Laserfiche WebLink
A-3.0 <br />PROJECT: <br />DATE: <br />DRAWN: <br />SCALE: <br />PROJECT NO: <br />REVIEWED: <br />SHEET NO: <br />SHEET TITLE: <br />STAMP AND SIGNATURE: <br />CONSULTANTS: <br />DATE DESCRIPTION DELTA <br />DRAWINGS ISSUE <br />02/15/2024 ISSUE FOR PLANNING APPROVAL <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />515 South Flower St., Suite 1200 <br />Los Angeles, CA 90071 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />www.saaia.com <br />T 310.553.3252 <br />T 213.929.1400 <br />T 949.724.8958 <br />San Francisco, CA 94105 <br />T 415.390.6793 <br />T 848.200.1200 <br />New York, NY 10017 <br />T 917.512.6688 <br />575 Market St., Suite 502 <br />711 3rd Ave., 6th Floor <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL <br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, <br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />12/18/23 <br />KL/SD/AW <br />MP <br />634772 <br />COUNTY OF ORANGE <br />PROBATION TRAINING & VOLUNTEER SERVICES <br />AND YOUTH REPORT CENTER <br />1700 E ST ANDREW PL <br />SANTA ANA, CA 92705 <br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A <br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN <br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS <br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT <br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON <br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS <br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR <br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT <br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />02/22/2024 ISSUE FOR PLAN CHECK / BID <br />02/26/2024 PLANNING COMMENTS A <br />04/03/2024 TENANT COMMENTS / FIELD REVISIONS B <br />AND PLAN CHECK COMMENTS 01 <br />POWER VOICE DATA PLAN <br />LEGEND & KEYNOTES <br />AS NOTED <br />1ST & 2ND FLOOR <br />POWER/ VOICE/ DATA LEGEND <br />DESIGN CRITERIA NOTES <br />SWITCHES AND RECEPTACLES <br />1. ALL SWITCHES AND RECEPTACLES AT P-1 AND/OR WHITE WALLS SHALL BE WHITE SCREWLESS, U.O.N. GC TO CONFIRM <br />COLOR FINISH ON ALL SUCH COMPONENTS AT NON-WHITE WALLS WITH ARCHITECT BEFORE PURCHASE AND <br />INSTALLATION. <br />2. GC SHALL BE RESPONSIBLE FOR CONFIRMING RECEPTACLE TYPES FOR SPECIAL EQUIPMENT (SUCH AS COPY <br />MACHINES)WITH CLIENT AND ARCHITECT BEFORE PURCHASE AND INSTALLATION. <br />3. ALL VOICE AND DATA OUTLETS SHALL MATCH POWER OUTLETS AS ABOVE U.O.N. <br />4. ALL DIMMER SWITCHES SHALL MATCH POWER SWITCHES AS ABOVE U.O.N. <br />5. SWITCHES AND RECEPTACLES MAY BE LEVITON DECORA, LUTRON, OR COOPER, U.O.N. <br />6. SUBMIT SAMPLES OF SWITCHES AND PLATES FOR APPROVAL. <br />POWER/ VOICE/ DATA KEYNOTES <br />WALL MOUNTED DUPLEX ELECTRICAL OUTLET. SEE ENGINEER'S DRAWINGS FOR CONDUIT SIZE. <br />KEY CARD READER. PROVIDE (1) 3/4" CONDUIT AND A FLUSH MOUNTED SINGLE GANG BOX. CONDUIT IS TO STUB <br />OUT 6" ABOVE CEILING, STUB OUT ON CORRIDOR SIDE. AT HINGE SIDE OF DOOR PROVIDE A 3/4" CONDUIT AT <br />THE SECOND HINGE FROM THE BOTTOM TO 6" ABOVE THE CEILING, STUB OUT ON CORRIDOR SIDE. REFER TO <br />DETAIL 3/-. <br />TELE COMMUNICATIONS/DATA WALL OUTLET. PROVIDE EMPTY J-BOX OR PLASTER RING & 1" DIA. EMPTY EMT <br />CONDUIT STUBBED-UP @+/-6" ABOVE SUSP. CLG. W/ PROTECTIVE PLASTIC RING & PULL STRING/ TENANT'S <br />VENDOR TO PROVIDE COVER PLATES AND PLENUM RATED CABLES. VERIFY SIZE OF CONDUIT WITH <br />CABLING/PHONE VENDOR OR WHEN FEEDING MORE THAN (1) LOCATION. <br />WALL MOUNTED QUADRUPLEX ELECTRICAL OUTLET. SEE ENGINEER'S DRAWINGS FOR CONDUIT SIZE. <br />WALL MOUNTED DUPLEX ELECTRICAL OUTLET, SEPARATE CIRCUIT. SEE ENGINEER'S DRAWINGS FOR CONDUIT <br />SIZE. <br />FLUSH FLOOR MOUNTED FIRE RATED JUNCTION BOX, TELE/DATA AND QUAD OUTLET. VERIFY CONDUIT SIZE <br />FOR DATA/TELE REQUIREMENTS. COORDINATE LOCATION W/ TENANT AND FURNITURE CONTRACTOR <br />REQUIREMENTS. <br />WALL POWER IN-FEED JUNCTION BOX FOR WORKSTATIONS POWER AND TELEPHONE/DATA. VERIFY <br />POWER REQUIREMENTS WITH THE FURNITURE VENDER AND THE ELECTRICAL DRAWINGS FOR THE <br />NUMBER OF CIRCUITS TO BE PROVIDED. AT DATA/PHONE PROVIDE A DOUBLE GANG TELEPHONE BOX <br />WITH SINGLE GANG MUD RING. PROVIDE 1-1/2" CONDUIT WITH PULL STRING AND STUB-UP AT +6" <br />ABOVE THE CEILING WITH A SUPER FLEX CONDUIT, UNLESS OTHERWISE NOTED ON PLAN. EXACT <br />LOCATIONS & POWER REQUIREMENTS TO BE DETERMINED BY TENANT'S FURNITURE VENDOR. <br />K <br />WHERE PLUS HEIGHT IS INDICATED, HEIGHT IF NOT STANDARD. <br />REFER TO TYPICAL SHEET NOTE A-0.1 FOR MOUNTING HEIGHT INFORMATION. <br />TYPICAL <br />NOTE: <br />INDICATES NEW OUTLET.N <br />3.1 <br />3.2 <br />ALL POWER RECEPTACLES WITHIN 6'-0" OF SINK SHALL BE GFI. <br />PROVIDE SEPARATE CIRCUIT FOR TENANT'S COPIER, (N.I.C.) VERIFY ELECTRICAL REQUIREMENTS AND PLUG TYPE. <br />PROVIDE DUPLEX 120 VOLT, 20 AMP OUTLET TYPICAL, CONFIRM WITH TENANT. <br />3.3 <br />3.4 PROVIDE POWER FOR ELECTRICAL INSTA-HOT WATER HEATER. REFER TO SHEET A-0.3 FOR SPECIFICATION. <br />3.5 PROVIDE POWER FOR UNDER COUNTER GARBAGE DISPOSAL WITH ON/OFF SWITCH AT +44" A.F.F. VERIFY <br />ELECTRICAL REQUIREMENTS. REFER TO SHEET A-0.3 FOR SPECIFICATION. <br />3.6 PROVIDE SEPARATE CIRCUIT @ +44" A.F.F. FOR TENANT'S COFFEE MAKER, N.I.C. VERIFY ELECTRICAL REQUIREMENTS. <br />3.7 <br />3.8 PROVIDE SEPARATE CIRCUIT FOR TENANT'S TELEPHONE EQUIPMENT. VERIFY ELECTRICAL REQUIREMENTS. REFER <br />TO DIAGRAM ON SHEET A-3.0. <br />3.9 <br />3.10 GC TO COORDINATE EXACT LOCATION OF POWER AND DATA FLOOR CORES WITH TENANT'S FURNITURE VENDOR. <br />COORDINATE WITH BUILDING ENGINEER PRIOR TO CORING. <br />3.11 <br />3.12 PROVIDE 1 1/2" CONDUIT FOR VOICE/DATA AND 2" CONDUIT FOR A/V CONNECTION FROM FLOOR CORE TO <br />ADJACENT WALL <br />3.13 <br />3.14 <br />FLUSH FLOOR MOUNTED RATED JUNCTION BOX POWER AND TELEPHONE DATA IN-FEED FOR WORKSTATIONS <br />TO UNLESS OTHERWISE NOTED. VERIFY POWER REQUIREMENTS WITH THE FURNITURE VENDOR AND THE <br />ELECTRICAL DRAWINGS FOR THE NUMBER OF CIRCUITS TO BE PROVIDED. AT TELEPHONE DATA PROVIDE A <br />1-1/2" CONDUIT FROM FLOOR BOX BACK TO AN ACCESSIBLE CEILING ON THE TENANTS FLOOR. EXACT <br />LOCATION AND POWER REQUIREMENTS TO BE DETERMINED BY TENANT'S FURNITURE VENDOR. <br />WALL MOUNTED MAGNETIC HOLD OPEN. SEE HARDWARE SCHEDULE FOR SPECIFICATION. MOUNT 10" FROM <br />TOP OF DOOR. <br />H <br />3.15 CONTRACTOR TO VERIFY EXISTING ELECTRICAL PANEL AND NOTIFY ARCHITECT IF NOT POSSIBLE TO <br />REMOVE/RELOCATE. <br />3.16 ADD INTERCOM/ DOOR BUZZER/ RING CONNECT TO CAMERA ROOM. <br />BLANK PLATE.B <br />PROVIDE SEPARATE CIRCUIT CONFIGURATION FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS. REFER TO <br />SHEET A-0.3 FOR SPECIFICATION. PROVIDE (1) SINGLE DOOR FREEZER AND (3) SINGLE DOOR REFRIGERATOR AT TVS <br />BREAK ROOM 176, (2) BOTTOM FREEZER REFRIGERATOR AT YRC BREAK ROOM 159 AND (1) BOTTOM FREEZER <br />REFRIGERATOR AND (1) SINGLE DOOR REFRIGERATOR AT 2ND FLOOR STAFF BREAK ROOM 206. <br />PROVIDE SEPARATE CIRCUIT FOR MICROWAVE OVEN. REFER TO ELEVATION FOR EXACT MOUNTING HEIGHT. <br />VERIFY ELECTRICAL REQUIREMENTS. REFER TO SHEET A-0.3 FOR SPECIFICATION. GENERAL CONTRACTOR TO <br />PROVIDE EQUIPMENT. <br />TENANT'S FURNITURE VENDOR TO PROVIDE DIMENSIONS FOR FURNITURE FEEDS AND TO APPROVE LOCATIONS <br />IN FIELD PRIOR TO INSTALLATION. <br />PROVIDE POWER FOR BOTTLE FILLER, REFER TO A-0.3 FOR SPECIFICATIONS, MOUNTING HEIGHT FOR ADA. <br />PROVIDE POWER FOR AUTOMATIC FAUCET. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. <br />PROVIDE POWER FOR AUTOMATIC PAPER TOWEL DISPENSER. REFER TO SHEET A-21.4 FOR SPECS. <br />3.17 PROVIDE SEPARATE METER FOR SCOPE AREA AND EMON DEMON. <br />3.18 PROVIDE CEILING MOUNT RECESSED DUPLEX OUTLETS, COORDINATE WITH TENANT FOR EXACT LOCATIONS. <br />3.19 ALL COVER PLATES & DEVICES TO BE BUILDING STANDARD WHITE. PROVIDE COST TO REPLACE <br />THROUGHOUT AREA OF WORK AS REQUIRED AND ADJUST TO COMPLIANT HEIGHT AS REQUIRED. <br />QUANTITIES TO BE VERIFIED IN FIELD. <br />3.21 PROVIDE POWER AND PLUMBING FOR WASHER/DRYER, REFER TO A-0.3 FOR SPECIFICATIONS. <br />3.22 REFER TO ENGINEERING PLANS FOR HOT WATER CONNECTION. <br />3.23 REFER TO ENGINEERING DRAWINGS FOR PLUMBING REQUIREMENTS AND FIXTURES FOR NEW WATER HEATER CLOSET. <br />3.24 PROVIDE SEPARATE CIRCUIT FOR COUNTER HEIGHT REFRIGERATOR. REFER TO A-0.3 FOR SPECIFICATIONS. <br />3.25 PROVIDE SEPARATE CIRCUIT FOR TENANT