CONSTRUCTION PLAN
<br />LEGEND & KEYNOTES
<br />A-2.0
<br />AS NOTED
<br />PROJECT:
<br />DATE:
<br />DRAWN:
<br />SCALE:
<br />PROJECT NO:
<br />REVIEWED:
<br />SHEET NO:
<br />SHEET TITLE:
<br />STAMP AND SIGNATURE:
<br />CONSULTANTS:
<br />DATE DESCRIPTION DELTA
<br />DRAWINGS ISSUE
<br />02/15/2024 ISSUE FOR PLANNING APPROVAL
<br />6083 Bristol Parkway
<br />Culver City, CA 90230
<br />515 South Flower St., Suite 1200
<br />Los Angeles, CA 90071
<br />18600 MacArthur Blvd., Suite 100
<br />Irvine, CA 92612
<br />485C US Route 1 South, Suite 105
<br />Iselin, NJ 08830
<br />www.saaia.com
<br />T 310.553.3252
<br />T 213.929.1400
<br />T 949.724.8958
<br />San Francisco, CA 94105
<br />T 415.390.6793
<br />T 848.200.1200
<br />New York, NY 10017
<br />T 917.512.6688
<br />575 Market St., Suite 502
<br />711 3rd Ave., 6th Floor
<br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL
<br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE,
<br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES.
<br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED
<br />12/18/23
<br />KL/SD/AW
<br />MP
<br />634772
<br />COUNTY OF ORANGE
<br />PROBATION TRAINING & VOLUNTEER SERVICES
<br />AND YOUTH REPORT CENTER
<br />1700 E ST ANDREW PL
<br />SANTA ANA, CA 92705
<br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A
<br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y
<br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN
<br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS
<br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT
<br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON
<br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS
<br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS
<br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR
<br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT
<br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES.
<br />02/22/2024 ISSUE FOR PLAN CHECK / BID
<br />02/26/2024 PLANNING COMMENTS A
<br />04/03/2024 TENANT COMMENTS / FIELD REVISIONS B
<br />AND PLAN CHECK COMMENTS 01
<br />1ST & 2ND FLOOR
<br />WALL TYPE
<br />CONSTRUCTION LEGEND
<br />NOTE:
<br />CONTRACTOR TO IDENTIFY IN BID AND INCLUDE IN PRICING ALL ITEMS LIKELY TO BE REQUIRED BY TITLE 24, CHAPTER 6 PART
<br />141.0 AND 141.1 BASED ON SCOPE OF WORK SHOWN IN PLAN. THIS SHALL INCLUDE (AS APPLICABLE) BUT NOT LIMITED TO:
<br />DESEGREGATION OF ELECTRICAL PANELS, CONTROLLED RECEPTACLES, DAYLIGHTING CONTROLS, OCCUPANCY SENSORS,
<br />MULTI-LEVEL SWITCHING AND/OR DIMMING, DEMAND RESPONSE AND HVAC EFFICIENCY MEASURES.
<br />CONSTRUCTION KEYNOTES
<br />2.1 INFILL EXISTING WALL/DOOR OPENING. MATCH EXISTING STUD WIDTH, TAPE (FIRE TAPE, 1-HR RATED
<br />CONSTRUCTION IF REQUIRED) SAND, SMOOTH AND PREP FOR NEW FINISHES.
<br />1/4" DIAMETER COLD COPPER WATER LINE FOR COFFEE MAKER WITH SHUT OFF VALVE.
<br />1/4" DIAMETER COLD COPPER WATER LINE FOR ICE MAKER WITH SHUT OFF VALVE.
<br />3/4" THICK FIRE TREATED PLYWOOD BACKBOARD FOR TENANT'S TELEPHONE EQUIPMENT. REFER TO POWER
<br />PLANS FOR EXACT SIZE AND LOCATIONS.
