Laserfiche WebLink
SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ARCH FULL <br />24" X 36" <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-5 <br />DATE: 02/23/2024 <br />REVDATEDESCRIPTION <br />REVISIONS <br />BLEED D <br />18 <br />5 <br />1 <br /> E <br />D <br />E <br />E <br />R <br />E <br /> <br />A <br />V <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />CA <br /> 92 <br />7 <br />0 <br />5 <br />ME <br />D <br />T <br />R <br />O <br />N <br />I <br />C <br />, <br /> <br />I <br />N <br />C <br />CO <br />M <br />M <br />E <br />R <br />C <br />I <br />A <br />L <br />REVISION 02/20/2024 A <br />SolarCo Energy Inc. <br /> 22982 La Cadena Dr #219, <br /> Laguna Hills, CA 92653 <br /> Lic#: 1001001 <br />PH. NO.: (949) 482 2232 <br /> permits@SolarCoEnergy.com <br />REVISION 02/23/2024 B <br />PLACARDS <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED AS SHOWN. <br />CAUTION! <br />LABEL LOCATION: <br />MAIN SERVICE PANEL & UTILITY METER& <br />SUB PANEL, AC PANEL, AC DISCONNECT <br /> PLACARDS NOTES <br />1.CEC ARTICLES 690 AND 705 AND CEC SECTION R331 MARKINGS SHOW HEREON <br />2.ALL MARKINGS SHALL CONSIST OF THE FOLLOWING: <br />A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR <br />ELECTRO-PLATING <br />B.RED BACKGROUND COLOR WITH WHITE TEXT AND LINE WORK <br />C.ARIAL FONT. <br />3.ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. <br />4.SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT USING POP-RIVETS OR <br />SCREWS. <br />5.THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. <br />6.WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS <br />AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [CEC 110.21(8) FIELD MARKING]. <br />7.ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS <br />SHALL BE WEATHER RESISTANT [CFC 605.11.1.3] <br />CODE : PER CEC 690.54 <br />PANEL BOARD ENERGIES FROM <br />TWO SOURCES OF AC POWER <br />SOLAR 715.5A AT 480V & <br />UTILITY GRID 1600A AT 480V <br />1 Junction Box <br />Scale: NTS <br />2 Solar Load Center <br />Scale: NTS <br />DC VOLTAGE IS ALWAYS PRESENT <br />WHEN SOLAR MODULES <br />ARE EXPOSED TO SUNLIGHT <br />3 AC Disconnects <br />Scale: NTS <br /> WARNING <br />4 Scale: NTS <br />CAUTION <br />POWER TO THIS SERVICE <br />IS ALSO SUPPLIED FROM <br />ON-SITE SOLAR/WIND <br />GENERATION <br />AC SYSTEM DISCONNECT <br />CAUTION <br />ALTERNATE POWER SUPPLY <br />AC SYSTEM DISCONNECT <br />WARNING <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />CODE : PER CEC 110.27(C) & OSHA 1910.145(f)(7) <br />!WARNING <br />ELECTRICAL SHOCK HAZARD <br />CODE : PER CEC 110.27(C) & OSHA 1910.145(f)(7) <br />! <br />TERMINALS ON THE LINE AND LOAD <br />SIDES MAY BE ENERGIZED <br /> IN THE OPEN POSITION <br />WARNING <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />CODE : PER CEC 690.13(B) <br />! <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) <br />WARNING <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES: TOTAL RATING OF ALL OVER <br />CURRENT DEVICES EXCLUDING MAIN <br />POWER SUPPLY SHALL NOT EXCEED <br />AMPACITY OF BUSBAR <br />CODE : PER CEC 690.13(B) <br />!WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) <br /> WARNING DUAL POWER SOURCE SECOND <br />SOURCE IS PHOTOVOLTAIC SYSTEM! <br />CODE : PER CEC 690.59 and CEC 705.12(D)(3) <br />! <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE. <br />CODE : PER CEC 705.12(B)(3)(2) <br />WARNING <br />TURN OFF PHOTOVOLTAIC <br />AC DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />CODE : PER CEC 110.27(C) and OSHA 1910.145(f)(7) <br />!WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />! <br />CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) <br />WARNING <br />SINGLE 120-VOLT SUPPLY <br />DO NOT CONNECT <br />MULTI WIRE BRANCH CIRCUITS <br />! <br />CODE : PER CEC 706.15(C)(4) and CEC 690.13(B) <br />MAIN PHOTOVOLTAIC <br />SYSTEM DISCONNECT <br />CODE : PER CEC 690.13(B) <br />RAPID SHUTDOWN FOR <br />SOLAR PV SYSTEM <br />CODE : PER CEC 690.56(C)(2) <br />DO NOT DISCONNECT <br />UNDER LOAD <br />CODE : PER CEC 690.15(B) and CEC 690.33(D)(2) <br />LABEL LOCATION: <br />AC DISCONNECT (UTILITY REQUIREMENT) <br />LABEL LOCATION: <br />AC DISCONNECT (UTILITY REQUIREMENT) <br />5 Conduit <br />Scale: NTS <br />! <br />WARNING <br />RACEWAY IS ENERGIZED WHENIN <br />THE OPEN POSITION. DO NOT <br />RELOCATE OR CUT <br />! <br />WARNING <br />FOR LINE-SIDE TAP: "THE SUM OF THE AMPERE <br />RATINGS OF ALL OVER CURRENT DEVICES ON <br />PANEL BOARDS, BOTH LOAD AND SUPPLY DEVICES, <br />EXCLUDING THE RATING OF THE OVER CURRENT <br />DEVICE PROTECTING THE BUS BAR, SHALL NOT <br />EXCEED THE AMPACITY OF THE BUS BAR. <br />PERMANENT WARNING LABELS SHALL BE APPLIED <br />TO DISTRIBUTION EQUIPMENT." <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL OVER <br />CURRENT DEVICES, EXCLUDING MAIN <br />SUPPLY OVER CURRENT DEVICE, SHALL <br />NOT EXCEED AMPACITY OF BUSBAR. <br />LABEL PER CEC 690.56(C)- PROVIDE AT AC <br />DISCONCECT FOR RAPID SHUTDOWN COMPLIANT <br />SYSTEM <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br />"OFF" POSITION TO <br />SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />SOLAR ELECTRIC <br />PV PANELS <br />PER CODE: CEC 690.54 <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT <br />RATED AC OUTPUT CURRENT 715.5 AMPS <br />NOMINAL OPERATING AC VOLTAGE 480 VOLTS <br />Main Service Panel <br />(N) AC DISCONNECT <br /> ELECTRICAL ROOM <br />(E) MAIN SWITCHBOARD <br />(E) UTILITY METER <br />(N) SOLAR LOAD CENTER <br />(N) RAKE (TYP.) <br />(N) PV MODULE <br />(N) 9 x SUNNY TRIPOWER CORE1 62-US INVERTERS <br />(ON ROOF) <br />SLC MSBUMACD <br />INV <br />INV <br />INV <br />INV INV <br />INV <br />INV <br />INV <br />INV <br />JB <br />PVM <br />GEN <br />MS <br />B <br />T <br />T <br />T <br />T <br />(E) TRANSFORMER <br />(E) MAIN SWITCHBOARD <br />(E) 3 x TRANSFORMERS <br />(E) GENERATOR <br />PU <br />L <br />L <br />M <br />A <br />N <br /> <br />S <br />T <br /> ELECTRICAL ROOM 2 <br />E DEERE AVE <br />1851 E Deere Ave - 101118504 & <br />20182282 <br />4/11/2024