INSULATED TUNNEL DETAIL (NOT FIRE RATED) <br />INSULATION - FIBERGLASS NOISE BARRIER <br />FRICTION FIT IN WALL AND CEILING CAVITY <br />1C1 ·METAL STUDS <br /> DIETRICH OR EQUAL AS PER I.C.C. <br /> # ESR - 1166P LARR 25889 <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS PER <br />I.C.C. # ESR - 1338 <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. ESR-1663, <br /> LARR #25646 <br />METAL BOTTOM TRACK 2-1/2" x 20 <br />GAUGE ATTACH TO SLAB WITH .145" <br />DIAMETER POWER - DRIVEN FASTENER <br />MIN. 1-1/4" EMBEDMENT AT 24" O.C. <br />5/8" TYPE 'X' GYP. BD. (1) LAYER ON ONE SIDE, <br />OPPOSITE SIDE (2) LAYERS APPLIED PARALLEL <br />TO STUD WITH 1-1/4" TYPE S SCREWS ON FIRST <br />LAYER AND 1-5/8" TYPE S SCREWS ON SECOND <br />LAYER @ 8" O.C. AT VERTICAL JOINTS AND <br />PERIMETER AND 12" O.C. IN FIELD. STAGGER <br />JOINTS <br />(2) LAYERS OF 5/8" TYPE 'X' GYP. BD. <br />CEILING JOIST FRAMING. PROVIDE FIBER GLASS <br />INSULATION IN CAVITY. SEE JOIST SCHEDULE ON <br />DETAIL 7/A-30.3 <br />3-5/8" 20 GA. STUDS @ 24" O.C. MIN. PROVIDE <br />3-1/2" FIBER GLASS INSULATION FRICTION FIT IN <br />STUD CAVITY. SEE STUD CHART ON DETAIL 16. <br />FULL HEIGHT PARTITION PER FLOOR PLAN <br />C2 PARTITION TO 24" ABOVE CEILING IN DOUBLE VOLUME SPACE, <br />HORIZONTALLY BRACED PER STRUCTURAL. <br />CONT. METAL TOP TRACK. MATCH SIZE AND GA. <br />OF STUD. PROVIDE GYP. BD. CAP. <br />METAL STUD FRAMING PER STUD CHART. <br />METAL BOTTOM TRACK GAUGE ATTACH TO SLAB <br />WITH .145" DIAMETER POWER - DRIVEN <br />FASTENER MIN. 1-1/4" EMBEDMENT AT 24" O.C. <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS <br /> PER I.C.C. # ESR - 1338. <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. <br /> #ESR - 1663 <br />3-5/8" 20 GA. METAL STUD MIN. PROVIDE 3-1/2" <br />FIBERGLASS INSULATION IN STUD CAVITY. SEE <br />STUD CHART ON DETAIL #16. <br />BRACED PARTITION IN DOUBLE HEIGHT VOLUME <br />24 <br />" <br />AB <br />O <br />V <br />E <br /> <br />C <br />E <br />I <br />L <br />I <br />N <br />G <br />, <br /> <br />T <br />Y <br />P <br />. <br />LINE OF CEILING - SEE REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT <br />HORIZONTAL BRACE WHERE OCCURS. SEE <br />STRUCTURAL FOR MORE INFORMATION. <br />INSULATION BLANKET IN CEILING, TYP. <br />1 <br />1 <br />/ <br />2 <br />" <br />1/ <br />2 <br />" <br />PLASTIC LAMINATE CAP PER FINISH SCHEDULE <br />ON 3/4" SUBSTRATE <br />SCHLUTER 1/2" DECO-SG METAL REVEAL <br />FINISH WALL COVERING PER SCHEDULE <br />5/8" TYPE X GYPSUM BOARD ON EACH SIDE <br />LINE OF CEILING - SEE REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT <br />METAL STUD FRAMING PER STUD CHART. <br />METAL STUD SEISMIC BRACING AT 48" O.C. <br />ALTERNATING EACH DIRECTION TO STRUCTURE <br />ABOVE <br />5/8" GYPSUM BOARD ON EACH SIDE <br />UNDERSIDE CEILING INSULATED <br />INSULATION - FIBERGLASS NOISE BARRIER <br />FRICTION FIT IN WALL FRAMING <br />METAL GAUGE TOP TRACK ATTACH KICKER ABOVE <br />TO TOP TRACK WITH #8 TEK SHEET METAL <br />SCREWS. DO NOT <br />ATTACH TO GRID SYSTEM <br />METAL BOTTOM TRACK GAUGE ATTACH TO SLAB <br />WITH .145" DIAMETER POWER - DRIVEN <br />FASTENER MIN. 1-1/4" EMBEDMENT AT 24" O.C. <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. <br /> #ESR - 1663 <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS <br /> PER I.C.C. # ESR - 1338 <br />UNDERSIDE CEILING INSULATED <br />INSULATION - FIBERGLASS NOISE BARRIER <br />FRICTION FIT IN WALL FRAMING. <br />6" BATT INSULATION TO EXTEND 3'-0" ON <br />EITHER SIDE OF WALL <br />A1 <br />A2 <br />5 <br />A-30.1 INSULATION BLANKETS ABOVE CEILING - TYPE A2 <br />PARTITIONS <br />LINE OF CEILING - SEE REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT <br />METAL STUD FRAMING @ 16" O.C. <br />·3.5" MIN. STUD WIDTH CAN BE <br />NON-INSULATED (PER UL U419) <br />·2.5" MIN. STUD WIDTH REQUIRES 1.5" MIN. <br />THICKNESS MINERAL WOOL BATTS (PER UL <br />U448) <br />5/8" TYPE "X" GYPSUM BOARD ON EACH SIDE <br />APPLIED PARALLEL OR AT RIGHT ANGLES TO EACH <br />SIDE OF STEEL STUD 24" O.C. WITH 1" TYPE 'S' <br />DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND <br />12" O.C. AT FLOOR AND CEILING RUNNERS AND <br />INTERMEDIATE STUDS <br />ONE HOUR RATED INSULATED <br />2.5" MIN STUD WIDTH (PER UL U448) <br />INSULATION - R=8, (1.5" MIN. THICKNESS) <br />FRICTION FIT MINERAL WOOL BATTS <br />1A1 <br />SLIP TRACK ATTACHED TO UNDERSIDE OF <br />STRUCTURE ABOVE <br />·SLIP TRACK SYSTEM <br />UL-2079 CYCLICAL DESIGN ICC <br />#ESR-2012 OSHPD R-0371-FIXED <br />EQUIP. ANCHORED <br />WHI-495-PSV-1333 UL-R19236 <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS PER I.C.C. # ESR 1338 <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. #ESR - 1663 <br />·PENETRATIONS <br />ALL PENETRATIONS FIRE CAULKED WITH HILTI FIRESTOP SYSTEM OR APPROVED EQUAL. <br />REFER TO UL-W-L-3282, DETAIL 18/ SHEET A-30.0. ALL SEAMS TO RECEIVE FIRE TAPE. <br />SFD <br />FIRE DAMPER FOR HVAC DUCT PENETRATION <br />REFER TO MECHANICAL ENGINEER PLAN FOR <br />ADDITIONAL INFORMATION4 <br />A-30.1 <br />BOTTOM METAL TRACK ATTACH TO SLAB WITH <br />.145" DIAMETER POWER - DRIVEN FASTENER MIN. <br />1-1/4" EMBEDMENT AT 24" O.C. <br />· FIRE RESISTANCE RATING - ANSI/UL263 <br /> 2.5" MIN STUD WIDTH = DESIGN NO. U448 <br />3.5" MIN STUD WIDTH = DESIGN NO. U419 <br />2.5"MIN <br />(PER UL U448) <br />INSULATED PER '1A1' <br />3.5"MIN <br />(PER UL U419) <br />NON-INSULATED PER '1A' <br />1A <br />1A1 <br />METAL STUD FRAMING PER STUD CHART. <br />METAL BOTTOM TRACK GAUGE ATTACH TO SLAB <br />WITH .145" DIAMETER POWER - DRIVEN <br />FASTENER MIN. 1-1/4" EMBEDMENT AT 24" O.C. <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS <br /> PER I.C.C. # ESR - 1338 <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. <br /> #ESR - 1663 <br />1 <br />1 <br />/ <br />2 <br />" <br />6" <br />2" x 2'" x 1/4" STRUCTURAL STEEL PIPE WITH 2" x <br />9" x 3/8" STEEL PLATE WELDED TO BOTTOM OF <br />PIPE. INSTALL AT 8'-0" O.C. MAX. AND WITHIN 6" <br />OF AN UNSUPPORTED END OF WALL <br />METAL STUD ATTACHED TO EACH SIDE OF <br />STRUCTURAL STEEL PIPE <br />SECURE STEEL PLATE TO FLOOR WITH 5/8" DIA. <br />HILTI KB-TZ- BOLT EACH CORNER, MIN. 4" <br />EMBEDMENT (3-1/8" ICC ESR #1917) <br />PLASTIC LAMINATE CAP. SEE DETAIL 15. <br />36 <br />" <br /> <br />A <br />N <br />D <br /> <br />6 <br />8 <br />" <br />SECTION <br />PLAN VIEW <br />1 <br />1 <br />/ <br />2 <br />" <br />5/8" TYPE "X" GYPSUM BOARD ON EACH SIDE <br />2" <br />ONE HOUR RATED TUNNEL INSULATED <br />INSULATION - FIBERGLASS NOISE BARRIER <br />FRICTION FIT <br />1B1 <br />·METAL STUDS <br /> DIETRICH OR EQUAL AS PER I.C.C. <br /> # ESR - 1166P LARR 25889 <br />·SLIP TRACK SYSTEM <br />UL-2079 CYCLICAL DESIGN ICC <br /> #ESR-1042 OSHPD R-0371-FIXED <br /> EQUIP. ANCHORED LARR 25344 <br />WHI-495-PSV-1333 UL-R19236 <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS PER I.C.C. # ESR - 1338 <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. ESR-1663, LARR #25646 <br />·PENETRATIONS <br />ALL PENETRATIONS MUST BE FIRE CAULKED. ALL SEAM <br />TO RECEIVE FIRE TAPE <br />METAL BOTTOM TRACK 2-1/2" x 20 <br />GAUGE ATTACH TO SLAB WITH .145" <br />DIAMETER POWER - DRIVEN FASTENER <br />MIN. 1-1/4" EMBEDMENT AT 24" O.C. <br />2-1/2" x 20 GAUGE METAL STUD <br />FRAMING AT 24" O.C. <br />5/8" TYPE "X" GYPSUM BOARD <br />ON EACH SIDE <br />METAL STUD SEISMIC BRACING AT <br />48" O.C. EACH DIRECTION TO <br />STRUCTURE ABOVE <br />1" SHEETROCK BRAND <br />GYPSUM LINER PANEL <br />C-H STUD <br />LINE OF CEILING - SEE REFLECTED <br />CEILING PLAN FOR TYPE AND HEIGHT <br />LIGHT FIXTURE - SEE REFLECTED <br />CEILING PLAN FOR SPECIFICATION <br />10B <br />A-30.1 <br />10A <br />A-30.1 <br />EXISTING PARTITION BEYOND, GC TO VERIFY <br />STRUCTURE BEYOND <br />PROVIDE 16 GA. STUD (CUT TO LENGTH) AT EA <br />STUD FW/ #8 SMS TO TRACK EA FLANGE & (2) #8 <br />SMS TO EA (N) STUD. <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL <br /> AS PER I.C.C. # ESR - 1338. <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. <br /> #ESR - 1663 <br />METAL BOTTOM TRACK. ATTACH TO SLAB WITH <br />.145" DIAMETER POWER - DRIVEN FASTENER MIN. <br />1-1/4" EMBEDMENT AT 24" O.C. <br />5/8" GYPSUM BOARD ON FACE OF STUDS. <br />METAL TOP TRACK (GA. TO MATCH STUD U.O.N.) <br />LINE OF CEILING - SEE REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT <br />WALL FURRING NON-INSULATEDE <br />6" <br />4" <br />(U.O.N. <br />PER PLAN) <br />CONT. 16 GA. METAL TRACK ATTACHED TO EACH <br />STUD OF (E) WALL W/ (3) #8 SMS. <br />ME <br />T <br />A <br />L <br /> <br />S <br />T <br />U <br />D <br /> <br />F <br />R <br />A <br />M <br />I <br />N <br />G <br /> <br />P <br />E <br />R <br /> <br />S <br />T <br />U <br />D <br /> <br />C <br />H <br />A <br />R <br />T <br />. <br />MA <br />X <br />. <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br /> <br />1 <br />1 <br />' <br />- <br />0 <br />" <br />16 GA. CRC OR U-CHANNEL CONTINUOUS <br />BRIDGING. <br />16 GA. ANGLE (1-1/2"x1-1/2") AT EA STUD W/ (2) <br />#8 SMS EA. LEG <br />·NON LOAD-BEARING METAL STUD FRAMING <br /> SSMA OR EQUAL AS PER I.C.C. #ESR - 3064P <br />·NON LOAD-BEARING METAL STUD C-SECTIONS AND TRACKS <br /> SSMA OR EQUAL AS PER I.C.C. #ESR - 3064P <br />(EXAMPLE: 6" = 600 X 1/100 INCHES) <br />ALL MEMEBER DEPTHS ARE TAKEN IN 1/100 INCHES. <br />FOR ALL "T" SECTIONS MEMBER DEPTH IS THE <br />INSIDE DIMENSION. <br />MEMBER DEPTH: <br />FLANGE WIDTH: <br />(EXAMPLE: 1 5/8" = 1.625" ~ 162 X 1/100 <br />INCHES) ALL FLANGE WIDTHS ARE TAKEN IN <br />1/100 INCHES. <br />STYLE: <br />(EXAMPLE: STUD OR JOIST SECTION = S ) <br />THE FOUR ALPHA CHARACTERS UTILIZED BY THE <br />DESIGNATOR SYSTEM ARE: <br />(EXAMPLE: 0.054 IN. = 54 MILS; 1 MIL =1/1000 IN.) MATERIAL <br />THICKNESS IS THE MINIMUM BASE METAL THICKNESS IN MILS. <br />MINIMUM BASE METAL THICKNESS REPRESENTS 