REFLECTED CEILING PLAN
<br />LEGEND & KEYNOTES
<br />A-4.0
<br />AS NOTED
<br />PROJECT:
<br />DATE:
<br />DRAWN:
<br />SCALE:
<br />PROJECT NO:
<br />REVIEWED:
<br />SHEET NO:
<br />SHEET TITLE:
<br />STAMP AND SIGNATURE:
<br />CONSULTANTS:
<br />DATE DESCRIPTION DELTA
<br />DRAWINGS ISSUE
<br />02/15/2024 ISSUE FOR PLANNING APPROVAL
<br />6083 Bristol Parkway
<br />Culver City, CA 90230
<br />515 South Flower St., Suite 1200
<br />Los Angeles, CA 90071
<br />18600 MacArthur Blvd., Suite 100
<br />Irvine, CA 92612
<br />485C US Route 1 South, Suite 105
<br />Iselin, NJ 08830
<br />www.saaia.com
<br />T 310.553.3252
<br />T 213.929.1400
<br />T 949.724.8958
<br />San Francisco, CA 94105
<br />T 415.390.6793
<br />T 848.200.1200
<br />New York, NY 10017
<br />T 917.512.6688
<br />575 Market St., Suite 502
<br />711 3rd Ave., 6th Floor
<br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL
<br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE,
<br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES.
<br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED
<br />12/18/23
<br />KL/SD/AW
<br />MP
<br />634772
<br />COUNTY OF ORANGE
<br />PROBATION TRAINING & VOLUNTEER SERVICES
<br />AND YOUTH REPORT CENTER
<br />1700 E ST ANDREW PL
<br />SANTA ANA, CA 92705
<br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A
<br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y
<br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN
<br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS
<br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT
<br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON
<br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS
<br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS
<br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR
<br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT
<br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES.
<br />02/22/2024 ISSUE FOR PLAN CHECK / BID
<br />02/26/2024 PLANNING COMMENTS A
<br />04/03/2024 TENANT COMMENTS / FIELD REVISIONS B
<br />AND PLAN CHECK COMMENTS 01
<br />1ST & 2ND FLOOR
<br />REFLECTED CEILING LEGEND
<br />c
<br />3
<br />a
<br />b
<br />NEW 2x4 CEILING SYSTEM
<br />CEILING GRID
<br />MANUFACTURER:MATCH EXISTING
<br />SIZE:2x4
<br />SERIES:MATCH EXISTING
<br />COLOR:MATCH EXISTING
<br />CEILING TILE
<br />MANUFACTURER:MATCH EXISTING
<br />SERIES:MATCH EXISTING
<br />SIZE:2x4
<br />COLOR:MATCH EXISTING
<br />REFERENCE SHEET A-30.2 FOR SPECIFICATIONS AND REQUIREMENTS.
<br />DRYWALL CEILING, HEIGHT IS INDICATED IN BUBBLE IF NOT STANDARD. REFER TO DETAIL A-30.2.
<br />CEILING MOUNTED EXIT SIGN. DARK QUADRANT INDICATES FACE. ARROW(S) INDICATE
<br />DIRECTION.
<br />CEILING MOUNTED SMOKE DETECTOR TIED INTO FIRE LIFE SAFETY SYSTEM.
<br />SINGLE POLE LIGHT SWITCH, LETTER DENOTES LIGHT(S) CONTROLLED.
<br />THREE WAY SWITCH, LETTER DENOTES LIGHT(S) CONTROLLED.
<br />DIMMER SWITCH, LETTER DENOTES LIGHT(S) CONTROLLED.
<br />NEW FIXTURE TO BE PROVIDED TO MATCH EXISTING. SEE LIGHT FIXTURE SCHEDULE FOR SPEC.
<br />CEILING HEIGHT AS INDICATED.
<br />EXISTING 2X4 CEILING GRID AND TILE IS TO REMAIN. THE G.C. IS TO REPLACE ANY BROKEN OR
<br />DAMAGED TILES IN THE AREA OF WORK AND IS TO REPLACE ANY DAMAGED BY NEW
<br />CONSTRUCTION.
<br />BUILDING STANDARD WALL MOUNTED ENERGY SAVING OCCUPANCY SENSOR.
<br />BUILDING STANDARD CEILING MOUNTED ENERGY SAVING OCCUPANCY SENSOR.
