BUILDING. <br />32"MIN.CLR.INTERIOR DOOR SEE NOTE ON <br />"AGING-IN-PLACE" ON SHEET A.09 <br />(N) AC / HEATING CONDENSER MOUNTED <br />ON THE 3" MIN. CONC. PAD OR APPROVED <br />MANUFACTURED PAD MOUNTED TO THE <br />GROUND <br />PHOTOCELL CONTROL / MOTION SENSOR <br />120-V WATERPROOF RECEPTACLE W/COVER <br />(INDICATES NEW DOORS ONLY) <br />(INDICATES NEW WINDOWS ONLY) <br />WHOLE HOUSE FAN; <br />REFER TO T-24, (1400 CFM) <br />B VINYL SLIDER WINDOW: 3'-0"w x 3'-0"h <br />F VINYL SLIDER WINDOW: 36"w x 12"h <br />(OBSCURED GLASS) <br />(N) ADU ELECTRICAL SUB-PANEL 125AMP, <br />PROVIDE WITH A TYPE 1 SURGE- <br />PROTECTIVE DEVICE (SPD) <br />1.1 <br />11 MIN. 4”DIA. SMOOT METAL DUCT TO THE <br />OUTSIDE, EQUIPPED WITH A BACK-DRAFT <br />DAMPER. DUCT LENGTH IS LIMITED TO 14’ <br />WITH 2 ELBOWS. <br />12 LUMINAIRES LOCATED ABOVE A BATHTUB OR <br />SHWR SHALL BE LISTED FOR WET LOCATIONS. <br />8 SLIDING DOOR W/ FROSTED GLASS: 72"w x 80"h <br />9 DOUBLE LOUVER DOOR: 48"w x 80"h <br />10 EXTERIOR DOOR: 28"w x 80"h <br />11 SINGLE FLUSH INTERIOR DOOR: 32"w x 80"h <br />1 <br />1 <br />2X8 BACKING FOR GRAB BAR INSTALLATION <br />SEE NOTE ON "AGING-IN-PLACE" ON SHEET A.09 <br />1 <br />13 APPROVED PRE-FABRICATED SHOWER <br />ENCLOSURES WALL PANELS WITH <br />FACTORYINSTALLED REINFORCEMENT FOR <br />GRAB BARS. <br />14 SMOOTH, NON-ABSORBENT SURFACE TO A <br />HEIGHT NOT LESS THAN 72 INCHES ABOVE <br />THE DRAIN INLET <br />1 <br />DIMMER SWITCH 1 <br />1 <br />A.06 <br />5 <br />A.06 <br />2 <br />A.06 <br />1 <br />A.06 <br />6 <br />BEDROOM-2 <br />W.I.C <br />BEDROOM-1 <br />BATH-2 <br />BATH-1 <br />CL <br />O <br />S <br />E <br />T <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />LIVING ROOM <br />DINING ROOM <br />KITCHEN <br />A <br />x <br />2' <br /> <br />- <br /> <br />8 <br />" <br />w <br />6' <br /> <br />- <br /> <br />8 <br />" <br />h <br />RI <br />G <br />H <br />T <br /> <br />H <br />A <br />N <br />D <br />11 <br />17'-0 1/2" <br />5'-8"11'-4 1/2" <br />EQ EQ <br />11 <br />' <br />- <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />5' <br />- <br />1 <br />" <br />5' <br />- <br />3 <br /> <br />1 <br />/ <br />2 <br />" <br />8' <br />- <br />8 <br />" <br />30 <br />' <br />- <br />1 <br />" <br />2 <br />5 <br />2.1 <br />11 <br />3 <br />x <br />6' <br /> <br />- <br /> <br />0 <br />" <br />w <br /> <br />6 <br />' <br /> <br />- <br /> <br />8 <br />" <br />h <br />SL <br />I <br />D <br />I <br />N <br />G <br /> <br />D <br />O <br />O <br />R <br />AA <br />6 <br />6 <br />x 2' - 4"w6' - 8"h <br />RIGHT HAND <br />F A <br />x 2' - 0"w6' - 8"h <br />LEFT HAND <br />10 <br />x <br />2' <br /> <br />- <br /> <br />8 <br />" <br />w <br /> <br />6 <br />' <br /> <br />- <br /> <br />8 <br />" <br />h <br />LE <br />F <br />T <br /> <br />H <br />A <br />N <br />D <br />x <br />2' <br /> <br />- <br /> <br />6 <br />" <br />w <br /> <br />6 <br />' <br /> <br />- <br /> <br />8 <br />" <br />h <br />RI <br />G <br />H <br />T <br /> <br />H <br />A <br />N <br />D <br />F <br />A <br />x 3' - 0"w6' - 8"h <br />RIGHT HAND <br />B <br />x <br />4' <br /> <br />- <br /> <br />0 <br />" <br />w <br /> <br />6 <br />' <br /> <br />- <br /> <br />8 <br />" <br />h <br />SL <br />I <br />D <br />I <br />N <br />G <br /> <br />D <br />O <br />O <br />R <br />x <br />4' <br /> <br />- <br /> <br />0 <br />" <br />w <br /> <br />6 <br />' <br /> <br />- <br /> <br />8 <br />" <br />h <br />SL <br />I <br />D <br />I <br />N <br />G <br /> <br />D <br />O <br />O <br />R <br />8 <br />43'-3 1/2" <br />12'-10 1/2" 2'-8" 9'-6 1/2"18'-3" <br />1'-2" <br />1' <br />- <br />6 <br />" <br />1' <br />- <br />6 <br />" <br />1'-2" <br />1'-2" <br />1' <br />- <br />6 <br />" <br />19 <br />' <br />- <br />8 <br />" <br />9' <br />- <br />1 <br />0 <br />" <br />9' <br />- <br />1 <br />0 <br />" <br />8'-0"24'-2 1/2" <br />12'-4"5'-11" 5'-11 1/2"4'-0" 4'-0" <br />2'-8" <br />1'-6" <br />2' <br />- <br />4 <br />" <br />EQ <br /> <br />E <br />Q <br />3' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />5 <br />' <br />- <br />8 <br />" <br /> <br />5 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />4'-0 1/2"14'-9"9'-0" <br />x 2' - 4"w6' - 8"h <br />LEFT HAND <br />4' <br />- <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />6 <br />" <br />10 <br />' <br />- <br />3 <br />" <br />15 <br />" <br /> <br />1 <br />5 <br />" <br />15 <br />" <br /> <br />1 <br />5 <br />" <br />27" <br />4 <br />A.06 <br />3 <br />A.06 <br />ENTRY <br />PORCH <br />51 SF <br />(N) PATIO <br />COVER 115 SF <br />(CLR.) <br />12'-6" <br />(C <br />L <br />R <br />. <br />) <br />10 <br />' <br />- <br />4 <br /> <br />1 <br />/ <br />2 <br />" <br />(C <br />L <br />R <br />. <br />) <br />9' <br />- <br />1 <br />1 <br />" <br />5' <br />- <br />8 <br /> <br />1 <br />/ <br />2 <br />" <br />(CLR.) <br />11'-0" <br />6 <br />9 <br />DOUBLE DOOR <br />4' 0" w X 6' 8"h <br />CONC. <br />LANDING <br />4 <br />2% <br />-3 <br />" <br />2% <br />-3 <br />" <br />2% <br />1 <br />7 <br />1.1 <br />TEMPERED <br />TE <br />M <br />P <br />E <br />R <br />E <br />D <br />EGRESS <br />EG <br />R <br />E <br />S <br />S <br />2'-8" 3'-0" 3'-4 1/2" 8'-0"8'-0"18'-3" <br />1 <br />5 <br />5 <br />8 <br /> 30'' CLR. <br />TOTAL AREA: 13,3 SF <br />8 <br />26" <br />8 <br />13 <br /> 30'' CLR. <br />TOTAL AREA: 13,3 SF <br />1 <br />1 <br />14 <br />14 <br />3' <br />- <br />0 <br />" <br />DRYER <br />EXHAUST TO <br />OUTSIDE <br />11 <br />LA <br />U <br />N <br />D <br />R <br />Y <br /> <br />1 <br />1 <br />13 <br />2'-6" 6'-0" 2'-6" <br />2' <br />- <br />6 <br />" <br />4' <br />- <br />1 <br />1 <br />" <br />2' <br />- <br />6 <br />" <br />EQ EQ <br />3' <br />- <br />8 <br />" <br />3' <br />- <br />0 <br />" <br />1' <br />- <br />4 <br />" <br />2'-2" 6'-8" 3'-8" <br />2' <br />- <br />2 <br />" <br /> <br />6 <br />' <br />- <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />2 <br />' <br />- <br />2 <br />" <br />1'-6 1/2" 5'-5" 5'-5" 5'-0" 6'-0" 4'-0 1/2" <br />3' <br />- <br />3 <br />" <br /> <br />3 <br />' <br />- <br />9 <br /> <br />1 <br />/ <br />2 <br />" <br /> <br />4 <br />' <br />- <br />5 <br />" <br /> <br />4 <br />' <br />- <br />8 <br />" <br /> <br />2 <br />' <br />- <br />8 <br />" <br />12 <br />EQ EQ <br />EQ EQ <br />EQ <br />EQ <br />EQ <br />EQ <br />2'-6 1/2" 12'-0 1/2" 3'-0" <br />EQ <br /> <br />E <br />Q <br />12 <br />EQ <br />EQ <br />1 <br />7 <br />1.1 <br />109 <br />GAS <br />EXHAUST <br />CFM 280 <br />3 <br />1 <br />1 <br />D D D D D 1 <br />1 <br />TOTAL AREA = 1,000 SF <br />PUBLIC AREA = 500 SF = 50% <br />PRIVATE AREA = 500 SF = 50% <br />REQUIRED 50:50 RATIO OF COMMON TO PRIVATE AREAS <br />BEDROOM-2 <br />BATH-2 <br />W.I.C <br />BEDROOM-1 <br />BATH-1 <br />LIVING ROOM DINING ROOM <br />KITCHEN <br />HALLWAY <br />2' <br />SCALE : 1/4" = 1'-0" <br />0 4'8' <br />FLOOR AREA IS MEASURED FROM THE FACE OF STUD OF THE <br />EXTERIOR PERIMETER WALLS, EXCLUSIVE OF VENT SHAFTS AND NON- <br />HABITABLE WATER HEATER CLOSET. <br />1/4" = 1'-0"1PROPOSED DETACHED ADU -FLOOR PLAN <br />1/4" = 1'-0"2PRO. DETACHED ADU -ELECT. / LIGHT. PLAN <br />PROJECT CONTACT <br />OWNERSHIP <br />IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING <br />CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING <br />OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS <br />AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY <br />KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF <br />CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL <br />INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS <br />SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO <br />THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE <br />OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN <br />CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. <br />DESCRIPTIONDATEDELTA <br />CONSTRUCTION DOCUMENTS <br />TECHNOLOGIST <br />TAM VO, CDT, LEED AP <br />SIGNATURE <br />DATE: 04/16/2024 <br />A.05 <br />ACCESSORY <br />DWELLING UNIT <br />FLOOR PLAN & <br />ELECTRICAL / <br />LIGHTING PLAN <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />23 <br />3 <br />1 <br /> <br />N <br /> <br />B <br />E <br />N <br />T <br />O <br />N <br /> <br />W <br />A <br />Y <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />M <br />A <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br />23 <br />3 <br />1 <br /> <br />N <br /> <br />B <br />E <br />N <br />T <br />O <br />N <br /> <br />W <br />A <br />Y <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DETACHED ADU: <br />2 BEDROOMS, <br />2 BATHROOMS, <br />LIVING, KITCHEN, <br />DINING, AND <br />LAUNDRY <br /> 12/16/2023 PLANNING REVIEW <br />LOAN PHAM <br />17021 BOLERO LN <br />HUNTINGTON BEACH, CA 92649 <br />PHONE: 714-614-6344 <br />EMAIL: LOANPHAM8888@YAHOO.COM <br />KHANH DAO <br />10448 SALINAS RIVER CIR <br />FOUNTAIN VALLEY, CA 92708 <br />PHONE: (714) 390-5154 <br />CLOTHES DRYER MOISTURE EXHAUST SMOOTH METAL <br />DUCTS SHALL TERMINATE OUTSIDE THE BUILDING AND HAVE <br />A BACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14’ <br />WITH TWO ELBOWS. THIS SHALL BE REDUCED 2’ FOR EVERY <br />ELBOW IN EXCESS OF TWO OR IN ACCORDANCE WITH <br />MANUFACTURER’S INSTALLATION INSTRUCTIONS. SHOW <br />MINIMUM 4” DIAMETER, SMOOTH, METAL DUCT, AND SHOW <br />DUCT ROUTE ON PLAN. [§504.4 CMC] <br />SHOWERS AND WALLS ABOVE BATHTUBS WITH SHOWER HEADS <br />SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO A <br />HEIGHT NOT LESS THAN 6 FEET ABOVE THE FLOOR. [§R307.2 <br />CRC] <br />ALL WATER HEATER INSTALLATION LOCATIONS, REGARDLESS OF PROPOSED <br />WATER HEATING SYSTEM, SHALL HAVE: (BEES 150.0(N)1A-D) <br />A. A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN <br /> 3 FEET FROM THE WATER HEATER. <br />B. A CATEGORY III OR IV VENT, OR A TYPE B VENT <br /> WITH STRAIGHT PIPE. <br />C. CONDENSATE DRAIN THAT IS NO MORE THAN 2 <br /> INCHES HIGHER THAN THE FINISH SURFACE <br /> BELOW. <br />D. A GAS SUPPLY LINE WITH AVAILABLE CAPACITY <br /> FOR NOT LESS THAN A 200,000 BTU/HR SYSTEM. <br />CA TITLE 24 2022 - RESIDENTIAL LIGHTING <br />- ALL IN-UNIT FIXTURES TO BE HIGH EFFICACY. <br />- ALL INSEPERABLE LED'S TO BE JA8 APPENDIX APPROVED. <br />- ALL MEDIUM BASED + GU24 LED LAMPS TO BE JA8-2016-3 APPROVED (WITH MARKINGS) <br />- ALL RESESSED DOWNLIGHTS TO BE JA8 APPENDIX APPROVED <br />- DOCUMENATION FOR THE ABOVE JA8 + JA8-2016-E REQUIREMENTS SHALL BE PROVIDED DURING SUBMITTAL PROCESS. <br />- ALL FORWARD PHASE CUT DIMMERS USED WITH LED SHALL COMPLY WITH NEMA SSL 7A <br />R702.4.2 BACKER BOARDS <br />MATERIALS USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER <br />AREAS SHALL BE OF MATERIALS LISTED IN TABLE R702.4.2, AND INSTALLED IN ACCORDANCE WITH THE <br />MANUFACTURER'S RECOMMENDATIONS. <br />TABLE R702.4.2 BACKER BOARD MATERIALS <br />MATERIAL STANDARD <br />GLASS MAT GYPSUM BACKING PANEL ASTM C1178 <br />FIBER-REINFORCED GYPSUM PANELS ASTM C1278 <br />NONASBESTOS FIBER-CEMENT BACKER BOARD ASTM C1288 OR ISO 8336, CATEGORY C <br />NONASBESTOS FIBER MAT-REINFORCED ASTM C1325 <br />CEMENTITIOUS BACKER UNITS <br />CMC 304 & 904.10 <br />A. ATTIC ACCESS OPENING MINIMUM 22 X 30 INCHES; <br />B. ELECTRIC LIGHT FIXTURE AND OUTLET ADJACENT TO THE FURNACE, AND SWITCH LOCATED BY THE ACCESS OPENING; <br />C. 24-INCH WIDE WALKWAY FROM THE ACCESS OPENING TO THE EQUIPMENT; <br />D. ACTUAL WALKWAY LENGTH (MAXIMUM 20 FT); AND, <br />E. WORK PLATFORM IN FRONT OF THE SERVICE PANEL AND 30 INCHES MINIMUM DEPTH. <br />WATER HEATING. SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING <br />UNITS SHALL INCLUDE THE FOLLOWING COMPONENTS [150.0(N)]: <br />A. A DEDICATED 125V, 20A (10 AWG COPPER BRANCH CIRCUIT) ELECTRICAL RECEPTACLE THAT IS <br />WITHIN 3 FEET FROM THE WATER HEATER AND ACCESSIBLE TO THE WATER HEATER WITH NO <br />OBSTRUCTIONS. THERE SHALL BE A RESERVED SINGLE POLE BREAKER SPACE IN THE <br />ELECTRICAL PANEL LABELED "FUTURE 240V USE". <br />1) BOTH ENDS OF THE UNUSED CONDUCTOR SHALL BE LABELED WITH THE WORD <br />“SPARE”AND BE ELECTRICALLY ISOLATED. <br />A. A CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE BASE OF THE <br />INSTALLED WATER HEATER, AND ALLOWS NATURAL DRAINING WITHOUT PUMP ASSISTANCE. <br />B. DESIGNATE A SPACE AT LEAST 2.5 FT. BY 2.5 FT. WIDE AND 7 FT. TALL