Laserfiche WebLink
SHEET NO.DESCRIPTION <br />CD-1.0 <br />GENERAL NOTES, LEGENDS, AND ABBREVIATIONS <br />SITE DEMOLITION PLAN <br />SHEET INDEX: <br />C-1.0 <br />EXISTING CONDITIONSC-1.1 <br />CONSTRUCTION LEGEND: <br />ABBREVIATIONS: <br />AC ASPHALT CONCRETE <br />BACK OF SIDEWALKBSW <br />OVERALL SITE CONTROL PLANC-2.0 <br />SITE GRADING PLAN AND SECTIONSC-3.0 <br />C-4.0 <br />VICINITY MAP <br />NOT TO SCALE <br />MISCELLANEOUS DETAILS <br />BS BLUE STRIPE <br />CONCRETEC/CONC/CC <br />CAR STOPCRS <br />CONCRETE SLABCS <br />DRAIN INLETDI <br />DOUBLE WHITE STRIPEDWS <br />EDGE OF CONCRETEEC <br />EDGE OF PAVEMENTEP <br />EDGE OF GUTTEREG <br />ELECTRIC PULL BOXEPB <br />FLOW LINEFL <br />FIRE DEPARTMENT CONNECTIONFDCONN <br />GROUNDGRD <br />FINISH FLOORFF <br />FIRE HYDRANTFH <br />GRADE BREAKGB <br />METAL COVERMC <br />PULL BOXPB <br />POST INDICATOR VALVEPIV <br />ROOF DRAINRD <br />TOP CURBTC <br />TRUNCATED DOME PADTDP <br />THRESHOLDTHR <br />TRAFFIC SIGNAL PULL BOXTSPB <br />WHITE STRIPEWS <br />PROPERTY LINEPL <br />CENTER LINECL <br />E WAKEHAM AVE <br />E HUNTER AVE <br />NORMANDY PL <br />S <br />G <br />R <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br />PROJECT <br />SITE <br />GENERAL NOTES: <br />ALL WORK PERFORMED IN THIS CONTRACT SHALL CONFORM TO: <br />A.PROJECT SPECIFICATIONS. <br />B.ALL SHALL CONFORM TO THE LATEST EDITION AND SUPPLEMENTS OF THE STANDARD <br />SPECIFICATIONS FOR PUBLIC WORKS CONSTRUCTION (SSPWC) AND AMERICAN PUBLIC WORKS <br />ASSOCIATION (APWA). <br />C.2022 CALIFORNIA BUILDING CODE. <br />D.CITY OF SANTA ANA PUBLIC WORKS STANDARD PLANS. <br />ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE WORK SPECIFIED ON THE DRAWINGS <br />AND WITHIN THE VARIOUS NOTES SHOWN HEREIN. <br />THE EXISTING CONDITIONS SHOWN DIAGRAMMATICALLY ON THE PLANS ORIGINATED FROM AS-BUILT <br />DRAWINGS AND FIELD SURVEY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT <br />THE JOB SITE AND VERIFY THE EXACT EXISTING CONDITIONS UNLESS CONCEALED BEFORE <br />SUBMITTING HIS BID. ANY DISCREPANCY SHALL BE REPORTED IMMEDIATELY TO THE OWNER USING <br />THE PROPER REQUEST FOR INFORMATION FORMS PRIOR TO SUBMITTING HIS BID FOR PROPER <br />ACTION. <br />THE CONTRACTOR SHALL PROTECT ALL EXISTING STRUCTURES IN THE AREA OF WORK WHICH ARE <br />NOT INCLUDED IN THIS CONSTRUCTION. ANY DAMAGE RESULTING FROM THIS WORK SHALL BE <br />REPAIRED AND/OR REPLACED AT NO ADDITIONAL COST TO THE OWNER. <br />UNDERGROUND SERVICE ALERT: <br />BEFORE COMMENCING ANY EXCAVATION, THE CONTRACTOR SHALL OBTAIN AN UNDERGROUND <br />SERVICE ALERT INQUIRY I.D. NUMBER BY CALLING 1-800-422-4133. TWO (2) WORKING DAYS SHALL BE <br />ALLOWED AFTER THE I.D. NUMBER IS OBTAINED AND BEFORE THE EXCAVATION WORK IS STARTED <br />THAT UTILITY OWNERS CAN BE NOTIFIED. <br />PROTECTION AND RESTORATION OF EXISTING IMPROVEMENTS: <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PUBLIC