Laserfiche WebLink
REFLECTED CEILING PLAN <br />LEGEND & KEYNOTES <br />A-4.0 <br />AS NOTED <br />PROJECT: <br />DATE: <br />DRAWN: <br />SCALE: <br />PROJECT NO: <br />REVIEWED: <br />SHEET NO: <br />SHEET TITLE: <br />STAMP AND SIGNATURE: <br />CONSULTANTS: <br />DATE DESCRIPTION DELTA <br />DRAWINGS ISSUE <br />02/15/2024 ISSUE FOR PLANNING APPROVAL <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />515 South Flower St., Suite 1200 <br />Los Angeles, CA 90071 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />www.saaia.com <br />T 310.553.3252 <br />T 213.929.1400 <br />T 949.724.8958 <br />San Francisco, CA 94105 <br />T 415.390.6793 <br />T 848.200.1200 <br />New York, NY 10017 <br />T 917.512.6688 <br />575 Market St., Suite 502 <br />711 3rd Ave., 6th Floor <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL <br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, <br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />12/18/23 <br />KL/SD/AW <br />MP <br />634772 <br />COUNTY OF ORANGE <br />PROBATION TRAINING & VOLUNTEER SERVICES <br />AND YOUTH REPORT CENTER <br />1700 E ST ANDREW PL <br />SANTA ANA, CA 92705 <br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A <br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN <br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS <br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT <br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON <br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS <br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR <br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT <br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />02/22/2024 ISSUE FOR PLAN CHECK / BID <br />02/26/2024 PLANNING COMMENTS A <br />04/03/2024 TENANT COMMENTS / FIELD REVISIONS B <br />AND PLAN CHECK COMMENTS 01 <br />1ST & 2ND FLOOR <br />REFLECTED CEILING LEGEND <br />c <br />3 <br />a <br />b <br />NEW 2x4 CEILING SYSTEM <br />CEILING GRID <br />MANUFACTURER:MATCH EXISTING <br />SIZE:2x4 <br />SERIES:MATCH EXISTING <br />COLOR:MATCH EXISTING <br />CEILING TILE <br />MANUFACTURER:MATCH EXISTING <br />SERIES:MATCH EXISTING <br />SIZE:2x4 <br />COLOR:MATCH EXISTING <br />REFERENCE SHEET A-30.2 FOR SPECIFICATIONS AND REQUIREMENTS. <br />DRYWALL CEILING, HEIGHT IS INDICATED IN BUBBLE IF NOT STANDARD. REFER TO DETAIL A-30.2. <br />CEILING MOUNTED EXIT SIGN. DARK QUADRANT INDICATES FACE. ARROW(S) INDICATE <br />DIRECTION. <br />CEILING MOUNTED SMOKE DETECTOR TIED INTO FIRE LIFE SAFETY SYSTEM. <br />SINGLE POLE LIGHT SWITCH, LETTER DENOTES LIGHT(S) CONTROLLED. <br />THREE WAY SWITCH, LETTER DENOTES LIGHT(S) CONTROLLED. <br />DIMMER