Laserfiche WebLink
SCOPE OF WORK: <br />NSSE SCOPE OF WORK INCLUDES THE FOLLOWING ITEMS: <br />1.VERIFICATION OF (E) ROOF FRAMING DUE TO PANELCLAW PV SYSTEM <br />2.ANCHORAGE OF (N) PANELCLAW PV SYSTEM TO (E) BUILT UP ROOF DECK <br />SCALE: N.T.S. <br />PANELCLAW ROOFTOP ATTACHMENT @ BUILT UP ROOF <br />SCALE: N.T.S. <br />PROJECT NAME: MEDTRONICS PV PROJECT <br />DATE: 03/26/2024 SK-1 <br />FIBERTIGHT MEMBRANE <br />(BY OTHERS)(E) BUILT UP ROOF <br />(E) 2X @ 24" O.C. <br />41 <br />8" <br />51 <br />2" TYP. <br />PANELCLAW RACK <br />U-ANCHOR 2400 <br />(DESIGNED BY OTHERS) <br />(8) #15 PHILLEP HEAD DEKFAST <br />DF-#15-PH3 SCREWS <br />PANELCLAW RACK <br />U-ANCHOR 2400 <br />(DESIGNED BY OTHERS) <br />(E) 12" PLYWOOD <br />(SEE NOTE 5) <br />SEE NOTE 1 <br />(8) #15 PHILLEP HEAD DEKFAST <br />DF-#15-PH3 SCREWS <br />NOTES: <br />1. SCREWS SHALL EXTEND A MINIMUM OF 3 4" OR THREE THREADS PAST BOTTOM OF PLYWOOD, WHICHEVER IS <br />GREATER. <br />2. ALL EXPOSED WOOD OR STEEL SHALL BE WEATHER PROTECTED. <br />3. SCREWS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. <br />4. CONTRACTOR SHALL VERIFY U-ANCHOR COMPATIBILITY WITH (E) ROOFTOP MEMBRANE PRIOR TO INSTALLATION. <br />5. CONTRACTOR SHALL VERIFY THAT (E) ROOF PLYWOOD/SUBSTRATE IS FREE OF DAMAGE AND REMAINS IN NEAR <br />INSTALLATION CONDITION. <br />1851 E Deere Ave - 101118504 & <br />20182282 <br />4/11/2024