CONTRACTORGENERAL NOTES 1 <br />SOLAR PV SYSTEM TO BE INSTALLED ON <br />RESIDENTIAL STRUCTURE. <br />DESIGN SHALL COMPLY WITH THE 2010 EDITION <br />OF CALIFORNIA ELECTRIC CODE, 2008 NEC, <br />THE SAN DIEGO AREA ELECTRICAL NEWSLETTERS <br />AND ALL LOCAL ORDINANCES AND POLICIES. <br />THIS PROJECT HAS BEEN DESIGNED IN <br />COMPLIANCE WITH THE CBC SECTION 1609 TO <br />WITHSTAND A MINIMUM 85MPH WIND LOAD. <br />THE HOUSE IS (1) STORY TALL <br />THE RAFTERS ARE 2"X4" AND 24" ON CENTER <br />THIS SYSTEM WILL NOT BE INTERCONNECTED <br />UNTIL APPROVAL FROM THE LOCAL <br />JURISDICTION AND UTILITY IS OBTAINED. <br />THIS SYSTEM IS AN UTILITY INTERACTIVE <br />SYSTEM WITH NO STORAGE BATTERIES. <br />THE SOLAR PV INSTILLATION WILL NOT <br />OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />IF THE EXISTING MAIN SERVICE PANEL DOES <br />NOT HAVE A VERIFIABLE GROUNDING <br />ELECTRODE, IT IS THE CONTRACTORS <br />RESPONSIBILITY TO INSTALL A SUPPLEMENTAL <br />GROUNDING ELECTRODE. <br />EACH MODULE WILL BE GROUNDED USING THE <br />SUPPLIED CONNECTION POINTS IDENTIFIED ON <br />THE MODULE AND THE MANUFACTURER'S <br />INSTILLATION INSTRUCTIONS. <br />A LADDER SHALL BE IN PLACE FOR INSPECTION <br />IN COMPLIANCE WITH CAL-OSHA REGULATIONS. <br />PROPER ACCESS AND WORKING CLEARANCE <br />WILL BE PROVIDED AS PER SECTION 110.26 <br />CEC. <br />DC CONDUCTORS ROUTING INSIDE OF BUILDING <br />SHALL BE IN METALLIC CONDUITS AND LABELED <br />EVERY FIVE (5) FEET AS "CAUTION DC <br />CIRCUIT". <br />SUUIVANSOUIR POWEll <br />|-|8949 KENAMAR OR., STE 10 <br />1 SAN DIEGO. CA 92121 <br />- 1 P: 858-271-7758 <br />F: 838-271-7759 <br />UCENSE: C-10 839077 <br />REDETRATION <br />DANE] SIUNAN C-10 839077 <br />IDE*CY WMOY#L <br />ARCHITECTURAL STRUCTURALACCEPTED FOR CONSTRUCTION <br />SEPARATE PFYINMFS ARE REQUIRED FOR ELECTRICAL, FLUE@ING & MECHANICAL PLANS ;This set of plans and spscifications must be kept on the job at ail times and it is unlawful to make any changes orliterations on same without written permission from the City of Santa Ana. <br />i-48 acceptance of this plan and specifications SHALL NOT ii held to permit ncr be an approval 0? the violation of any ·evisions of ANY City Ordinance or State Law. <br />20TH ST <br />4 <br />·4 <br />/ r- <br />DRIVEWAY <br />- RESIDENCE <br />- PROPERTY LINE <br />rBf.*epted By <br />* CITY OF SAMTA ANA (E) MAIN SERVICE - <br />1 -6- CY-D.C. .- d <br />Date Issued ......----=-·--··-·--z:z:::am-(N) INVERTER W/ INTEGRATED - <br />DC DISCONNECT <br />(N) PV ARRAY #1 - <br />llllllllllllllllllll <br />.llll <br />llI <br /> PERMIT TYPE:65€I)---> ELECT PLBG . <br />DING 1 0113 8- g <br /> PERMIT#__co 02; <br />E-*7 <br /> OCC. GROUP-O md <br />CONSTR. UPI <br />CODE EDITION____..2.CL-Q <br /> FLOOD ZONE <br /> FLOOD ZONE GERTIE REQ'D YES =10.312013 PERMIT DRAFTpiEEZEZZIESNO:= <br /> RESIDENTIAL DEV. FEE <br />122EEL,95[RICTYE--lam WE DESCR,mON <br />OR•)11 Err: KAD,S <br />CIECKED Erf: [16 <br />¥#CH GRAI <br />E-22__ <br />A- <br />S . \jo 1 <br />SOLE: PER PLAN <br />ger Imf <br />PLAN ROOF PLANNORTH <br />OVERALL ROOF PLAN TILT - 23PV-2| REF.SCALE: <br />AZIMUTH - 180° 1 PV-2 <br />. <br />0 <br />2 3 4 5 6 <br />11 4 1 <br />7 ;9 -1· 9•7' =i <br />IF'*p <br />1 Z 3 5