<br />2.2
<br />2.3
<br />2.4
<br />PROVIDE BLOCKING FOR TENANT'S WALL MOUNTED TELEVISION. SEE DETAIL 10/A-30.5.2.5
<br />NOTE: ALL NEW DOORS ARE TO BE 3'-0" WIDE MIN. UNLESS OTHERWISE NOTED.
<br />NOTE: ALL NEW DOOR PULL HARDWARE TO BE ACCESSIBLE, APPROVED "LEVER" TYPE.
<br />R
<br />AREA NOT IN CONTRACT (N.I.C.).
<br />EXISTING CONSTRUCTION TO REMAIN.
<br />EXISTING SINGLE DOOR, DOOR FRAME AND DOOR HARDWARE IS TO REMAIN AT LOCATION
<br />SHOWN.
<br />NEW CONSTRUCTION, TYPICAL PARTITION UNLESS OTHERWISE NOTED.
<br />PARTITION TYPE SYMBOL.
<br />SEE PARTITION TYPES LEGEND
<br />EXISTING DOOR, DOOR FRAME AND HARDWARE IS TO BE RE-USED AT NEW LOCATION.
<br />NEW SINGLE DOOR, DOOR FRAME AND HARDWARE.
<br />NEW DOUBLE DOOR, DOOR FRAME AND HARDWARE.
<br />ROOM KEY SYMBOL
<br />ROOM NAME
<br />ROOM NUMBER
<br />-
<br />NAME
<br />100
<br />1/4" COPPER WATER LINE
<br />SINGLE COMPARTMENT SINK. REFER TO ITEM #2 ON THE CONSTRUCTION SPECIFICATIONS ON
<br />SHEET A-0.3.
<br />DOUBLE COMPARTMENT SINK. REFER TO ITEM #4 ON THE CONSTRUCTION SPECIFICATIONS ON
<br />SHEET A-0.3.
<br />BUILDING STANDARD, SEMI - RECESSED FIRE EXTINGUISHER CABINET.
<br />REFER TO DETAILS #13 AND #14/A-30.0.
<br />SFEC
<br />TYPE DETAIL DESCRIPTION
<br />WALL TYPE
<br />A2 EXTEND TO FACE OF FINISHED CEILING. PROVIDE INSULATION IN THE STUD CAVITY.
<br />PROVIDE INSULATION OVER THE TOP OF THE WALL.
<br />C1 FULL HEIGHT WALL. PROVIDE INSULATION IN THE STUD CAVITY.
<br />H LOW HEIGHT WALL, NO INSULATION.
<br />1A1 FULL HEIGHT ONE HOUR RATED WALL, PROVIDE INSULATION IN THE STUD CAVITY.
<br />C3 FULL HEIGHT WALL, (2) LAYERS STAGGERED GYP. BD.. PROVIDE INSULATION IN THE
<br />STUD CAVITY.
<br />2/A-30.0
<br />F2 FRAMED WINDOW WALL. NO INSULATION.3/A-30.4
<br />4/A-30.0
<br />5/A-30.0
<br />5/A-30.0
<br />1/A-30.0
<br />EXISTING DOUBLE DOOR, DOOR FRAME AND DOOR HARDWARE IS TO REMAIN AT LOCATION
<br />SHOWN.
<br />NEW 6' LOW WALL WITH SHORT DOOR.
<br />HATCH INDICATES FULL HEIGHT INSULATED WALLS.
<br />NEW FRAMED SIDELIGHT/GLASS PARTITION.
<br />DOOR SYMBOL
<br />DOOR CODE SEE SHEET A-10.0
<br />FOR DOOR SPEC'S AND HARDWARE100
<br />NEW FIRE RATED PARTITION TO MATCH EXISTING.
