Laserfiche WebLink
CONSTRUCTION PLAN <br />LEGEND & KEYNOTES <br />A-2.0 <br />AS NOTED <br />PROJECT: <br />DATE: <br />DRAWN: <br />SCALE: <br />PROJECT NO: <br />REVIEWED: <br />SHEET NO: <br />SHEET TITLE: <br />STAMP AND SIGNATURE: <br />CONSULTANTS: <br />DATE DESCRIPTION DELTA <br />DRAWINGS ISSUE <br />02/15/2024 ISSUE FOR PLANNING APPROVAL <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />515 South Flower St., Suite 1200 <br />Los Angeles, CA 90071 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />www.saaia.com <br />T 310.553.3252 <br />T 213.929.1400 <br />T 949.724.8958 <br />San Francisco, CA 94105 <br />T 415.390.6793 <br />T 848.200.1200 <br />New York, NY 10017 <br />T 917.512.6688 <br />575 Market St., Suite 502 <br />711 3rd Ave., 6th Floor <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL <br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, <br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />12/18/23 <br />KL/SD/AW <br />MP <br />634772 <br />COUNTY OF ORANGE <br />PROBATION TRAINING & VOLUNTEER SERVICES <br />AND YOUTH REPORT CENTER <br />1700 E ST ANDREW PL <br />SANTA ANA, CA 92705 <br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A <br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN <br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS <br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT <br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON <br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS <br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR <br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT <br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />02/22/2024 ISSUE FOR PLAN CHECK / BID <br />02/26/2024 PLANNING COMMENTS A <br />04/03/2024 TENANT COMMENTS / FIELD REVISIONS B <br />AND PLAN CHECK COMMENTS 01 <br />1ST & 2ND FLOOR <br />WALL TYPE <br />CONSTRUCTION LEGEND <br />NOTE: <br />CONTRACTOR TO IDENTIFY IN BID AND INCLUDE IN PRICING ALL ITEMS LIKELY TO BE REQUIRED BY TITLE 24, CHAPTER 6 PART <br />141.0 AND 141.1 BASED ON SCOPE OF WORK SHOWN IN PLAN. THIS SHALL INCLUDE (AS APPLICABLE) BUT NOT LIMITED TO: <br />DESEGREGATION OF ELECTRICAL PANELS, CONTROLLED RECEPTACLES, DAYLIGHTING CONTROLS, OCCUPANCY SENSORS, <br />MULTI-LEVEL SWITCHING AND/OR DIMMING, DEMAND RESPONSE AND HVAC EFFICIENCY MEASURES. <br />CONSTRUCTION KEYNOTES <br />2.1 INFILL EXISTING WALL/DOOR OPENING. MATCH EXISTING STUD WIDTH, TAPE (FIRE TAPE, 1-HR RATED <br />CONSTRUCTION IF REQUIRED) SAND, SMOOTH AND PREP FOR NEW FINISHES. <br />1/4" DIAMETER COLD COPPER WATER LINE FOR COFFEE MAKER WITH SHUT OFF VALVE. <br />1/4" DIAMETER COLD COPPER WATER LINE FOR ICE MAKER WITH SHUT OFF VALVE. <br />3/4" THICK FIRE TREATED PLYWOOD BACKBOARD FOR TENANT'S TELEPHONE EQUIPMENT. REFER TO POWER <br />PLANS FOR EXACT SIZE AND LOCATIONS. <br />2.2 <br />2.3 <br />2.4 <br />PROVIDE BLOCKING FOR TENANT'S WALL MOUNTED TELEVISION. SEE DETAIL 10/A-30.5.2.5 <br />NOTE: ALL NEW DOORS ARE TO BE 3'-0" WIDE MIN. UNLESS OTHERWISE NOTED. <br />NOTE: ALL NEW DOOR PULL HARDWARE TO BE ACCESSIBLE, APPROVED "LEVER" TYPE. <br />R <br />AREA NOT IN CONTRACT (N.I.C.). <br />EXISTING CONSTRUCTION TO REMAIN. <br />EXISTING SINGLE DOOR, DOOR FRAME AND DOOR HARDWARE IS TO REMAIN AT LOCATION <br />SHOWN. <br />NEW CONSTRUCTION, TYPICAL PARTITION UNLESS OTHERWISE NOTED. <br />PARTITION TYPE SYMBOL. <br />SEE PARTITION TYPES LEGEND <br />EXISTING DOOR, DOOR FRAME AND HARDWARE IS TO BE RE-USED AT NEW LOCATION. <br />NEW SINGLE DOOR, DOOR FRAME AND HARDWARE. <br />NEW DOUBLE DOOR, DOOR FRAME AND HARDWARE. <br />ROOM KEY SYMBOL <br />ROOM NAME <br />ROOM NUMBER <br />- <br />NAME <br />100 <br />1/4" COPPER WATER LINE <br />SINGLE COMPARTMENT SINK. REFER TO ITEM #2 ON THE CONSTRUCTION SPECIFICATIONS ON <br />SHEET A-0.3. <br />DOUBLE COMPARTMENT SINK. REFER TO ITEM #4 ON THE CONSTRUCTION SPECIFICATIONS ON <br />SHEET A-0.3. <br />BUILDING STANDARD, SEMI - RECESSED FIRE EXTINGUISHER CABINET. <br />REFER TO DETAILS #13 AND #14/A-30.0. <br />SFEC <br />TYPE DETAIL DESCRIPTION <br />WALL TYPE <br />A2 EXTEND TO FACE OF FINISHED CEILING. PROVIDE INSULATION IN THE STUD CAVITY. <br />PROVIDE INSULATION OVER THE TOP OF THE WALL. <br />C1 FULL HEIGHT WALL. PROVIDE INSULATION IN THE STUD CAVITY. <br />H LOW HEIGHT WALL, NO INSULATION. <br />1A1 FULL HEIGHT ONE HOUR RATED WALL, PROVIDE INSULATION IN THE STUD CAVITY. <br />C3 FULL HEIGHT WALL, (2) LAYERS STAGGERED GYP. BD.. PROVIDE INSULATION IN THE <br />STUD CAVITY. <br />2/A-30.0 <br />F2 FRAMED WINDOW WALL. NO INSULATION.3/A-30.4 <br />4/A-30.0 <br />5/A-30.0 <br />5/A-30.0 <br />1/A-30.0 <br />EXISTING DOUBLE DOOR, DOOR FRAME AND DOOR HARDWARE IS TO REMAIN AT LOCATION <br />SHOWN. <br />NEW 6' LOW WALL WITH SHORT DOOR. <br />HATCH INDICATES FULL HEIGHT INSULATED WALLS. <br />NEW FRAMED SIDELIGHT/GLASS PARTITION. <br />DOOR SYMBOL <br />DOOR CODE SEE SHEET A-10.0 <br />FOR DOOR SPEC'S AND HARDWARE100 <br />NEW FIRE RATED PARTITION TO MATCH EXISTING. <br />ALTERNATE CONSTRUCTION KEYNOTES <br />A PROVIDE SEPARATE PRICING FOR RECONFIGURATION OF SHOWER/LOCKER/RESTROOMS. PRICING SHOULD <br />INCLUDE DEMOLITION, NEW WALL+PLUMBING LAYOUT, FINISHES, PLUMBING FIXTURE, ACCESSORIES, NEW <br />CEILING, LIGHT FIXTURES AND LOCKERS. <br />B PROVIDE SEPARATE PRICING FOR NEW MOVABLE PARTITIONS. PRICING SHOULD INCLUDE REWORK OF CEILING <br />ABOVE, NEW STRUCTURAL BEAM+COLUMN, ANY PERMIT EXTENSION/COO, AND NEW DRYWALL SOFFIT. <br />C2 PARTITION TO 24" ABOVE CEILING IN DOUBLE VOLUME SPACE, BRACING TO STRUCTURE <br />ABOVE. PROVIDE INSULATION IN THE STUD CAVITY AND ON CEILING.12/A-30.0 <br />PROVIDE DRYWALL AT EXPOSED STUD WALLS TO MATCH WALL TYPE C1, PREP