<br />INDICATES NEW LIGHT FIXTURE.N
<br />+X'-X"
<br />AREA NOT IN CONTRACT (N.I.C.)
<br />SD
<br />S
<br />S
<br />D
<br />M
<br />M
<br />NEW TRIMLESS LINEAR DIFFUSER
<br />DESIGN CRITERIA NOTES
<br />FIRE AND LIFE SAFETY COMPONENTS
<br />1. ALL COMPONENTS SHALL BE WHITE U.O.N.
<br />2. FIRE PULL COMPONENTS SHALL BE RED OR OTHER OTHER ACCORDING TO LOCAL JURISDICTION.
<br />3. ALL STROBES SHALL BE CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF ACOUSTIC CEILING TILES WHERE
<br />OCCURS, U.O.N.
<br />4. ALL SPEAKERS SHALL BE FULLY RECESSED CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF ACOUSTIC
<br />CEILING TILES WHERE OCCURS, U.O.N.
<br />5. ALL SPRINKLER HEADS SHALL BE FULLY CONCEALED CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF
<br />ACOUSTIC CEILING TILES WHERE OCCURS, U.O.N. WHERE BUILDING STANDARD IS SEMI-CONCEALED, HEADS
<br />AT GWB CEILINGS SHALL BE FULLY CONCEALED.
<br />6. COMPONENTS SHALL BE MOUNTED WITH CONSISTENT CENTERLINE, U.O.N.
<br />GENERAL
<br />1. PROVIDE AND INSTALL PERFORATED CEILING GRILLE PANELS AT ALL ACOUSTIC CEILING MOUNTED SUPPLY
<br />AND RETURN LOCATIONS, U.O.N. CONFIRM COLOR OF GRILLE WITH ARCHITECT BEFORE PURCHASE AND
<br />INSTALLATION.
<br />4.1
<br />REFLECTED CEILING KEYNOTES
<br />EXPOSED CEILING NOTES
<br />1.ALL DUCTS AND DIFFUSERS, DECKING, FIRE PROOFING, CONDUITS AND OTHER DEVICES SHALL BE
<br />PAINTED WHITE U.O.N.
<br />2.ALL CONDUITS AND CABLING TO BE RAN W/ RIGHT ANGLES U.O.N.
<br />3.ALL DATA CABLING TO BE RAN IN CABLE TRAYS PAINTED TO MATCH THE CEILING.
<br />4.ALL FRAMING ATTACHED TO CEILING DECKS TO BE PAINTED TO MATCH THE CEILING U.O.N.
<br />2'X4' LED
<br />DIRECT/INDIRECT FOCAL POINT AMICA LED
<br />FAM2-24-ACR-XX-35K-1C-UNV-XX-G-XX-XX-WH 3500K -
<br />LIGHT FIXTURE SCHEDULE
<br />MARK SYMBOL FIXTURE TYPE CATALOG NUMBERMANUFACTURER COLOR TEMP REMARKS
<br />LF-1
<br />2'X2' LED
<br />DIRECT/INDIRECT FOCAL POINT 3500K -LF-2
<br />4" DIA. RECESSED LED
<br />DOWNLIGHT LITHONIA LIGHTING EVO6-35/25-MVOLT-GZ1-(E10WCP)3500K -LF-3
<br />CEILING MOUNTED
<br />EXIT SIGN
<br />EDGE LIT LED
<br />LITHONIA LIGHTING
<br />LITHONIA LIGHTING: EDGR SERIES -
<br />GREEN LETTERS 3500K CLEAR FACE WITH GREEN LETTERS, PROVIDE CEILING MOUNT THROUGHOUT
<br />U.O.N, PROVIDE WALL MOUNT AT OPEN CEILING WHERE POSSIBLE.LF-X
<br />UNDER CABINET LIGHT ALUZ LIGHTING A8 SERIES LED TAPE
<br />A8-ZIGY-STN-CL-XX-NON-DIMMING-35K-DRY-NA-XX PROVIDE SEPARATE SWITCHING, VERIFY EXACT LENGTH IN FIELDLF-4
<br />INDUSTRIAL PENDANT
<br />LIGHT FIXTURE
<br />16" ALUMINUM EXT SERIES
<br />ALEXT16LX-XX-35K-XX-SC1-CD6-XX-AL16/MWI-TF3-WAG16-PT SEE REFLECTED CEILING PLANS FOR HANGING HEIGHTSLF-5
<br />PROVIDE EXPANSION JOINT EVERY 2500 SQUARE FEET AS REQUIRED THROUGHOUT AREA OF WORK.