<br />ALTERNATE CONSTRUCTION KEYNOTES
<br />A PROVIDE SEPARATE PRICING FOR RECONFIGURATION OF SHOWER/LOCKER/RESTROOMS. PRICING SHOULD
<br />INCLUDE DEMOLITION, NEW WALL+PLUMBING LAYOUT, FINISHES, PLUMBING FIXTURE, ACCESSORIES, NEW
<br />CEILING, LIGHT FIXTURES AND LOCKERS.
<br />B PROVIDE SEPARATE PRICING FOR NEW MOVABLE PARTITIONS. PRICING SHOULD INCLUDE REWORK OF CEILING
<br />ABOVE, NEW STRUCTURAL BEAM+COLUMN, ANY PERMIT EXTENSION/COO, AND NEW DRYWALL SOFFIT.
<br />C2 PARTITION TO 24" ABOVE CEILING IN DOUBLE VOLUME SPACE, BRACING TO STRUCTURE
<br />ABOVE. PROVIDE INSULATION IN THE STUD CAVITY AND ON CEILING.12/A-30.0
<br />PROVIDE DRYWALL AT EXPOSED STUD WALLS TO MATCH WALL TYPE C1, PREP WALL FOR NEW PAINT. PREP
<br />EXISTING WALL AT ROOM #239 FOR NEW APPROVED FINISH. REFER TO FINISH PLAN.2.6
<br />NEW GUARD RAIL.
<br />PROVIDE PERSONAL STORAGE LOCKERS, REFER TO PLANS FOR QUANTITY.
<br />SPEC: SOUTHWEST SOLUTIONS GROUP, FREE STYLE PERSONAL METAL STORAGE LOCKER
<br />18" W X 24" D X 72" H, HASP FOR PADLOCK, DOUBLE DOOR, 18" HIGH EXTERNAL ACCESS DRAWER AND 18" HIGH
<br />BENCH DRAWER WITH BUTCHER BLOCK SEAT, LIGHT WOOD FINISH. ACCESSORIES SHOULD INCLUDE 6" INTERNAL
<br />DRAWER, FILE DIVIDER KIT, 12" MODULAR SHELF, FULL-WIDTH SHELVES, AND HOOK BRACKET HANGER. ALL
<br />OTHER ACCESSORIES TO BE CONFIRMED WITH YRC. PROVIDE VERTICAL ANGLE FILLERS AND WALL ANGLE, SLIP
<br />JOINT AS REQUIRED. PROVIDE SHOP DRAWINGS TO CONFIRM EXACT DIMENSION PRIOR TO FRAMING. CONFIRM
<br />HEIGHT, WIDTH AND DEPTH WITH LOCK MANUFACTURER. ANCHOR LOCKERS TO FLOOR AND WALL AS REQUIRED.
<br />STANDARD PAINT FINISH, FROST FR 6 OR APPROVED EQUAL.
<br />2.7
<br />PROVIDE FULL LENGTH MIRROR.
<br />SPEC: BOBRICK B-165 SERIES CHANNEL-FRAME, B-165 2460: 24″ W X 60″ H, PROVIDE BACK IN WALL IF REQUIRED,
<br />HUNG AT 18" AFF TO BOTTOM OF GLASS.
<br />2.8
<br />E WALL FURRING TO EXTEND 6" ABOVE FINISHED CEILING. NO INSULATION.7/A-30.0
<br />PROVIDE CHAIN LINK FENCE WITH POSTS AT 4'-0" O.C. MAX. FENCE HEIGHT TO EXTEND TO CEILING ABOVE, SEE
<br />REFLECTED CEILING PLAN FOR CEILING HEIGHT. PROVIDE 3'-0" WIDE SLIDING GATE. MANUF: TBD. SEE DETAIL
<br />17/A-30.1.