AND PRIVATE <br />PROPERTY ADJACENT TO THE WORK PER SECTION 7-9 OF THE STANDARD SPECIFICATIONS. <br />REMOVALS: <br />ALL SITE PREPARATION AS INDICATED SHALL BE MADE UNDER THE CONTINUOUS INSPECTION OF <br />THE INSPECTOR OF RECORD (IOR) AND OWNER AUTHORIZED REPRESENTATIVE (OAR). SECURE THE <br />REQUIRED PERMIT FROM THE CALIFORNIA DIVISION OF INDUSTRIAL SAFETY FOR THE <br />CONSTRUCTION OF TRENCHES, SHORING OR EXCAVATIONS WHICH ARE 5 FEET OR DEEPER OR <br />WORK THAT MAY JEOPARDIZE THE WORKERS. SHORING CALCULATIONS SHALL BE PROVIDED AS <br />REQUIRED FOR APPROVAL AND PERMITTING. <br />THE CONTRACTOR SHALL KEEP THE CONSTRUCTION AREA SUFFICIENTLY DAMPENED TO CONTROL <br />DUST CAUSED BY WORK ACTIVITIES AS REQUIRED BY THE JURISDICTIONAL AGENCY. <br />ALL FILL OR BACKFILL SHALL BE COMPACTED TO AT LEAST 90% MDD (MAXIMUM DRY DENSITY) PER <br />ASTM D-1557. <br />CONSTRUCTION STAKING AND ADJUSTMENTS FOR IMPROVEMENTS SHOWN ON THESE PLANS SHALL <br />BE PERFORMED BY A LICENSED LAND SURVEYOR PAID FOR BY THE CONTRACTOR AND INCLUDED IN <br />THE CONTRACT. <br />VOIDS RESULTING FROM REMOVAL WORK SHALL BE FILLED WITH SUITABLE MATERIALS COMPACTED <br />TO 90% MAXIMUM DENSITY PER ASTM D-1557. <br />IF EXISTING UTILITIES ARE EXPOSED OR DETERMINED TO EXIST UNDER THE CONSTRUCTION LIMITS, <br />CONTRACTOR SHALL PROVIDE A FLAGGED STAKE THAT INDICATES THEIR LOCATION, TYPE OF <br />UTILITY, SIZE, PIPE MATERIAL AND DEPTH. STAKES SHALL BE INSTALLED NO LESS THAN 50' ON <br />CENTER ON STRAIGHT LINES AND AT BENDS. <br />MAINTAIN A RECORD OF LOCATION OF UTILITY MARKERS ON THE AS-BUILT PLAN AND REINSTALL <br />THEM AFTER PAVING. REPLACE BENT OR UNUSABLE MARKERS FOR ALL UTILITY LINES DISCOVERED <br />WITHIN THE WORK AREA. INSTALL BRASS UTILITY MARKERS INDICATING DIRECTIONS OF LINES AT <br />ALL CHANGES IN DIRECTIONS AFTER PAVING. INFORM THE SURVEYOR TO LOCATE AND RECORD <br />ACTUAL LOCATIONS. <br />UNCLOG, CLEAN AND FLUSH THE WORK AREA DRAINAGE SYSTEM AFTER PAVING AND IMMEDIATELY <br />BEFORE A RAIN FORECAST. <br />CALIFORNIA PUBLIC RESOURCES CODE (SECTION 5097.98) AND HEALTH AND SAFETY CODE (SECTION <br />7050.5) ADDRESS THE DISCOVERY AND DISPOSITION OF HUMAN REMAINS. IN THE EVENT OF <br />DISCOVERY OR RECOGNITION OF ANY HUMAN REMAINS IN ANY LOCATION OTHER THAN A DEDICATED <br />CEMETERY, THE LAW REQUIRES THAT GRADING IMMEDIATELY STOPS AND NO FURTHER EXCAVATION <br />OF DISTURBANCE OF THE SITE, OR ANY NEARBY AREA WHERE HUMAN REMAINS MAY BE LOCATED, <br />OCCUR UNTIL THE FOLLOWING MEASURES HAVE BEEN TAKEN: <br />A.IF THE REMAINS ARE OF NATIVE AMERICAN ORIGIN, THE DESCENDANTS FROM THE DECEASED <br />NATIVE AMERICANS HAVE MADE A RECOMMENDATION FOR THE MEANS OF TREATING OR <br />DISPOSING, WITH APPROPRIATE DIGNITY, OF THE HUMAN REMAINS AND ANY ASSOCIATED <br />GRAVE GOODS. <br />B.IF THE REMAINS ARE OF NATIVE AMERICAN ORIGIN, THE DESCENDANTS FROM THE DECEASED <br />NATIVE AMERICANS HAVE MADE A