<br />SEE DETAIL 13/A-30.2.
<br />PROVIDE DRYWALL HEADER AT 1" BELOW ADJACENT CEILING. PAINT WHITE, FLAT FINISH.4.2
<br />PROVIDE SOUND BOOTS AT RETURN AIR GRILLES AT ALL PRIVATE OFFICES.4.4
<br />CENTER CEILING TILE AND GRID IN ROOM AS SHOWN.4.3
<br />4.5 PROVIDE EXHAUST FAN AND DIFFUSERS AS REQUIRED AT INDICATED ROOMS. SEE MECHANICAL
<br />DRAWINGS FOR MORE INFORMATION.
<br />4.6 PROVIDE 24/7 1.5 TON FOR 1ST FLOOR MDF ROOM AND 1.5 TON FOR 2ND FLOOR IDF ROOM A/C
<br />UNITS ON SEPARATE T-STAT. PROVIDE SEPARATE METER AS REQUIRED PER BUILDING STANDARDS.
<br />REFER TO ENGINEERING DRAWINGS FOR WASHER/DRYER VENTILATION.4.7
<br />4.8 NOT USED
<br />4.9 PROVIDE AB SWITCHING TO CONTROL LIGHT FIXTURES SEPARATELY.
<br />4.10 PROVIDE SOUND BLANKET OVER CEILING ABOVE FOR ADDITIONAL SOUND ATTENUATION.
<br />4.11 NOT USED.
<br />4.12 PROVIDE CODE REQUIRED DDC CONTROL UPGRADES THROUGHOUT. REFER TO ENGINEERING DRAWINGS.
<br />4.13 ALL DEVICES IN OPEN CEILING SUCH AS EXIT SIGNS, SMOKE DETECTORS, STROBES, ETC TO BE STEM
<br />MOUNTED. EXTEND DRYWALL TO DECK ABOVE WHERE REQUIRED.
<br />4.14 REWORK EXISTING HVAC, SWITCHING AND CIRCUITING AS REQUIRED AND REBALANCE THROUGHOUT.
<br />4.15 REWORK EXISTING FIRE SPRINKLERS AS REQUIRED PER NEW LAYOUT. ALL FIRE SPRINKLER HEAD TRIMS TO
<br />BE BUILDING STANDARD. AT OPEN CEILING TURN HEADS UP AS REQUIRED PER CODE.
<br />4.16 AT OPEN CEILING AREA CLEAN UP EXISTING DECK TO BE WITHOUT ANY ABANDONED CABLES, WIRE,
<br />CONDUITS, ETC. PROVIDE RIGID SPIRAL DUCTS AND ROUND REGISTERS. CONTRACTOR TO FIELD VERIFY
<br />CURRENT HVAC DUCT CONDITION AND NOTIFY ARCHITECT IMMEDIATELY FOR ANY CONFLICTS PER NEW
<br />LAYOUT. PAINT DECK ABOVE, DUCTS, CONDUITS AND ROUND REGISTERS, FLAT FINISH. ALL DEVICES AT
<br />OPEN CEILING SUCH AS EXIT SIGNS, SMOKE DETECTORS, STROBES, ETC TO BE STEM MOUNTED WITH
<br />CONDUITS AT RIGHT ANGLES, EXPOSED J-BOX, BOTTOM HEIGHT TO BE AT 10'-5" AFF TYPICAL
<br />THROUGHOUT EXPOSED CEILING. ALL RIGID CONDUIT TO BE PAINTED COLOR P-1 OR APPROVED EQUAL.
<br />PRICING TO INCLUDE EXTENDING WALL AT OPEN CEILING AREA TO DECK ABOVE. AT BUILDING
<br />PERIMETER, EXTEND (1) LAYER OF DRYWALL TO DECK ABOVE, PREPARE TO PAINT.
<br />4.17 REWORK FLEX DUCTS IN AREA OF NEW CEILING GRID. REFER TO MECHANICAL DRAWINGS FOR MORE
<br />INFORMATION.