SWITCH, LETTER DENOTES LIGHT(S) CONTROLLED. <br />NEW FIXTURE TO BE PROVIDED TO MATCH EXISTING. SEE LIGHT FIXTURE SCHEDULE FOR SPEC. <br />CEILING HEIGHT AS INDICATED. <br />EXISTING 2X4 CEILING GRID AND TILE IS TO REMAIN. THE G.C. IS TO REPLACE ANY BROKEN OR <br />DAMAGED TILES IN THE AREA OF WORK AND IS TO REPLACE ANY DAMAGED BY NEW <br />CONSTRUCTION. <br />BUILDING STANDARD WALL MOUNTED ENERGY SAVING OCCUPANCY SENSOR. <br />BUILDING STANDARD CEILING MOUNTED ENERGY SAVING OCCUPANCY SENSOR. <br />INDICATES NEW LIGHT FIXTURE.N <br />+X'-X" <br />AREA NOT IN CONTRACT (N.I.C.) <br />SD <br />S <br />S <br />D <br />M <br />M <br />NEW TRIMLESS LINEAR DIFFUSER <br />DESIGN CRITERIA NOTES <br />FIRE AND LIFE SAFETY COMPONENTS <br />1. ALL COMPONENTS SHALL BE WHITE U.O.N. <br />2. FIRE PULL COMPONENTS SHALL BE RED OR OTHER OTHER ACCORDING TO LOCAL JURISDICTION. <br />3. ALL STROBES SHALL BE CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF ACOUSTIC CEILING TILES WHERE <br />OCCURS, U.O.N. <br />4. ALL SPEAKERS SHALL BE FULLY RECESSED CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF ACOUSTIC <br />CEILING TILES WHERE OCCURS, U.O.N. <br />5. ALL SPRINKLER HEADS SHALL BE FULLY CONCEALED CEILING MOUNTED, U.O.N. MOUNT IN CENTER OF <br />ACOUSTIC CEILING TILES WHERE OCCURS, U.O.N. WHERE BUILDING STANDARD IS SEMI-CONCEALED, HEADS <br />AT GWB CEILINGS SHALL BE FULLY CONCEALED. <br />6. COMPONENTS SHALL BE MOUNTED WITH CONSISTENT CENTERLINE, U.O.N. <br />GENERAL <br />1. PROVIDE AND INSTALL PERFORATED CEILING GRILLE PANELS AT ALL ACOUSTIC CEILING MOUNTED SUPPLY <br />AND RETURN LOCATIONS, U.O.N. CONFIRM COLOR OF GRILLE WITH ARCHITECT BEFORE PURCHASE AND <br />INSTALLATION. <br />4.1 <br />REFLECTED CEILING KEYNOTES <br />EXPOSED CEILING NOTES <br />1.ALL DUCTS AND DIFFUSERS, DECKING, FIRE PROOFING, CONDUITS AND OTHER DEVICES SHALL BE <br />PAINTED WHITE U.O.N. <br />2.ALL CONDUITS AND CABLING TO BE RAN W/ RIGHT ANGLES U.O.N. <br />3.ALL DATA CABLING TO BE RAN IN CABLE TRAYS PAINTED TO MATCH THE CEILING. <br />4.ALL FRAMING ATTACHED TO CEILING DECKS TO BE PAINTED TO MATCH THE CEILING U.O.N. <br />2'X4' LED <br />DIRECT/INDIRECT FOCAL POINT AMICA LED <br />FAM2-24-ACR-XX-35K-1C-UNV-XX-G-XX-XX-WH 3500K - <br />LIGHT FIXTURE SCHEDULE <br />MARK SYMBOL FIXTURE TYPE CATALOG NUMBERMANUFACTURER COLOR TEMP REMARKS <br />LF-1 <br />2'X2' LED <br />DIRECT/INDIRECT FOCAL POINT 3500K -LF-2 <br />4" DIA. RECESSED LED <br />DOWNLIGHT LITHONIA LIGHTING EVO6-35/25-MVOLT-GZ1-(E10WCP)3500K -LF-3 <br />CEILING MOUNTED <br />EXIT SIGN <br />EDGE LIT LED <br />LITHONIA LIGHTING <br />LITHONIA LIGHTING: EDGR SERIES - <br />GREEN LETTERS 3500K CLEAR FACE