RECOMMENDATION FOR THE MEANS OF TREATING OR <br />DISPOSING, WITH APPROPRIATE DIGNITY, OF THE HUMAN REMAINS AND ANY ASSOCIATED <br />GRAVE GOODS. <br />ALL EXPORT OF MATERIAL FROM THE SITE MUST GO TO A PERMITTED SITE APPROVED BY <br />INSPECTOR OF RECORD OR A LEGAL DUMPSITE. RECEIPTS FOR ACCEPTANCE OF EXCESS MATERIAL <br />BY A DUMPSITE ARE REQUIRED AND MUST BE PROVIDED TO THE INSPECTOR OF RECORD UPON <br />REQUEST. <br />ANY ADDITIONAL SURVEYS OR TESTING AS A RESULT OF CONTRACTOR ERROR OR MISINFORMATION <br />WILL BE CHARGED TO THE CONTRACTOR. <br />SITE BOUNDARIES, EASEMENTS, DRAINAGE DEVICES, RESTRICTED USE AREAS SHALL BE LOCATED <br />PER CONSTRUCTION STAKING BY A LICENSED SURVEYOR. PRIOR TO GRADING, AS REQUESTED BY <br />THE INSPECTOR OF RECORD, ALL PROPERTY LINES, EASEMENTS, AND RESTRICTED USE AREAS <br />SHALL BE STAKED. <br />A COPY OF THE APPROVED GRADING PLANS MUST BE IN THE POSSESSION OF A RESPONSIBLE <br />PERSON AND AVAILABLE AT THE SITE AT ALL TIMES. <br />CONTRACTOR SHALL INSTALL TEMPORARY FENCING AROUND THE PERIMETER OF THE <br />CONSTRUCTION SITE AND STAGING AREA. FENCING SHALL BE MINIMUM 6 FEET TALL AND SHALL <br />HAVE A DUST/VISION BARRIER ALONG THE FULL LENGTH. THE DUST/VISION BARRIER SHALL EXTEND <br />THE LENGTH OF THE CONSTRUCTION SITE. THE FENCING SHALL BE ANCHORED TO THE SURFACE <br />AND SHALL BE ABLE TO WITHSTAND A 200-POUND HORIZONTAL POINT LOAD IN ANY DIRECTION. <br />TEMPORARY FENCING POLES AND GATES POST SHALL BE DRIVEN INTO THE GROUND. FENCE <br />STANDS WILL NOT BE ALLOWED EXCEPT FOR AREAS WHERE EXISTING CONCRETE IS TO REMAIN <br />PROTECT IN PLACE. WORK AREA AND STAGING AREA SHALL BE SECURE AT ALL TIMES. <br />THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE <br />CONDITIONS INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, DURING THE COURSE OF <br />CONSTRUCTION OF THIS PROJECT. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY, AND SHALL <br />NOT BE LIMITED TO NORMAL WORKING HOURS. <br />THE PROPOSED GRADE IS THE FINAL GRADE AND NOT THE ROUGH GRADE. THE CONTRACTOR SHALL <br />SUBTRACT THE THICKNESS OF THE PAVED SECTION AND/OR LANDSCAPE TOPSOIL SECTION TO <br />ARRIVE AT THE ROUGH GRADE ELEVATION. <br />CONSTRUCT STRAIGHT GRADES BETWEEN ELEVATIONS SHOWN ON PLAN UNLESS INTERRUPTED BY <br />A GRADE CHANGE LINE. ANY DEVIATION FROM THE GRADING PLAN MUST HAVE PRIOR APPROVAL <br />FROM THE ENGINEER OF RECORD. <br />GRADE LAWN, TURF, AND PLANTING AREA 1-1/2" MAX AT ACCESSIBLE PATH OF TRAVEL AND 2" MAX <br />AT OTHER AREAS BELOW DESIGN GRADES INDICATED. <br />THE CONTRACTOR SHALL CONTACT DIG ALERT BY DIALING 811 AT LEAST 48 HOURS PRIOR TO ANY <br />EXCAVATION TO NOTIFY UTILITY OWNERS. <br />HAND DIG ONLY AT LOCATION WHERE UNDERGROUND UTILITIES NEED TO BE PROTECTED IN PLACE. <br />8. <br />7. <br />6. <br />5. <br />4. <br />3. <br />2. <br />1. <br />9. <br />10. <br />11. <br />12. <br />13. <br />14. <br />15. <br />16. <br />18. <br />17. <br />19. <br />20. <br />21. <br />22. <br />24. <br />23. <br />PALM TREE <br />PULL BOX <br />DRAIN INLET <br />PIPE <br />FIRE HYDRANT <br />ROOF DRAIN <br />CONTOUR LINE <br />PROPERTY LINE <br />CENTER LINE C L <br />PILLAR/BUILDING <br />PL <br />POST INDICATOR VALVE <br />FIRE DEPARTMENT CONNECTION <br /># <br /># - DIA IN INCHES <br />CONSTRUCT NEW 4" THICK CONCRETE PAVEMENT OVER 4" THICK <br />CRUSHED AGGREGATE BASE PER DETAIL 1 ON SHEET C-4.0. <br />CONSTRUCT NEW 4" THICK PAVEMENT OVER 4" THICK CRUSHED <br />AGGREGATE BASE (CAB) PER DETAIL 2 ON SHEET C-4.0. <br />INSTALL NEW CAST IN PLACE TRUNCATED DOMES PER DETAIL 7 <br />ON SHEET C-4.0 <br />NEW STRIPING PER ARCHITECTURAL DRAWINGS. <br />REMOVE EXISTING AC PAVEMENT AND BASE MATERIAL, FULL <br />DEPTH. <br />REMOVE EXISTING CONCRETE PAVEMENT AND BASE MATERIAL, <br />FULL DEPTH. <br />GRIND 1.5" OF EXISTING AC PAVEMENT IN PREPARATION OF AC <br />OVERLAY PER DETAIL 3 ON SHEET C-4.0. <br />CLEAR, GRUB, AND REMOVE EXISTING GRASS/PLANTER/BUSH/ <br />GRAVEL EXPOSED SUBGRADE AREA. REMOVE EXISTING SHRUBS <br />AND ROOTS IN ITS ENTIRETY. <br />LIMIT OF WORK ------------------------------------------------------------------------ <br />LIMIT OF REMOVAL ------------------------------------------------------------------- <br />OVERLAY WITH NEW LAYERS OF AC PAVEMENT A MINIMUM OF <br />1.5" PER DETAIL 3 ON SHEET C-4.0. <br />SURVEYOR DATE: JULY 15, 2024 <br />FLORENTINO FERRER <br />FERRER & ASSOCIATES <br />LAND SURVEYORS & ENGINEERS <br />16388 COLIMA ROAD, UNIT 206-L <br />HACIENDA HEIGHTS, CA 91745 <br />APN NUMBER <br />402-322-01 <br /> SURVEYOR'S NOTES <br />1.THIS MAP REPRESENTS A TOPOGRAPHIC SURVEY OF VISIBLE FIELD <br />CONDITIONS AT THE TIME OF THIS SURVEY. NO EASEMENTS, COVENANTS, <br />CONDITIONS, OR RESTRICTIONS HAVE BEEN DETERMINED EXCEPT THOSE <br />SHOWN. <br />2.THE HORIZONTAL BASIS FOR THIS SURVEY IS N 00°06'20" W GRAND AVENUE <br />PER TRACT NO. 3841 SHEET 2 OF 2 IN THE CITY OF SANTA ANA, COUNTY OF <br />ORANGE, STATE OF CALIFORNIA. <br />3.THE VERTICAL BASIS (BENCHMARK) FOR THIS SURVEY IS DESCRIBED BY <br />OCS 2001 - DISTURBED - FD 3 3 <br />4" OCS ALUMINUM BM DISK STAMPED "3B-73-68", <br />SET IN THE TOP OF THE N END OF A CONCRETE HEAD WALL. MONUMENT IS <br />LOCATED IN THE NE CORNER OF THE INTERSECTION OF GRAND AVE AND <br />THE SANTA FE/TOPEKA RAILWAY, 42.8' E'LY OF THE CENTERLINE OF GRAND <br />AVE AND 51' N'LY OF THE MOST N'LY RAIL ALONG THE RAILWAY. MONUMENT <br />IS SET LEVEL WITH THE SIDEWALK. <br />ELEVATION = 116.36' <br />4.REFER TO AUTOCAD DWG FILE FOR ADDITIONAL SURVEY POINTS AND DATA <br />FEATURES NOT SHOWN HERE. <br />SURVEY INFORMATION: <br />FS <br />FG <br />FINISHED SURFACE <br />FINISHED GRADE <br />REMOVAL LEGEND: <br />CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC CONCRETEC/CONC/CC <br />CRUSHED AGGREGATE BASECAB <br />PLANTER AREAPA <br />MAXIMUM