<br />4.18 PROVIDE NEW CEILING TILES AT INDICATED LOCATIONS, REFER TO CEILING LEGEND FOR TILE SPEC.
<br />PATCH EXISTING GRID AS REQUIRED THROUGHOUT, PROVIDE NEW HVAC GRILLES THROUGHOUT.
<br />PROVIDE WALL ANGLE WHERE OCCURS, PROVIDE 7/8" SHADOW MOLDING TYPICAL THROUGHOUT.
<br />3500K
<br />3500K
<br />4.19 PROVIDE NEW HVAC GRILLES THROUGHOUT SCOPE AREA.
<br />4.20 EXISTING CEILING GRID AND TILES TO REMAIN AT INDICATED AREA. CONTRACTOR TO ALLOW 30% TO BE
<br />REPLACED. REPLACE ALL DAMAGED TILES WITH NEW.
<br />SPEC: ARMSTRONG 2X4 SECOND LOOK DUNE WHITE OR MATCH EXISTING IF DIFFERS.
<br />4.21 PAINT ALL DRYWALL SOFFIT/CEILING P-1 FLAT FINISH, REFER TO FINISH PLANS.
<br />4.22
<br />4.23 NOT USED
<br />4.24 PROVIDE HOUSE AIR AT YRC WAREHOUSE #203. PROVIDE WALL AND CEILING INSULATION AS REQUIRED.
<br />AMICA LED
<br />FAM2-22-ACR-XX-35K-1C-UNV-XX-G-XX-XX-WH
<br />SPECTRUM LIGHTING
<br />CONTACT: BRENDA LOWELL, SCI LIGHTING, 949-636-5559, BLOWELL@SCILIGHTS.COM
<br />4.25 PROVIDE (3) DEDICATED CEILING MOUNT RECESSED DUPLEX OUTLETS FOR CEILING MOUNT PROJECTORS.
<br />TENANT'S VENDOR TO PROVIDE CEILING MOUNT PROJECTORS IN CEILING, CONTRACTOR TO PROVIDE
<br />STRUCTURAL SUPPORT ABOVE PER MANUFACTURE SPECIFICATIONS. SPEC: VIRTRA V-300 FRONT
<br />PROJECTION WITHOUT STAGE.
<br />4.26 LIGHTING FIXTURES AND OTHER CEILING MOUNT ELEMENTS IN SCENARIO ROOMS AND WAREHOUSE 203
<br />TO BE HUNG AT +22' AFF TO BOTTOM OF FIXTURE TYPICAL. COORDINATE WITH TENANT ON LIGHT
<br />FIXTURE HANGING HEIGHTS OVER CAT WALK AND OPEN BELOW AREA IN FIELD TO PROVIDE GOOD
<br />LIGHTING. PROVIDE CEILING INSULATION AS REQUIRED. EXTEND DRYWALL TO DECK ABOVE WHERE
<br />REQUIRED.
<br />4.27 SURFACE WALL MOUNT LIGHT FIXTURES AT 9' OC AFF. SEE LF-6 FOR SPECIFICATIONS.
<br />WALL SURFACE MOUNTED 4'
<br />LED LIGHT FIXTURE
<br />METALUX
<br />4'-SWLED-LUMEN-LW-UNV-OPTIONS-L835-CD-1-ULF-6 3500KCOOPER LIGHTING SOLUTIONS SURFACE WALL MOUNTED BELOW CATWALK, INSTALL AT +9" A.F.F. TO CENTER
<br />OF LIGHT FIXTUREB
<br />LIGHTING FIXTURES AND OTHER CEILING MOUNT ELEMENTS IN MAT TRAINING ROOM TO BE HUNG AT
<br />+10' AFF TO BOTTOM OF FIXTURE TYPICAL. PROVIDE CEILING INSULATION AS REQUIRED. EXTEND
<br />DRYWALL TO DECK ABOVE WHERE REQUIRED. PROVIDE INSULATION AT DECK ABOVE AS REQUIRED.
<br />B
<br />NELSON
<br />ALGAZE
<br />No. C-21090
<br />REN. 03/31/2025
<br />L
<br />CENSE ARC
<br />EC
<br />SAE O CAL ORNA
<br />1700 E St Andrew Pl - 101118387,
<br />20182190, 30146952 & 40138878
<br />6/5/2024
|