PROVIDED MICROWAVES. VERIFY ELECTRICAL WITH TENANT AND THEIR <br />VENDOR. REFER TO ELEVATIONS FOR MOUNTING HEIGHTS INSIDE MICROWAVE SHELVES. <br />3.26 PROVIDE RECESSED OUTLETS FOR WALL MOUNT TV. EXACT LOCATION AND MOUNTING HEIGHT TO BE <br />VERIFIED IN FIELD. PROVIDE BACKING IN WALL IF REQUIRED, VERIFY REQUIREMENTS. <br />3.27 PROVIDE DUPLEX OUTLET WITH (2) USB PORTS. <br />3.28 VIRTRA 300 PROJECTION SCREENS BY CLIENT. COORDINATE LOCATION AND MOUNTING HEIGHT WITH <br />VENDOR. PROVIDE INSTRUCTOR'S STATION, COMPUTER RACK, AND C02 REFILL STATION. PROVIDE POWER <br />AS REQUIRED. <br />3.29 VIRTRA 300 CEILING MOUNTED PROJECTOR BY CLIENT. COORDINATE LOCATION AND MOUNTING HEIGHT <br />WITH VENDOR. PROVIDE (3) DEDICATED OUTLETS IN CEILING. INSTALL PER MANUFACTURER SPECIFICATIONS. <br />3SCALE: <br />NTSKEYCARD READER CONNECTION <br />2SCALE: <br />NTSIDF ROOM 235A <br />1SCALE: <br />NTSMDF ROOM 2074MDF/IDF, LOW VOLTAGE, WALL MOUNTED TV SPECIFIC KEYNOTES <br />MDF/IDF ROOM NOTES <br />1. PROVIDE FIRE TREATED PLYWOOD PER ENCLOSED LAYOUT. PAINT TO MATCH ADJACENT WALL. <br />2. ALL ELECTRICAL TO BE MOUNTED AT 18" AFF U.O.N. <br />3. ALL ELECTRICAL FEEDING RACK SHOULD BE MOUNTED AT CEILING. <br />4. EXACT DIMENSIONS SHOULD BE COORDINATED WITH TENANT PRIOR TO INSTALL. <br />5. PROVIDE EMPTY CONDUITS AT CEILING PER ENCLOSED LAYOUT. EXACT LOCATIONS TO BE VERIFIED IN FIELD. <br />6. ALL PLUG TYPE SHOULD BE VERIFIED WITH TENANT PRIOR TO INSTALL. <br />7.ALL PENETRATIONS OF THE TELECOMMUNICATION ROOMS' ENVELOPE SHALL BE FIRE‚ STOPPED. THESE <br />PENETRATIONS MAY CONSIST OF VERTICAL PENETRATIONS FOR 4" DIAMETER CONDUIT OR HORIZONTAL "PASS‚ <br />THROUGH" 4" DIAMETER CONDUIT PENETRATIONS TO LADDER RACKS. *RINGS OR "J-TYPE" HANGERS FOR <br />RISER CABLES BETWEEN COMMUNICATION CLOSETS, COPPER, OR FIBER, SHALL NOT BE USED. <br />8.ELECTRICAL – THE ENTRANCE FACILITY ROOM SHALL HAVE A MINIMUM OF TWO (2) DEDICATED 20-AMP QUAD <br />(NEMA 5-20R) ELECTRICAL OUTLETS, EACH ON A SEPARATE CIRCUIT, SHOULD BE PROVIDED FOR EQUIPMENT <br />POWER. WHERE REQUIRED, A 240V OR GREATER ELECTRICAL SYSTEM WILL BE SPECIFIED BY OCIT TO MEET <br />THE POWER REQUIREMENTS OF THE REQUIRED IT SYSTEMS. BOTH CIRCUITS SHALL HAVE ISOLATED GROUNDS <br />AND WILL BE INSTALLED PER OCIT LOCATION SPECIFICATION. EACH RECEPTACLE (OUTLET) SHALL BE <br />MOUNTED PER ENTRANCE FACILITY ROOM <br />LOW VOLTAGE NOTE <br />1. PROVIDE PRICING FOR CABLE TRAYS ABOVE CEILING THROUGHOUT THE SCOPE AREA. EXACT LAYOUT AND <br />SPECIFICATIONS TO BE COORDINATED WITH TENANT. <br />WALL MOUNT TV NOTES <br />1. COORDINATE WITH TENANT ON EXACT TV MOUNTING BRACKET TYPE WITH TENANT PRIOR TO ORDER. <br />2. EXACT LOCATIONS OF TV SHOULD BE VERIFIED IN FIELD WITH TENANT PRIOR TO INSTALL. <br />4' <br />- <br />0 <br />" <br />COMMON 4S PULL BOX. PROVIDE <br />A 1" CONDUIT <br />BACK TO CONTROLLER <br />3/4" CONDUIT TO ACCESS <br />CONTROLLER READER. <br />3/4" CONDUIT TO ELEC. HINGE <br />LOCATION <br />ACCESS CONTROL READER <br />TOP OF BOX <br />3.30 PROVIDE DEDICATED DUPLEX OUTLET FOR TENANT'S EQUIPMENT, COORDINATE WITH TENANT FOR EXACT <br />LOCATION AND MOUNT HEIGHT. VERIFY ELECTRICAL WITH TENANT. <br />3.31 PROVIDE MAGNETIC HOLD OPENS TIE INTO BUILDING'S FIRE LIFE SAFETY SYSTEM. <br />3.20 ALL OUTLETS SHOULD BE +18" A.F.F. CONTRACTOR TO VERIFY IN FIELD AND PROVIDE ALTERNATE <br />PRICING TO RAISE AS REQUIRED. <br />3.32 PROVIDE (1) 2" EMPTY CONDUIT CONNECTIONS FROM 1ST FLOOR MDF ROOM TO 2ND FLOOR IDF ROOM. <br />CONTRACTOR TO VERIFY WITH TENANT'S IT VENDOR FOR EXACT LOCATIONS AND QUANTITY. <br />3.33 FIRE TREATED BACKBOARD WITH 2" DIA. HOME RUN CONDUIT TO BASE BUILDING TELEPHONE ROOM <br />PAINTED TO MATCH WALL. VERIFY CONDUIT SIZE. <br />B <br />NEW WALL MOUNTED JUNCTION BOX. PLUS HEIGHT INDICATES HEIGHT IF NOT STANDARD. PROVIDE A SINGLE 20 <br />AMP CIRCUIT FOR HARDWARE CONNECTION OF EQUIPMENT. ELECT. SUB-CONTRACTOR IS TO CONNECT DEVICE. <br />J <br />B <br />B <br />B <br />3.34 PROVIDE FLUSH MOUNT FLOOR CORE WITH QUAD OUTLET AND TELE/DATA OUTLET IN CENTER OF THE <br />ROOM FOR TENANT'S MOVABLE EQUIPMENT. <br />B <br />B <br />B <br />*BELOW GENERAL NOTES FOR REFERENCE ONLY. COORDINATE WITH TENANT AND TENANT'S VENDOR FOR ALL REQUIREMENTS. <br />B <br />EMPLOYEE WORK AREAS NOTES: <br />A.DETAIL ACCESSIBLE ROUTE TO EMPLOYEE WORKSTATION AND SPECIFY COMPLIANCE WITH DIVISION 4. SPACES AND <br />ELEMENTS WITHIN EMPLOYEE WORKSTATIONS SHALL ONLY BE REQUIRED TO COMPLY WITH SECTIONS 11B-207.1, <br />118-215.3, 11B-302, 11B-303, 11B-308.1.1, 11B-308.1.2 AND 11B-404.2.3. COMMON USE CIRCULATION PATHS WITHIN <br />EMPLOYEE WORKSTATIONS SHALL COMPLY WITH SECTION 11B-206.2.8. (11B-203.9) <br />B. SPACES AND ELEMENTS WITHIN EMPLOYEE WORK AREAS SHALL BE DESIGNED SO THAT INDIVIDUALS WITH <br />DISABILITIES CAN APPROACH, ENTER AND EXIT THE WORK AREA. COMMON USE CIRCULATION PATHS WITHIN <br />EMPLOYEE WORK AREAS SHALL COMPLY WITH SECTION 11B-402.2. (11B-203.9) <br />C. ACCESS TO EMPLOYEE AREAS: AISLE WIDTH SERVING SPECIFIC EMPLOYEE WORKSTATION SHALL BE MINIMUM 44 <br />INCHES CLEAR IF SERVING TWO SIDES OR 36 INCHES CLEAR IF ONLY SERVING SIDE. ENTRYWAYS SHALL BE 32 INCHES <br />CLEAR WIDTH. (11B-203.9, 11B-403.5.1) <br />B <br />3.35 PROVIDE SEPARATE CIRCUIT OUTLET FOR COFFEE VENDING MACHINE BY TENANT'S VENDOR. <br />SPEC: CRANE MERCHANDISING SYSTEM, MODEL NAME - VOCE MEDIA. <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025 <br />L <br />CENSE ARC <br />EC <br />SAE O CAL ORNA <br />1700 E St Andrew Pl - 101118387, <br />20182190, 30146952 & 40138878 <br />6/5/2024