WALL FOR NEW PAINT. PREP <br />EXISTING WALL AT ROOM #239 FOR NEW APPROVED FINISH. REFER TO FINISH PLAN.2.6 <br />NEW GUARD RAIL. <br />PROVIDE PERSONAL STORAGE LOCKERS, REFER TO PLANS FOR QUANTITY. <br />SPEC: SOUTHWEST SOLUTIONS GROUP, FREE STYLE PERSONAL METAL STORAGE LOCKER <br />18" W X 24" D X 72" H, HASP FOR PADLOCK, DOUBLE DOOR, 18" HIGH EXTERNAL ACCESS DRAWER AND 18" HIGH <br />BENCH DRAWER WITH BUTCHER BLOCK SEAT, LIGHT WOOD FINISH. ACCESSORIES SHOULD INCLUDE 6" INTERNAL <br />DRAWER, FILE DIVIDER KIT, 12" MODULAR SHELF, FULL-WIDTH SHELVES, AND HOOK BRACKET HANGER. ALL <br />OTHER ACCESSORIES TO BE CONFIRMED WITH YRC. PROVIDE VERTICAL ANGLE FILLERS AND WALL ANGLE, SLIP <br />JOINT AS REQUIRED. PROVIDE SHOP DRAWINGS TO CONFIRM EXACT DIMENSION PRIOR TO FRAMING. CONFIRM <br />HEIGHT, WIDTH AND DEPTH WITH LOCK MANUFACTURER. ANCHOR LOCKERS TO FLOOR AND WALL AS REQUIRED. <br />STANDARD PAINT FINISH, FROST FR 6 OR APPROVED EQUAL. <br />2.7 <br />PROVIDE FULL LENGTH MIRROR. <br />SPEC: BOBRICK B-165 SERIES CHANNEL-FRAME, B-165 2460: 24″ W X 60″ H, PROVIDE BACK IN WALL IF REQUIRED, <br />HUNG AT 18" AFF TO BOTTOM OF GLASS. <br />2.8 <br />E WALL FURRING TO EXTEND 6" ABOVE FINISHED CEILING. NO INSULATION.7/A-30.0 <br />PROVIDE CHAIN LINK FENCE WITH POSTS AT 4'-0" O.C. MAX. FENCE HEIGHT TO EXTEND TO CEILING ABOVE, SEE <br />REFLECTED CEILING PLAN FOR CEILING HEIGHT. PROVIDE 3'-0" WIDE SLIDING GATE. MANUF: TBD. SEE DETAIL <br />17/A-30.1. <br />2.9 <br />C PROVIDE SEPARATE PRICING FOR NEW GARAVENTA GENESIS ENCLOSURE VERTICAL PLATFORM LIFT, 90-DEGREE <br />ENTRY/EXIT CONFIGURATION, LARGE PLATFORM SIZE, HYDRAULIC DRIVE SYSTEM, AND FULL HEIGHT ENCLOSURE <br />AT TOP LANDING. PROVIDE ILLUMINATED AND TACTILE PUSH BUTTON CONTROL PACKAGE. PROVIDE 36" X 84" <br />SWING DOORS. FRAME COLOR: BLACK, GLAZING: CLEAR. PROVIDE 3" PIT AS REQUIRED BY MANUFACTURER FOR <br />FLUSH ACCESSIBLE ENTRY AT BOTTOM LANDING. PERMIT BY OTHERS. CONTRACTOR TO PROVIDE ALLOWANCE <br />FOR CONCRETE FLOAT AS REQUIRED LEADING INTO LIFT FROM HALLWAY ON FIRST FLOOR. CONTRACTOR TO <br />COORDINATE WITH DESIGN BUILD CONTRACTOR FOR DETAILS. PLATFORM LIFT TO BE ON A SEPARATE PERMIT. <br />D PROVIDE SEPARATE PRICING FOR CATWALK SYSTEM, MANUF: TBD. 42" MIN. HIGH GUARDRAIL, WITH <br />HORIZONTAL INTERMEDIATE RAIL AT 4" O.C. TYP. STEEL GRATING AND SOLID FLOOR FINISH WHERE INDICATED ON <br />PLANS. MATTE POWDER COATED FINISH, COLOR: BLACK. MEZZANINE CATWALK TO BE ON A SEPARATE PERMIT. <br />E PROVIDE SEPARATE PRICING FOR (2) DESIGN-BUILD EXTERIOR CANOPIES OVER YRC & TVS MAIN ENTRANCE. <br />MANUFACTURER, STYLE, AND FINISH: TBD. PERMIT BY OTHERS. CONTRACTOR TO COORDINATE WITH TENANT <br />AND BUILDING OWNER FOR EXACT SPECIFICATION AND APPROVAL. EXTERIOR CANOPIES TO BE ON A SEPARATE <br />PERMIT. <br />DEMISING WALLS, CORRIDOR WALLS AND CLASSROOMS