WITH GREEN LETTERS, PROVIDE CEILING MOUNT THROUGHOUT <br />U.O.N, PROVIDE WALL MOUNT AT OPEN CEILING WHERE POSSIBLE.LF-X <br />UNDER CABINET LIGHT ALUZ LIGHTING A8 SERIES LED TAPE <br />A8-ZIGY-STN-CL-XX-NON-DIMMING-35K-DRY-NA-XX PROVIDE SEPARATE SWITCHING, VERIFY EXACT LENGTH IN FIELDLF-4 <br />INDUSTRIAL PENDANT <br />LIGHT FIXTURE <br />16" ALUMINUM EXT SERIES <br />ALEXT16LX-XX-35K-XX-SC1-CD6-XX-AL16/MWI-TF3-WAG16-PT SEE REFLECTED CEILING PLANS FOR HANGING HEIGHTSLF-5 <br />PROVIDE EXPANSION JOINT EVERY 2500 SQUARE FEET AS REQUIRED THROUGHOUT AREA OF WORK. <br />SEE DETAIL 13/A-30.2. <br />PROVIDE DRYWALL HEADER AT 1" BELOW ADJACENT CEILING. PAINT WHITE, FLAT FINISH.4.2 <br />PROVIDE SOUND BOOTS AT RETURN AIR GRILLES AT ALL PRIVATE OFFICES.4.4 <br />CENTER CEILING TILE AND GRID IN ROOM AS SHOWN.4.3 <br />4.5 PROVIDE EXHAUST FAN AND DIFFUSERS AS REQUIRED AT INDICATED ROOMS. SEE MECHANICAL <br />DRAWINGS FOR MORE INFORMATION. <br />4.6 PROVIDE 24/7 1.5 TON FOR 1ST FLOOR MDF ROOM AND 1.5 TON FOR 2ND FLOOR IDF ROOM A/C <br />UNITS ON SEPARATE T-STAT. PROVIDE SEPARATE METER AS REQUIRED PER BUILDING STANDARDS. <br />REFER TO ENGINEERING DRAWINGS FOR WASHER/DRYER VENTILATION.4.7 <br />4.8 NOT USED <br />4.9 PROVIDE AB SWITCHING TO CONTROL LIGHT FIXTURES SEPARATELY. <br />4.10 PROVIDE SOUND BLANKET OVER CEILING ABOVE FOR ADDITIONAL SOUND ATTENUATION. <br />4.11 NOT USED. <br />4.12 PROVIDE CODE REQUIRED DDC CONTROL UPGRADES THROUGHOUT. REFER TO ENGINEERING DRAWINGS. <br />4.13 ALL DEVICES IN OPEN CEILING SUCH AS EXIT SIGNS, SMOKE DETECTORS, STROBES, ETC TO BE STEM <br />MOUNTED. EXTEND DRYWALL TO DECK ABOVE WHERE REQUIRED. <br />4.14 REWORK EXISTING HVAC, SWITCHING AND CIRCUITING AS REQUIRED AND REBALANCE THROUGHOUT. <br />4.15 REWORK EXISTING FIRE SPRINKLERS AS REQUIRED PER NEW LAYOUT. ALL FIRE SPRINKLER HEAD TRIMS TO <br />BE BUILDING STANDARD. AT OPEN CEILING TURN HEADS UP AS REQUIRED PER CODE. <br />4.16 AT OPEN CEILING AREA CLEAN UP EXISTING DECK TO BE WITHOUT ANY ABANDONED CABLES, WIRE, <br />CONDUITS, ETC. PROVIDE RIGID SPIRAL DUCTS AND ROUND REGISTERS. CONTRACTOR TO FIELD VERIFY <br />CURRENT HVAC DUCT CONDITION AND NOTIFY ARCHITECT IMMEDIATELY FOR ANY CONFLICTS PER NEW <br />LAYOUT. PAINT DECK ABOVE, DUCTS, CONDUITS AND ROUND REGISTERS, FLAT FINISH. ALL DEVICES AT <br />OPEN CEILING SUCH AS EXIT SIGNS, SMOKE DETECTORS, STROBES, ETC TO BE STEM MOUNTED WITH <br />CONDUITS AT RIGHT ANGLES, EXPOSED J-BOX, BOTTOM HEIGHT TO BE AT 10'-5" AFF TYPICAL <br />THROUGHOUT EXPOSED CEILING. ALL RIGID CONDUIT TO BE PAINTED COLOR P-1 OR APPROVED EQUAL. <br />PRICING TO INCLUDE EXTENDING WALL AT OPEN CEILING AREA TO DECK ABOVE. AT BUILDING <br />PERIMETER, EXTEND (1) LAYER OF DRYWALL TO DECK ABOVE, PREPARE TO PAINT. <br />4.17 REWORK FLEX DUCTS IN AREA OF NEW CEILING GRID. REFER TO MECHANICAL DRAWINGS FOR MORE <br />INFORMATION. <br />4.18 PROVIDE NEW CEILING TILES AT INDICATED LOCATIONS, REFER TO CEILING LEGEND FOR TILE SPEC. <br />PATCH EXISTING GRID AS REQUIRED THROUGHOUT, PROVIDE NEW HVAC GRILLES THROUGHOUT. <br />PROVIDE WALL ANGLE WHERE OCCURS, PROVIDE 7/8" SHADOW MOLDING TYPICAL THROUGHOUT. <br />3500K <br />3500K <br />4.19 PROVIDE NEW HVAC GRILLES THROUGHOUT SCOPE AREA. <br />4.20 EXISTING CEILING GRID AND TILES TO REMAIN AT INDICATED AREA. CONTRACTOR TO ALLOW 30% TO BE <br />REPLACED. REPLACE ALL DAMAGED TILES WITH NEW. <br />SPEC: ARMSTRONG 2X4 SECOND LOOK DUNE WHITE OR MATCH EXISTING IF DIFFERS. <br />4.21 PAINT ALL DRYWALL SOFFIT/CEILING P-1 FLAT FINISH, REFER TO FINISH PLANS. <br />4.22 <br />4.23 NOT USED <br />4.24 PROVIDE HOUSE AIR AT YRC WAREHOUSE #203. PROVIDE WALL AND CEILING INSULATION AS REQUIRED. <br />AMICA LED <br />FAM2-22-ACR-XX-35K-1C-UNV-XX-G-XX-XX-WH <br />SPECTRUM LIGHTING <br />CONTACT: BRENDA LOWELL, SCI LIGHTING, 949-636-5559, BLOWELL@SCILIGHTS.COM <br />4.25 PROVIDE (3) DEDICATED CEILING MOUNT RECESSED DUPLEX OUTLETS FOR CEILING MOUNT PROJECTORS. <br />TENANT'S VENDOR TO PROVIDE CEILING MOUNT PROJECTORS IN CEILING, CONTRACTOR TO PROVIDE <br />STRUCTURAL SUPPORT ABOVE PER MANUFACTURE SPECIFICATIONS. SPEC: VIRTRA V-300 FRONT <br />PROJECTION WITHOUT STAGE. <br />4.26 LIGHTING FIXTURES AND OTHER CEILING MOUNT ELEMENTS IN SCENARIO ROOMS AND WAREHOUSE 203 <br />TO BE HUNG AT +22' AFF TO BOTTOM OF FIXTURE TYPICAL. COORDINATE WITH TENANT ON LIGHT <br />FIXTURE HANGING HEIGHTS OVER CAT WALK AND OPEN BELOW AREA IN FIELD TO PROVIDE GOOD <br />LIGHTING. PROVIDE CEILING INSULATION AS REQUIRED. EXTEND DRYWALL TO DECK ABOVE WHERE <br />REQUIRED. <br />4.27 SURFACE WALL MOUNT LIGHT FIXTURES AT 9' OC AFF. SEE LF-6 FOR SPECIFICATIONS. <br />WALL SURFACE MOUNTED 4' <br />LED LIGHT FIXTURE <br />METALUX <br />4'-SWLED-LUMEN-LW-UNV-OPTIONS-L835-CD-1-ULF-6 3500KCOOPER LIGHTING SOLUTIONS SURFACE WALL MOUNTED BELOW CATWALK, INSTALL AT +9" A.F.F. TO CENTER <br />OF LIGHT FIXTUREB <br />LIGHTING FIXTURES AND OTHER CEILING MOUNT ELEMENTS IN MAT TRAINING ROOM TO BE HUNG AT <br />+10' AFF TO BOTTOM OF FIXTURE TYPICAL. PROVIDE CEILING INSULATION AS REQUIRED. EXTEND <br />DRYWALL TO DECK ABOVE WHERE REQUIRED. PROVIDE INSULATION AT DECK ABOVE AS REQUIRED. <br />B <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025 <br />L <br />CENSE ARC <br />EC <br />SAE O CAL ORNA <br />1700 E St Andrew Pl - 101118387, <br />20182190, 30146952 & 40138878 <br />6/5/2024