95% OF THE <br />DESIGN THICKNESS. <br />MIL THICKNESS: <br />S = STUD OR JOIST <br />T = TRACK <br />U = CHANNEL <br />F = FURRING <br />-600 S 162 54 <br />NOTES <br />1. PROVIDE KICKERS FOR NON-FULL HEIGHT CONDITIONS OR WHERE NOTED OTHERWISE. SEE WALL SCHEDULE FOR MORE <br />INFORMATION. <br />1.1. KICKER LENGTH SHALL BE 8'-0" MAX. <br />2. ALLOWABLE COMPOSITE LIMITING HEIGHTS ARE CALCULATED USING ICC-ES AC86-2012 <br />3. VALUES REPRESENTED ON THE CHART ARE DESIGNED TO RESIST 5 PSF OF OUT-OF-PLANE LOAD AND L/240 <br />4. PROVIDE BRIDGING @ MID-HEIGHT OR A MAX. OF 8'-0" O.C. WHERE GYPSUM BOARD IS NOT APPLIED TO BOTH SURFACES. <br />5. COMPOSITE LIMITING HEIGHTS ARE BASED ON A SINGLE LAYER OF 5/8" TYPE 'X' GYPSUM BOARD INSTALLED IN THE VERTICAL <br />ORIENTATION TO BOTH SIDE OF THE WALL OVER FULL HEIGHT USING MINIMUM NO. 6 TYPE S DRYWALL SCREWS SPACED A <br />MAXIMUM OF 12" O.C. FOR STUDS AT 24" SPACING AND 16" O.C. FOR STUDS AT 16" AND 12" SPACING. <br />STUD SIZE <br />WALL HEIGHT LIMIT KICKER <br />WALL TYPE <br />SIZE MIL/GA 12" <br />SPACING O.C. <br />SIZE SPACING16"24" <br />250S125 14'-2"18/25 <br />(SEE NOTE 1) <br />15'-4"27/22 <br />15'-10"30/20 <br />362S125 16'-8" <br />18'-2" <br />18'-3" <br />400S125 17'-6" <br />19'-5" <br />19'-5" <br />600S125 22'-9" <br />26'-9" <br />27'-1" <br />NON-STRUCTURAL METAL STUD WALL SIZING CHART <br />362S125-33 48" O.C. <br />400S125-33 48" O.C. <br />600S125-33 48" O.C. <br />12'-10"11'-3" <br />13'-11"12'-2" <br />14'-5"12'-7" <br />15'-2"13'-2" <br />16'-6"14'-5" <br />16'-7"14'-6" <br />15'-11"13'-8" <br />17'-8"15'-5" <br />17'-8"15'-5" <br />20'-1" <br />24'-4" <br />24'-7" <br />16'-4" <br />21'-3" <br />21'-6" <br />250S125 <br />250S125 <br />362S125 <br />362S125 <br />400S125 <br />400S125 <br />600S125 <br />600S125 <br />18/25 <br />27/22 <br />30/20 <br />18/25 <br />27/22 <br />30/20 <br />18/25 <br />27/22 <br />30/20 <br />EXISTING ALUMINUM MULLION <br />1/4" THICK x FULL WIDTH NEOPRENE GASKET <br />METAL EDGE COLOR TO MATCH WALL CONDITION <br />SPECIFIED WALL TYPE SEE SHEET A-2.0 <br />EXISTING GLAZING <br />1" RETURN <br />#8 S.M.S. TO EA. SIDE OF STUD, TOP AND BOTTOM <br />HEAVY GAUGE BREAK MTL. TO MATCH <br />STOREFRONT FINISH OR DRYWALL FINISH PAINTED <br />TO MATCH STOREFRONT FINISH. <br />PARTITION PER PLAN <br />EX. STOREFRONT <br />12 <br />" <br /> <br />M <br />A <br />X <br />. <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL <br /> AS PER I.C.C. # ESR - 1338. <br />FIRE EXTINGUISHER <br />CABINET - SEE PARTITION <br />LEGEND FOR SPEC. SEE <br />PARTITION PLAN FOR <br />LOCATIONS <br />B <br />PLAN SECTION A SECTION B <br />VARIES <br />MOUNTING SCREW PER <br />MANUFACTURER <br />METAL STUD PER PARTITION <br />PLAN <br />5/8" GYP.BOARD TYPICAL. <br />SE <br />E <br /> <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />PROVIDE 16 GA. STUD (CUT TO LENGTH) AT EA <br />STUD FW/ #8 SMS TO TRACK EA FLANGE & (2) #8 <br />SMS TO EA (N) STUD. <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL <br /> AS PER I.C.C. # ESR - 1338. <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. <br /> #ESR - 1663 <br />METAL BOTTOM TRACK. ATTACH TO SLAB WITH <br />.145" DIAMETER POWER - DRIVEN FASTENER MIN. <br />1-1/4" EMBEDMENT AT 24" O.C. <br />5/8" GYPSUM BOARD ON FACE