SHOULD BE DECK HEIGHT WITH INSULATION IN STUD <br />CAVITY. VERIFY IN FIELD AND PONY UP AS REQUIRED. REWORK EXISTING CEILING SYSTEM AS REQUIRED, <br />PROVIDE WALL ANGLES. <br />2.10 <br />ALL PRIVATE OFFICE WALL TO BE CEILING HEIGHT WITH INSULATION IN STUD CAVITY WITH INSULATION <br />BLANKETS EXTEND 4' ON EITHER SIDE OF WALL, SEE WALL TYPE A2. VERIFY EXISTING WALLS AND REWORK AS <br />REQUIRED. <br />2.11 <br />NOT USED2.12 <br />PROVIDE 1 - HR RATED CONDITION AT COMMON CORRIDOR 200. VERIFY IN FIELD AND PONY UP AND REWORK <br />EXISTING WALLS AND CEILING AS REQUIRED. PROVIDE WALL ANGLES.2.13 <br />E1 WALL FURRING/SILL CONDITION BELOW EXTERIOR WINDOWS.6/A-30.0 <br />1B1 3/A-30.0 <br />INSULATED (NON-RATED) TUNNEL CONSTRUCTION. PROVIDE INSULATION IN STUD <br />CAVITY AND ON CEILING.8/A-30.01C1 <br />A1 1/A-30.0 EXTEND TO FACE OF FINISHED CEILING. PROVIDE INSULATION IN THE STUD CAVITY. <br />ONE HOUR RATED TUNNEL WALL. <br />ONE HOUR RATED TUNNEL WALL. <br />PROVIDE PUSH/PULL HARDWARE AT RESTROOM #189, 188, 231 AND 232. REPLACE EXISTING WHERE OCCURS, <br />PATCH AFFECTED AREA AS REQUIRED. <br />2.14 <br />PROVIDE NEW SEMI-RECESSED FIRE EXTINGUISHER CABINET AND FIRE EXTINGUISHER INSIDE. REFER TO A-0.3 <br />FOR SPECIFICATIONS. MODIFY EXISTING OPENING WHERE REQUIRED PER NEW SPECIFICATION. <br />MAXIMUM PROTRUSION IS 4" MAX PER CBC 11B-307.1. <br />2.15 <br />CONTRACTOR TO VERIFY EXISTING DOOR, FRAMES AND HARDWARE CONDITION. REPLACE EXISTING <br />HARDWARE TO MATCH BUILDING STANDARD PANIC BAR. REWORK EXISTING HARDWARE TO RECEIVE <br />TENANT'S KEYCARD SYSTEM. PREP DOOR AND FRAMES TO RECEIVE NEW PAINT. PAINT P-1 SEMI-GLOSS. <br />2.16 <br />VERIFY EXISTING TO REMAIN DOORS IN SCOPE AREA INCLUDING CORRIDOR AND STAIR DOORS IN FIELD. <br />PROVIDE ALLOWANCE TO TOUCH UP/ REPAIR AS REQUIRED. PAINT EXISTING PAINTED DOORS AS REQUIRED. <br />REPLACE/REPAIR EXISTING HARDWARE AS REQUIRED. REFER TO POWER PLAN FOR CARD READER LOCATIONS <br />AND PREP DOORS AS REQUIRED TO RECEIVE TENANT'S CARD READER SYSTEM WHERE OCCURS. <br />2.17 <br />NEW 42" MIN. HIGH GUARDRAIL WITH HORIZONTAL INTERMEDIATE RAILS AT 4" O.C. TYP. MATCH CATWALK <br />GUARDRAILING. MATTE POWDER COATED FINISH, COLOR: BLACK.2.18 <br />F PROVIDE ALTERNATE PRICING FOR BUILT IN CUSTOM DISPLAY CASE WITH LOW IRON GLASS DOORS WITH GLASS <br />SHELVES. REFER TO ELEVATION AND SECTION DETAIL FOR ADDITIONAL INFORMATION. PRICING SHOULD <br />INCLUDE RECESSED LIGHTING AND WING WALLS. <br />G NOT USED. <br />11/A-30.4J2 FRAMED WINDOW WALL. <br />H PROVIDE ALTERNATE PRICING FOR B1 WALL TYPE (6" ABOVE CEILING GRID WITH INSULATION IN STUD CAVITY) AT <br />ALL OFFICES IN LIEU OF A2 WALL TYPE (CEILING HEIGHT WITH INSULATION IN STUD CAVITY AND BLANKET ABOVE <br />CEILING EXTEND 48" ON BOTH SIDES). <br />I PROVIDE ALTERNATE PRICING FOR SOUND BOOTS AT ALL YRC PRIVATES OFFICES. <br />J PROVIDE ALTERNATE DEDUCT FOR REFRIGERATOR, FREEZER, AND MICROWAVE TO BE PROVIDED BY TENANT. <br />B <br />MODIFY EXISTING WALLS TO MATCH C1 WALL TYPE FULL HEIGHT INSULATION.2.19 <br />MODIFY EXISTING WALLS TO MATCH C3 WALL TYPE FULL HEIGHT INSULATION.2.20 <br />B <br />K NOT USED. <br />B1 EXTEND 6" ABOVE THE FINISHED CEILING. PROVIDE INSULATION IN THE STUD CAVITY.19/A-30.0 <br />B <br />B <br />L PROVIDE ALTERNATE PRICING FOR BUILT IN PLASTIC LAMINATE 24" D X 72" H X 18" W LOCKERS IN ACADEMY <br />STORAGE #184. <br />B <br />LOW WALL WITH PLASTIC LAMINATE CAP ABOVE. PL-1.2.21 <br />PROVIDE DRYWALL LAMINATED ON BOTH SIDES OF EXISTING CONCRETE SHEAR WALL. PROVIDE CLEAR ANODIZED <br />FINISH J-MOLDING TO CAP DRYWALL, MITERED CORNERS WHERE OCCURS. PASS THROUGH OPENING SHOULD BE <br />MINIMUM 32" CLEAR WIDTH X 8' H. INSIDE OPEN PASS THROUGH FINISH TO BE EXPOSED CONCRETE OR PAINT TO <br />MATCH ADJACENT WALL. VERIFY CONDITION IN FIELD AND COORDINATE WITH ARCHITECT AS NEEDED. <br />REFER TO STRUCTURAL PLANS FOR DETAILS. <br />2.22 <br />B <br />WHERE LOCKERS ARE PROVIDED SHALL MEET CBC 11B-225.2. <br />A.MIN 5% OF LOCKERS SHALL BE ACCESSIBLE. <br />B.STORAGE ELEMENTS SHALL BE WITHIN REACH RANGE. CBC 11B-811. <br />C.OPERABLE PART SHALL COMPLY WITH CBC 11B-309. <br />2.23 <br />AT ACADEMY STORAGE, PROVIDE 6' HIGH DOUBLE TIER LOCKERS. <br />SPEC: SALSBURY 15" WIDE PREMIER WOOD LOCKER - DOUBLE TIER - 1 WIDE - 6 FEET HIGH WITH BASE - 24" DEEP - <br />COLOR: WINTER FOG, PROVIDE (1) ADJUSTABLE SHELF $44,294, MODEL # 15-42164, SIZE: 15" W X 76" H X 24" D, <br />PROVIDE MATCHING SIDE PANELS, FLAT TOP IN-LINE FILLER AND FRONT FILLERS AND CORNER FILLERS AS REQUIRED <br />WHERE OCCURS. CONFIRM WITH TENANT IF HASP IS REQUIRED. ANCHOR LOCKERS TO FLOOR AND WALL AS <br />REQUIRED. <br />2.24 <br />AT ACCESSIBLE CHANGING ROOM, PROVIDE 48" WIDE X 20" DEEP X 18" H BENCH. <br />SPEC: SALSBURY, WOOD ADA LOCKER BENCH 77782-ADA, LIGHT FINISH OR APPROVED EQUAL.2.25 <br />B <br />M PROVIDE ALTERNATE DEDUCT PRICING FOR ALL TELE/DATA OUTLETS THROUGHOUT SCOPE AREA TO BE 3/4" DIA <br />CONDUIT IN LIEU OF 1" DIA . <br />INFILL EXISTING OPENING IN EXTERIOR CONC. TILT UP WALL. SEE DETAIL 13/A-30.1.2.26 <br />1/4" DIAMETER COPPER WATER LINE FOR TENANT'S COFFEE VENDING MACHINE WITH SHUT OFF VALVE. <br />CONTRACTOR TO PROVIDE ALTERNATE PRICING FOR WATER FILTER PER MANUFACTURER SPECIFICATIONS, <br />COORDINATE WITH TENANT AND VENDOR FOR ADDITIONAL INFORMATION. <br />2.27 <br />CONTRACTOR TO FIELD VERIFY EXTERIOR CONDITION, PROVIDE ALLOWANCE FOR CONCRETE PATH REWORK AS <br />REQUIRED AT NEW ACCESSIBLE DOOR LANDING. <br />2.28 <br />B <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025 <br />L <br />CENSE ARC <br />EC <br />SAE O CAL ORNA <br />1700 E St Andrew Pl - 101118387, <br />20182190, 30146952 & 40138878 <br />6/5/2024