<br />2.9
<br />C PROVIDE SEPARATE PRICING FOR NEW GARAVENTA GENESIS ENCLOSURE VERTICAL PLATFORM LIFT, 90-DEGREE
<br />ENTRY/EXIT CONFIGURATION, LARGE PLATFORM SIZE, HYDRAULIC DRIVE SYSTEM, AND FULL HEIGHT ENCLOSURE
<br />AT TOP LANDING. PROVIDE ILLUMINATED AND TACTILE PUSH BUTTON CONTROL PACKAGE. PROVIDE 36" X 84"
<br />SWING DOORS. FRAME COLOR: BLACK, GLAZING: CLEAR. PROVIDE 3" PIT AS REQUIRED BY MANUFACTURER FOR
<br />FLUSH ACCESSIBLE ENTRY AT BOTTOM LANDING. PERMIT BY OTHERS. CONTRACTOR TO PROVIDE ALLOWANCE
<br />FOR CONCRETE FLOAT AS REQUIRED LEADING INTO LIFT FROM HALLWAY ON FIRST FLOOR. CONTRACTOR TO
<br />COORDINATE WITH DESIGN BUILD CONTRACTOR FOR DETAILS. PLATFORM LIFT TO BE ON A SEPARATE PERMIT.
<br />D PROVIDE SEPARATE PRICING FOR CATWALK SYSTEM, MANUF: TBD. 42" MIN. HIGH GUARDRAIL, WITH
<br />HORIZONTAL INTERMEDIATE RAIL AT 4" O.C. TYP. STEEL GRATING AND SOLID FLOOR FINISH WHERE INDICATED ON
<br />PLANS. MATTE POWDER COATED FINISH, COLOR: BLACK. MEZZANINE CATWALK TO BE ON A SEPARATE PERMIT.
<br />E PROVIDE SEPARATE PRICING FOR (2) DESIGN-BUILD EXTERIOR CANOPIES OVER YRC & TVS MAIN ENTRANCE.
<br />MANUFACTURER, STYLE, AND FINISH: TBD. PERMIT BY OTHERS. CONTRACTOR TO COORDINATE WITH TENANT
<br />AND BUILDING OWNER FOR EXACT SPECIFICATION AND APPROVAL. EXTERIOR CANOPIES TO BE ON A SEPARATE
<br />PERMIT.
<br />DEMISING WALLS, CORRIDOR WALLS AND CLASSROOMS SHOULD BE DECK HEIGHT WITH INSULATION IN STUD
<br />CAVITY. VERIFY IN FIELD AND PONY UP AS REQUIRED. REWORK EXISTING CEILING SYSTEM AS REQUIRED,
<br />PROVIDE WALL ANGLES.
<br />2.10
<br />ALL PRIVATE OFFICE WALL TO BE CEILING HEIGHT WITH INSULATION IN STUD CAVITY WITH INSULATION
<br />BLANKETS EXTEND 4' ON EITHER SIDE OF WALL, SEE WALL TYPE A2. VERIFY EXISTING WALLS AND REWORK AS
<br />REQUIRED.
<br />2.11
<br />NOT USED2.12
<br />PROVIDE 1 - HR RATED CONDITION AT COMMON CORRIDOR 200. VERIFY IN FIELD AND PONY UP AND REWORK
<br />EXISTING WALLS AND CEILING AS REQUIRED. PROVIDE WALL ANGLES.2.13
<br />E1 WALL FURRING/SILL CONDITION BELOW EXTERIOR WINDOWS.6/A-30.0
<br />1B1 3/A-30.0
<br />INSULATED (NON-RATED) TUNNEL CONSTRUCTION. PROVIDE INSULATION IN STUD
<br />CAVITY AND ON CEILING.8/A-30.01C1
<br />A1 1/A-30.0 EXTEND TO FACE OF FINISHED CEILING. PROVIDE INSULATION IN THE STUD CAVITY.
<br />ONE HOUR RATED TUNNEL WALL.
<br />ONE HOUR RATED TUNNEL WALL.
<br />PROVIDE PUSH/PULL HARDWARE AT RESTROOM #189, 188, 231 AND 232. REPLACE EXISTING WHERE OCCURS,
<br />PATCH AFFECTED AREA AS REQUIRED.