OF STUDS. <br />WALL FURRING/SILL CONDITION BELOW EXTERIOR <br />WINDOWS <br />E1 <br />4" <br />(U.O.N. <br />PER PLAN) <br />CONT. 16 GA. METAL TRACK ATTACHED TO EACH <br />STUD OF (E) WALL W/ (3) #8 SMS. <br />16 GA. CRC OR U-CHANNEL CONTINUOUS <br />BRIDGING. <br />16 GA. ANGLE (1-1/2"x1-1/2") AT EA STUD W/ (2) <br />#8 SMS EA. LEGEX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />S <br />I <br />L <br />L <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />V. <br />I <br />. <br />F <br />. <br />EXISTING WALL <br />BEYOND <br />Hilti Firestop Systems <br />Hilti Firestop Systems <br />System No. W-L-3282 <br />SECTION A-A <br />WL <br /> <br />3 <br />2 <br />8 <br />2 <br />Page: 1 of 2 <br />1. Wall Assembly — The 1 or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner described in <br />the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following <br />construction features: <br />A. Studs — Wall framing shall consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) <br />lumber spaced max 16 in. (406 mm) OC. Steel studs to be min 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. <br />B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1.22 m) wide with square or tapered edges. The gypsum board type, thickness, number of <br />layers, fastener type and sheet orientation shall be as specified in the individual U300, U400, V400 or W400 Series Designs in the UL Fire <br />Resistance Directory. <br />The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. <br />2. Firestop Device* — Sleeve — Smooth steel sleeve device incorporating flat washers secured by sliding compression couplers. Device shall be <br />installed in accordance with the accompanying installation instructions. Device provided in nom 2 in. and 4 in. (51 and 102 mm) diam sizes. Max <br />diam of opening in wall for nom 2 in. and 4 in. (51 and 102 mm) diam device is 2-7/16 in. and 4-1/2 in. (62 and 114 mm), respectively. <br />UNIQUE FIRE STOP PRODUCTS INC — Smooth Firestop <br />A <br />Reproduced by HILTI, Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />September 02, 2015 <br />Page: 2 of 2 <br />2A. Firestop Device* — (Not Shown) — As an alternate to the smooth sleeve device in Item 2, threaded steel sleeve device incorporating flat <br />washers secured by threaded couplers. Device shall be installed in accordance with the accompanying installation instructions. Device <br />provided in nom 2 in. and 4 in. (51 and 102 mm) diam sizes. Max diam of opening in wall for nom 2 in. and 4 in. (51 and 102 mm) diam <br />devices is 2-7/16 in. and 4-1/2 in. (62 and 114 mm), respectively. <br />UNIQUE FIRE STOP PRODUCTS INC — Threaded Firestop <br />2B. Firestop Device* — (Not Shown) — As an alternate to the smooth sleeve and threaded sleeve devices in Items 2 and 2A, threaded steel <br />sleeve halves incorporating split nuts and split washers sized to fit the specific diam of the opening may be used. Device shall be installed in <br />accordance with the accompanying installation instructions. Device provided in nom 2 in. and 4 in. (51 and 102 mm) diam sizes. Max diam <br />of opening in wall for nom 2 in. and 4 in. (51 and 102 mm) diam device is 2-7/16 in. and 4-1/2 in. (62 and 114 mm), respectively. <br />UNIQUE FIRE STOP PRODUCTS INC — Split Sleeve <br />The L Rating of the firestop system is dependent upon the type of firestop device as tabulated below: <br />WL <br /> <br />3 <br />2 <br />8 <br />2 <br />Firestop Device <br />L Rating, CFM/sq ft (CFM/firestop device) <br />Ambient 400F <br />Smooth Firestop 37 (3)18 (2) <br />Threaded Firestop 37 (3)18 (2) <br />Split Sleeve 54 (5)47 (4) <br />3. Cables — Aggregate cross-sectional area of bundled cables in opening to be max 50 percent of the cross-sectional area of the firestop <br />device. The annular space between the cable bundle and the periphery of the firestop device to be min 0 in. (point contact) to max 3 in. (76 <br />mm). Cables to be rigidly supported on both sides of the wall assembly. Any combination of the following types and sizes of cables may be <br />used: <br />A. Max 300 pair No. 24 AWG telephone cable with polyvinyl chloride (PVC) insulation and jacket. <br />B. Max 750 kcmil single copper connector power cable with thermoplastic insulation and PVC jacket. <br />C. Max 7/C No. 12 AWG multiconductor power and control cable with PVC or cross-linked polyethylene (XLPE) insulation and PVC jacket. <br />D. Multiple fiber optical communication cable jacketed with PVC and having a max outside diameter of 1/2 in. (13 mm). <br />E. Max 3/C No. 12 AWG with bare aluminum ground, PVC insulated steel Metal-Clad cable. <br />F. Max 1 in. (25 mm) diam metal clad TEK cable with PVC jacket. <br />G. Max 2/0 aluminum SER cable. <br />H. Type RG 59/U coaxial cable with polyethylene (PE) insulation and PVC jacket. <br />4. Fill, Void or Cavity Materials* - Plug — Plug sized for the firestop device friction-fitted within the firestop device in Item 2 or 2A such that the <br />outer circumference of the dome-shaped plug is flush with either end of the firestop device. Plugs sized for the firestop device friction-fitted <br />within the firestop device of Item 2B such that the outer circumference of the dome-shaped plug is flush with both ends of the firestop device. <br />Plug(s) cut to fit around the cable bundle and installed tightly within the firestop device. <br />HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 658T Firestop Plug or CFS-PL Firestop Plug <br />* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), <br />respectively. <br />A <br />4 <br />4 <br />3 2 <br />1A <br />1B <br />3 <br />2 <br />C <br />CLASS IFIED <br />R <br />Classified by <br />Underwriters Laboratories, Inc. <br />to UL 1479 and CAN/ULC-S115 <br />US <br />Reproduced by HILTI, Inc. Courtesy of <br />Underwriters Laboratories, Inc. <br />September 02, 2015 <br />ANSI/UL1479 (ASTM E814)CAN/ULC S115 <br />F Ratings — 1 and 2 Hr (See Item 1)F Ratings — 1 and 2 Hr (See Item 1) <br />T Rating — 0 Hr FT Rating — 0 Hr <br />L Rating at Ambient — 37 or 54 CFM/Sq Ft (See Item 2)FH Ratings — 1 and 2 Hr (See Item 1) <br />L Rating At 400F — 18 or 47 CFM/Sq Ft (See Item 2)FTH Rating — 0 Hr <br />L Rating at Ambient — 37 or 54 CFM/Sq Ft (See Item 2) <br />L Rating At 400F — 18 or 47 CFM/Sq Ft (See Item 2) <br />LINE OF CEILING - SEE REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT <br />METAL STUD FRAMING. SEE STUD CHART ON <br />DETAIL 16. <br /> 3-5/8" 20 GA. TYP. @ 24" O.C. TYP. <br /> 6" 20 GA. STUDS @ 12" O.C. IN DOUBLE <br /> VOLUME SPACE <br />METAL BOTTOM TRACK GAUGE ATTACH TO SLAB <br />WITH .145" DIAMETER POWER - DRIVEN <br />FASTENER MIN. 1-1/4" EMBEDMENT AT 24" O.C. <br />SLIP TRACK ATTACHED TO UNDERSIDE OF <br />STRUCTURE ABOVE <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS <br /> PER I.C.C. # ESR - 1338. <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. <br /> #ESR - 1663 <br />2 <br />A-30.1 <br />5/8" TYPE "X" GYPSUM PER WALL TYPE <br /> C1 - (1) LAYER ON EACH SIDE <br /> C3 - (1) LAYER ON ONE SIDE, OPPOSITE SIDE <br /> (2) LAYERS APPLIED PARALLEL TO STUD WITH <br /> 1-1/4" TYPE S SCREWS ON FIRST LAYER AND <br /> 1-5/8" TYPE S SCREWS ON SECOND LAYER @ <br /> 8" O.C. AT VERTICAL JOINTS AND PERIMETER <br /> AND 12" O.C. IN FIELD. STAGGER JOINTS. <br />·SLIP TRACK SYSTEM <br />UL-2079 CYCLICAL DESIGN ICC <br />#ESR-2012 OSHPD R-0371-FIXED <br />EQUIP. ANCHORED <br />WHI-495-PSV-1333 UL-R19236 <br />FULL HEIGHT INSULATED <br />INSULATION - FIBERGLASS NOISE BARRIER FRICTION FIT. <br />STC 49 (SA-870717): <br />3-5/8" MIN. STUD WIDTH W/ 3" THICK SAFB IN CAVITY REQ. <br />C1 <br />7 <br />A-30.1 <br />OR <br />WHERE STC <br />RATING IS <br />NOTED <br />C3 FULL HEIGHT WALL TO DECK ABOVE. <br />STC 55 (NOAL 17-0539)" <br />3-5/8" 20 GA. MIN. STUD WIDTH W/ 3-1/2" THICK FIBER GLASS <br />INSULATION FRICTION FIT IN STUD CAVITY <br />FULL HEIGHT DOUBLE GYP. BD. <br />EXISTING ALUMINUM MULLION <br />1/4" THICK x FULL WIDTH NEOPRENE GASKET <br />METAL EDGE COLOR TO MATCH WALL CONDITION <br />PARTITION PER PLAN <br />EXISTING GLAZING <br />1" RETURN <br />8" MIN. <br />U.N.O. <br />VA <br />R <br />I <br />E <br />S <br />#8 S.M.S. TO EA. SIDE OF STUD, TOP AND BOTTOM <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS PER <br />I.C.C. # ESR - 1338 <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS PER <br />I.C.C. # ESR - 1338 <br />1/4" THICK x FULL WIDTH NEOPRENE GASKET <br />METAL EDGE COLOR TO MATCH WALL CONDITION <br />EXISTING GLAZING <br />#8 S.M.S. TO EA. SIDE OF STUD, TOP AND BOTTOM <br />EXISTING ALUMINUM MULLION <br />PARTITION PER PLAN <br />NOTE: <br />PROVIDE INSULATION AS REQUIRED PER <br />SPECIFIED WALL TYPE. <br />1'' RETURN <br />PAINT EXPOSED CABINET TO MATCH WALL <br />NEW RECESSED FIRE EXTINGUISHER CABINET. <br />REFER TO PARTITION NOTE SHEET FOR <br />SPECIFICATION <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />VE <br />R <br />I <br />F <br />Y <br /> <br />A <br />D <br />A <br /> <br />C <br />O <br />M <br />P <br />L <br />I <br />A <br />N <br />C <br />E <br />14 <br />- <br />LINE OF CEILING - SEE REFLECTED CEILING PLAN <br />FOR TYPE AND HEIGHT <br />METAL STUD FRAMING PER STUD CHART. <br />METAL STUD SEISMIC BRACING AT 48" O.C. <br />ALTERNATING EACH DIRECTION TO STRUCTURE <br />ABOVE <br />6" ABOVE CEILING INSULATED <br />INSULATION - FIBERGLASS NOISE <br />BARRIER FRICTION FIT IN WALL FRAMING <br />METAL TOP TRACK ATTACH KICKER ABOVE TO TOP <br />TRACK WITH #8 TEK SHEET METAL SCREWS. DO <br />NOT ATTACH TO GRID SYSTEM <br />METAL BOTTOM TRACK ATTACH TO SLAB WITH <br />.145" DIAMETER POWER - DRIVEN FASTENER MIN. <br />1-1/4" EMBEDMENT AT 24" O.C. <br />·POWER - DRIVEN FASTENERS <br /> HILTI OR EQUAL AS PER I.C.C. <br /> #ESR - 1663 <br />·GYPSUM BOARD ASSEMBLIES <br /> GYPSUM ASSOCIATION OR EQUAL AS <br /> PER I.C.C. # ESR - 1338. <br />B1 <br />6" <br />5/8" TYPE "X" GYPSUM BOARD ON EACH SIDE <br />5 <br />A-30.1 <br />PROJECT: <br />DATE: <br />DRAWN: <br />SCALE: <br />PROJECT NO: <br />REVIEWED: <br />SHEET NO: <br />SHEET TITLE: <br />STAMP AND SIGNATURE: <br />CONSULTANTS: <br />DATE DESCRIPTION DELTA <br />DRAWINGS ISSUE <br />02/15/2024 ISSUE FOR PLANNING APPROVAL <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />515 South Flower St., Suite 1200 <br />Los Angeles, CA 90071 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />www.saaia.com <br />T 310.553.3252 <br />T 213.929.1400 <br />T 949.724.8958 <br />San Francisco, CA 94105 <br />T 415.390.6793 <br />T 848.200.1200 <br />New York, NY 10017 <br />T 917.512.6688 <br />575 Market St., Suite 502 <br />711 3rd Ave., 6th Floor <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL <br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, <br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />12/18/23 <br />KL/SD/AW <br />MP <br />634772 <br />COUNTY OF ORANGE <br />PROBATION TRAINING & VOLUNTEER SERVICES <br />AND YOUTH REPORT CENTER <br />1700 E ST ANDREW PL <br />SANTA ANA, CA 92705 <br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A <br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN <br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS <br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT <br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON <br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS <br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR <br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT <br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />02/22/2024 ISSUE FOR PLAN CHECK / BID <br />02/26/2024 PLANNING COMMENTS A <br />04/03/2024 TENANT COMMENTS / FIELD REVISIONS B <br />AND PLAN CHECK COMMENTS 01 <br />A-30.0 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />8 <br />9 <br />10 <br />11 <br />18 <br />19 <br />SCALE SCALE SCALE <br />1-1/2"=1'-0" <br />SCALE SCALE SCALE SCALE <br />WALL TYPE C1, C2 AND C3 <br />SCALESCALESCALESCALE <br />SCALE SCALE <br />WALL PARTITION DETAILS <br />1-1/2"=1'-0" <br />1/2"=1'-0" <br />1-1/2"=1'-0" <br />1-1/2"=1'-0" <br />1-1/2"=1'-0" <br />1-1/2"=1'-0" <br />N.T.S.WALL TO MULLION CONNECTION <br />7 <br />AS NOTED <br />WALL TYPE A1 AND A2 <br />1 HOUR RATED-WALL TYPE 1A1 <br />1 HOUR RATED TUNNEL -WALL TYPE 1B1FURRING WALL - WALL TYPE E <br />SEMI-RECESSED FIRE EXTINGUISHER <br />WALL TO MULLION CONNECTION <br />PARTIAL HEIGHT WALL - WALL TYPE H <br />1-1/2"=1'-0" <br />1-1/2"=1'-0"13 <br />14 <br />SCALE <br />SCALE <br /> FIRE EXTINGUISHER CABINET 1-1/2"=1'-0" <br />NON-STRUCTURAL METAL STUD SIZING CHARTS <br />1-1/2"=1'-0" <br />WALL TO MULLION CONNECTION <br />1/2"=1'-0" <br />1-1/2"=1'-0" <br />FIRE RATED WALL PENETRATION DETAIL <br />1ST & 2ND FLOOR <br />WALL FURRING/SILL CONDITION BELOW EXT. WINDOWS <br />16SCALE <br />N.T.S. <br />15SCALE <br />3"=1'-0"PLASTIC LAMINATE CAP ON LOW WALL <br />12SCALE INSULATED TUNNEL -WALL TYPE 1C11-1/2"=1'-0"WALL TYPE C2 <br />WALL TYPE B1 1-1/2"=1'-0" <br />B <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025 <br />L <br />CENSE ARC <br />EC <br />SAE O CAL ORNA <br />1700 E St Andrew Pl - 101118387, <br />20182190, 30146952 & 40138878 <br />6/5/2024