DRY DENSITYMDD <br />1.THE ESTIMATED QUANTITIES PROVIDED ABOVE ARE FOR REFERENCE ONLY <br />TO BE USED FOR JURISDICTIONAL PLAN CHECKING AND PERMITTING <br />PURPOSES ONLY. <br />2.ESTIMATED EARTHWORK ABOVE IS BASED ON DESIGN FINISH GRADES TO <br />EXISTING GRADES IN SURVEY. THE ESTIMATED EARTHWORK DOES NOT <br />CONSIDER THE THICKNESS OF EACH PAVEMENT MATERIAL, FOUNDATION <br />AND SLAB ON GRADE VOLUMES, THE REMOVAL OF ANY UNSUITABLE <br />MATERIAL, AND THE REMOVAL OF EXISTING BASEMENTS, PITS, VAULTS, <br />TOP SOIL OR VEGETATION. <br />3.THE ESTIMATED EARTHWORK QUANTITIES DO NOT INCLUDE SHRINKAGE <br />FACTORS DUE TO COMPACTION OR ANY OVER EXCAVATION QUANTITIES. <br />4.ESTIMATED EARTHWORK QUANTITIES ABOVE ASSUME THAT ALL ON-SITE <br />MATERIALS ARE SUITABLE FOR BACKFILLING. HOWEVER, ACTUAL EXISTING <br />ON-SITE MATERIALS AND IMPORTED MATERIALS MUST FIRST BE APPROVED <br />BY THE GEOTECHNICAL ENGINEER PRIOR TO INSTALLATION, REMOVAL, OR <br />REPLACEMENT. <br />5.INFORMATION SHOWN WITHIN THE CONSTRUCTION DOCUMENTS WAS <br />DERIVED FROM AS-BUILT PLANS. CONTRACTOR SHALL VERIFY EXISTING <br />CONDITIONS WITH THE CONSTRUCTION DOCUMENTS. IF ANY <br />DISCREPANCIES ARISE, CONTRACTOR SHALL INFORM OWNER AND DESIGN <br />TEAM. <br />ESTIMATED EARTHWORK QUANTITY <br />NOTES: <br />ESTIMATED CUT = 3.73 CU YD <br />ESTIMATED FILL = 8.15 CU YD <br />ESTIMATED NET = 4.43 CU YD (FILL) <br />REMOVE EXISTING TRUNCATED DOME IN ITS ENTIRETY. <br />FILE NO.:TENANT IMPROVEMENT PLAN <br />PROJECT LIMITS <br />CITY OF SANTA ANA <br />PUBLIC WORKS AGENCY <br />REVISIONS REFERENCES <br />NUMBER DATE INITIALS DESCRIPTION APPROVED INSTALLED <br />CONSTRUCTION COMPLETED:SHEET _ OF 8 <br />BENCHMARK NO.:ELEV.: <br />DATE <br />08/2024DESIGNED: AL DRAWN: RF CHECKED: TD <br />08/2024 <br />RECOMMENDED FOR <br />CONSTRUCTION: <br />REVIEWED FOR <br />CONSTRUCTABILITY: <br />PRINCIPAL CIVIL ENGINEER <br />08/2024 <br />PRINCIPAL CIVIL ENGINEER <br />PREPARED UNDER <br />THE SUPERVISION <br />OF: <br />RCE NO.:36079 <br />RCE NO.: <br />SENIOR CIVIL ENGINEER <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />N <br />O <br />. <br /> <br />Y <br />Y <br />- <br />N <br />N <br />N <br />N <br />: <br /> <br />1 <br />0 <br />0 <br />1 <br /> <br />S <br /> <br />G <br />R <br />A <br />N <br />D <br /> <br />A <br />V <br />E <br />. <br />GENERAL NOTES, LEGENDS, <br />AND ABBREVIATIONS <br />Underground Service Alert <br />of Southern California <br />Know what's below. <br />before you dig.Call <br />R <br />1 <br />UTILITY WATER PURVEYOR <br />CITY IF SANTA ANA WATER DIVISION <br />COSTUMER SERVICE: 714 647 5000 <br />EMAIL: water@santa-ana.org <br />WEBSITE: www.santa-ana.org/water <br />UTILITY SEWER PURVEYOR <br />CITY IF SANTA ANA PUBLIC WORKS AGENCY <br />COSTUMER SERVICE: 714 647 3380 <br />EMAIL:publicworks@santa-ana.org <br />WEBSITE: www.santa-ana.org/publicworks <br />UTILITY STORM