SUITABLE FOR THE FUTURE <br />INSTALLATION OF A HEAT PUMP WATER HEATER (HPWH). <br />ADDITIONAL MECHANICAL / PLUMBING / ELECTRICAL NOTES <br />ALL OUTLETS ARE TO BE AFCI WITH NO EXCEPTIONS. <br />ALL LIGHTS ARE HIGH EFFICACY WITH NO EXCEPTIONS. <br />ALL RECEPTACLES REQUIRED GFCI SHALL BE COMBINATION OF AFCI, GFCI (CEC 210.52(E)(1)) <br />ALL NEW RECEPTACLES IN BATHROOM WET AREAS OR OVER THE COUNTER, SHALL BE COMBINATION OF GFCI AND AFCI PER 2022 CODE <br />REQUIREMENTS. <br />EXTERIOR RECEPTACLES REQUIRED FOR DECK/PORCH SHALL BE ON AFCI, GFCI, AND W.P. <br />MINIMUM LIGHTING IS REQUIRED FOR LANDING, STEPS, DECK PER CODE, 1 FOOT CANDLE. LOCATE LIGHTING WITH SENSOR OR TIME <br />SCHEDULE SWITCH PER CODE. <br />ALL WATER HEATER INSTALLATION LOCATIONS, REGARDLESS OF PROPOSE WATER HEATING SYSTEM, SHALL HAVE: (BEES 150.0(N)1A-D) <br />A. A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER. <br />B. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE. <br />C. CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE FINISH SURFACE BELOW. <br />D. A GAS SUPPLY LINE WITH AVAILABLE CAPACITY FOR NOT LESS THAN A 200,000 BTU/HR SYSTEM. <br />ABOVE COOKING APPLIANCES LOCAL EXHAUST VENTILATION: (CMC 504.2 AND ASHRAE 62.2) <br />A. MINIMUM RATE OF 100 CFM; <br />B. MAXIMUM SOUND RATING OF 3 SONES @100 CFM <br />THE INSTALLATION OF THE DOMESTIC DRYER SHALL COMPLY WITH THE FOLLOWING CODE REQUIREMENTS: <br />A. WHERE A COMPARTMENT OR SPACE FOR DOMESTIC CLOTHES DRYER IS PROVIDED, NOT LESS THAN A 4 INCH DIAMETER <br />MOISTURE EXHAUST DUCT OF APPROVED MATERIAL SHALL BE INSTALLED. [CMC 504.3.1] <br />B. MOISTURE EXHAUST DUCTS FOR THE DRYER SHALL TERMINATE ON THE OUTSIDE OF THE BUILDING AND <br />SHALL BE EQUIPPED WITH A BACKDRAFT DUMPER. [CMC 504.3] <br />C. ENVIRONMENTAL AIR DUCT EXHAUST FROM CLOTHES DRYER SHALL TERMINATE NOT LESS THAN 3 FEET FROM A PROPERTY <br />LINE AND 3 FEET FROM OPENINGS IN ANY DIRECTION FROM OPENINGS INTO THE BUILDING. [CMC 504.5] <br />D. WHEN A DOMESTIC CLOTHES DRYER IS LOCATED IN A CLOSET, A MINIMUM OPENING OF 100 SQUARE INCHES FOR MAKEUP <br />AIR SHALL BE PROVIDED IN THE DOOR. (CMC 504.4.1) <br />BATHROOM AND LAUNDRY CLOSET EXHAUST FAN SHALL HAVE A MINIMUM EXHAUST OF 50CFM WITH HUMIDISTAT, AT 3 SONES MAX, AND <br />ENERGY STAR. EXHAUST FAN SHALL BE ON SEPARATE SWITCH. (CMC, CH. 4, CGBSC CH. 4, DIV.4.5 & CRC R303.3.1) <br />ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS <br />SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY <br />OR SIMILAR METHODS. (CGBSC 4.406.1) <br />3VIEW-3D -ADU <br />PROPOSED AREA PLAN <br />1 03/28/2024 1ST CORRECTIONS <br />1 <br />LIGHTING IN HABITABLE SPACES, INCLUDING BUT NOT LIMITED TO <br />LIVING ROOMS, DINING ROOMS, KITCHENS, AND BEDROOMS, SHALL <br />HAVE READILY ACCESSIBLE WALL-MOUNTED DIMMING CONTROLS <br />THAT ALLOW THE LIGHTING TO BE MANUALLY ADJUSTED UP AND <br />DOWN. FORWARD PHASE CUT DIMMERS CONTROLLING LED LIGHT <br />SOURCES IN THESE SPACES SHALL COMPLY WITH NEMA SSL 7A. <br />CAL. ENERGY CODE SECTION 150.0(K)2F <br />1 <br />2331 N Benton Way Unit# 2 - <br />101118534 <br />6/4/2024