<br />2.14
<br />PROVIDE NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER INSIDE. REFER TO A-0.3
<br />FOR SPECIFICATIONS. MODIFY EXISTING OPENING WHERE REQUIRED PER NEW SPECIFICATION.
<br />MAXIMUM PROTRUSION IS 4" MAX PER CBC 11B-307.1.
<br />2.15
<br />CONTRACTOR TO VERIFY EXISTING DOOR, FRAMES AND HARDWARE CONDITION. REPLACE EXISTING
<br />HARDWARE TO MATCH BUILDING STANDARD PANIC BAR. REWORK EXISTING HARDWARE TO RECEIVE
<br />TENANT'S KEYCARD SYSTEM. PREP DOOR AND FRAMES TO RECEIVE NEW PAINT. PAINT P-1 SEMI-GLOSS.
<br />2.16
<br />VERIFY EXISTING TO REMAIN DOORS IN SCOPE AREA INCLUDING CORRIDOR AND STAIR DOORS IN FIELD.
<br />PROVIDE ALLOWANCE TO TOUCH UP/ REPAIR AS REQUIRED. PAINT EXISTING PAINTED DOORS AS REQUIRED.
<br />REPLACE/REPAIR EXISTING HARDWARE AS REQUIRED. REFER TO POWER PLAN FOR CARD READER LOCATIONS
<br />AND PREP DOORS AS REQUIRED TO RECEIVE TENANT'S CARD READER SYSTEM WHERE OCCURS.
<br />2.17
<br />NEW 42" MIN. HIGH GUARDRAIL WITH HORIZONTAL INTERMEDIATE RAILS AT 4" O.C. TYP. MATCH CATWALK
<br />GUARDRAILING. MATTE POWDER COATED FINISH, COLOR: BLACK.2.18
<br />F PROVIDE ALTERNATE PRICING FOR BUILT IN CUSTOM DISPLAY CASE WITH LOW IRON GLASS DOORS WITH GLASS
<br />SHELVES. REFER TO ELEVATION AND SECTION DETAIL FOR ADDITIONAL INFORMATION. PRICING SHOULD
<br />INCLUDE RECESSED LIGHTING AND WING WALLS.
<br />G NOT USED.
<br />11/A-30.4J2 FRAMED WINDOW WALL.
<br />H PROVIDE ALTERNATE PRICING FOR B1 WALL TYPE (6" ABOVE CEILING GRID WITH INSULATION IN STUD CAVITY) AT
<br />ALL OFFICES IN LIEU OF A2 WALL TYPE (CEILING HEIGHT WITH INSULATION IN STUD CAVITY AND BLANKET ABOVE
<br />CEILING EXTEND 48" ON BOTH SIDES).
<br />I PROVIDE ALTERNATE PRICING FOR SOUND BOOTS AT ALL YRC PRIVATES OFFICES.
<br />J PROVIDE ALTERNATE DEDUCT FOR REFRIGERATOR, FREEZER, AND MICROWAVE TO BE PROVIDED BY TENANT.
<br />B
<br />MODIFY EXISTING WALLS TO MATCH C1 WALL TYPE FULL HEIGHT INSULATION.2.19
<br />MODIFY EXISTING WALLS TO MATCH C3 WALL TYPE FULL HEIGHT INSULATION.2.20
<br />B
<br />K NOT USED.
<br />B1 EXTEND 6" ABOVE THE FINISHED CEILING. PROVIDE INSULATION IN THE STUD CAVITY.19/A-30.0
<br />B
<br />B
<br />L PROVIDE ALTERNATE PRICING FOR BUILT IN PLASTIC LAMINATE 24" D X 72" H X 18" W LOCKERS IN ACADEMY
<br />STORAGE #184.