DRAIN PURVEYOR <br />CITY IF SANTA ANA PUBLIC WORKS AGENCY <br />COSTUMER SERVICE: 714 647 3380 <br />EMAIL:publicworks@santa-ana.org <br />WEBSITE: www.santa-ana.org <br />UTILITY INFORMATION <br />1.ALL GRADING SHALL COMPLY WITH THE LATEST CBC CHAPTERS 18 AND 33, AND APPENDIX J AND <br />THE SANTA ANA MUNICIPAL CODE. A CITY GRADING PERMIT IS REQUIRED FOR GRADING. <br />2.GRADING SHALL NOT BE STARTED WITHOUT FIRST NOTIFYING THE CITY GRADING INSPECTOR. A <br />PRE-GRADING MEETING ON THE SITE IS REQUIRED BEFORE STARTING OF GRADING WITH THE <br />FOLLOWING PEOPLE PRESENT: GRADING CONTRACTOR, DESIGN CIVIL ENGINEER, <br />GEOTECHNICAL ENGINEER, GRADING INSPECTOR AND WHEN REQUIRED, THE ARCHAEOLOGIST <br />AND PALEONTOLOGIST. THE REQUIRED INSPECTIONS FOR GRADING WILL BE EXPLAINED AT THIS <br />MEETING. <br />3.AN APPROVED COPY OF THE GRADING PLANS SHALL BE ON THE PERMITTED SITE WHILE WORK IS <br />IN PROGRESS. <br />4.THE DESIGN CIVIL ENGINEER SHALL BE AVAILABLE DURING THE GRADING TO VERIFY <br />COMPLIANCE WITH THE PLANS, SPECIFICATIONS, CODE AND ANY SPECIAL CONDITIONS OF THE <br />PERMIT WITHIN HIS PURVIEW. <br />5.THE GEOTECHNICAL ENGINEER SHALL PERFORM PERIODIC INSPECTIONS AND SUBMIT A <br />COMPLETE REPORT AND MAP UPON COMPLETION OF THE ROUGH GRADING. THE COMPACTION <br />REPORT AND APPROVAL FROM THE GEOTECHNICAL ENGINEER SHALL INDICATE THE TYPE OF <br />FIELD TESTING PERFORMED. EACH TEST SHALL BE IDENTIFIED WITH THE METHOD OF OBTAINING <br />THE IN-PLACE DENSITY, WHETHER SAND CONE OR DRIVE RING, AND SHALL BE SO NOTED FOR <br />EACH TEST. SUFFICIENT MAXIMUM DENSITY DETERMINATIONS SHALL BE PERFORMED TO VERIFY <br />THE ACCURACY OF THE MAXIMUM DENSITY CURVES BY THE FIELD TECHNICIAN. <br />6.CUT AND FILL SLOPES SHALL BE NO STEEPER THAN 2 FOOT HORIZONTAL TO 1 FOOT VERTICAL <br />(2:1) EXCEPT WHERE SPECIFICALLY APPROVED OTHERWISE. <br />7.FILLS SHALL BE COMPACTED THROUGHOUT TO A MINIMUM OF 90% RELATIVE DENSITY. <br />AGGREGATE BASE FOR ASPHALTIC AREAS SHALL BE COMPACTED TO MINIMUM OF 95% RELATIVE <br />DENSITY. MAXIMUM DENSITY SHALL BE DETERMINED BY UNIFORM BUILDING CODE STANDARD <br />NO. 70-1 OR APPROVED EQUIVALENT, AND FIELD DENSITY BY UNIFORM CODE STANDARD NO. <br />70-2 OR APPROVED EQUIVALENT. <br />8.THE CONTRACTOR SHALL NOT CREATE ANY TRENCH OR EXCAVATION 5-FEET OR MORE <br />WITHOUT THE NECESSARY PERMIT FROM THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL <br />SAFETY. <br />9.ALL CUT SLOPES SHALL BE INVESTIGATED BOTH DURING AND AFTER GRADING BY THE <br />GEOTECHNICAL ENGINEER TO DETERMINE IF ANY SLOPE STABILITY PROBLEM EXISTS. SHOULD <br />EXCAVATION DISCLOSE ANY GEOLOGICAL HAZARDS OR POTENTIAL GEOLOGICAL HAZARDS, THE <br />GEOTECHNICAL ENGINEER SHALL SUBMIT A RECOMMENDED TREATMENT TO THE CITY <br />ENGINEER FOR APPROVAL. <br />10.THE PERMITTEE IS RESPONSIBLE FOR DUST CONTROL MEASURES. WATER ACTIVE SITES AT <br />LEAST TWICE DAILY. <br />11.THE LOCATING AND PROTECTION OF ALL EXISTING UTILITIES IS THE RESPONSIBILITY OF THE <br />PERMITTEE. <br />12.GRADING OPERATIONS, INCLUDING MAINTENANCE OF EQUIPMENT, WITHIN ONE-HALF (1/2) MILE <br />OF A STRUCTURE OF HUMAN OCCUPANCY SHALL NOT BE CONDUCTED BETWEEN THE HOURS OF <br />8:00 P.M. AND 7:00 A.M. ON WEEKDAYS, INCLUDING SATURDAY, OR ANY TIME ON SUNDAY OR A <br />FEDERAL HOLIDAY. (CITY OF SANTA ANA MUNICIPAL CODE SECTION 18-314) <br />13.THE PERMITTEE SHALL GIVE REASONABLE NOTICE TO THE OWNER OF ADJOINING LANDS AND <br />BUILDINGS PRIOR TO BEGINNING EXCAVATIONS, WHICH MAY AFFECT THE LATERAL AND <br />SUBJACENT SUPPORT OF THE ADJOINING PROPERTY. THE NOTICE SHALL STATE THE INTENDED <br />DEPTH OF EXCAVATION AND WHEN EXCAVATION COMMENCES. THE ADJOINING OWNER SHALL <br />BE ALLOWED AT LEAST 30 DAYS AND REASONABLE ACCESS ON THE PERMITTED PROPERTY TO <br />PROTECT HIS STRUCTURE, IF HE SO DESIRES, UNLESS OTHERWISE PROTECTED BY LAW. <br />14.ALL EXISTING DRAINAGE COURSES THROUGH THE SITE SHALL REMAIN OPEN TO HANDLE THE <br />STORM WATER; HOWEVER, IN ANY CASE, THE PERMITTEE SHALL BE HELD LIABLE FOR ANY <br />DAMAGE DUE TO OBSTRUCTING NATURAL DRAINAGE PATTERNS. <br />15.APPROVED EROSION PROTECTION DEVICES SHALL BE PROVIDED AND MAINTAINED DURING THE <br />RAINY SEASON AND SHALL BE IN PLACE AT THE END OF EACH DAY’S WORK. PROPER EROSION <br />CONTROL MEASURES MUST BE SHOWN ON THE PLANS. <br />16.CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED <br />STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITES. <br />DISCHARGES OF MATERIAL OTHER THAN STORM WATER ARE ALLOWED ONLY WHEN NECESSARY <br />FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO <br />NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR <br />THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS <br />SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR 117 AND 302. <br />POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; <br />WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES, PESTICIDES, HERBICIDES, WOOD <br />PRESERVATIVES AND SOLVENTS; ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; <br />FUELS, OILS, LUBRICANTS, AND HYDRAULIC RADIATOR OR BATTERY FLUIDS; FERTILIZERS, <br />VEHICLES/EQUIPMENT WASH WATER AND CONCRETE WASH WATER; CONCRETE, DETERGENT <br />OR FLOATABLE WASTES; WASTES FROM ANY ENGINE/EQUIPMENT STEAM CLEANING OR <br />CHEMICAL DEGREASING; AND SUPERCHLORINATED POTABLE WATER LINE FLUSHINGS. <br />DURING CONSTRUCTION, DISPOSAL OF SUCH MATERIALS SHOULD OCCUR IN A SPECIFIED AND <br />CONTROLLED TEMPORARY AREA ON-SITE, PHYSICALLY SEPARATED FROM POTENTIAL STORM <br />WATER RUN-OFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE, AND FEDERAL <br />REQUIREMENTS. <br />17.DEWATERING OF CONTAMINATED GROUNDWATER, OR DISCHARGING CONTAMINATED SOILS VIA <br />SURFACE EROSION IS PROHIBITED. DEWATERING OF NON-CONTAMINATED GROUNDWATER <br />REQUIRES A NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT FROM <br />THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD. <br />18.ALL DIRT, SAND, MUD, OR DEBRIS DEPOSITED OR SPILLED UPON PUBLIC STREETS DURING ANY <br />GRADING, HAULING, OR EXPORT OPERATIONS SHALL BE IMMEDIATELY CLEANED UP BY THE <br />DEVELOPER, HIS CONTRACTOR, SUBCONTRACTORS, OR AGENTS TO THE SATISFACTION OF THE <br />CITY ENGINEER. FAILURE TO DO SO WILL BE CAUSE FOR STOPPING ALL SUCH GRADING, <br />HAULING, OR EXPORT WORK BY THE CITY UNTIL SUCH TIME AS THE STREETS ARE CLEANED. <br />19.ALL TRUCKS HAULING DIRT, SAND, OIL, OR OTHER LOOSE MATERIALS ARE TO BE COVERED OR <br />SHOULD MAINTAIN AT LEAST TWO FEET OF FREEBOARD IN ACCORDANCE WITH THE <br />REQUIREMENTS OF CVC SECTION 23114. <br />20.CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OF ALL DAMAGES TO PUBLIC PROPERTIES <br />THAT ARE CAUSED BY THE WORK ON-SITE. REPAIR MUST BE COMPLETED TO THE SATISFACTION <br />OF THE CITY ENGINEER. <br />21.MINIMUM ASPHALT PAVEMENT SECTIONS SHALL BE: <br />• 3”AC/6”AB - PARKING AISLES <br />• 4”AC/8”AB - DRIVES [COMMERCIAL] <br />• 4”AC/12”AB - DRIVES [INDUSTRIAL] <br />• 3” A.C. OVER 4” A.B. - PARKING STALLS [MULTI-FAMILY] <br />• 3” A.C. OVER 8” A.B. - DRIVE AISLES [MULTI-FAMILY] <br />22.EARTHWORK VOLUMES: <br />CUT 3.73 CUBIC YARDS <br />FILL 8.15 CUBIC YARDS <br />NET 4.43 CUBIC YARDS <br />23.IF THE NET VOLUMES EXCEED 500 CUBIC YARDS, THE CONTRACTOR MUST SUBMIT A HAUL <br />TRUCK ROUTE TO THE CITY FOR APPROVAL. HAUL ROUTE SHALL INCLUDE THE LOCATION OF <br />BORROW AND/OR DISPERSEMENT SITE, ALL STREETS INCLUDED IN THE ROUTE, THE PROPOSED <br />STAGING AREA AND THE MAXIMUM GROSS WEIGHT OF THE TRUCKS WHEN LOADED. <br />24.SUBMIT AN 8 ½” X 11” HAUL ROUTE MAP OF APPROPRIATE SCALE WHICH INDICATES THE <br />LOCATION OF THE PROJECT SITE, SHOWING STREETS AND DIRECTION OF HAULING UP TO AND <br />INCLUDING THE END OF THE ROUTE. <br />25.PURSUANT TO ASSEMBLY BILL 3019, NO EXCAVATION PERMIT IS VALID UNLESS THE <br />CONTRACTOR CONTACTS AND OBTAINS AN INQUIRY I.D. NUMBER FROM “UNDERGROUND <br />SERVICE ALERT” (1-800-422-4133) AT LEAST TWO WORKING DAYS PRIOR TO COMMENCING <br />EXCAVATION. <br />26.SEPARATE PERMITS MUST BE OBTAINED FROM THE CITY BUILDING AND SAFETY DIVISION FOR <br />THE CONSTRUCTION OF RETAINING WALLS, LIGHT POLES, TRASH ENCLOSURES, ON-SITE <br />PLUMBING AND ALL BUILDING STRUCTURES. <br />27.ALL FONTS ON PLANS SHOULD BE A MINIMUM OF 0.1”. <br />OWNER: NARESH ARAYA <br />EMAIL: Nkarya@gmail.com <br />CONTACT: 949 400 5961 <br />OWNER INFORMATION <br />GENERAL GRADING NOTES: <br />C-1.0 <br />NOTICE TO PROCEED NTP1 <br />25. <br />26. <br /> LEGEND: <br />PARCEL 1. AS SHOWN ON A MAP FILED IN BOOK 38, <br />PAGE 25 OF PARCEL MAPS, ORANGE COUNTY, <br />CALIFORNIA. <br />LEGAL DESCRIPTION <br />ENLARGED SITE CONTROL PLANC-2.1 <br />C-5.0 EROSION CONTROL PLAN <br />C-5.1 EROSION CONTROL DETAILS <br />Behrooz Sarlak 4/7/2025