<br />B
<br />LOW WALL WITH PLASTIC LAMINATE CAP ABOVE. PL-1.2.21
<br />PROVIDE DRYWALL LAMINATED ON BOTH SIDES OF EXISTING CONCRETE SHEAR WALL. PROVIDE CLEAR ANODIZED
<br />FINISH J-MOLDING TO CAP DRYWALL, MITERED CORNERS WHERE OCCURS. PASS THROUGH OPENING SHOULD BE
<br />MINIMUM 32" CLEAR WIDTH X 8' H. INSIDE OPEN PASS THROUGH FINISH TO BE EXPOSED CONCRETE OR PAINT TO
<br />MATCH ADJACENT WALL. VERIFY CONDITION IN FIELD AND COORDINATE WITH ARCHITECT AS NEEDED.
<br />REFER TO STRUCTURAL PLANS FOR DETAILS.
<br />2.22
<br />B
<br />WHERE LOCKERS ARE PROVIDED SHALL MEET CBC 11B-225.2.
<br />A.MIN 5% OF LOCKERS SHALL BE ACCESSIBLE.
<br />B.STORAGE ELEMENTS SHALL BE WITHIN REACH RANGE. CBC 11B-811.
<br />C.OPERABLE PART SHALL COMPLY WITH CBC 11B-309.
<br />2.23
<br />AT ACADEMY STORAGE, PROVIDE 6' HIGH DOUBLE TIER LOCKERS.
<br />SPEC: SALSBURY 15" WIDE PREMIER WOOD LOCKER - DOUBLE TIER - 1 WIDE - 6 FEET HIGH WITH BASE - 24" DEEP -
<br />COLOR: WINTER FOG, PROVIDE (1) ADJUSTABLE SHELF $44,294, MODEL # 15-42164, SIZE: 15" W X 76" H X 24" D,
<br />PROVIDE MATCHING SIDE PANELS, FLAT TOP IN-LINE FILLER AND FRONT FILLERS AND CORNER FILLERS AS REQUIRED
<br />WHERE OCCURS. CONFIRM WITH TENANT IF HASP IS REQUIRED. ANCHOR LOCKERS TO FLOOR AND WALL AS
<br />REQUIRED.
<br />2.24
<br />AT ACCESSIBLE CHANGING ROOM, PROVIDE 48" WIDE X 20" DEEP X 18" H BENCH.
<br />SPEC: SALSBURY, WOOD ADA LOCKER BENCH 77782-ADA, LIGHT FINISH OR APPROVED EQUAL.2.25
<br />B
<br />M PROVIDE ALTERNATE DEDUCT PRICING FOR ALL TELE/DATA OUTLETS THROUGHOUT SCOPE AREA TO BE 3/4" DIA
<br />CONDUIT IN LIEU OF 1" DIA .
<br />INFILL EXISTING OPENING IN EXTERIOR CONC. TILT UP WALL. SEE DETAIL 13/A-30.1.2.26
<br />1/4" DIAMETER COPPER WATER LINE FOR TENANT'S COFFEE VENDING MACHINE WITH SHUT OFF VALVE.
<br />CONTRACTOR TO PROVIDE ALTERNATE PRICING FOR WATER FILTER PER MANUFACTURER SPECIFICATIONS,
<br />COORDINATE WITH TENANT AND VENDOR FOR ADDITIONAL INFORMATION.
<br />2.27
<br />CONTRACTOR TO FIELD VERIFY EXTERIOR CONDITION, PROVIDE ALLOWANCE FOR CONCRETE PATH REWORK AS
<br />REQUIRED AT NEW ACCESSIBLE DOOR LANDING.
<br />2.28
<br />B
<br />NELSON
<br />ALGAZE
<br />No. C-21090
<br />REN. 03/31/2025
<br />L
<br />CENSE ARC
<br />EC
<br />SAE O CAL ORNA
<br />1700 E St Andrew Pl - 101118387,
<br />20182190, 30146952 & 40138878
<br />6/5/2024
|